You are on page 1of 28

1.

Production Capacity

HYUNDAI

1) Annual Production Capacity

: 28,000MVA

2) Maximum Capacity

: up to 800MVA(3 phase)

3) Maximum Voltage

: up to 765kV, 2050 BIL

4) Factory Space

: 16,800m

5) Manpower for Transformer factory


- 55 Engineers
- 340 Skilled Workers

2. Production Range

HYUNDAI

1) Power Transformer
2) Distribution Transformer
3) Cast resin Transformer
4) Special Purpose Transformer

Rectifier Transformer

Furnace Transformer

Dry type Transformer

Shunt Reactor

Mobile Transformer

3. Quality Assurance (ISO 9001)

HYUNDAI

1) Original Date of Issue : July of 1989


2) Registered Parts of Quality Assurance

Transformer Design and Development

Production and Testing

Installation and Service

4. Applicable Standard

HYUNDAI

1) IEC 76

(For Europe and Asia)

2) ANSI C57.12.00

(For America)

3) CAN/CSA-C88-M90

(For Canada)

4) AS 2374

(For Australia)

5) ES 140

(For Korea)

5. Short Circuit Test

HYUNDAI

1) Major Performance Record of Short Circuit Test


No.

Specification of Transformer

Test Date

Test of
Tap Change

Customer

Generating Transformer
3PH 6/64/85/106/119MVA 230/14.8kV YNd1

Sept. 1995

N.L.T.C

PUD in USA

Power Transformer
3PH 45/60MVA 154/23kV Ynyno(d)

Nov. 1989

O.L.T.C

KEPCO in Korea

Power Transformer
3PH 35/44MVA 154/23kV YNd1

Nov. 1986

O.L.T.C

In-Chon Iron &


Steel in Korea

Distribution Transformer
3PH 10MVA 22/6.6kV Ynynod(d)

Dec. 1986

O.L.T.C

PUB in Singapore

Power Transformer
3PH 20/26MVA 132/11.5kV Dyn11

Dec. 1986

O.L.T.C

WAPDA in Parkistan

5. Short Circuit Test

HYUNDAI

2) Detailed Explanation for the Short Circuit Test Performed to the


230kV Transformers for Rocky Reach Project

Customer : Public Utility District No.1 of Chelan County in U.S.A

Project

Transformer Rating

: Replacement for Rocky Reach Dam Transformer

3phase 60Hz 119MVA 14.8/230kV Step-up Transformer

Basic Impulse Level on H.V Side : 900kV

Standard : ANSI C57.12.00

Tested and Certified by Korea Electrotechnology Research Institute

Picture of Short Circuit Test


HYUNDAI

6. Development of Transformer

HYUNDAI

1) 765kV Transformer

1PH 60Hz 2 x 333.3MVA 765/345kV


OLTC type Auto transformer (Bil : 2050kV)

: 1998 Developed

1PH 60Hz 204MVA 20.9/765kV


NLTC type Step-up transformer (Bil : 2050kV) : 1999 Developed

1PH 60Hz 370MVA 765/345/23kV


NLTC type Auto transformer (Bil : 2050kV)

: 1999 Developed

2) Gas Insulated Transformer

1PH 60Hz 20MVA 154/23kV OLTC Type Transformer


(Under Development)

6. Development of Transformer

HYUNDAI

3) Mobile Transformer (Developed)

3PH 60Hz 40MVA 154/23kV (1996)

"H" Class insulation (95C temp. rise)

Comparison of "A" and "H" class insulation


Insulation

No Load Loss

Load Loss

Weight

A Class

31 kW

241 kW

35 TON

H class

23 kW

434kW

25 TON

Remark

74%

180%

71%

Transportation

with trailer

Weight : 39.4 Ton

Size(m) : L8.6 x W2.9 x H3.9

10

Picture of 154kV 40MVA Mobile Transformer-Using H Class


Insulation (NOMAX Paper)

HYUNDAI

11

7. Major International Clients and Performances

HYUNDAI

1) North America
Country

U.S.A

Client
Alumnium Company of America
Los Angeles Department of Water and Power
Chelan Country
Black & Veatch
General Electric Company
Baltimore Gas & Electric
CRS Sirrine Engineers
Zurn Nepco
Westinghouse
Florida Power Corporation
Colorado River Commission of Nevada
Sacramento Municipal Utility District
Duke Fluor Daniel
Babcock & Wilcox Engineering
Lower Colorado River Authority
Puget Sound Energy
National Electrical System Inc.
City of Tacoma
New York Power Authority

Rating of Transformer
161/13.8kV, 93MVA
34.5/5.04kV, 16MVA
230/14.8kV, 119MVA
230/15.75kV, 315MVA
138/13.8kV, 125MVA
13.8/2 X 3.9kV, 20MVA
69/13.8KkV, 90MVA
132/11.5kV, 90MVA
138/13.8kV, 150MVA
16/230kV, 235MVA
230/69kV, 200MVA
230/69/13.8kV, 200MVA
115/11kV, 93MVA
138/15.5kV, 160MVA
138/22.8kV, 490MVA
230/117.8kV, 325MVA
115/13.2kV, 115MVA
115/13.8kV, 56MVA
230/13.2kV, 86MVA

12

7. Major International Clients and Performances

HYUNDAI

2) South America
Country

Client
Interconexion Electrical S.A

Colombia

Rating of Transformer
230/34.5kV, 50MVA
500/230/34.5kV, 150MVA

EPM

230/115/46kV, 90MVA

ESSA

115/34.5/13.8kV, 40MVA

Trinidad
& Tobago

Trinidad & Tobogo Electricity Commission (TTEC)

33/12kV, 6MVA

Panama

CELMEC

115/13.8kV, 50MVA

Chile

Chilectra

230/110/13.2kV, 130MVA

Peru

Proyecto Ampliacion de LA S. E.

220/60/10kV, 50MVA

Guatemala

JBV Guatemala, LCC

230/13.8kV, 150MVA

Venezuela

ENELVEN

200/115/13.8kV, 200MVA

Puerto Rico
Brazil

Abengoa
CERJ

115/2 X 13.8kV, 300MVA


138/13.8kV, 33.3MVA

13

7. Major International Clients and Performances

HYUNDAI

3) Asia
Country

Client

Rating of Transformer

Japan

Tokyo Electric Power Company

66/6.9kV, 20MVA

Singapore

Public Utilities Board (PUB)

22/6.6kV, 10MVA

Tenaga Nasional Bhd. (TNB)

275/132kV, 240MVA

Sarawak Electricity Supply Corp. (SESCO)

275/230kV, 250MVA

Sabah Electricity Board (SEB)

275/132kV, 180MVA

Perusahaan Umum Listrik Negara (PLN)

150/20kV, 100MVA

National Power Corp (NPC)

230/115/13.8kV, 300MVA

Manila Electric Company (MERALCO)

110/34.5/13.8kV, 83.3MVA

Electricity of Vietnam (EVN)

230/121/22kV, 63MVA

Vietnam POSCO Steel Co.

110/6.6kV, 20MVA

Bangladesh Power Development Board (BPDB)

240/140kV, 150MVA

Malaysia

Indonesia
Philippines
Vietnam

Bangladesh

14

7. Major International Clients and Performances

HYUNDAI

3) Asia
Country

Thailand

Myanmar

Parkistan

India

Client

Rating of Transformer

Electricity Generating Authority of Thailand (EGAT)

115/34.5/11kV, 50MVA

Metropolitan Electricity Authority (MEA)

60/11.5kV, 60MVA

Provincial Electricity Authority (PEA)

115/23.1kV, 40MVA

Myanmar Electric Power Enterprise (MEPE)

132/33/11kV, 30MVA

Water and Power Development Authority (WAPDA)

230/11kV, 125MVA

Karachi Electricity Supply Corporation (KESC)

132/11kV, 40MVA

D. G Khan Cement Company

132/6.3kV, 20/26MVA

Oil and Natural Gas Commission (ONGC)

6.6/0.433kV
2000KVA (Cast Resin Type)

Srilanka

Ceylon Electricity Board (CEB)

132/33kV, 31.5MVA

15

7. Major International Clients and Performances

HYUNDAI

4) Middle East
Country

Client

Rating of Transformer

Electricity Corporation

132/33kV, 60MVA

SCECO-Central

132/13.8kV, 100MVA

SCECO-East

230/115/34.5kV, 400MVA

Tabouk Electricity Company

132/13.8kV, 100MVA

Arabian American Oil Company

66/13.8kV, 67MVA

Iraq

State Organization of Electricity (SOE)

400/138.6/11kV, 250MVA

Yemen

Yemen General Electricity Corp. (YGEC)

132/33kV, 25MVA

Lebanon

Council for Development & Reconstruction

66/20-11kV, 40MVA

Dubai Electricity Company

33/11kV, 15MVA

Water and Electricity Department

11/0.433kV, 1500KVA
(Cast Resin Type)

Oman

Ministry of Electricity and Water

33/11kV, 20MVA

Turkey

Turkiye Electric Kurumu

Shunt Reactor
154kV, 5MVAR

Saudi Arabia

U.A.E

16

7. Major International Clients and Performances

HYUNDAI

5) Oceania and Canada


Country
Australia

New Zealand
Papua New
Guniea

Canada

Client

Rating of Transformer

Power Link (Queensland Electricity Commission)


BHP Engineering Pty Ltd.
Shortland County Council
New Zealand Aluminium Smelter Ltd. (NZAS)
The Electricity Commission of P.N.G

132/11kV, 20MVA
132/69/11kV, 20MVA
230/34.5kV, 80/120MVA
132/66/11kV, 120MVA
66/13.8kV, 67MVA
220/11kV, 50MVA
132/66kV, 20MVA

British Columbia Hydro & Power Authority


Richmond Hill Hydro
Manitoba Hydro
Alberta Power Ltd.
Howe Sound Pulp & Paper Ltd.
Yukon Electrical Company
Stone & Webster Canada Ltd.
Transalta Vtilities
Agra Monenco/ Aurora Mine
Saskatchewan Power Corporation

512.5/242/25.2kV, 500MVA
212.5/2 X 28kV, 125MVA
114.3/2 X 12.47kV, 50MVA
144/25kV, 50MVA
230/13.8kV, 62MVA
138/13.8kV, 40MVA
243/2 X 13.8kV, 171MVA
260/72kV, 224MVA
260/72kV, 116.2MVA
128/24.9kV, 29.8MVA

Pacific Power (The Electricity Commission of


New Sourth Wales)

17

7. Major International Clients and Performances

HYUNDAI

6) Europe
Country

Client

Rating of Transformer

Switzerland

ABB Power Generation Ltd.

220/21kV, 420MVA

Germany

Siemens AG

132/6.9kV, 40/45MVA

Denmark

Johs Gran-Hassen Product Ltd.

220/60/10kV, 40/50MVA

7) Africa
Country

Client

Rating of Transformer

Egyptian Electricity Authority (EEA)

21/220kV, 395MVA

Arco Steel

220/22.5kV, 80MVA

Ethiopia

Ethiopian Electric Light and Power Authority (ELPA)

132/15kV, 22MVA

Libya

Heavy Industries Secretariat Tripoil Socialist


Peoples Libyan Arab Jamshebreya

11/225kV, 105MVA

Egypt

18

8. Major Production Facilities

HYUNDAI

1) Over-Head Crane (300 TON x Span 38m)


2) Vacuum Vaporization Facility (L 13m x W 4.8m x H 6.6m)
3) Air - Cleaning Facility (L 45m x W 40m x H 7m)
4) Oil Filtering Machine (8,00 litter / hour)
5) Motorized Transporter for Test (400 TON x 2EA)
6) Core Binding Machine (40 TON x W 8m)
7) Core Lamination Table (120TON)

19

9. Major Testing Facilities

HYUNDAI

1) Impulse Generator System ( 400KV / 600KJ )


2) Oscillation Lightning Impulse Test System (1,800KV / 90KJ )
3) AC Series Resonant Voltage Test System
(1,200KV / 4,800KVA )
4) AC Power Generator System ( 23MVA x 2sets )
5) AC Power Generator System ( 23MVA x 2sets )
6) Condenser Bank ( 158KV, 225MVAR )
7) Transformer Loss Measuring System (200KV / 4,000A )

20

10. Major Manufacturing Process

HYUNDAI

1) Winding Works

21

10. Major Manufacturing Process

HYUNDAI

2) Core lamination

22

10. Major Manufacturing Process

HYUNDAI

3) View of Core Structure (After Completion of Core Lamination)

23

10. Major Manufacturing Process

HYUNDAI

4) Coil Insertion Works

24

10. Major Manufacturing Process

HYUNDAI

5) View of Core and Coil Assembly Works

25

10. Major Manufacturing Process

HYUNDAI

6) Drying Works in Vacuum Vaporization Facility

26

10. Major Manufacturing Process

HYUNDAI

7) Completion of Core & Coil Assembly

27

10. Major Manufacturing Process

HYUNDAI

8) Factory Test

28