Physical Architecture

PE/TRD/CN/0303 12.02/EN March, 2000 Physical Architecture 4-1


Objectives

This section shows a typical hardware architecture of an OMC-R installation. It describes step by step
the hardware features of all the component pieces of equipment in this architecture.
It deals with the following aspects:
Main equipment
Servers:
- Equipment
"Confidential information -- may not be copied or disclosed without permission".

- Connections
Workstations:
- Equipment
- Connections
- X terminals
- ROT
Peripheral equipment
OMC-R printer
Routers
Terminal server
Modems
Hub
X.25 switch
Optional equipment
Firewall
Alarm relay
Line Mode via Xyplex
UPS
Different ethernet connections

PE/TRD/CN/0303 12.02/EN March, 2000 Physical Architecture 4-2


Contents

General Hardware Description


"Confidential information -- may not be copied or disclosed without permission".

Several Server Configurations

Main Equipment

Peripheral Equipment

Optional Equipment

Different Ethernet Connections

PE/TRD/CN/0303 12.02/EN March, 2000 Physical Architecture 4-3


General Hardware Description (1/2)
ROT

Local Local
Local workstation workstation
X workstation Printer PCU OAM Server PSTN
Terminal SDO

Terminal server
+ modems
"Confidential information -- may not be copied or disclosed without permission".

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

Ethernet LAN Display Display Ethernet/X.25


unit unit MA E LAN

E4XXX Router
Alarm OMC-R Alarm
relay servers relay BSS2
Agprs
Serial link

X.25 NETWORK
BSC
Optical fiber
PCUSN
Router BSS3
StorEdge A5000
BSS1
Sun
StorEdge A5000

Remote
workstations

PE/TRD/CN/0303 12.02/EN March, 2000 Physical Architecture 4-4


General Hardware Description (2/2)
ROT

Local Local
Local workstation workstation
X workstation Printer PCU OAM Server PSTN
Terminal SDO

Terminal server
+ modems
"Confidential information -- may not be copied or disclosed without permission".

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

Ethernet LAN Display Display Ethernet/X.25


unit unit MA E LAN

E4XXX Router
Alarm OMC-R Alarm
relay servers relay BSS2
Agprs
Serial link

X.25 NETWORK
BSC
Optical fiber
PCUSN
Router BSS3
StorEdge A5000
BSS1
Sun
StorEdge A5000

Remote
workstations

PE/TRD/CN/0303 12.02/EN March, 2000 Physical Architecture 4-5


Several Server Configurations
Nominal Configurations

E4500 Bi-server Configuration E4500 Single server Configuration


30 BSCs 2400 cells (HC: High Capacity) 30 BSCs 2400 cells (HC)
"Confidential information -- may not be copied or disclosed without permission".

20 BSCs 1600 cells (SC: Standard Capacity) 20 BSCs 1600 cells (SC)
E4500 E4500 E4500

Optical Optical
Fiber Fiber

Sun StorEdge A5000 Sun StorEdge A5000

A5000 A5000

PE/TRD/CN/0303 12.02/EN March, 2000 Physical Architecture 4-6


Several Server Configurations
Other Configurations
E4000 Bi-server Configuration
30 BSCs 2400 cells (HC)
E4000 Bi-server Configuration 20 BSCs 1600 cells (SC)
20 BSCs 1600 cells (SC)
E4000 E4000
E4000 E4000
"Confidential information -- may not be copied or disclosed without permission".

Optical
Fiber Optical
Fiber
Sun StorEdge A5000
SSA SSA
Sun SPARCstorage Array Sun SPARCstorage Array
A5000

E4000 Single server Configuration


S1000 Bi-server Configuration 30 BSCs 2400 cells (HC)
20 BSCs 800 cells 20 BSCs 1600 cells (SC)

S1000 S1000 E4000

Sun StorEdge A5000


SunSparc 1000E SunSparc 1000E
A5000
PE/TRD/CN/0303 12.02/EN March, 2000 Physical Architecture 4-7
"Confidential information -- may not be copied or disclosed without permission".

PE/TRD/CN/0303 12.02/EN
March, 2000
Physical Architecture
4-8
"Confidential information -- may not be copied or disclosed without permission".

PE/TRD/CN/0303 12.02/EN
March, 2000
Physical Architecture
Main Equipment

4-9
Main Equipment
Physical Description of the E4500 OMC-R Server

Monitoring link
to second server Ethernet/10baseT
if it exists
TTYB
Console
"Confidential information -- may not be copied or disclosed without permission".

Sun
E4500

Port 0

HSI Port 1

Port 2

Port 3
Optical
Fiber
StorEdge A5000
To X.25 modem

(OMN)

E4500 with 1 GB of RAM HC: 30 BSCs 2400 cells


Sun
A5000 22 slots 81 GB
StorEdge A5000

E4500 with 512MB of RAM SC: 20 BSCs 1600 cells


A5000 22 slots 81 GB
PE/TRD/CN/0303 12.02/EN March, 2000 Physical Architecture 4-10
Main Equipment
Physical Description of an A5000
"Confidential information -- may not be copied or disclosed without permission".

PE/TRD/CN/0303 12.02/EN March, 2000 Physical Architecture 4-11


Main Equipment
E4500 Server Connections
Ultra Entreprise 4000
Power Rear view
cooling Alarm Keyboard
modules UPS Terminator management unit
To second
server

Processor
board

Screen
"Confidential information -- may not be copied or disclosed without permission".

Clock board
SBUS board
SCSI-2 B= A=

Disk board

Fibre channel to
SSAA or SSAB

HSI Ethernet RJ45 Ethernet Fast/wide


SCSI-2
HSI/S port distribution cable

Port 0 Port 1 Port 2 Port 3 SCSI


Terminator

10 Base T Hub

RS449

Blackbox Blackbox 37-pin SubD


RS449/V35 RS449/V35 connectors

V35
Twisted pair
X.25 Network modem

PE/TRD/CN/0303 12.02/EN March, 2000 Physical Architecture 4-12


Main Equipment
Physical Description of the E4000 OMC-R Server
Monitoring link
to second server Ethernet/10baseT

TTYB
Console
"Confidential information -- may not be copied or disclosed without permission".

Sun
E4000

HSI

Port 0

Port 1

Port 2
Optical Fiber
SSA SSA Port 3

To X.25 modem
(OMN)

Sun SPARCstorage Array Sun SPARCstorage Array

E4000 and 2* SSAs SC: 20 BSCs 1600 cells

E4000 400 MHz, 1 GB of RAM and A5000 22 slots 81 GB HC: 30 BSCs 2400 cells
PE/TRD/CN/0303 12.02/EN March, 2000 Physical Architecture 4-13
Main Equipment
Physical Description of the S1000 Server

Ethernet/10baseT
"Confidential information -- may not be copied or disclosed without permission".

Sparc 1000
Sun

CD-ROM
drive
Console
Gigatape
HSI
Multidat Port 0
Sun Sparc 1000E
Port 1

ON/OFF
Key Port 2 To X.25 modem
TTYB (OMN)
Port 3

Monitoring link
to second server

PE/TRD/CN/0303 12.02/EN March, 2000 Physical Architecture 4-14


Main Equipment
Sparc 1000 Server Connections
SPARCserver 1000
Rear view SCSI-2 plug
To second server
monitoring link Keyboard
Processor To alarm supervision box
board

Mother board

1 0
"Confidential information -- may not be copied or disclosed without permission".

Color
monitor

SCSI
termination

UPS Disk SCSI-2


board termination

HSI/S port distribution

Port 0 Port 1 Port 2 Port 3

10 Base T Hub

RS449

Blackbox Blackbox 37-pin SubD


RS449/V35 RS449/V35 connectors

V35
Twisted pair
X.25 Network modem

PE/TRD/CN/0303 12.02/EN March, 2000 Physical Architecture 4-15


Main Equipment
Physical Description of an OMC-R Workstation
Ethernet
(only for the SPARC5)

Transceiver

Hub
"Confidential information -- may not be copied or disclosed without permission".

or

20" color monitor

DAT tape drive

Floppy drive CD-ROM drive

PE/TRD/CN/0303 12.02/EN March, 2000 Physical Architecture 4-16


Main Equipment
OMC-R Workstation Connections
Color Monitor (Rear view)
Keyboard / Mouse
"Confidential information -- may not be copied or disclosed without permission".

Ultra 5 (System Unit)


(Rear view)

SCSI

Eth
(RJ45)
Mains connector
or UPS

Twisted
pair

Hub

DAT tape drive


(Rear view)

SCSI
SCSI I
220
O

SCSI plug
(bus termination)

PE/TRD/CN/0303 12.02/EN March, 2000 Physical Architecture 4-17


Main Equipment
X Terminal Equipment and Connections
Colour monitor
(rear view)
"Confidential information -- may not be copied or disclosed without permission".

Keyboard plug
HP ENVIZEX (system unit)(rear view)

10 parallel serial
Base T Thin AUI port port O
.
O

Video port

Mouse plug Power Supply

PE/TRD/CN/0303 12.02/EN March, 2000 Physical Architecture 4-18


Main Equipment
ROT Description

Minimum configuration
is
PC Laptop or Desktop 486 Processor
4 MB RAM
"Confidential information -- may not be copied or disclosed without permission".

25 MB Hard Disk
FDD 3.5" 1.44 Mb
VGA screen

COM 1 Recommended PC
or
COM 2
is
DELL Latitude Cpi:
Modem V34 128 MB RAM
PCMCIA 6.4 GB Hard Disk
FDD 3.5" 1.44 Mb
PSTN

Microsoft
mouse

PE/TRD/CN/0303 12.02/EN March, 2000 Physical Architecture 4-19


"Confidential information -- may not be copied or disclosed without permission".

PE/TRD/CN/0303 12.02/EN
March, 2000
Physical Architecture
4-20
"Confidential information -- may not be copied or disclosed without permission".

PE/TRD/CN/0303 12.02/EN
March, 2000
Physical Architecture
Peripheral Equipment

4-21
Peripheral Equipment
The OMC-R Printer
"Confidential information -- may not be copied or disclosed without permission".

Laser printer

PE/TRD/CN/0303 12.02/EN March, 2000 Physical Architecture 4-22


Peripheral Equipment
Physical Description of the BayStack Access Node Router
"Confidential information -- may not be copied or disclosed without permission".

Rear

RJ45 44 pins
serial port Power
AUI
console

PE/TRD/CN/0303 12.02/EN March, 2000 Physical Architecture 4-23


Peripheral Equipment
Physical Description of a CISCO Router

Front panel
"Confidential information -- may not be copied or disclosed without permission".

CISCO 2500
CISCOSYSTEM

Rear panel

AUI SERIAL SERIAL CONSOLE AUX I


CISCO 2501
O

DB-15 DB-60 RJ45 Main power


Ethernet access X.25 access
ON/OFF power

PE/TRD/CN/0303 12.02/EN March, 2000 Physical Architecture 4-24


Peripheral Equipment
XYPLEX Maxserver

Transceiver

XYPLEX Maxserver Ethernet


"Confidential information -- may not be copied or disclosed without permission".

CARD RUN LAN CONSOLE


1 2 3 4 5 6 7 8 9 10

Distribution
Panel
ROT

RS232C RS232C
o x >< x

OMC printer
(optional)
MODEMS PSTN

PE/TRD/CN/0303 12.02/EN March, 2000 Physical Architecture 4-25


Peripheral Equipment
XYPLEX Maxserver 1620

Reset

Front
CARD RUN LAN CONSOLE panel
"Confidential information -- may not be copied or disclosed without permission".

1 2 3 4 5 6 7 8 9 10

Self-test Ethernet System port activity


and run activity console
indicator session

Rear 110 - 240 VAC


1.0 - 0.5 A 50 - 60 Hz ETHERNET
panel 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

Main power 8-pins female RJ45 serial port connectors


supply input
sector

PE/TRD/CN/0303 12.02/EN March, 2000 Physical Architecture 4-26


Peripheral Equipment
Modems

Modem characteristics for ROT connection:


"Confidential information -- may not be copied or disclosed without permission".

Up to standard V22bis, V32bis, V34


Asynchronous duplex transmission
MNP4 error protocol
MNP5 data compression
Automatic protocol negotiation
Compatible AT Hayes commands

PE/TRD/CN/0303 12.02/EN March, 2000 Physical Architecture 4-27


Peripheral Equipment
BayStack 250

Cascade RS232
Power connectors
"Confidential information -- may not be copied or disclosed without permission".

LED 12 RJ45
Display Ethernet ports

MDI/MDI-X
switch

PE/TRD/CN/0303 12.02/EN March, 2000 Physical Architecture 4-28


Peripheral Equipment
Link Builder FMS 2 HUB

Transceiver

Connection to an eventual
10 Base 2 network
"Confidential information -- may not be copied or disclosed without permission".

Down cable Power supply

AUI plug

Connectors
RJ45

Equipment Twisted pair

PE/TRD/CN/0303 12.02/EN March, 2000 Physical Architecture 4-29


Peripheral Equipment
X.25 Switch

V11 cable Mainstreet


OMC-R
Passive 36111
server (ECOM)
HSI BSC
V24 BSC
"Confidential information -- may not be copied or disclosed without permission".

BSC
OMC-R
Active
server

interface boards

FEP 3 board FEP 3 board


FEP 2 board FEP 2 board

FEP 1 board FEP 1 board


POWER
SUPPLY
HPU board HPU board

36111 is rackable (19 cabinet) Interface boards type:


MPU: motherboard (HPU) + one FEP X.25/V35+V24 (2 +2 ports)
1 FEP handles 2 Interface boards (8links) X.25/V24 (4 ports)
I&C/Adm via OMC-R or VT V11 (4 ports) for U type only
PE/TRD/CN/0303 12.02/EN March, 2000 Physical Architecture 4-30
"Confidential information -- may not be copied or disclosed without permission".

PE/TRD/CN/0303 12.02/EN
March, 2000
Physical Architecture
Optional Equipment

4-31
Optional Equipment
ROT Firewall

PC ROT

PSTN
"Confidential information -- may not be copied or disclosed without permission".

Security PC
Modem ROT
MODEMS

Terminal
Server

Security PC
Ethernet

Local OMC-R WS OMC-R Server

PE/TRD/CN/0303 12.02/EN March, 2000 Physical Architecture 4-32


Optional Equipment
Relay Box
"Confidential information -- may not be copied or disclosed without permission".

REAR

Relay Relay Serial link Power Supply


connector connector 25 DB female Switch
37 DB female 37 DB female (inputs)

PE/TRD/CN/0303 12.02/EN March, 2000 Physical Architecture 4-33


Optional Equipment
Line Mode via Xyplex

Xyplex
"Confidential information -- may not be copied or disclosed without permission".

RS232 RS232

OMC-R OMC-R
server server Supervisory Workstations
(Active) (Passive)

LAN

Local OMC-R WS

PE/TRD/CN/0303 12.02/EN March, 2000 Physical Architecture 4-34


Optional Equipment
UPS
"Confidential information -- may not be copied or disclosed without permission".

Front view

Rear view

PE/TRD/CN/0303 12.02/EN March, 2000 Physical Architecture 4-35


Different Ethernet Connections

Existing network Connector Cable between machine


connector and network
Twisted pair RJ45
Twisted pair
"Confidential information -- may not be copied or disclosed without permission".

Ethernet thin Thin Ethernet

Coaxial cable

AUI 15 pts Down cable + Transceiver

Coaxial cable

PE/TRD/CN/0303 12.02/EN March, 2000 Physical Architecture 4-36


"Confidential information -- may not be copied or disclosed without permission".

PE/TRD/CN/0303 12.02/EN
March, 2000
Student Notes

Physical Architecture
4-37
"Confidential information -- may not be copied or disclosed without permission".

PE/TRD/CN/0303 12.02/EN
March, 2000
Student Notes

Physical Architecture
4-38

You might also like