You are on page 1of 14

A COMPARISSON OF

SYNCHRONOUS AND
NONSYNCHRONOUS
BOOST CONVERTER

Mohamad
Mohamad Isnaeni
Isnaeni Romadhon
Romadhon
Mochammad
Mochammad Facta
Facta
Trias
Trias Andromeda
Andromeda
BACKGROUND

MODERN ELECTRONIC SYSTEM INCREASE EFFICIENCY


PURPOSE

1. COMPARE THE CONDUCTION LOSS

2. COMPARE THE EFFICIENCY


NONSYNCHRONOUS BOOST CONVERTER

Schemetic Ideal Waveform


SYNCHRONOUS BOOST CONVERTER

Schematic Ideal Waveform


Input

Nonsynchronous Synchronous
Output

Nonsynchronous Synchronous
Result

Nonsynchronous Boost Converter Synchronous Boost Converter


Vin(rms) Iin(rms) Io(rms) Vin(rms) Iin(rms) Io(rms)
Vo(rms) Vo(rms)
Duty Cycle Duty Cycle
(%) (V) (A) (A) (%) (V) (A) (A)
(V) (V)

6,8 13,04 0,51 13,05 0,49 6,8 13,05 0,49 13,21 0,47
10 13,04 0,52 13,58 0,46 10 13,04 0,56 13,74 0,5
15 13,04 0,61 14,35 0,52 15 13,04 0,61 14,62 0,55
20 13,04 0,65 15,31 0,53 20 13,03 0,67 15,62 0,53
25 13,03 0,71 16,14 0,55 25 13,03 0,73 16,5 0,57
30 13,01 0,81 17,51 0,56 30 13,01 0,81 17,89 0,58
35 12,99 0,9 18,51 0,58 35 12,99 0,95 19,01 0,58
40 12,96 1,07 20,2 0,63 40 12,96 1,13 20,79 0,66
43,5 12,97 1,23 21,05 0,7 43,5 12,96 1,24 21,68 0,69
Comparisson of conduction loss

Duty cycle Conduction loss of Conduction loss of


(%) synchronous boost nonsynchronous
converter boost converter
(W) (W)

6,8 1,411719 0,531607

10 1,44159 0,50175

15 1,479826 0,575158

20 1,312618 0,595362

25 1,271958 0,63057

30 1,134797 0,658106

35 0,957773 0,704584

40 0,856632 0,804452

43,5 0,729494 0,943483


Efficiency comparisson of synchronous and nonsynchronous boost
converter

0.95

0.9

0.85

0.8 Duty cycle


6.8 10 15 20 25 30 35 40 43.5

MOSFET sinkronisasi Dioda


Conclusion

At the TL494 synchronous boost converter, the


efficiency linearly ramps up when duty cycle
increase. The efficiency was steady at anyvarious
duty cycle. The efficiency of synchronous boost
converter is greater than nonsynchronous when duty
cycle is more than 40%. These way affected by
synchronous topologys power dissipation, whose the
average will comes up when the duty dycle
minimized. Minimizing duty cycle will make deadtime
increases, so conduction loss of body diode at the
synchronous converter topology grown up. Selected
appropriate component at synchronous converter
topology will maximizing the efficiency.
Thank you