You are on page 1of 27

CDMA BSS Hardware Description

(ZTE Make)
Mechanical Features of BSC
 BSC has two kinds of rack:the central rack and the vocoder rack.
 Central rack and vocoder rack apply standard rack and insertion boxes.
The different types of insertion box are composed of different inserted
boards.
 From top to bottom, each rack contains: a power distribution insertion
box, 3~5 function insertion boxes, a fan box and dust-proof shelf.
 There are four kinds of function insertion boxes:
HIRS box: consists of PSMB, NIM, NCM.
CDSU box: consists of PSMB, CDSU, CPM, TCM, GPSIM, etc.
SVBS box: consists of PSMB, SVM, SVICM.
PCFS box:consists of PSMB,PCFIM,PCF.
 Max. number of broads in each function insertion box:22
Performance of BSC
 Max.number of E1 links between BSC and MSC: 240
 Max.number of BTS can be connected with:380
 Max. number of selector/vocoder :7200
 Max. traffic processing capability:5040 Erl ( 7200 x 0.7 )
 Support soft handoff between BSC
 8K 、 13K QCELP and 8k EVRC vocoder
 Support packet data service,with a data rate up to 153.6kbps
II. Subsystems of BSC
 HIRS:High-speed Interconnection Routing Subsystem
 SVBS:Selector Vocoder Bank Subsystem
 PCFS:Packet Control Function Subsystem
 CPS:Call Processing Subsystem
 CDSUS:Channel Data Service Unit Subsystem
 TS:Timing Subsystem
Traffic & Signaling between each
subsystem by B-HIRS

A10/A11 PDSN
TS PCFS

packet data

O&M voice A1/A2 MSC


BSM B-HIRS SVBS

Abis

BTS CDSUS CPS


HIRS
HIRS Subsystem is switching center and packet data
exchange platform of BSC.

Functions of HIRS :
 Packet data switching
 Timing distribution , monitor GPS
 Software downloading
 Operation and maintenance management on the whole BSS
HIRS Shelf Structure
P N N N N N N N N N N N N N N N N N N N N P
S I I I I I I I I I C C I I I I I I I I I S
M M M M M M M M M M M M M M M M M M M M M M
B B

NCM: Network Control Module


NIM: Network Interface Module
PSMB : Power Supply Module
NCM
NCM is the core module in HIRS shelf
 When NCM is in slot 11,it must connect with port 6 of NIM in slot 9 via the
internal serial bus on backplane.
 When NCM is in slot 12,it must connect with port 6 of NIM in slot 14 via the
internal serial bus on backplane.
 2 NCM working mode: active and standby
NCM Functions
Major functions of NCM :
 Gateway function:data receiving of CO bus and distribution of DIS bus,routing of data
frame inside/outside of the local shelf
 Distribution of software of respective modules and configuration information;
 Fault detection, isolation, report and recovery in HIRS network;
 GPS clock distribution;
 Serving as the foreground PC of BSM to communicate with the background through
10/100Mbps Ethernet
NIM Functions
 Receive/send RS-422 serial data
 Receive/send data through DISCO
 8 + 1 redundancy
 Clock receiving and distributing
 Reports module working status to NCM via
I2C bus and accepts NCM control
SVBS Functions
SVBS is the core part for enabling voice services and supporting SS7
signaling MTP1 and MTP2.
Judge and implement soft handoff: select a path in several soft handoff path by
the quality for code type conversion
Code type conversion function: It enables the conversion between 64K PCM
codes and variable rate of QCELP codes;
 Enables echo cancellation for PCM data on the forward link
Power control
Signaling handle
SVBS Shelf Structure
P S S S S S S S S S S S S S S S S S S P
S V V V V V V V V V V V V V V V V V V S
M M M M M M M M M I I M M M M M M M M M
B C C B
M M

SVICM: Selector Vocoder Interface Control Module


SVM: Selector Vocoder Module
PSMB : Power Supply Module
Input and Output interface

Connected with NIM via RS422 port

SVBS Subsystem

4*E1 interfaces connected with MSC


SVICM
S-HIRS:Communicate
Functions with HIRS Network
 Distribute forward traffic and signaling ( SVMSVICM  NIM )
 Distribute reverse traffic and signaling (SVMSVICM  NIM )
 Distribute signaling interior SVBS ( SVMSVICM )
Receive and Distribute Clock and TOD message
Manage and control SVM
Signaling handling
Code type conversion between MSC and BSS via
DTI
Structure of SVICM
SVBS
SVICM I2C
C_BUS
NIM
U DIS
CO
gateway 时钟
RS422
SVC
SVM1 SVM SVM
Clock
7 8
distribution
DTI

4*HW
4*E1
MSC
SVM - Selector & Vocoder Module
 transcoding between PCM and QCELP
 reverse outer-loop power control
 soft handoff
 handle layer 3 of Abis interface and layer 2 of IS-95
signaling
 assign the timeslot
Structure of SVM
SVE1
Data Interface

SVP
SVE2
maintenance bus HW interface

clock interface

SVE15

 A SVM contain 1 SVP and 15 SVEs.


 SVICM receive traffic data from the RS-422 port of NIM then forward to
SVM,SVP forward to SVE,SVE transcoding to PCM and send through
HW,in other direction,SVE transcoding PCM to QCELP or EVRC,then
send to SVP,then to SVICM,and then NIM.
PCFS
Each BSC can support 10 PCFS subsystems.
Each PCFS subsystem comprises 1 PCFIM board and 8 PCF boards.
Each PCFS subsystem is connected with the PDSN via PCFIM board, and
provides a 10M/100M self-adaptive physical Ethernet interface through the
PCFIM board.
Each PCFS subsystem can carry 4000 PPP connections (Dormant+Active),
and 240 activated PPP connections (total number of active ones).
PCFS Functions
To Select a service path with best quality among multiple soft handoff paths for
data GRE encapsulation.

Enables adaptation between GRE data packets and RLP data packets;.

To establish, configure and maintain A8 and A10 links via A9 and A11 interfaces.

To establish PPP link between MS and PDSN to enable packet data service
transmission.
Input and Output Interface

PCFS provides a 10M/100M fast Ethernet interface to be connected with


PDSN.
PCFS provides a RS422-port to be connected with HIRS switching
network.
CPS

CPS is a joint point of BSS system’s resource


management and call signaling protocol
processing.
CPS comprises two modules:CPM and PAM.
CPS Functions
Handle the signaling of Abis interface
Radio resource maintenance,management and distribution
Trunk resource management
provides A signaling interface. It fulfills A interface startup and re-
startup, A interface protective switching, activation of failing data link,
control of link labels, and delivery of A messages.
Control over loading of BSS;produce the message of A and ABIS
interface:establish the signaling link to CCM and SVICM
Manage the database of BSS,include the parameters of BSS
system,ground circuit resource,traffic channel resource,calling
record,performances record,handoff record and so on.
Hardware feature of CPM
According to the software function of CPM,CPM
should have the Hardware features below :
CPS sub-system is a joint point of BSS system’s resource management and call signaling
protocol processing,processing all the signaling,so the CPM should be powerful.
The CPM is 1+1 hot standby
PAM Functions
monitor the running status of the power supply
modules in the BSC-side frames and the equipment room
environment signals, including temperature, humidity,
smoke, and so on.
report the result to the background operation and
maintenance console through the NCM for processing;
provides duplex RS232 and RS485 interfaces for the
connection of external monitoring devices and alarm
box.
CDSU Subsystem
1. Convert signal between RS-422 interface and
non-channelized E1,transfer signaling and
traffic data between BSC and BTS.
2. BSC-CDSU and BTS-CDSU, have the same
hardware structure
Timing Subsystem
According to the CDMA standard,BSC and BTS independently synchronization the
timing signal provided by GPS.

Timing subsystem provides such timing signal:


* PP2S
* 16chips : 19.6608MHz
* TOD message
Timing distributing of BSC
1.2288MHz,PP2S 1.2288MHz,PP2S,
1.2288MHz,
19.6608MHz, ,Tod,Tx_clock, CPM 8kHz,2MHz,50Hz,
PP2S,Tod
10MHz,PP2S, Rx_clock Tod
Tod
NCM
S V IC M SVM
NCM N IM
GPS G
TM P T H IR S 1
S C
T M
M NCM
GPS B N IM S V IC M SVM
TM P NCM
H IR S 2

1.2288MHz,PP2S BSC _CD S 1.2288MHz,PP2S,


19.6608MHz, ,Tod,Tx_clock, U 8kHz,2MHz,50Hz,
1.2288MHz,
10MHz,PP2S, Rx_clock Tod
PP2S,Tod
Tod