SIMATIC
S7-GRAPH V5.2
S7-GRAPH V5.2
Enhancement and new Functions
New functions

Consistency check

New overview

Synchronization

Monitoring and
delay times

Adding symbols

Search for address
instances

Jump from
WinCC

New keyboard
operations

Order numbers,
date of delivery and
information
Automation and Drives
SIMATIC Industrial Software S7-GRAPH V5.2 Highlights A&D AS FA PS, 14.01.03, 2
S7-GRAPH V5.2
The consistency check of STEP 7 may be used for
S7-GRAPH blocks now:

After you have modified the program, it is now possible in
the SIMATIC Manager to check the consistancy of S7-
GRAPH blocks via the Check Block Consistancy function.

Still existing inconsitencies will be controlled and may
eliminated via the function Block (s) compile.
reduces the engineering for modification of blocks
and interfaces
this allows you to gain control over effects at other
blocks that result of interface modifications as well as
modifications in the symbol table and to quickly
eliminate errors
Consistency check
New functions

Consistency check

New overview

Synchronization

Monitoring and
delay times

Adding symbols

Search for address
instances

Jump from
WinCC

New keyboard
operations

Order numbers,
date of delivery and
information
Automation and Drives
SIMATIC Industrial Software S7-GRAPH V5.2 Highlights A&D AS FA PS, 14.01.03, 3
S7-GRAPH V5.2
The overview window now provides two new overviews of
the sequential control:

The graphics tab shows individual sequencers
as well as permanent instructions in a textual way


If required, you can
expand these views to
display more graphical
detail, e. g. the
sequencers structure or
individual operations.

New overview
New functions

Consistency check

New overview

Synchronization

Monitoring and
delay times

Adding symbols

Search for address
instances

Jump from
WinCC

New keyboard
operations

Order numbers,
date of delivery and
information
Automation and Drives
SIMATIC Industrial Software S7-GRAPH V5.2 Highlights A&D AS FA PS, 14.01.03, 4
S7-GRAPH V5.2
The sequencer tab shows all sequencers well
arranged side by side.
This presentation is especially useful for the
status display.
New overview
New functions

Consistency check

New overview

Synchronization

Monitoring and
delay times

Adding symbols

Search for address
instances

Jump from
WinCC

New keyboard
operations

Order numbers,
date of delivery and
information
Automation and Drives
SIMATIC Industrial Software S7-GRAPH V5.2 Highlights A&D AS FA PS, 14.01.03, 5
S7-GRAPH V5.2
You now have the choice of two
strategies for synchronization:
Actual: S7-GRAPH highlights all steps
whose previous transition condition is
satisfied and the conditions for
subsequent transition is not satisfied.
New: S7-GRAPH highlights all steps
whose interlock condition is satisfied
and the condition for a subsequent
transition is not satisfied.
Makes the change between
manual and automatic mode
easier.
You can select this strategy via menu
command
Options >
Application Settings >
General
Synchronization
Enhanced synchronization options
New functions

Consistency check

New overview

Synchronization

Monitoring and
delay times

Adding symbols

Search for address
instances

Jump from
WinCC

New keyboard
operations

Order numbers,
date of delivery and
information
Automation and Drives
SIMATIC Industrial Software S7-GRAPH V5.2 Highlights A&D AS FA PS, 14.01.03, 6
S7-GRAPH V5.2
Default values for monitoring and delay times

You can set default values for the addresses Si.T and Si.U,
you require for the watchdogs.

Reduced configuring overhead
for often used monitoring and
delay times

The settings are done via
Options >
Application Settings >
Editor
Monitoring and
delay times
New functions

Consistency check

New overview

Synchronization

Monitoring and
delay times

Adding symbols

Search for address
instances

Jump from
WinCC

New keyboard
operations

Order numbers,
date of delivery and
information
Automation and Drives
SIMATIC Industrial Software S7-GRAPH V5.2 Highlights A&D AS FA PS, 14.01.03, 7
S7-GRAPH V5.2
Enhanced functions for adding symbols
Depending on the position of the mouse cursor, you can now
open a context-sensitive menu command for assigning symbols
to several adresses.












Menu command: Edit Symbols
Adding symbols
New functions

Consistency check

New overview

Synchronization

Monitoring and
delay times

Adding symbols

Search for address
instances

Jump from
WinCC

New keyboard
operations

Order numbers,
date of delivery and
information
Automation and Drives
SIMATIC Industrial Software S7-GRAPH V5.2 Highlights A&D AS FA PS, 14.01.03, 8
S7-GRAPH V5.2
For displaying the instances of a selected address in
your program you have the following new options:

Search for address
instances
Double-click on a global address.
The S7 program searches for opposing
instances, that is, for write access addresses
it performs a search for read access
addresses and vice versa.

All instances of local addresses in the S7-
GRAPH block will be displayed via the menu
command
Go To > Previous / Next local use
New functions

Consistency check

New overview

Synchronization

Monitoring and
delay times

Adding symbols

Search for address
instances

Jump from
WinCC

New keyboard
operations

Order numbers,
date of delivery and
information
Automation and Drives
SIMATIC Industrial Software S7-GRAPH V5.2 Highlights A&D AS FA PS, 14.01.03, 9
S7-GRAPH V5.2
S7-GRAPH V5.2 supports the jump from WinCC via
the cross reference list to S7-GRAPH and to the still
active step in the read-only mode
allows depending on the user rights the
read-only access to the detailled sequencer
and to the active step.


Jump from
WinCC
New functions

Consistency check

New overview

Synchronization

Monitoring and
delay times

Adding symbols

Search for address
instances

Jump from
WinCC

New keyboard
operations

Order numbers,
date of delivery and
information
Automation and Drives
SIMATIC Industrial Software S7-GRAPH V5.2 Highlights A&D AS FA PS, 14.01.03, 10
S7-GRAPH V5.2
New keyboard operations for navigation
in the sequencer:

New keyboard
operations
Function Keys
To the start of the sequencer POS 1
To the end of the sequencer END
To the start of the jump SHIFT+POS 1
To the end of the jump SHIFT+END
New functions

Consistency check

New overview

Synchronization

Monitoring and
delay times

Adding symbols

Search for address
instances

Jump from
WinCC

New keyboard
operations

Order numbers,
date of delivery and
information
Automation and Drives
SIMATIC Industrial Software S7-GRAPH V5.2 Highlights A&D AS FA PS, 14.01.03, 11
S7-GRAPH V5.2
Order numbers:
6ES7 811-0CC05-0YX0 Single License
6ES7 811-0CC05-0YX4 Upgrade to V5.2
6ES7 811-0CA01-0YX2 Software Update Service

Date of delivery:
End of 12/2002
as a separate product and
as a component of STEP 7 Professional Edition 12/2002

Additional information to:
IEC 61131-3,
PLCopen and
S7-GRAPH Base Level certification

You will find in the Internet: http://www.plcopen.org/
Order numbers,
date of delivery and
information