One (1) (Q.T.) for every 10,000 kgs or fraction thereof for
each size
Test Specimen :
Variation in Mass, % :
DPWH Specification:
Variation in Mass, % : Shall not exceed 6% under nominal weight
except for bars smaller than 3/8 in. (10 mm)
plain round. In no case shall the overweight
be the cause for rejection.
Weight measurement per meter length of steel bar
2. Determination of Tensile Properties
Elongation Requirements:
Bar Designation No. / mm Grade 280(40) Grade 420 (60) Grade 520(75)
No. 3 ( 10 ) 11 9 -
No. 4, 5 ( 13, 16 ) 12 9 -
No. 6 ( 19 ) 12 9 7
No. 7, 8 ( 22, 25 ) - 8 7
No. 9,10,11 ( 29, 32, 36 ) - 7 6
No. 14, 18 ( 43, 57 ) - 7 6
Bending Requirement No cracking on outside bent
Footnotes:
10
AASHTO M 31 : NOMINAL DIMENSIONS
Nominal Dia. Nominal Mass Nominal Cross-
mm kg/m Sectional Area, mm2
10 0.560 71
12 0.994 129
16 1.552 200
20 2.235 284
22 2.042 387
25 3.973 510
28 4.960 645
32 6.403 819
36 7.906 1006
PHILIPPINE NATIONAL STANDARD PNS 49: 2000
SPECIFICATION FOR STEEL BARS FOR CONCRETE REINFORCEMENT
Strength Requirements:
MINIMUM TENSILE STRENGTH, Mpa MINIMUM YIELD STRENGTH, Mpa
GRADE
Non - Weldable Weldable Non - Weldable Weldable
Elongation Requirements:
PERCENT ELONGATION
GRADE BAR DIAMETER, mm
NON – WELDABLE WELDABLE
230 < 25 mm 18 20
≥ 25 mm 16 18
275 < 25 mm 10 16
≥ 25 mm 8 14
425 < 25 mm 8 14
≥ 25 mm 7 12
PHILIPPINE NATIONAL STANDARD PNS 49: 2000
SPECIFICATION FOR STEEL BARS FOR CONCRETE REINFORCEMENT
Dimensional Properties
Nominal Diameter, mm
Parameters
10 12 16 20 25 28 32 36 40
Nominal Unit Mass, kg/m 0.616 0.888 1.578 2.466 3.853 4.834 6.313 7.990 9.865
Nominal X-Sect. Area, mm2 78.54 113.10 201.06 314.16 490.88 615.75 804.25 1017.88 1256.64
Max. Ave. Spacing, mm 7.0 8.4 11.2 14.0 17.25 19.6 22.4 25.2 28.0
Min. Lug Height, mm 0.4 0.5 0.7 1.0 1.2 1.4 1.6 1.8 2.0
Max. Lug Height, mm 0.8 1.0 1.4 2.0 2.4 2.8 3.2 3.6 4.0
Max. Summ. Of Gaps, mm 7.8 9.4 12.6 15.7 19.6 22.0 25.1 27.5 31.41
Variation in Mass, % ± 6 ± 6 ± 6 ±6 ± 6 ± 6 ± 6 ± 6
± 6
Note : * Tensile srength shall not be less than 1.25 times the actual yield strength. TS / TY for
Weldable ≥ 1.25
DPWH Specification:
DPWH Specification:
T. Urmaza
S. Orate CLARITA C. FLORES
J. Tagalo Engine e r V
J. B e rgonio
C. de la Cruz ATTESTED :
Witnessed by:
Const. Of 2 Storey RGR Type Sch. Bldg. At Dona Ma. Platon Laurel, Aya, Talisay, Bats.
Project : Const. Of Circumferential Road Around Lake Taal, Agoncillo, Bats.
Completion of Aya-Tranca-Talisay Road, Talisay, Bats.
Kind of material : Reinforcing Steel Bar ( 16 mm dia., deformed )
Sample identification : DMP- 5
Quantity represented : 10,000 kgs.
Sampled at : Stockpile at jobsite
Original source : Top Steel
Supplied by : Revere Construction & Supply
Proposed use : for concrete reinforcement
Spec's Item No. : PNS 49 Grade 275 NW
Sampled by : F. Opena,Lab. Tech. II DPWH-Bats. 3rd DEO 06-08-06
(Name & designation) (Office) (Date)
Submitted by : Ma. B. M. Marquez - do - 6-14-06
(Name & designation) (Office) (Date Received)
Lab. No. : 1718-06 ( Paid under OR No. 2595342 )
Witnessed by:
Retests
If any tensile property of any tension test specimen is less than
that specified, and any part of the fracture is outside the middle
third of the gage length, as indicated by scribe scratches marked
on the specimen after testing, a retest shall be allowed.
Retests
If a weight ( mass ) test fails for reasons other than flaws in the
specimen, a retest shall be permitted on two random specimens
from the same lot. Both retest specimens shall meet the
requirements of the specification.
CONCRETE HOLLOW BLOCKS (CHB)
SPECIFICATIONS FOR CONCRETE HOLLOW BLOCKS ( CHB )
ASTM C-90 : LOAD BEARING CONCRETE MASONRY UNITS
Strength Requirements:
Individual - 5.5 Mpa (800 psi) Minimum
Average - 6.9 Mpa (1000 psi) Minimum
Absorption - 240 kg/m3 Maximum
Strength Requirements:
Gross Cross Sectional Area of the Unit, mm2 = is the total area of a
section perpendicular to the direction of the load,
including areas within cells.
Compression test of Concrete Hollow Block (CHB)
Dimension measurement of Concrete Hollow Block (CHB)
30
DETERMINATION OF ABSORPTION AND MOISTURE CONTENT
OF CONCRETE MASONRY UNITS
Significance
Absorption and moisture content tests of concrete masonry units are performed so as to
determine the actual percentage of water and the absorption characteristic of the
concrete when subjected in a saturated condition. The values of this are necessary in the
evaluation relative to its permissible value of acceptance.
1. Three (3) full size units shall be used and taken from six (6) units
selected from each lot of 10,000 units or fraction thereof.
Weighing and soaking of CHB specimen for Absorption test
Absorption test of Concrete Hollow
Block (CHB)
WORK SHEET FOR TESTS ON CONCRETE HOLLOW BLOCKS
Project __________________________________________________________________________________________
Proposed use ______________________________________ Spec’s Item No. _________________________________
Tested by__________________________________________ Computed by __________________________________
Lab. _______________(Name and designation) (Date) (Name and designation) (Date)
Sample Identification 1 2 3
1. Width, mm - - - - - - - - - - - - 150 150 150
2. Length, mm - - - - - - - - - - - 400 400 400
3. Height, mm - - - - - - - - - - - 200 200 200
4. Gross-cross sectional area, mm - - 60,000 60,000 60,000
5. Compressive Strength:
Ultimate Load, kg 66,000# 76,000# 67,000#
Compressive Strength, MN/m2
4.9 5.6 5.0
Compressive Strength, MN/2 (Avg. of 3 units)
5.2
L. Casanova
T. Urmaza CLARITA C. FLORES
S. Orate Engine e r V
J. Bergonio ATTESTED:
J. Tagalo
Witne s s e d by :
B ASILIA S. VILLANUEVA
Engine e r IV JUDY F. SESE
OIC, B ure au Dire ctor
REINFORCED CONCRETE CULVERT PIPE (RCCP)
Reinforced Concrete Pipe is manufactured into five (5) classes:
Class D-Load to D-Load to Concrete Strength, Concrete Strength,
produce a 0.03 produce the Mpa MPa
mm crack, ultimate load
Newton/lm/mm Newton/lm/m Wall A Wall B
of diameter m of diameter
I 40.0 60.0 27.6 Mpa (4000 psi) 27.6 Mpa (4000psi)
II 50.0 75.0 27.6 Mpa (4000 psi) 27.6 Mpa (4000 psi)
III 65.0 100.0 27.6 Mpa (4000 psi) 27.6 Mpa (4000 psi)
IV 100.0 150.0 34.5 Mpa (5000 psi) 27.6 Mpa (4000 psi)
V 140.0 175.0 41.4 Mpa (6000 psi) 41.4 Mpa (6000 psi)
Basis of Acceptance:
Load Bearing Test - shall be determine by the results of :
a. three –edge bearing tests to produce a 0.3 mm crack and the ultimate
load (strength) of the pipe
b. Absorption test on selected samples of concrete from the wall of the pipe
c. Visual inspection of the finished pipe to determine its conformance with
the accepted design and its freedom from defects.
Standard Specification for Reinforced Concrete Culvert Pipe
AASHTO M 170M – 94 or ASTM C 76M -
90aCLASS II REINFORCED CONCRETE PIPE - WALL B
DESIGN REQMTS. 600 mm 750 mm 900 mm 1050 mm
1200 mm
Internal Diameter, mm 600 - 620 750 – 775 900 – 925 1050 – 1080 1200 - 1230
Length, mm 990 min. 990 min. 990 min. 990 min. 990 min.
REINFORCEMENT
Spacing, mm 100 max. 100 max. 100 max. 150 max. 150 max.
Alternative Requirements:
- 1 - set consisting of 3 cylinder samples -
For not more than 25 pipes cast in the field
- 1 – Inspection Report for each size for not more
than 25 pipes cast in the field
- For cement, fine aggregate and water – testing is
sample for Item 405 (Structural Concrete)
41
TESTS ON RCCP AND SIGNIFICANCE
- Proof of design
Absorption Test
Significance :
The crushing test can be either a quality control test performed to
establish that the finished pipe has sufficient strength to withstand
the crushing loads stated in the specifications or a proof of design
testing performed to prove the adequacy of design.
Record the load to produce a 0.3 mm crack. The 0.3 mm crack load is the
maximum load applied to the pipe before a crack having a width
of 0.3 mm occurs throughout a continuous length of 300 mm or
more measured parallel to the longitudinal axis of pipe barrel.
WORK SHEET FOR TEST ON CONCRETE PIPE
Project ______________________________________________________________________________________
Sample identification _________________________Quantity represented ________________________
Original source ______________________________Supplied by ________________________________
Tested by __________________________________ Computed by _______________________________
==============================================================
=====================
Lab. No. _________________
Dimensions:
1. Actual internal diameter, mm - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -- 600
2. Thickness of wall, mm - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 85
3. Laying length, mm - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1000
3a. Laying length, m - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1
Strength Test
4. Load to produce 0.3 mm crack, kg - - - - - - - - - - - - - - - - - - - - - - - - - - - ------ - - - - - - - 3410
5. Ultimate load, kg - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5681
Reinforcement:
Type of reinforcement: Circular _______________________ Elliptical ______________________
6. Diameter, mm - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 5.29
7. No. of lines - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1
8. No. of hoops - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13
9. Spacing, mm - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 80
10. Net protective covering, mm - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - ----- 40
Absorption Test
Computation
Strength:
(4) X (9.8) 3410 x 9.8
Load to produce 0.3 mm crack /m/mm = --------------- = --------------- = -- 56
(3a) x (1) 1 x 600
Absorption, %
Proje ct :
Subic Port Development Project - SBMA
Kind and Clas s :
RCCP 750 mmØ Circular Class IV Wall B
Quantity re pre s e nte d :
50 pcs.
Sample d at :
Supermix Redi-Concrete Casting Yard
Original s ource :
Supermix Redi-Concrete
Propos e d us e :
Access Road
Spe c's Ite m No. :
ASTM C-76 M Class IV Wall B
Sample d by :
R. Benito-Engrs. Rep. PCI 10-23-04
(Name & de s ignation) (Office ) (Date )
Submitte d by : R. Testado- not stated A.M. Oreta & Co., Inc. 11-8-04
(Name & de s ignation) (Office ) (Date re ce ive d)
Lab. No. : 5990-04 (Paid under OR # 3708704)
Proje ct :
Subic Port Development Project - SBMA
Kind and Clas s :
RCCP 750 mmØ Circular Class IV Wall B
Quantity re pre s e nte d :
50 pcs.
Sample d at :
Supermix Redi-Concrete Casting Yard
Original s ource :
Supermix Redi-Concrete
Propos e d us e :
Access Road
Spe c's Ite m No. :
ASTM C-76 M Class IV Wall B
Sample d by :
R. Benito-Engrs. Rep. PCI 10-23-04
(Name & de s ignation) (Office ) (Date )
Submitte d by : R. Testado- not stated A.M. Oreta & Co., Inc. 11-8-04
(Name & de s ignation) (Office ) (Date re ce ive d)
Lab. No. : 5990-04 (Paid under OR # 3708704)