You are on page 1of 44

Raisecom MSAP

OPCOM3500E

How did you connect PDH to


SDH before OPCOM3500E?

Trouble in coax cable connection?

What are we facing?


Waste cost of cables, connectors, and DDF
Waste cost of rack space
Not easy to check and manufacture so many cables
Not easy to manage PDH multiplexer from SDH ring
PDH and SDH managements are in deferent NMS software
Ethernet access on MSTP can not reach remote branch on customers site
There is no Ethernet fiber optical ports on my SDH equipments
How can we aggregate Ethernet traffic by VLAN without Ethernet Switch in
SDH ring
Non-protection in current PDH fiber links

OPCOM3500E in C.O.

Multi-Service Access Platform


Overview
OPCOM3500E SDH multi-service access platform is
aggregation equipment, which is designed for traditional
TDM service and broad band IP data service of MAN.
It can meet carrier and customers requirement of
different class bandwidth and multi-service access.

Typical Application

OPCOM3500E Slot Distributing

Slot 0:
Network
Management

Slot 1~5,8~12:

Slot 6,7:

Slot 9:

Power

Tributary

Aggregation

Tributary or GE
Aggregation

Supply

Features
Aggregate all kinds of Raisecom TDM and Ethernet CPE to SDH
Total 4 STM-1 ports or 2 STM-4 ports aggregation unit
No-block cross connection of 1616 VC4 or 10081008 VC12
VC12 cross connection between all tributary units and aggregation units

15 slots, including 2 slots of power supply, 1 slot of management, 2 slots for


aggregation units, 10 slots for tributary units
2Mbit /2MHz clock input & output
Service non-stop when NMS card fail or be taken off

OPCOM3500E Basic System


OPCOM3500E adopts rack design, including chassis, fans board, plug board and
power supply board. For the plug board, including following parts:

Chassis

OPCOM3500E-12DC/D
MSAP chassis

Network management board OPCOM3500E-NMS


SNMP management system
Aggregation board

OPCOM3500E-STM1-M
1 uplink STM-1 optical interfaces
Aggregation board
OPCOM3500E-STM4-M
2 uplink STM-4 optical interfaces
Aggregation board
OPCOM3500E-SUB-ESW-2GE
2 Gigabit Ethernet combo interfaces
Aggregate all tributary boards FastEthernet uplinks

OPCOM3500E-NMS
Network management module of OPCOM3500E Platform

SNMP network
management
port

1) It communicates with network management


software of upper layer and accepts management

Console
port

of upper layer.
2) It can manage OPCOM3500E equipment, and

RS232
Users
channel

corresponding remote equipment.


2M
clock
input

3) Provide clock for whole OPCOM3500E system.


4) Support on-line upgrade of system and tributary

2M
clock
output

board.

OPCOM3500E-STM1-M

Aggregate unit of OPCOM3500E system


Dual STM-1 optical interfaces, with options of either two individual
path or 1+1 path protection
cross module of 16x16 VC4 / 48x48 VC3 / 1008x1008 VC12
Software on-line up-grade of local and remote equipment
Auto Laser Shut down (ALS)

OPCOM3500E Tributary board


OPCOM3500E-SMT1-S SDH STM-1 tributary
2 STM1 optical ports to provide 1+1 link to SDH CPE terminal multiplexer

OPCOM3500E-16E1(-BL) E1 tributary
16 E1 electrical ports 75ohm or 120ohm
OPCOM3500E-30*8 PDH fiber tributary
8 E1 optical ports to connect remote E1(or V.35) fiber modems
OPCOM3500E-120*4, OPCOM3500E-120H*4 PDH fiber tributary
4 PDH fiber optical ports, each port includes 4 E1 traffics, to connect remote PDH
4E1 CPE.
OPCOM3500E-240*2 PDH fiber tributary
2 PDH fiber optical ports, each port includes 8 E1 traffics, to connect remote PDH
8E1 CPE.
OPCOM3500E-120EOS*4 PDH fiber tributary
4 RCMS PDH fiber optical ports, each port includes 4 E1 and 100Mbps FastEthernet traffics, to connect remote RCMS2811 PDH CPE. The Ethernet data could
be mapped to VC12 though EoS function.
OPCOM3500E-120FE*4-GE PDH fiber tributary
4 RCMS PDH fiber optical ports, each port includes 4 E1 and 100Mbps FastEthernet traffics, to connect remote RCMS2811 PDH CPE. The Ethernet data could
be aggregated to a GE port on front panel.

OPCOM3500E Tributary board


OPCOM3500E-P240EOS PDH fiber tributary
2 RCMS PDH fiber optical ports in 1+1 protection, includes 8 E1 and 100Mbps
Fast-Ethernet traffics, to connect remote RCMS2811 PDH CPE. The Ethernet data
could be mapped to VC12 though EoS function.
OPCOM3500E-P240FE PDH fiber tributary
2 RCMS PDH fiber optical ports in 1+1 protection, includes 8 E1 and 100Mbps
Fast-Ethernet traffics, to connect remote RCMS2811 PDH CPE. The Ethernet port
on front panel is used for connection with customers Ethernet Switch.

OPCOM3500E Tributary board


OPCOM3500E-EOS-8FX, OPCOM3500E-EOS-8FE, OPCOM3500E-4FE,
OPCOM3500E-EOS-4FX, Ethernet over SDH tributary
8 or 4 Ethernet ports, optional optical and electrical, EoS board, without VLAN Tag
configuration
OPCOM3500E-EOSE-8FX Ethernet over SDH tributary
8 100Base-Fx optical ports, EoS board, VLAN Tag configurable
OPCOM3500E-8EOS-FE, OPCOM3500E-8EOS-FX Ethernet over SDH tributary
1 Ethernet optional optical or electrical port. EoS board, aggregates 1~8 VCGs to
one Ethernet port
OPCOM3500E-4EOS-4FE Ethernet over SDH tributary
4 Ethernet electrical port over 1~4 VCGs. EOS board, build-in Layer 2 Switch,
Double VLAN tag available

OPCOM3500E-EOP-FXE1*8, OPCOM3500E-EOP-FEE1*8 Ethernet over PDH


tributary
8 Fast-Ethernet ports, optional fiber optical ports and electrical ports, EoPDH board
OPCOM3500E-EOP-FE8E1, OPCOM3500E-EOP-FE16E1 Ethernet over PDH
tributary
One 10/100Base-Tx electrical port, EoPDH board, Inverse multiplexing
OPCOM3500E-EOPS-8E1 Ethernet over PDH and SDH tributary
8 E1 ports, a bridge of Ethernet over PDH network and Ethernet over SDH network

OPCOM3500E-STM1-S

Tributary unit, 2 STM-1 fiber links.


Dual STM-1 fiber link for individual directions or 1+1 protection
Total 63 VC12 capability
Automatic Laser Shutdown (ALS) function.

OPCOM3500E-STM1-S Application

OPCOM3500E-30x8

Tributary unit, includes 8 E1 fiber links.


8 independent PDH parts with 8 independent PDH optical interfaces.
Automatic Laser Shutdown (ALS) function.
Alarm indicator of local and remote equipment.
Dying Gasp: The indication of remote power down in NNM software
Build-in Bit Error test unit
Unframed or Framing E1 (time-slots configurable)

30x8 Application

OPCOM3500E-120x4 & 240x2


tributary unit of four PDH MUX parts, communicate with remote
PDH equipment through four PDH optical links.
120x4 has 4 PDH optical ports, each port capability is 4E1

240x2 has 2 PDH optical ports, each port capability is 8E1


Auto Laser Shut down (ALS)
Local and remote loop-back function of E1
LED Indicator can indicate local and remote alarm

On-line software up-grade

120x4 & 240x2 Application

OPCOM3500E-120EOSx4
OPCOM3500E-120FEx4-GE
Tributary unit of RCMS PDH ports
4 Multi-service fiber optical ports, each port capability is 100Mbps
wire speed Fast-Ethernet and 4E1

150Mbps bandwidth in fiber, 100M for Ethernet, 50M for E1 links


& Management information
E1 data will be mapped to VC12
Ethernet data in 120EOSx4 fiber will be mapped to VC12 by EOS
function, GFP and LAPS available
Ethernet data in 120FEx4-GE fiber will be aggregated to GE port
on front panel
Dying Gasp: LED indicator or software indication of remote Power
Down

OPCOM3500E-P240EOS
OPCOM3500E-P240FE
Tributary unit of RCMS PDH ports
1+1 protection line fiber
150Mbps bandwidth in fiber, 100M for Ethernet, 50M for 8
E1 links
& Management information

8 E1 links are mapped to VC12


The Ethernet data in P240EOS will be mapped to VC12
though EoS function
The Ethernet data in P240FE will be aggregated to FastEthernet port on front panel
GFP and LAPS
To communicate remote CPE RCMS2811 of 1+1
protection
Dying Gasp: LED indicator or software indication of remote
Power Down

120EOS, 120FE, P240EOS,


P240FE Application

OPCOM3500E-EOS(E)-8FX
OPCOM3500E-EOS-8FE
Tributary unit of Ethernet ports
8 Ethernet interface over 8 VCG individually
EOS-8FX: 8 x 100Mbps Ethernet optical interface
EOSE-8FX: 8 x 100Mbps Ethernet optical interface (VLAN ID
configurable)
EOS-8FE: 8 x 10/100Mbps Ethernet interface
8 links Ethernet service have rate limiting function with N*VC12 step,
and they can share maximum 63 VC12
GFP and LAPS encapsulation, and it supports LCAS function
Remote Raisecom 100M Media Converter can be network managed
On-line software up-grade of local equipment

EOSE-8FX EOS-8FE application

OPCOM3500E-8EOS-FX
OPCOM3500E-8EOS-FE
Tributary unit of Ethernet ports
Aggregate 1~8 VCG to single Fast-Ethernet aggregation
trunk
The Ethernet aggregation trunk port is on front panel or
connect to GE aggregation board through backboard
Optional fiber optical Ethernet interface or Electrical
Ethernet interface
GFP, LAPS available
VCAT, LCAS supportable
Maximum 8K MAC address, and 4096 VLAN ID
IEEE802.1q VLAN and Port VLAN, Q-in-Q double tag
4 output priority Queues
MTU up to 1632 bytes

On-line software up-grade of local equipment

8EOS-FX/FE application

OPCOM3500E-4EOS-4FE
Tributary unit of Ethernet ports
Multiple Application in EOS
Map 4 Fast-Ethernet port to 4 VCGs individually, similar
function as OPCOM3500E-EOS-4FE/8FE
Aggregate maximum 4 VCGs to one Fast-Ethernet,
similar function as OPCOM3500E-8EOS-FE
Map 4 Fast-Ethernet port to single VCG, VLAN tag
configurable
GFP, LAPS available
LCAS supportable
Maximum 8K MAC address, and 4096 VLAN ID
IEEE802.1q VLAN and Port VLAN, Q-in-Q double tag
4 output priority Queues
MTU up to 1632 bytes

On-line software up-grade of local equipment

4EOS-4FE Application
Multi VLAN over single VCG

OPCOM3500E-EOP-FXE1x8
OPCOM3500E-EOP-FEE1x8
Tributary unit of Ethernet ports
8 x 100M Ethernet interface service over single E1 (VC12)
EOP-FXE1x8 has 8 individual 100Mbps fiber optical Ethernet ports
EOP-FEE1x8 has 8 individual 10/100Mbps electrical Ethernet ports
Adopt SFP optical interface, plug and play
Each Ethernet link could be converted to one unframed of framing E1,
and could be rate limited with N*64Kbps DS0

Privately HDLC encapsulation with EoPDH Technology


Remote Raisecom 100M Media Converter can be network managed
On-line software up-grade of local equipment

EOP-FXE1x8 Application

OPCOM3500E-EOP-FE8E1
Tributary unit of Ethernet ports
Ethernet over 1~8 E1 Inverse Multiplexer inside
10/100Mbps electrical Ethernet port on front panel
8 E1 are mapped into VC12s to Aggregation Unit
Privately HDLC encapsulation with EoPDH Technology
On-line software up-grade of local equipment

EOP-FE8E1 Application

OPCOM3500E-EOPS-8E1
Tributary unit of Ethernet ports
Bridge the gap between EoPDH network and EoSDH network
8 E1 electrical port on front panel are used for connect to RC95x series
inverse multiplexer only
Convert E1 signals from front panel interface to Fast-Ethernet single by
EOP technology, and then convert the Fast-Ethernet signal to N*VC12
by EOS technology
GFP, LAPS available
LCAS, N-LCAS function

EOPS-8E1 Application

OPCOM3500E-16E1
OPCOM3500E-16E1 is E1 service unit of OPCOM3500,
it can provide 16 unbalanced E1 interfaces, and it
can be mapped in SDH frame through aggregate
unit of OPCOM3500
Provide complete alarm, performance monitor.

16E1 Application

OPCOM3500E
E1 links
STM-1/STM-4

2G BTS
Backup Ring

Aggregation Units Protection

STM-4 TM & ADM

Tributary Units Protection

Union NMS for All Raisecom


Equipments

Raisecom NNM GUI software

Thank you!

You might also like