You are on page 1of 32

TIPOS DE MEDIDORES

DE GAS
M E D ID O R E S D E M E D ID O R E S
D E S P L A Z A M IE N T O IN F E R E N C IA L E S
P O S IT IV O
M E D ID O R E S D E G A S
D E D E S P L A Z A M IE N T O
P O S IT IV O

M E D ID O R E S D E M E D ID O R E S
D IA F R A G M A R O T A T O R IO S
M E D ID O R E S D E G A S
IN F E R E N C IA L E S

M E D ID O R E S M E D ID O R E S
D E O R IF IC IO D E T U R B IN A
POSICIN TPICA DE UN MEDIDOR
DE ORIFICIO

10 DIMETROS DE TUBERA 5 DIMETROS


DE TUBERA

ALABS EN 5 DIMETROS
DE TUBERA
LNEA
PLACA DE ORIFICIO
POSICIN TPICA DE UN MEDIDOR DE
ORIFICIO CON RESTRICCIN DE
FLUJO EN LA TUBERA DE ENTRADA

10 DIM. DE
8 DIM. TUBERA 5 DIM.

RESTRICCIN ALABS PLACA DE


ORIFICIO
MEDICIN DE GAS CON MEDIDORES
DE TURBINA

INFORME N7 DEL COMIT DE AGA


REQUISITOS DEL GRUPO DE
MEDICIN

1 -AISLAMIENTO DEL TRAMO DE MEDICIN


2 -LNEA DE DERIVACIN
3 -SOPLADO DE LA PRESIN
4 -PRUEBAS EN LA LNEA
*5 -TOMA PARA PRESIN
*6 -TOMA PARA TEMPERATURA
*NOTA: SI SE REQUIERE
TEMPERATURAS DE OPERACIN
CONSTRUCCIN ESTNDARD

ACERO -40F hasta +65F


(-40C hasta +74C)

ALUMINIO -20F hasta +165F


HIERRO DCTIL (-29C hasta +74C)

NOTA: PARA TEMPERATURAS MS ALTAS SE REQUIERE UNA


CONSTRUCCIN ESPECIAL DE LOS MEDIDORES DE ACERO
PROBLEMAS DE CONTAMINANTES
MEDICIN EN CONDENSADOS
PRODUCCIN CORROSIN
CONTAMINANTES

SEPARADORES
FILTROS
GAS CIDO HMEDO
CONCENTRACIONES MXIMAS DE H2S

PRESIN PORCENTAJE
100psia = 0.05%
500psia = 0.01%
1000psia = 0.005%
INSTALACIONES DE LOS MEDIDORES
DE TURBINA
1 -CUMPLA CON LAS ESPECIFICACIONES PARA EL
TRAMO DEL MEDIDOR
2 -SE RECOMIENDA UN GIRO DE 90 EN EL FLUJO DE
ENTRADA
3 -PROVEA AISLAMIENTO DEL MEDIDOR Y LNEA DE
DERIVACIN
4 -PROPORCIONE ALIVIO CONTROLADO DE LA
PRESIN
5 -SI SE REQUIERE, INSTALE LA VAINA PARA EL
SISTEMA TERMOMTRICO CORRIENTES ABAJO DEL
MEDIDOR
Vm = Vc . Nc . Fp . Ft .Fpv2

DONDE:
Vm = VOLUMEN TOTALIZADO
Vc = VOLUMEN POR CICLO
Nc = NMERO DE CICLOS
Fp = FACTOR DE PRESIN
Ft = FACTOR DE TEMPERATURA
Fpv = SUPERCOMPRESIBILIDAD
MEDIDORES DE DIAFRAGMA

VENTAJAS DESVENTAJAS

RANGO EXCELENTE GRANDE


CONFIABLE Y DURABLE CAP.MX. 10000 PIE3/h
VARIOS TAMAOS DISPONIBLES ALTA PRESIN LIMITADA
GRAN VARIEDAD DE LECTURAS
MEDIDORES ROTATORIOS

VENTAJAS DESVENTAJAS

COMPACTOS FLUJO BAJO LIMITADO


CONFIABLES UNIDADES GRANDES PESADAS
VARIOS TAMAOS DISPONIBLES ALTA PRESIN LIMITADA
GRAN VARIEDAD DE LECTURAS ESPECIFICACIONES DE INSTALACIN
INFERENCIA: CONCLUSIN
DERIVADA DE EVIDENCIA

A PARTIR DE LA VELOCIDAD
SE INFIERE LA CANTIDAD DEL
VOLUMEN
Qh = C h w . Pf

DONDE:
Qh = VOLUMEN DE FLUJO A CONDICIONES
BSICAS (PIE3/h)
C = CONSTANTE DE FLUJO DEL ORIFICIO
Hw = PRESIN DIFERENCIAL EN PULGADAS DE
AGUA A 60F
Pf = PRESIN ESTTICA ABSOLUTA EN LIBRAS /
PULGADA
C = Fb . Fr . Y . Ftf . Ftb . Fg . Fpv . Fm . Fa . F1

DONDE:
Fb = FACTOR BSICO DEL ORIFICIO

Fr = FACTOR DEL NMERO DE REYNOLDS


Y = FACTOR DE EXPANSIN

Fpb = FACTOR DE LA PRESIN BASE

Ftb = FACTOR DE LA TEMPERATURA BASE

Ftf = FACTOR DE LA TEMPERATURA DE FLUJO

Fg = FACTOR DEL PESO ESPECFICO

Fpv = FACTOR DE SUPERCOMPRESIBILIDAD

Fm = FACTOR DEL MANMETRO (SLO PARA


MEDIDORES DE ORIFICIO

TRAMO DEL
MEDIDOR RANGO

UNA PLACA 3.5:1


DOBLE TRAMO 10.0:1

RANGOS PTIMOS INDEPENDIENTES DE LA PRESIN


MEDIDOR DE
ORIFICIO TURBO-MEDIDOR

FLUJO DE GAS
MEDIDORES DE TURBINA

VENTAJAS

BUEN RANGO
COMPACTO
FCIL DE INSTALAR
LECTURA DIRECTA DE VOLUMEN
GRAN VARIEDAD DE LECTURAS

DESVENTAJAS
Q=V.A

DONDE:

Q = VOLUMEN DE FLUJO EN PIE3/h


ENERGA CINTICA = ENERGA FSICA DE
LA MASA EN
MOVIMIENTO
KE = 1/2 MV2
DONDE:

KE = FUERZA DE IMPULSIN
M = MASA (PESO)
V = VELOCIDAD (TASA DE FLUJO)

MEDIDOR DE TURBINA TERICO


PARA UNA PRESIN CONSTANTE DE
ENTRADA, CUALQUIER AUMENTO EN
LA FRICCIN MECNICA AFECTA
SOLAMENTE LA PRECISIN A BAJO
FLUJO
FACTORES LIMITADORES DE LA
CAPACIDAD DEL MEDIDOR DE
TURBINA

A FLUJO BAJO = PRECISIN DEL +1%

A FLUJO ALTO = VIDA PTIMA DEL


MEDIDOR
OPERACIN DEL MEDIDOR DE
TURBINA A PRESIONES ELEVADAS

1-LA CAPACIDAD MXIMA EN PIES CBICOS


NORMALES POR HORA AUMENTA
DIRECTAMENTE AL IGUAL QUE EL FACTOR
MULTIPLICADOR DE PRESIN DE LA LEY DE
BOYLE
2-LA CAPACIDAD MNIMA (A FLUJO BAJO)
AUMENTA DIRECTAMENTE AL IGUAL QUE LA
RAZ CUADRADA DEL FACTOR MULTIPLICADOR
DE PRESIN DE LA LEY DE BOYLE
MEDIDORES DE ORIFICIO

TRAMO DEL RANGO


MEDIDOR

UNA PLACA 3.5:1


DOBLE TRAMO 10.0:1

RANGOS PTIMOS INDEPENDIENTES DE LA PRESIN


VENTAJAS DEL TURBO-MEDIDOR
NO HAY SUPRESIN ARTIFICIAL DE LA
CAPACIDAD MXIMA TERICA CUANDO SE
OPERAN LOS TURBOS A PRESIONES
ELEVADAS

LOS TURBO-MEDIDORES SON


RELATIVAMENTE LIGEROS DE PESO Y
PUEDEN SER MONTADOS EN LA
LNEA SIN SOPORTES EXTERNOS
LOS TURBO-MEDIDORES NO PUEDEN
CAUSAR PULSACIONES DE PRESIN EN
LA LNEA Y LA PARADA DEL MEDIDOR
NO CAUSA UNA INTERRUPCIN DEL
FLUJO

LOS TURBO-MEDIDORES SON


RELATIVAMENTE LIGEROS DE PESO Y
PUEDEN SER MONTADOS EN LA LNEA
SIN SOPORTES EXTERNOS
LOS TURBO-MEDIDORES PROPORCIONAN
UNA LECTURA DIRECTA INSTANTNEA DEL
VOLUMEN GASTADO A LAS CONDICIONES
DE LA LNEA

LOS TURBO-MEDIDORES PUEDEN SER


ADAPTADOS FCILMENTE PARA
PROPORCIONAR PULSOS DIGITALES DE
ALIMENTACIN PARA UNA GRAN VARIEDAD
DE APARATOS ACCESORIOS
ELECTRNICOS DE LECTURA
NO HAY SUPRESIN ARTIFICIAL DE LA
CAPACIDAD MXIMA TERICA CUANDO SE
OPERAN LOS TURBOS A PRESIONES
ELEVADAS

LOS TURBO-MEDIDORES SON


RELATIVAMENTE LIGEROS DE PESO Y
PUEDEN SER MONTADOS EN LA LNEA
SIN SOPORTES EXTERNOS

You might also like