You are on page 1of 21

SEMINAR ON

I.O.C.L. COMPLEX REFINERY BARUNI, (BIHAR)

Submitted toEr. SANDEEP KUMAR

Submitted byMD FIRDAUSH ALAM EEE 5th SEM . 90210718898

BARAUNI REFINERY

ABOUT I.O.C.L.
IOCL

is the Indias flagship national oil company.

is the 18th largest co. in the world & the no. 1 Petroleum trading co. in Asia Pacific Region.
IOCL IOCL

is the top ranked co. among both private & public sectors at 116th position in the worldwide list.

Guwahati

Pani pat

Gujarat

Barauni

Haldia

Mathura

Digboi

ABOUT BARAUNI REFINERY


Barauni

Refinery is the 7th refinery of Indian oil .

The

original refinery with 6 MMTPA ( million metric tones per annum ) Capacity was built and commissioned in 1965.
At

a time its capacity is 12 MMTPA & and 12 to 15 mmtpa is in progress.


The

cost of the refinerys construction was Rs 9024 crores .

It recives crude oil through the Chaksu-Kamal branch pipeline of the haldea-barauni pipeline, Vadinar Gujrat coast to barauni through a 1,339km long pipelines. baraunit refinery meets demands of petroleum pruducts not only of Bihar but also the entire Northwest

MAJOR PRODUCTS OF BARAUNI REFINERY


Liquefied Petrolem Gas (LPG) Naphtha Motor Spirit Superior Keroseen Oil (SKO) High Speed Diesel (HSD) Aviation Turbine Fuel (ATF) 80 MT Gasoline Bitumen Sulphur

Products from Refinery


96 RON GASOLINE

LPG

BITUMEN

NAPHTHA

SULPHUR

MOTOR SPIRIT

HEAVY PETROLEUM STOCK


HSD SKO

ATF

ABOUT

ELECTRICAL

In the electrical field there have CAPTIVE POWER PLANT . Captive Power Plant :In this power plant generated power is used to themself. *Refinery captive power plant generation capacity is 225 MW . *There have three steam turbine & five gas turbine generator are used for all refinery & refinery township.

*There is 132kv,grid by BIHAR ELECTRICITY BOARD as stand by source.

SOURCE OF ELECTRIC POWER IN REFINERY


1. STG 1x3 25x3 75 MW

2. GTG
3. BSEB

1x5

30x5

150 MW
132-KV

(BIHAR STATE ELECTRICITY BOARD)

STEAM TURBINE GENERATOR


The Requirements Are :

D.M. PLANT AIR FUEL BOILERS TURBINES GENERATORS CONDENSOR EJECTOR HIGH PRESSURE HEATER DEAREATOR

BOILER
ECONOMISER
TURBINE

G E N

H.P. HEATER

CONDENSER

C.E.P. L.P. HEATER B.F.P. DEAREATER

Basic Idea Of Steam Turbine Generator

STEAM TURBINE TECHNICAL DATA


Max. Continuous rating Most economical rating KW KW 25,000 25,000

Zero extraction rating


Turbine normal speed Turbine trip speed Direction of rotation Facing

KW
RPM RPM

NA
3,000 3,300 Clock Wise

Specifications of Steam Generator


Active Power Apparent Power Voltage Current P. F. Speed Frequency Connection of Stator Winding Unbalance Loading Field Current for Rated Output No Load Field Current Generator Type No. of Turbo generator Sets = = = = = = = = = = = = = 25 MW 31.25 MVA 11000 Volts 1640 Amps 0.8 lag 3000 RPM 50 Hz Y 10 % Continuous 633 Amps 226 Amps TART 750-24 P 3

Gas Turbine Generator


The Requirements Are:

Air (Dust free) Fuel Combustion Axial flow compressor Nozzles Spark plug Turbines Generators

SIMPAL CYCLE OF GAS TURBINE GENERATOR


R FUEL GT EXHAUST

COMBUTION

COMPRESSOR

TURBINE

GENERATOR

INLET AIR

EFFICIENCY

28% TO

34%

OPEN DIAGRAM OF GAS TURBINE

132 KV SWITCH YARD


It has five incoming bays:

Bay-1 for 132kv Startup Transformer-1 Bay-2 for 132kv line 1 from Barauni Bay-3 for 132kv line 2 from Munak Bay-4 for 132kv Bus coupler.

Bay-5 for 132kv Startup Transformer-2

132 KV SWITCH YARD


BAY 1
S/U TR 1

BAY 2
132 KV LINE 1

BAY 3
132 KV LINE 2

BAY 4
B/C

BAY 5
S/U TR 2

452 89LE2 89LE2

89AE1 89TE2 89LE1 89LE1 89A 89AE2 89TE1 52 52

89BE1 89TE2 89B 89BE2 89TE1

52

89BE

89BE

52

89BE 89A 89B 89A 89B

89BE

89A

89B

89A

89B

Arabic

Thank You
Korean