Professional Documents
Culture Documents
G-Eye
19'
1U
Datacenters and server facilities, cellular sites and countless other locations
require continuous electrical power to function properly. G-Eye enable you to
ensure and monitor the electrical supply at any location, and many other
parameters. G-Eye is the perfect solution, offering total flexibility and
protecting business continuity, and can even be the answer for a remote site
in the Amazon forest!
Environment
Extreme environmental changes can dramatically
affect the operating capabilities of electrical systems.
G-Eye solution:
The unit accepts input from multiple temperature
sensors, enabling real-time monitoring of
temperatures at a number of sites. Alarm thresholds
(high and low) can be custom configured for each
sensor. When the temperature reading passes above
or below the permitted range, the unit immediately
issues an alarm message to defined recipients, such
as field technicians, indicating the specific critical
sensor.
Dry Contacts
A single, small malfunction at a site can lead to waste and/or
damages. The ideal approach is simple:
Head off problems before they occur.
G-Eye solution:
An input dry contact is an electrical circuit that connects to an external
device. The external device can open or close the circuit. The
G-Eye detects a change in the state of the circuit and issues an
alarm message to up to ten user-defined phone numbers. A wide
range of supported sensors, such as security/smoke /flood/motion,
can also be ordered with the unit.
An output dry contact is an electrical circuit that connects to an
external device and can be opened or closed at user command.
This enables the G-Eye user to control external devices; for
example: opening or closing a gate, turning a generator or an air
conditioner off or on.
Power/UPS
1) Vital electrical systems require backup units to supply power in
the event of a mains failure.
2) Wide electrical measurements capacity
G-Eye solution:
1)The unit has a built-in web interface enabling the user to browse
anytime and anywhere using an internal/external IP address.
The internal modem is programmed to immediately send an
alert to prearranged recipients when the UPS is in critical state
(battery low), while servers receive UDP messages and start
count-down before shutdown. Users can also check UPSs
estimated backup time based on active load, via the web, and
monitor other parameters, including: input/output voltage
according to different phases of UPS, dc battery voltage,
frequency, battery temperature.
2) 0-5 Vdc analog inputs for high/low voltages and currents,
external accessories available for different need.
Users are instantly notified if any measurement exceeds userdefined thresholds. Additional inputs accept 4-20 mA, and a
kWh meter.
IT control
Are you instantly informed of server/switch/routers that suddenly
lose ping request? Can you be alerted in real-time if the CPU
load, physical/virtual memory or hard disc space is over-limit in
one of your 40 servers? Today it is possible to remotely connect
to each server and perform a manual shutdown when the site is
operating on UPS batteries. But after the ac failure is resolved,
why wait till morning and wake them manually when someone
somewhere in the world needs these servers overnight?! How
can you even be sure that the ac has been restored at all?
G-Eye solutions:
The unit can controls and monitors IT targets. User can configure
the IP address, server name, MAC address (retrieved
automatically), shutdown countdown length for ac failure/low
battery, and countdown time for "wake up" when regular ac
power is restored. User-defined number of ping checks, CPU
load, physical/virtual memory and hard disk usage limits, as well
as alarm status when one of these limits is exceeded.
GSM control
User controls the unit via simple SMS commands.
Alarm messages can be sent to different targets
depending on the type of alarm. Examples of control
commands: temperature, dryin, dryout, shutdown,
wake, it, power, humidity . Some of them are of
course password protected.
Exclusive
G-Eye Solutions
Backup capability
Need:
To monitor devices in a remote location, and to be
alerted in the event of a power outage in the building,
which has no power backup system.
Solution:
G-Eye enables you to monitor a wide range of devices
and sensors remotely, and has a built-in battery
backup that enables it to notify you immediately via
SMS in the event of any irregularities, even during a
power outage.
Solution:
Move up to the G-Eye same great features as the G4,
but many more analog inputs for power
measurements, more input and output dry contacts,
plus battery backup. After configuring G-Eye for the
desired alarms, simply disconnect your inputs from
the G4, connect them to the G-Eye, and you're ready
to go.
Server room
Smoke detector
SNMP trap
Air condition start operation automatically
GPRS/SMS Control
and Notification
G-Eye
AC Fail
Motion detector
Shutdown
Servers
Wake-up
Servers
AC Recovered
Alarm
DC > 380v
Door open
AC current >200A
Battery cabinet
High temperature
Leak detection
and notification
G-Eye
Added Values:
Support various UPS Manufacturer and all Gamatronic UPS & DC systems.
Monitors up to 32 Network devices (Servers, routers)
Wake up delay (Wake On LAN).
Environment input measurements :
4 temperature sensors,2 humidity inputs,1 flood detector, 1 liquid level (4-20 mA).
2 Frequencies.
2 kWH meter inputs.
4 analog inputs 60 mVdc / 60 Vdc.
12 analog inputs 05 Vdc. External accessories available for stepping down high
voltages and high currents.
Up to 32 environmental sensors via dry contacts.
Up to 16 dry contact controlled devices.
1 internal Quad band cellular modem.
Auto response to events.
Full remote control via Web or mobile phone.
Event group notifications.
Event logs (256).
Remote
User
Site
Auto response
G-eye can automatically respond to events
without human intervention.
Environment
GSM:
Humidity
Temperature
Http:
Flood
Liquid Level (4-20 mA)
Servers
Check CPU load, Memory space and more
Ping check
Automatic Shutdown/wake-up in UPS
failures and immediate shutdown in critical
event
Power measurements
UPS monitoring, Gamatronic DC systems
AC/DC voltage/current
Frequency
kWH meter
SNMP:
Notification:
G-Eye
main
screen
G-Eye
main
screen
UPS P+
G-Eye
IT devices
Thank you !