Professional Documents
Culture Documents
Version 1.1
Chris Lueth
Principal TME
September 2016
1 2016 NetApp, Inc. All rights reserved. --- NETAPP CONFIDENTIAL ---
Topics covered in order
5) FAS2600 software
6) Environmentals
Power consumption, cooling, dimensions, and weight
2 2016 NetApp, Inc. All rights reserved. --- NETAPP CONFIDENTIAL ---
Introducing two FAS2600 models
Next-generation midrange platform
FAS2620
2U 12-disk enclosure
SSD and SATA
FAS2620A
Replaces FAS2554
FAS2650
2U 24-disk enclosure
SSD and SAS
FAS2650A
Replaces FAS2552
3 2016 NetApp, Inc. All rights reserved. --- NETAPP CONFIDENTIAL ---
FAS2600: next-generation midrange platform
4 2016 NetApp, Inc. All rights reserved. --- NETAPP CONFIDENTIAL ---
Introducing the FAS2600
HA pairs
Whats New Compared to FAS2500
3x performance improvement
12 CPU cores: 3x more physical cores
64GB memory: ~2x more memory
8GB NVMEM: 2x more NVMEM
500000
400000
IOPS
300000
200000
100000
0
FAS2552 FAS2600 FAS8040 FAS8200 FAS8080 EX FAS9000
6 2016 NetApp, Inc. All rights reserved. --- NETAPP CONFIDENTIAL ---
Next-generation controller performance
HA pairs
250000
200000
IOPS
150000
100000
50000
0
FAS2552 FAS2600 FAS8040 FAS8200 FAS8080 EX FAS9000
7 2016 NetApp, Inc. All rights reserved. --- NETAPP CONFIDENTIAL ---
Next-generation controller performance
HA pairs
18
16
14
12
GBps
10 NFS
FC
8
0
FAS2552 FAS2600 FAS8040 FAS8200 FAS8080 EX FAS9000
8 2016 NetApp, Inc. All rights reserved. --- NETAPP CONFIDENTIAL ---
Next-generation controller performance
HA pairs
4
GBps
NFS
FC
3
0
FAS2552 FAS2600 FAS8040 FAS8200 FAS8080 EX FAS9000
9 2016 NetApp, Inc. All rights reserved. --- NETAPP CONFIDENTIAL ---
Next-generation FAS systems at a glance
HA pairs
FAS2552 FAS2600 FAS8040 FAS8200 FAS8080 EX FAS9000
Form factor 2U 6U 3U 12U 8U
CPU cores 4 (8 with HT) 12 16 32 40 72
Onboard 10GbE - 4 8 4 8 -
Onboard UTA2 8 8 8 8 8 -
Onboard 10GbE Base-T - - - 4 - -
Onboard GbE 4 - 8 - 8 -
Onboard SAS 4 (6Gb) 4 (12Gb) 8 (6Gb) 8 (12Gb) 8 (6Gb) -
Slots - - 8 4 24 24
NAS SAN
Heterogeneous (Mixed) Clusters1 Max Cluster Max Cluster
Nodes Nodes
AFF A300
FAS8200
FAS2552, FAS2554 8 8
FAS/V3220, FAS/V3250, FAS/V3270
AFF8020, FAS8020
FAS22xx, FAS2520 4 4
1. See Hardware Universe for more details about platform mixing rules.
11 2016 NetApp, Inc. All rights reserved. --- NETAPP CONFIDENTIAL ---
Flash limits
HA pairs
FAS2600
12 2016 NetApp, Inc. All rights reserved. --- NETAPP CONFIDENTIAL ---
FAS2600 aggregate and volume sizes
FAS2600
13 2016 NetApp, Inc. All rights reserved. --- NETAPP CONFIDENTIAL ---
Supported back-end storage
Shelf Module
DS224C IOM12
DS212C IOM12
IOM6
DS2246
IOM12
IOM6
DS4246
IOM12
14 2016 NetApp, Inc. All rights reserved. --- NETAPP CONFIDENTIAL ---
In-band SAS management
15 2016 NetApp, Inc. All rights reserved. --- NETAPP CONFIDENTIAL ---
FAS2600 HA configuration
Take a closer look
16 2016 NetApp, Inc. All rights reserved. --- NETAPP CONFIDENTIAL ---
FAS2600 controller close-up
Take a closer look
17 2016 NetApp, Inc. All rights reserved. --- NETAPP CONFIDENTIAL ---
FAS2600 controller I/O
Take a closer look
18 2016 NetApp, Inc. All rights reserved. --- NETAPP CONFIDENTIAL ---
FAS2600 motherboard image
Take a closer look
NVMEM Battery
19 2016 NetApp, Inc. All rights reserved. --- NETAPP CONFIDENTIAL ---
FAS2600 FRU map
Take a closer look
20 2016 NetApp, Inc. All rights reserved. --- NETAPP CONFIDENTIAL ---
FAS2600 block diagram
Take a closer look
21 2016 NetApp, Inc. All rights reserved. --- NETAPP CONFIDENTIAL ---
FAS2600 NVMEM architecture
Offers persistent write cache for write data not committed to drives:
No need to worry about minimum 72-hour battery life to protect NVMEM data
Previously only midrange and high-end FAS systems had this ability
22 2015 NetApp, Inc. All rights reserved. NetApp Confidential -- Limited Use
FAS2600 NVMEM destage/restage
***********************************
* Pending cached data is detected *
* Starting the process to save to *
* media... *
***********************************
Destage is in progress, please wait
.....................
Destage is completed successfully
Powering off from the backup power source
23 2016 NetApp, Inc. All rights reserved. --- NETAPP CONFIDENTIAL ---
FAS2600 hot-swappable FRUs
PSUs
One PSU can run entire system
Two-minute shutdown rule if one PSU removed
See slide 39 for more details
24 2016 NetApp, Inc. All rights reserved. --- NETAPP CONFIDENTIAL ---
Unified Target Adapter 2 (UTA2) ports
Overview
Adapter port will Mode options are FC and FC supports target Pending changes
always show the FC CNA. Use CNA for 1GbE or types. require reboot to
label name, even in 10GbE mode for NAS, iSCSI, CNA supports target take effect.
1GbE or 10GbE and FCoE. type.
mode. Note: Port pairs must have
the same mode.
26 2016 NetApp, Inc. All rights reserved. --- NETAPP CONFIDENTIAL ---
UTA2 transceivers
GbE SFP part number
X6567-R6: SFP optical 1GB shortwave multimode
X6568-R6: SFP copper 1GB RJ-45
NFS, CIFS, iSCSI supported; FCoE not supported
Not supported for cluster interconnects
Same ASIC set to Ethernet can have GbE and 10GbE SFP+ installed
GbE and 10GbE SFPs can be used on same ASIC
10GbE
X6589-R6: XCVR, SFP+, optical, 10GbE, shortwave
GbE and 10GbE SFPs can be used on same ASIC
16GB FC
X6596-R6: XCVR, SFP+, optical, 16Gb, FC, shortwave
Autoranges between 4Gb, 8Gb, and 16Gb
You do not have to disable FCoE driver if not using the protocol
FCoE network chatter fixed in ONTAP 9
28 2015 NetApp, Inc. All rights reserved. NetApp Confidential -- Limited Use
FAS2600 cluster interconnects
Switch CN1610 for most use cases with more than two nodes in cluster
Can use UTA2 ports for cluster interconnects with 10GbE SFP+
Recommend e0e and e0f
29 2015 NetApp, Inc. All rights reserved. NetApp Proprietary Limited Use Only
Supported I/O cables on FAS2600
30 2016 NetApp, Inc. All rights reserved. --- NETAPP CONFIDENTIAL ---
Using the onboard USB boot port
The external USB port is only enabled during these activities, and
its activation is based on specific commands
Requires USB devices have FAT32 formatting
31 2015 NetApp, Inc. All rights reserved. NetApp Confidential -- Limited Use
USB port use cases
32 2016 NetApp, Inc. All rights reserved. --- NETAPP CONFIDENTIAL ---
FAS2600 software and firmware levels
33 2016 NetApp, Inc. All rights reserved. --- NETAPP CONFIDENTIAL ---
Service processor
Enhances manageability and RASM
34 2016 NetApp, Inc. All rights reserved. --- NETAPP CONFIDENTIAL ---
System-level diagnostics
SLDIAG
35 2016 NetApp, Inc. All rights reserved. --- NETAPP CONFIDENTIAL ---
FAS2600 cooling architecture
PSU blowers provide cooling for power supplies, controllers, and disks
Air flows in through disks, then splits between power supplies and PCMs
Standalone controllers must have a blank installed in PCM bay to make sure of
proper cooling
36 2016 NetApp, Inc. All rights reserved. --- NETAPP CONFIDENTIAL ---
FAS2600 power architecture
Blowers powered using backplane and will continue to run if PSU fails
Leave failed PSU in place until replacement arrives
FAS2600 will shut down if a PSU is removed for more than 2 minutes
Data ONTAP initiates the shutdown
37 2016 NetApp, Inc. All rights reserved. --- NETAPP CONFIDENTIAL ---
FAS2600 environmental details
Power, thermals, weight, dimensions
Hardware Universe
(https://hwu.netapp.com)
38 2016 NetApp, Inc. All rights reserved. --- NETAPP CONFIDENTIAL ---
FAS2600 dimensions and weight
Metric English
Height 2U
39 2016 NetApp, Inc. All rights reserved. --- NETAPP CONFIDENTIAL ---
FAS2600 acoustics
40 2016 NetApp, Inc. All rights reserved. --- NETAPP CONFIDENTIAL ---
FAS2600 certification information1
Type Country Test Standards Notes
Safety US 60950-1
CAN CAN/CSA-22-2 NO.60950-1 Equivalent to UL 60950
EU EN 60950-1
Emission US FCC part 15, Subpart B, Class A FCC Class A minimum
CAN ICES-003
EU EN 55022, Class A Emission of ITE
CISPR22
EN 61000-3-2 AC Line Harmonic
EN 61000-3-3 AC Line Flicker
Immunity US N/A
CAN N/A
EU EN 55024 Immunity of ITE
EN 61000-4-2 ESD
EN 61000-4-3 RF
EN 61000-4-4 Fast Transient
EN 61000-4-5 Surge
EN 61000-4-6 Conducted
EN 61000-4-11 Line Dip/ Interrupt
1) Information about EMI certifications.
41 2016 NetApp, Inc. All rights reserved. --- NETAPP CONFIDENTIAL ---
Thank you