BFC21502
SESSION 4
GROUP 5
OK! -0.0001 0
4. Back sight and foresight reading has been recorded for the
second setup.
5. Steps 1-4 were repeated and continue until TBM2 and from
TBM 2 were back to TBM 3 and closed the levelling loop.
RESULT
REDUCED CORRECT DISTANCE NOTE
BS IS FS ED
RISE FALL LEVEL ION (S) S
RL
1.400 1.690 0 1.690 0 TBM3
TBM3
1.255 1.398 0.002 1.692 - 0.001 1.692 15
A
1.226 1.235 0.020 1.712 - 0.002 1.714 30 TBM4
1.585 1.300 0.074 1.638 - 0.003 1.641 68 TBM7
1.658 0.073 1.565 - 0.003 1.568 89 TBM5
1.126 1.542 0.116 1.681 - 0.004 1.685 112 TBM6
1.550 0.425 1.256 - 0.004 1.260 146 BM1
1.555 1.395 0.155 1.411 - 0.005 1.416 181 TBM8
1.635 1.395 0.160 1.571 - 0.006 1.577 202 TBM9
- 0.007 TBM1
1.294 1.410 0.225 1.796 1.803 225
0
1.585 1.531 0.237 1.559 - 0.007 1.566 259 TBM2
1.462 0.123 1.682 - 0.008 1.690 293 TBM3
=
= 12.66 = 12.668 = 0.800
0.809
ALa=1.682
BS FS ALc=1.690
Rise fall
=12.66 ALa Alc
=0.801-0.809
12.668 =1.682
=-0.008
=-0.008 1.69
=-0.008
ANALYSIS RESULT
CALCULATION CHECKING:
CORRECTION = MISCLOSURE/NO.BS
- 0.008/9 = - 0.0008
HSK = 20 D
= 20 0.293
= 10.826mm
DISCUSSION
There are some errors during the levelling.
Reading of staff
Bubble not being central
Instrument not being in adjustment
Differential settlement of the tripod
Tilting and settlement of the staff
Sensitivity of bubble or compensator
CONCLUSION
From the levelling work, we figure out that
difference result that we get still in the range of the
allowable difference limit.