You are on page 1of 83

International Paint Ltd.

Oil & Gas Solutions

Agenda (2.5 hours)


1. International Paint Product Range
2. Structural Steel
3. Corrosion Under Insulation (CUI)
4. Tank Linings
5. Concrete
6. Pipelines
7. Passive Fire Protection (PFP)
8. Summary
All products supplied and technical advice and recommendations given are subject to our standard conditions of sale.
Any information given here is for guidance only and no representation or warranty is given as to its potential use.

International Paint
The Oil & Gas Partner of Choice
International Paint supply all the major multinationals in the Oil & Gas
Industry.
International Paint are named on the Shell, Exxon, Chevron, Saudi
Aramco, Dow, Vopak global specifications to name but a few.
We work closely with the owners to provide technical support and
ensure our products meet their needs through test work.
Our support ensures that the owners see the true value of using
International Paint products.
On-site we can provide technical consultation on choice of paint for
difficult maintenance jobs as well as Technical Support Representatives
to attend application of the paint and train the applicator.
All products supplied and technical advice and recommendations given are subject to our standard conditions of sale.
Any information given here is for guidance only and no representation or warranty is given as to its potential use.

International Paint
Supplying all your paint needs
High Temperature
Surfaces

Corrosion
Under
Insulation

Tank
Externals

Structural
Steel

Tank
Internals

Concrete

OEM
Fire
Protection

All products supplied and technical advice and recommendations given are subject to our standard conditions of sale.
Any information given here is for guidance only and no representation or warranty is given as to its potential use.

International Paint - Technology Leader


International Paint have various systems which utilise market
leading technology to provide solutions to your most difficult
corrosion issues:
Intertherm 751 CSA unique, patented heat & corrosion resistance
Enviroline High performance, thick film, rapid cure tank linings
Ceilcote Resistant to the most highly aggressive chemical attack
Intercrete Cementitious repair mortars and linings
Chartek 100% volume solids passive fire protection

All products supplied and technical advice and recommendations given are subject to our standard conditions of sale.
Any information given here is for guidance only and no representation or warranty is given as to its potential use.

Structural Steel

All products supplied and technical advice and recommendations given are subject to our standard conditions of sale.
Any information given here is for guidance only and no representation or warranty is given as to its potential use.

Typical Paint Specification for


Un-Insulated External Surfaces <120C

Polyurethane Topcoat 50m


Epoxy Intermediate 100m
Zinc Rich Primer 50m

Steel Substrate

All products supplied and technical advice and recommendations given are subject to our standard conditions of sale.
Any information given here is for guidance only and no representation or warranty is given as to its potential use.

Zinc silicate technology


Rapid overcoating within 4 hours
Available with various zinc levels to fulfil International Standards
requirements

All products supplied and technical advice and recommendations given are subject to our standard conditions of sale.
Any information given here is for guidance only and no representation or warranty is given as to its potential use.

Zinc primers
Often, specifications for zinc primers will be guided by the following
industry standards, which set levels of zinc dust in the dried film:

Standard
SSPC Paint 20
Standard

Zinc Level
Level 1

85%

Level 2

77% <85%

Level 3

65% <77%

NORSOK M501

80%

ISO 12944

80%

ASTM D520 zinc dust should contain >94% zinc metal


All products supplied and technical advice and recommendations given are subject to our standard conditions of sale.
Any information given here is for guidance only and no representation or warranty is given as to its potential use.

Micaceous Iron Oxide - MIO


MIO is a lamella type (flake like) form of iron oxide which is insoluble in
water, organic solvents and alkalis
When incorporated into the coating dry film, its lamella type shape aligns
itself parallel to the substrate providing a barrier of overlapping flakes

Dry Film

This barrier prevents the ingress of water, oxygen and ions and thus
seriously slows down the corrosion of steel

MIO
flakes
Steel Substrate

MIO Flakes
All products supplied and technical advice and recommendations given are subject to our standard conditions of sale.
Any information given here is for guidance only and no representation or warranty is given as to its potential use.

Barrier Pigments MIO - micaceous iron oxide

Pigment

Conventional spherical

STEEL SUBSTRATE

All products supplied and technical advice and recommendations given are subject to our standard conditions of sale.
Any information given here is for guidance only and no representation or warranty is given as to its potential use.

Barrier Pigmentation

Role of a Top / Finish Coat

A high quality finish and vibrant colours are important for any structure
.
The main function of finishes is to resist the damaging effects of the sun
which is normally interpreted in coatings as ultraviolet (UV) resistance
as well corrosion protection.
UV resistance is the ability of a finish coat to maintain its colour and
gloss level over an extended period of time

All products supplied and technical advice and recommendations given are subject to our standard conditions of sale.
Any information given here is for guidance only and no representation or warranty is given as to its potential use.

Durability of Finishes
The Carbon-Carbon (C-C) bonds within
traditional organic coatings are less
resilient than those found in acrylic
polysiloxanes

Polysiloxane coatings are significantly


more resilient to UV (sunlight)
degradation which means much
improved cosmetic properties over time
in service

All products supplied and technical advice and recommendations given are subject to our standard conditions of sale.
Any information given here is for guidance only and no representation or warranty is given as to its potential use.

All products supplied and technical advice and recommendations given are subject to our standard conditions of sale.
Any information given here is for guidance only and no representation or warranty is given as to its potential use.

Colour Stability External Exposure

All products supplied and technical advice and recommendations given are subject to our standard conditions of sale.
Any information given here is for guidance only and no representation or warranty is given as to its potential use.

Air separation unit - Germany


New steelwork required a durable,
corrosion resistant paint system to
protect the steel and keep it looking
good for many years.
A 3 coat zinc based system was
chosen from International Paint.
The Interzinc 22 primer and Intergard
475HS intermediate give long-term
corrosion resistance and the
Interthane 990 topcoat provides a
long-term cosmetically good finish.
All products supplied and technical advice and recommendations given are subject to our standard conditions of sale.
Any information given here is for guidance only and no representation or warranty is given as to its potential use.

Refinery vessel externals


Un-insulated vessel externals
coated with Interseal 670 and
Interthane 990

All products supplied and technical advice and recommendations given are subject to our standard conditions of sale.
Any information given here is for guidance only and no representation or warranty is given as to its potential use.

Maintenance of Tank Externals


In order to reduce the amount of dust
created the previous coating on
these tanks was removed by hydro
blasting.
Surface tolerant Interplus 356 was
used to prime the hydro blasted steel
followed by epoxy intermediate
Interseal 670HS and a top coat of
Interthane 990.
The system was roller applied and
cured at 0C allowing application
during the winter with no additional
heating.
All products supplied and technical advice and recommendations given are subject to our standard conditions of sale.
Any information given here is for guidance only and no representation or warranty is given as to its potential use.

Long lasting finish


Vessels at a gas processing plant in the Netherlands
coated with Interfine 878

All products supplied and technical advice and recommendations given are subject to our standard conditions of sale.
Any information given here is for guidance only and no representation or warranty is given as to its potential use.

2009 Condensate Separator Container


(PEMEX, Mexico)
Interzone 954 was applied
while the condenser was
operating and damp
The product had a hard
drying time of 8 hours
Power Tool Cleaning (SSPC- P3)
Condensate Separator Vessel

There was no problem with


runoff or condensation on
the surface

All products supplied and technical advice and recommendations given are subject to our standard conditions of sale.
Any information given here is for guidance only and no representation or warranty is given as to its potential use.

2009 Condensate Separator Container


(PEMEX, Mexico)
Application of Interzone 954

Application of Interzone 954


on 6 condensate pipe
All products supplied and technical advice and recommendations given are subject to our standard conditions of sale.
Any information given here is for guidance only and no representation or warranty is given as to its potential use.

2007 Ettrick Sage Hot Tap Project


(ExxonMobil, UK)
Hot tap structure (500 ltrs )
- Surface prep: blast Sa2.5 or SSPC-SP6
- Full coat Interzone 954 (450m)

All products supplied and technical advice and recommendations given are subject to our standard conditions of sale.
Any information given here is for guidance only and no representation or warranty is given as to its potential use.

2003 Valves
(PEMEX, Mexico) (cont.)

Manually cleaned and


washed with fresh water
Two coats of Interzone
954 applied with
conventional spray
equipment and a brush
All products supplied and technical advice and recommendations given are subject to our standard conditions of sale.
Any information given here is for guidance only and no representation or warranty is given as to its potential use.

2003 Valves
(PEMEX, Mexico) (cont.)
Application of Interzone 954 grey

Final appearance of
Interzone 954 yellow
All products supplied and technical advice and recommendations given are subject to our standard conditions of sale.
Any information given here is for guidance only and no representation or warranty is given as to its potential use.

High Temperature
Coatings

All products supplied and technical advice and recommendations given are subject to our standard conditions of sale.
Any information given here is for guidance only and no representation or warranty is given as to its potential use.

High Heat
Certain epoxy-phenolic binder systems are suitable for high
temperatures up to the 230C (446F) limit, thereafter,
alternative inorganic binder systems need to be used
Product Name

Resin Type

Maximum
Temperature

Intertherm 715*

Modified Silicone

<100C

Intertherm 228

Epoxy Phenolic

230C

Intertherm 875*

Silicone-acrylic

260C

Titanium Modified
Inorganic Co-Polymer

400C

Silicone

540C

Intertherm 751 CSA


Intertherm 50*

*For some of these materials where improved corrosion


protection is required, the Intertherm products can be
applied directly over zinc rich primers (e.g. Interzinc 22)
All products supplied and technical advice and recommendations given are subject to our standard conditions of sale.
Any information given here is for guidance only and no representation or warranty is given as to its potential use.

Durable finish for chimney stacks


New chimney stack
operating at this refinery
required a high
temperature resistant
finish.
Interzinc 22 was applied to
the grit blasted surface in
the workshop and once
installed on site Intertherm
50, aluminium silicone was
applied.

All products supplied and technical advice and recommendations given are subject to our standard conditions of sale.
Any information given here is for guidance only and no representation or warranty is given as to its potential use.

Corrosion Under
Insulation

All products supplied and technical advice and recommendations given are subject to our standard conditions of sale.
Any information given here is for guidance only and no representation or warranty is given as to its potential use.

Inorganic Zinc Silicate Coatings


Many engineers strictly follow the NACE
RP0198 recommendations, & use IOZ for
all high temperature service above 120C.
BUT NACE do not recommend the use
of Zinc Silicates (or Galvanising) on Carbon
Steel under warm, wet Insulation.

CUI with IOZ Primer

.Inorganic Zinc Coatings or Galvanising shall not be used under


Thermal Insulation in the 50-150C service temperature range for long
term or cyclic service. Zinc provides inadequate resistance in closed,
sometimes wet environments.
All products supplied and technical advice and recommendations given are subject to our standard conditions of sale.
Any information given here is for guidance only and no representation or warranty is given as to its potential use.

Intertherm 50 Cyclic heating to 400C

After heating
to 3x400C

Visually the
coating was in
good condition

Followed by
12 months
C5M

Rust Ri 5
Cracking Density 5;
Size 3-5

All products supplied and technical advice and recommendations given are subject to our standard conditions of sale.
Any information given here is for guidance only and no representation or warranty is given as to its potential use.

Gas Processing Plant, Austria


Gas processing plant in Austria.
The gas driers are filled with
SilicaGel to absorb moisture from
the gas.
Equipment cycles from ambient up
to over 300C in order to drive
moisture out of SilicaGel once it is
saturated.
Previous
zinc
silicate
and
aluminium silicone system had
failed.
All products supplied and technical advice and recommendations given are subject to our standard conditions of sale.
Any information given here is for guidance only and no representation or warranty is given as to its potential use.

31

CUI Coating Selection

All products supplied and technical advice and recommendations given are subject to our standard conditions of sale.
Any information given here is for guidance only and no representation or warranty is given as to its potential use.

Interplus 256 Preventing CUI


Stripper columns were coated with
Interplus 256 (aluminium) whilst in
service.
The surface temperature was 56C
and 3 coats of Interplus 256 were
applied in quick succession to create
a total dry film thickness of 150200m.
After the coating had cured the
insulation was replaced on the
stripper columns

All products supplied and technical advice and recommendations given are subject to our standard conditions of sale.
Any information given here is for guidance only and no representation or warranty is given as to its potential use.

Intertherm 228 Case History


Intertherm 228 was applied to
the outside of this insulated
vessel.
The vessel had been suffering
from Corrosion Under
Insulation (CUI)

All products supplied and technical advice and recommendations given are subject to our standard conditions of sale.
Any information given here is for guidance only and no representation or warranty is given as to its potential use.

Intertherm 751 - Product Properties


Two component
Ambient cure
High build - 1x200m or
2x125m
High temperature corrosion
resistant coating - 400C
Resistant to temperature
cycling
Based on Titanium Modified
Inorganic Copolymer
Technology
Pigmented with Aluminium
Flake

All products supplied and technical advice and recommendations given are subject to our standard conditions of sale.
Any information given here is for guidance only and no representation or warranty is given as to its potential use.

Temperature Cycle Ambient to 300C


Preparation - Garnet Blast Sa2
Roller Application 2 Coats
No Insulation
Aluminium Jacket with Perforations for
Protection

All products supplied and technical advice and recommendations given are subject to our standard conditions of sale.
Any information given here is for guidance only and no representation or warranty is given as to its potential use.

Cyclic Pipeline in C5M


Environment
Photographs from 1st
inspection after 11 months.
Inspected again after 28
months and was still in
good condition.

Following
successful
trial
customer
has
specified
Intertherm 751 CSA for all
vessels and pipeline under
insulation

All products supplied and technical advice and recommendations given are subject to our standard conditions of sale.
Any information given here is for guidance only and no representation or warranty is given as to its potential use.

Propane Treater Unit - Australia

Temperature C

260

80
40
Time

All products supplied and technical advice and recommendations given are subject to our standard conditions of sale.
Any information given here is for guidance only and no representation or warranty is given as to its potential use.

Propane Treater Unit, Australia

Application October 2005.


Grit blast 2.5.
Airless Spray Applied.
1x200m.
Total Area 200m.

All products supplied and technical advice and recommendations given are subject to our standard conditions of sale.
Any information given here is for guidance only and no representation or warranty is given as to its potential use.

Propane Treater Unit, Australia

Photographs during inspection


after one year in service. Also
passed second inspection in
October 2007.

All products supplied and technical advice and recommendations given are subject to our standard conditions of sale.
Any information given here is for guidance only and no representation or warranty is given as to its potential use.

Propane Treater Unit, Australia


Further inspections have
shown 7 years service with no
signs of degradation

2008

All products supplied and technical advice and recommendations given are subject to our standard conditions of sale.
Any information given here is for guidance only and no representation or warranty is given as to its potential use.

2011

Linings

All products supplied and technical advice and recommendations given are subject to our standard conditions of sale.
Any information given here is for guidance only and no representation or warranty is given as to its potential use.

International Paint Linings Offer


International Paint have the largest linings range in the market
International paint linings can be use to protect the storage tanks,
process vessels, equipment, pipe lines and secondary containment
areas.
International Paint linings can protect both steel and concrete
substrates from attack by a wide range of aggressive chemicals.
The International Paint Linings Offer includes epoxy, epoxy phenolic,
epoxy novolac, vinyl ester, novolac vinyl ester, polyurethane and
polyurea/polyurethane hybrid technology.

All products supplied and technical advice and recommendations given are subject to our standard conditions of sale.
Any information given here is for guidance only and no representation or warranty is given as to its potential use.

44

Interline
Interline is International Paints core linings offer
In the market since 1970s
Mostly epoxy based linings for general internal tank lining use
Widely specified by Oil & Gas Majors and global chemical producers
Range has numerous owner approvals and long track record of
success.
Normally used to protect steel storage tanks

All products supplied and technical advice and recommendations given are subject to our standard conditions of sale.
Any information given here is for guidance only and no representation or warranty is given as to its potential use.

45

Interline Product Highlights


Interline 850
Cost effective, new construction epoxy tank lining. Thin film to offer the
lowest cost per square meter in terms of material cost.
Interline 984
Multi-purpose epoxy phenolic tank lining. Resistant up to 90C in
constant immersion. Suitable for immersion in hydrocarbons including
biofuels. One of the few tank linings approved to EI 1541 making it
suitable for EI/JIG Standard 1530 compliant jet fuel storage systems
Interline 984 Matcote
Chopped strand reinforced lining system applied by automatic chopper
gun and spray equipment. Applies reinforced lining system at faster
rates than conventional hand lay systems.
All products supplied and technical advice and recommendations given are subject to our standard conditions of sale.
Any information given here is for guidance only and no representation or warranty is given as to its potential use.

46

Interline Examples

Diesel storage tank in South Africa.


Lined with Interline 984

Jet Fuel Tank in Turkey.


Lined with Interline 850

Brine tank in Malaysia.


Internally lined with Interline 399
All products supplied and technical advice and recommendations given are subject to our standard conditions of sale.
Any information given here is for guidance only and no representation or warranty is given as to its potential use.

47

Ceilcote
Ceilcote Company founded in 1926
Acquired by International Paint in 2006
Specialists in vinyl ester and novolac vinyl ester resins which can resist
the most aggressive chemical environments
Leaders in the protection of Flue Gas De-Sulphurisation plants
Usually used to protect steel and concrete chemical storage tanks and
secondary containment areas.

All products supplied and technical advice and recommendations given are subject to our standard conditions of sale.
Any information given here is for guidance only and no representation or warranty is given as to its potential use.

48

Ceilcote Product Highlights


Ceilcote Mat Screed Systems
Highly reinforced systems to give high strength and chemical
resistance. These hand applied systems give long term chemical
resistance, ideal for concrete tanks and secondary containment areas.
Ceilcote CeilLine Systems
The flexible base layer in the CeilLine systems give crack bridging
properties which means that if the concrete moves and cracks after
application of the system the topcoat will remain intact and not crack.
Ceilcote 282HB
Widely specified in Flue Gas De-Sulphurisation equipment Ceilcote
282 has excellent high temperature resistance and this high build
version can be applied to the correct thickness in 2 coats instead of 3.
All products supplied and technical advice and recommendations given are subject to our standard conditions of sale.
Any information given here is for guidance only and no representation or warranty is given as to its potential use.

49

Ceilcote Examples

Crystallisers in Jordan.
Internally lined with Ceilcote 180

Secondary Containment Area in Turkey.


Lined with Ceilcote 232 Mat Screed

Flue Gas De-Sulphurisation Unit in Austria


Lined with Ceilcote 282
All products supplied and technical advice and recommendations given are subject to our standard conditions of sale.
Any information given here is for guidance only and no representation or warranty is given as to its potential use.

50

Enviroline
Enviroline Company founded in 1960
Acquired by International Paint in 2008
Specialists in high temperature resistant epoxy novolac linings
Enviroline products offer cost reduction to the asset owner due to quick
return to service times and winter cure grades
Specified by many Oil & Gas Majors
Usually used to protect steel storage tanks and process vessels

All products supplied and technical advice and recommendations given are subject to our standard conditions of sale.
Any information given here is for guidance only and no representation or warranty is given as to its potential use.

51

Enviroline Product Highlights


Enviroline 376F-60
Flake and fibre reinforced spray applied in one thick coat of 1500m.
Does not required any other layers or rollering as traditional reinforced
system do.
Full cure in 14 hours at 25C
Enviroline 376F LT Series
Low Temperature cure grade. Cures down to -7C. Cure in 3 days at
0C. Traditional epoxy linings do not cure below 5C and are not
recommended to cure below 10C.
Enviroline 405HT
High temperature immersion resistant thick film lining. Can resist up to
120C in constant immersion. Applied in one thick coat of 500m. Full
cure in 14 hours at 25C.
All products supplied and technical advice and recommendations given are subject to our standard conditions of sale.
Any information given here is for guidance only and no representation or warranty is given as to its potential use.

52

Enviroline Examples

High temperature process vessel in Italy.


Internally lined with Enviroline 405HT

Buried pipeline in USA.


Externally lined with Enviroline 376F-30

Buried Fuel Tank in USA.


Lined with Enviroline
All products supplied and technical advice and recommendations given are subject to our standard conditions of sale.
Any information given here is for guidance only and no representation or warranty is given as to its potential use.

53

Storage Tank Base


Chemical storage tank in the UK
required sealing of the gap between tank
and tank base.
Intercrete products are used with an
elastic reinforcement tape to seal the
gap between the tank and the tank base.
The Intercrete system is has good
adhesion to both concrete and steel to
prevent water entering
The Intercrete system also has good
flexibility to allow for differential
movement of steel and concrete
All products supplied and technical advice and recommendations given are subject to our standard conditions of sale.
Any information given here is for guidance only and no representation or warranty is given as to its potential use.

Tank Base Sealing


Gap between concrete
base and steel tank was
sealed with an Intercrete
system and top coated with
Interfine 691.
The system creates a
flexible waterproof seal
which will allow for the
different movement of the
steel and concrete

All products supplied and technical advice and recommendations given are subject to our standard conditions of sale.
Any information given here is for guidance only and no representation or warranty is given as to its potential use.

Concrete

All products supplied and technical advice and recommendations given are subject to our standard conditions of sale.
Any information given here is for guidance only and no representation or warranty is given as to its potential use.

International Paint supply the full range of products and lining to repair
and protect concrete containment areas in the Oil & Gas Industry.
The cementitious rebuilding products can be used to repair damaged
and degraded concrete.
The linings can be used in areas of continuous immersion, such as
storage tanks and also in areas of splash and spill such as secondary
containment areas.

All products supplied and technical advice and recommendations given are subject to our standard conditions of sale.
Any information given here is for guidance only and no representation or warranty is given as to its potential use.

Intercrete

All products supplied and technical advice and recommendations given are subject to our standard conditions of sale.
Any information given here is for guidance only and no representation or warranty is given as to its potential use.

Intercrete
Intercrete was launched in 2012
Intercrete are cementitious, water based products
Intercrete products are designed to repair and protect concrete
Intercrete offers an excellent barrier to water along with high
compressive strength and adhesion.
No primer required. The products are applied to concrete which is wet
with clean water meaning that you do not need to wait for the concrete
to dry before applying Intercrete.
Usually used to repair and protect concrete tanks
All products supplied and technical advice and recommendations given are subject to our standard conditions of sale.
Any information given here is for guidance only and no representation or warranty is given as to its potential use.

59

Intercrete 4801
High build structural repair
mortar.
80mm in one application to
overhead and vertical repairs.
Can be bulked out with stones
for deeper holes.
No primer required.
Applied to a water saturated
substrate.
Demonstration Video
All products supplied and technical advice and recommendations given are subject to our standard conditions of sale.
Any information given here is for guidance only and no representation or warranty is given as to its potential use.

Intercrete 4820
Waterproof protective render, pore filler &
fairing coat.
Withstand water pressure up to 10 bar.
Maximum thickness 6mm. Can be featheredged to 0mm.
Used to fill blow holes etc.
Applied by trowel can be bagged rubbed.
Demonstration Video
All products supplied and technical advice and recommendations given are subject to our standard conditions of sale.
Any information given here is for guidance only and no representation or warranty is given as to its potential use.

Intercrete 4840
Cementitious coating

Waterproofing cementitious coating


Resists 10 bar water pressure (positive and negative)
2mm is equivalent to 100mm concrete cover
Flexible withstand thermal expansion and contraction
Spray applied for large areas
Can be applied to damp and green concrete
25 years track record

All products supplied and technical advice and recommendations given are subject to our standard conditions of sale.
Any information given here is for guidance only and no representation or warranty is given as to its potential use.

Secondary Containment area


protection
The concrete floor area around
tanks containing 31%
hydrochloric acid and 33%
Sodium hydroxide was protected
with Ceilcote 380 primer and
Ceilcote 232 novolac vinyl ester
chemically resistant lining.

All products supplied and technical advice and recommendations given are subject to our standard conditions of sale.
Any information given here is for guidance only and no representation or warranty is given as to its potential use.

Drain Channel Sump


Oman
This sump in the Mechanical Vapour Compression (MVC)
Plant was suffering from attack by oily water from drain
channels at a temperature of less than 100C
The damaged concrete was
primed with Ceilcote 380
concrete primer, rebuilt with
paste made of Ceilcote 380
mixed with powder and then
coated with Ceilcote 222HT to
provide long-term chemical
resistance.

All products supplied and technical advice and recommendations given are subject to our standard conditions of sale.
Any information given here is for guidance only and no representation or warranty is given as to its potential use.

New Construction Power Station


Flue Gas De-sulphurisation unit
at a new build power station in
Saudi Arabia.
Ceilcote 242MR was selected to
protect the absorber against the
high temperature chemical
attack.

All products supplied and technical advice and recommendations given are subject to our standard conditions of sale.
Any information given here is for guidance only and no representation or warranty is given as to its potential use.

Ceilcote 2000MR
Secondary Containment Area around this sulphuric acid
tank was rebuilt and protected with Ceilcote 2000MR

All products supplied and technical advice and recommendations given are subject to our standard conditions of sale.
Any information given here is for guidance only and no representation or warranty is given as to its potential use.

Ceilcrete

6
7
All products supplied and technical advice and recommendations given are subject to our standard conditions of sale.
Any information given here is for guidance only and no representation or warranty is given as to its potential use.

Chemical and effluent treatment


- Secondary containment

Protection of chemical
handling area

All products supplied and technical advice and recommendations given are subject to our standard conditions of sale.
Any information given here is for guidance only and no representation or warranty is given as to its potential use.

Ceilcote 2000 CeilLine

All products supplied and technical advice and recommendations given are subject to our standard conditions of sale.
Any information given here is for guidance only and no representation or warranty is given as to its potential use.

Transformer Bunds
The client wanted to quickly seal
electric transformer bunds to ensure
that no leaking was possible and to
prevent environmental damage.
One thick coat of Polibrid 705E was
applied to the bund and hydro tested
the same day
The flexibility of Polibrid allows it to
move with the concrete substrate and
not crack.

All products supplied and technical advice and recommendations given are subject to our standard conditions of sale.
Any information given here is for guidance only and no representation or warranty is given as to its potential use.

Pipelines

All products supplied and technical advice and recommendations given are subject to our standard conditions of sale.
Any information given here is for guidance only and no representation or warranty is given as to its potential use.

Internal Coatings
Standard

Descript Cargo Approved


ion
Products
UK DEF
Jet Fuel
Jet Fuel Interline 850
STAN 80-97
Interline 399
Interline 984
MIL-CJet Fuel
Jet Fuel Interline 850
4556E
EI 1541
Jet Fuel
Jet Fuel Interline 984
API RP5L2 Epoxy
Gas
Intergard 272
Flowcoat
Intergard 2272
s
ISO 15741 Epoxy
Gas
Intergard 272
Flowcoat
Intergard 2272
s
NSF
Potable
Potable Interline 850
Water
Water
Interline 925
Approval
Interline 975
All products supplied and technical advice and recommendations given are subject to our standard conditions of sale.
Any information given here is for guidance only and no representation or warranty is given as to its potential use.

Suitable
Products

Interzone 485 Workshop application

Interzone 485 - Ultra high


build epoxy applied to the
externals of buried pipeline in
workshop.
Coating passes BS EN 10289 showing suitability for use in this
environment.
All products supplied and technical advice and recommendations given are subject to our standard conditions of sale.
Any information given here is for guidance only and no representation or warranty is given as to its potential use.

Application Example
Buried Pipeline

Interzone 485 - Ultra high build epoxy applied to the externals of buried
pipeline in the field.
Coating tested to BS EN 10289 showing suitability for use in this
environment
All products supplied and technical advice and recommendations given are subject to our standard conditions of sale.
Any information given here is for guidance only and no representation or warranty is given as to its potential use.

Application Example
Buried Pipeline
Externals of this buried natural gas pipeline required re-coating. The
contractor recommended Enviroline 376F-30 cured epoxy novolac lining
following 3 years successful experience using the product.
The quick cure of the coating allows quick back filling of the pipe and also
reduces the good weather window required to apply the coating. This saved
the customer money and allowed quick completion of the job.

All products supplied and technical advice and recommendations given are subject to our standard conditions of sale.
Any information given here is for guidance only and no representation or warranty is given as to its potential use.

External Coatings
Standa
rd
ISO
10290
ISO
10289
ISO
21809
ISO
12944

Descripti
on
Polyuretha
ne
External
Coatings
Epoxy
external
coatings

Environme Approved
nt
Products
Buried
Interzone
1800 (under
test)

Suitable
products

Buried

Enviroline 376 F
Enviroline 405HT
Interzone 954

Interzone
485
Interzone
1500

Field Joints Buried


External
coatings

Above
ground

Enviroline 124
Interzone 485
Interzinc 22 /
52
Intergard

All products supplied and technical advice and recommendations given are subject to our standard conditions of sale.
Any information given here is for guidance only and no representation or warranty is given as to its potential use.

Interline 925
Interline 925 was used to internally line 26,000 m of water pipeline
in India.
Interline 925 was spray applied using rotating airless spray
equipment.

All products supplied and technical advice and recommendations given are subject to our standard conditions of sale.
Any information given here is for guidance only and no representation or warranty is given as to its potential use.

Case Histories- Oil & Gas Onshore


Oman Gas Corporation- Pipeline
Owner: Oman Gas Corporation
Applicator: Jindal Saw Ltd
Location: Gujarat
Project Finished: 2007
Coating: Epoxy Flowcoat
Area: 300,000m2

All products supplied and technical advice and recommendations given are subject to our standard conditions of sale.
Any information given here is for guidance only and no representation or warranty is given as to its potential use.

CHARTEK 1709
FIREPROOFING

A real alternative to cement or concrete based fire protection

All products supplied and technical advice and recommendations given are subject to our standard conditions of sale.
Any information given here is for guidance only and no representation or warranty is given as to its potential use.

Chartek 1709
Chartek 1709 is epoxy intumescent
fireproofing
It gives protection against oil & gas
fires for the onshore hydrocarbon
industries
In a fire it forms an insulating layer to
protect the steel from extreme heat

All products supplied and technical advice and recommendations given are subject to our standard conditions of sale.
Any information given here is for guidance only and no representation or warranty is given as to its potential use.

C1709 gives corrosion protection


Strong, durable material
30 years track record of corrosion
protection
Epoxy market leader used by all major
operators worldwide
No recorded failure due to the material
itself
Fast application: no pins and no metal
mesh

All products supplied and technical advice and recommendations given are subject to our standard conditions of sale.
Any information given here is for guidance only and no representation or warranty is given as to its potential use.

A real alternative to cementitious


fireproofing
Concrete/cement fireproofing is porous
Allows corrosion to take place unseen
(Corrosion Under Fireproofing)
Requires regular crack repair and
maintenance of topcoat
High cost of maintenance gives high
lifecycle costs

After fire
buckling of
steel column
protected by
cementitous
pfp

Corrosion of
column web
under
cementitious PFP

All products supplied and technical advice and recommendations given are subject to our standard conditions of sale.
Any information given here is for guidance only and no representation or warranty is given as to its potential use.

Collapsed sphere due to corrosion


under cementitious PFP

Summary
International Paint have the complete product offer for the Oil & Gas
Industry
International Paint have full range of traditional paint systems to protect
structural steel and offer long-term performance.
Specialised products can be used to solve most difficult issues on site.
International Paint provide high levels of service to both owners and
applicators whilst adhering to strict business principles practices from
Akzo Nobel.

All products supplied and technical advice and recommendations given are subject to our standard conditions of sale.
Any information given here is for guidance only and no representation or warranty is given as to its potential use.

You might also like