Design for

Overpressure and
Underpressure
Protection
Slide Show Exit Slides with Text
SLIDE PRESENTATION
Design for
Overpressure and
Underpressure
Protection
HOME
NEXT
Outline
Introduction
Causes of Overpressure and
Underpressure
Reliefs
Effluent Handling Systems for
Reliefs
Runaway Reactions

Overpressure Protection for
Internal Fires and Explosions
Introduction
Reliefs
Runaways
Safeguards
For Further Information:
Refer to the Appendix
Supplied with this Presentation
NEXT
PREVIOUS
Text Home
Causes of Overpressure
Operating Problem
Equipment Failure
Process Upset
External Fire
Utility Failures
Home
NEXT
PREVIOUS
Text
Causes of Underpressures
Operating Problem
Equipment Failure
Home
NEXT
PREVIOUS
Text
Presentation 1 of 3: Reliefs
Causes of
Overpressure/Underpressure
Presentation 1: Reliefs
Presentation 2: Runaways
Presentation 3: Safeguards
Home
NEXT
PREVIOUS
Text
Pressure Relief Devices
Spring-Loaded Pressure Relief Valve
Rupture Disc
Buckling Pin
Miscellaneous Mechanical
Home
NEXT
PREVIOUS
Text
Spring-Loaded
Pressure Relief Valve
Home
NEXT
PREVIOUS
Text
Rupture Disc
Home
NEXT
PREVIOUS
Text
Buckling Pin Relief Valve
Closed
Pressure Below
Set Pressure
Full Open
Pressure at or Above
Set Pressure
(Buckles in Milliseconds at a Precise Set Pressure)
Home
NEXT
PREVIOUS
Text
Simple Mechanical
Pressure Relief
Home
NEXT
PREVIOUS
Text
Types of Spring-Loaded
Pressure Reliefs
Safety Valves for Gases and Vapors
Relief Valves for Liquids
Safety Relief Valves for Liquids
and/or Gases
Home
NEXT
PREVIOUS
Text
Types of Safety Valves
Conventional
Balanced Bellows, and
Pilot-Operated
Home
NEXT
PREVIOUS
Text
Conventional Safety Valve
Home
NEXT
PREVIOUS
Text
Balanced Bellows Safety Valve
Home
NEXT
PREVIOUS
Text
Pilot-Operated Safety Valve
Home
NEXT
PREVIOUS
Text
Types of Relief Valves
Conventional
Balanced Bellows
Home
NEXT
PREVIOUS
Text
Types of Rupture Discs
Metal
Graphite
Composite
Others
Home
NEXT
PREVIOUS
Text
Rupture Disc and Pressure
Relief Valve Combination
Home
NEXT
PREVIOUS
Text
Vacuum Relief Devices
Vacuum Relief Valves
Rupture Discs
Conservation Vents
Manhole Lids
Pressure Control
Home
NEXT
PREVIOUS
Text
Conservation Vent
Home
NEXT
PREVIOUS
Text
Pressure or Vacuum Control
Add Air or Nitrogen
Maintain Appropriately
Home
NEXT
PREVIOUS
Text
Relief Servicing
Inspection
Testing
Home
NEXT
PREVIOUS
Text
Relief Discharges
To Atmosphere
Prevented
Effluent System
Home
NEXT
PREVIOUS
Text
Effluent Systems
Knock-Out Drum
Catch Tank
Cyclone Separator
Home
NEXT
PREVIOUS
Text
Effluent System (continued)
Condenser
Quench Tank
Scrubber
Flares/Incinerators
Home
NEXT
PREVIOUS
Text
Effluent Handling System
Home
NEXT
PREVIOUS
Text
Presentation 2 of 3: Runaways
Home
NEXT
PREVIOUS
Text
Causes of
Overpressure/Underpressure
Presentation 1: Reliefs
Presentation 2: Runaways
Presentation 3: Safeguards
Runaway Reaction
Temperature Increases
Reaction Rate Increases
Pressure Increases
Home
NEXT
PREVIOUS
Text
Causes of Runaway Reactions
Self-Heating
Sleeper


Tempered
Gassy
Hybrid

Characteristics of Runaway
Home
NEXT
PREVIOUS
Text
Self-Heating Reaction
Loss of Cooling
Unexpected Addition of Heat
Too Much Catalyst or Reactant
Operator Mistakes
Too Fast Addition of Catalyst or Reactant
Home
NEXT
PREVIOUS
Text
Sleeper Reactions
Reactants Added But Not Mixed
(Error)
Reactants Accumulate
Agitation Started .. Too Late
Home
NEXT
PREVIOUS
Text
Tempered Reaction
Heat Removed by Evaporation
Heat Removal Maintains a Constant
Temperature
Home
NEXT
PREVIOUS
Text
Gassy System
No Volatile Solvents
Gas is Reaction Product
Home
NEXT
PREVIOUS
Text
Hybrid System
Tempered
Gassy
Home
NEXT
PREVIOUS
Text
Reliefs for Runaway Reactions
Two Phase (or Three Phases:
Liquid, Vapor, and Solid) Flow
Relief Area: 2 to 10 Times the
Area of a Single Gaseous Phase
Home
NEXT
PREVIOUS
Text
Two Phase Flow
Home
NEXT
PREVIOUS
Text
Relief Valve Sizing
Methodology
Special Calorimeter Data
Special Calculation Methods
Home
NEXT
PREVIOUS
Text
Characterization of
Runaway Reactions
ARC
VSP
RSST
APTAC
PHI-TEC
Dewars
Home
NEXT
PREVIOUS
Text
Presentation 3 of 3:
Safeguards
Home
NEXT
PREVIOUS
Text
Causes of
Overpressure/Underpressure
Presentation 1: Reliefs
Presentation 2: Runaways
Presentation 3: Safeguards
Safeguards
Safety Interlocks
Safeguard Maintenance System
Short-Stopping
Home
NEXT
PREVIOUS
Text
Safety Interlocks
Agitator Not Working: Stop Monomer
Feed and Add Full Cooling
Abnormal Temperature: Stop
Monomer Feed and Add Full Cooling
Home
NEXT
PREVIOUS
Text
Safety Interlocks
(continued)
Abnormal Pressure: Stop Monomer Feed
and Add Full Cooling
Abnormal Heat Balance: Stop Monomer
Feed and Add Full Cooling
Abnormal Conditions: Add Short-Stop
Home
NEXT
PREVIOUS
Text
Safeguard Maintenance
System
Routine Maintenance
Management of Change
Mechanical Integrity Checks
Records
Home
NEXT
PREVIOUS
Text
Short-Stops to Stop Reaction
Add Reaction Stopper
Add Agitation with No Electrical
Power
Home
NEXT
PREVIOUS
Text
Protection for Internal
Fires and Explosions
Deflagrations
Detonations
Home
NEXT
PREVIOUS
Text
Protection Methods for
Internal Fires and Explosions
Deflagration Venting
Deflagration Suppression
Containment
Home
NEXT
PREVIOUS
Text
Protection Methods for
Internal Fires and Explosions
(continued)
Reduction of Oxidant
Reduction of Combustible
Flame Front Isolation
Home
NEXT
PREVIOUS
Text
Protection Methods for
Internal Fires and Explosions
(continued)
Spark Detection and Extinguishing
Flame Detection and Extinguishing
Water Spray and Deluge Systems
Home
NEXT
PREVIOUS
Text
Deflagration Venting
Vent Area via NFPA 68
Vent Safely
Home
NEXT
PREVIOUS
Text
Vent of Gas Deflagration
Home
NEXT
PREVIOUS
Text
Vent of Dust Deflagration
Home
NEXT
PREVIOUS
Text
Deflagration Suppression
System
Home
NEXT
PREVIOUS
Text
Containment
Prevent Rupture and Vessel
Deformation
Prevent Rupture but Deform
Vessel
Home
NEXT
PREVIOUS
Text
Reduction of Oxidant
Vacuum Purging
Pressure Purging
Sweep-Through Purging
Home
NEXT
PREVIOUS
Text
Reduction of Combustible
Dilution with Air
NFPA 69
Home
NEXT
PREVIOUS
Text
Flame Front Isolation
Home
NEXT
PREVIOUS
Text
Spark/Flame Detection
and Extinguishing
Home
NEXT
PREVIOUS
Text
Water Spray or
Deluge Systems
Home
NEXT
PREVIOUS
Text
Deluge System
Home
NEXT
PREVIOUS
Text
Conclusion
Home
NEXT
PREVIOUS
Text
End of Slide Presentation
Home
NEXT
PREVIOUS
Causes of
Overpressure/Underpressure
Presentation 1: Reliefs
Presentation 2: Runaways
Presentation 3: Safeguards
Text
NEXT
PREVIOUS
Introduction
Reliefs
Runaways
Safeguards
Home
SLIDES WITH TEXT
Design for
Overpressure and
Underpressure
Protection
This presentation includes technical information
concerning the design for overpressure and
underpressure protection. The presentation is designed
to help students and engineers to:
Slide
NEXT
PREVIOUS
Introduction
Reliefs
Runaways
Safeguards
Home
Design for
Overpressure and
Underpressure
Protection
Understand the technologies, special engineering
devices, and methods that are used for the protection
against overpressure and underpressure (vacuum)
incidents,
Slide
NEXT
PREVIOUS
Introduction
Reliefs
Runaways
Safeguards
Home
Design for
Overpressure and
Underpressure
Protection
Understand the root causes of overpressure and
underpressure incidents, and
Design plants with the appropriate features to protect
against overpressure and underpressure incidents.
Slide
NEXT
PREVIOUS
Introduction
Reliefs
Runaways
Safeguards
Home
Six Sections
1. Introduction
2. Causes of Overpressure and
Underpressure
3. Reliefs
4. Effluent Handling Systems for Reliefs
5. Runaway Reactions, and
6. Overpressure Protection for Internal Fires
and Explosions
This presentation is divided into six sections:
Slide
NEXT
PREVIOUS
Introduction
Reliefs
Runaways
Safeguards
Six Sections
1. Introduction
2. Causes of Overpressure and
Underpressure
3. Reliefs
4. Effluent Handling Systems for Reliefs
5. Runaway Reactions, and
6. Overpressure Protection for Internal Fires
and Explosions
The Introduction button on your left will lead you to this
introduction and an explaination of the Causes of
Overpressure and Underpressure
Slide Home
NEXT
PREVIOUS
Introduction
Reliefs
Runaways
Safeguards
Six Sections
1. Introduction
2. Causes of Overpressure and
Underpressure
3. Reliefs
4. Effluent Handling Systems for Reliefs
5. Runaway Reactions, and
6. Overpressure Protection for Internal Fires
and Explosions
The Reliefs Button sends you to Sections 3 and 4,
covering Reliefs and Effluent Handling Systems for
Reliefs
Slide Home
NEXT
PREVIOUS
Introduction
Reliefs
Runaways
Safeguards
Six Sections
1. Introduction
2. Causes of Overpressure and
Underpressure
3. Reliefs
4. Effluent Handling Systems for Reliefs
5. Runaway Reactions, and
6. Overpressure Protection for Internal Fires
and Explosions
The Runaways Button leads to a discussion on
Runaway Reactions, and . . .
Slide Home
NEXT
PREVIOUS
Introduction
Reliefs
Runaways
Safeguards
Six Sections
1. Introduction
2. Causes of Overpressure and
Underpressure
3. Reliefs
4. Effluent Handling Systems for Reliefs
5. Runaway Reactions, and
6. Overpressure Protection for Internal Fires
and Explosions
The Safeguards Button will take you to a section on
Overpressure Protection fot Internal Fires and
Explosions
Slide Home
NEXT
PREVIOUS
Introduction
Reliefs
Runaways
Safeguards
Home
Appendix Contains
Detailed Information
This design package includes an appendix with detailed
information for each of the sections of this presentation.
The appendix also includes an extensive list of relevant
references.
Slide
NEXT
PREVIOUS
Introduction
Reliefs
Runaways
Safeguards
Home
Causes of Overpressure
Operating Problem
The major causes of overpressure include:
Operating problems or mistakes such as an operator mistakenly
opening or closing a valve to cause the vessel or system pressure to
increase. An operator, for example, may adjust a steam regulator to
give pressures exceeding the maximum allowable working pressure
(MAWP) of a steam jacket.
Slide
NEXT
PREVIOUS
Introduction
Reliefs
Runaways
Safeguards
Home
Causes of Overpressure
Operating Problem
Although the set pressure is usually at the MAWP, the design safety
factors should protect the vessel for higher pressures; a vessel fails when
the pressure is typically several times the MAWP.
Slide
NEXT
PREVIOUS
Introduction
Reliefs
Runaways
Safeguards
Home
Causes of Overpressure
Operating Problem
Equipment Failure
Equipment failures; for example a heat exchanger tube rupture that
increases the shell side pressure beyond the MAWP. Although the set
pressure is usually the MAWP, the design safety factors should protect
the vessel for higher pressures; a vessel fails when the pressure is
typically several times the MAWP.
Slide
NEXT
PREVIOUS
Introduction
Reliefs
Runaways
Safeguards
Home
Causes of Overpressure
Operating Problem
Equipment Failure
Process Upset
External Fire
Utility Failures
Process upset; for example a runaway reaction causing high
temperatures and pressures.
External heating, such as, a fire that heats the contents of a vessel
giving high vapor pressures, and
Utility failures, such as the loss of cooling or the loss of agitation
causing a runaway reaction.
Slide
NEXT
PREVIOUS
Introduction
Reliefs
Runaways
Safeguards
Home
Causes of Underpressures
The causes of underpressure or the inadvertent creation of a
vacuum are usually due to operating problems or equipment
failures.
Slide
NEXT
PREVIOUS
Introduction
Reliefs
Runaways
Safeguards
Home
Causes of Underpressures
Operating Problem
Operating problems include mistakes such as pumping liquid
out of a closed system, or cooling and condensing vapors in a
closed system.
Slide
NEXT
PREVIOUS
Introduction
Reliefs
Runaways
Safeguards
Home
Causes of Underpressures
Operating Problem
Equipment Failure
Equipment failures include an instrument malfunction (e.g.
vacuum gage) or the loss of the heat input of a system that
contains a material with a low vapor pressure.
Slide
NEXT
PREVIOUS
Introduction
Reliefs
Runaways
Safeguards
Home
Part 1 of 3: Reliefs
Slide
NEXT
PREVIOUS
Introduction
Reliefs
Runaways
Safeguards
Home
Pressure Relief Devices
Pressure relief devices are added to process equipment to
prevent the pressures from significantly exceeding the MAWP
(pressures are allowed to go slightly above the MAWP during
emergency reliefs).
Slide
NEXT
PREVIOUS
Introduction
Reliefs
Runaways
Safeguards
Home
Pressure Relief Devices
Spring-Loaded Pressure Relief Valve
Rupture Disc
Buckling Pin
Miscellaneous Mechanical
The pressure relief devices include spring-loaded pressure relief
valves, rupture discs, buckling pins, and miscellaneous
mechanical devices.
Slide
NEXT
PREVIOUS
Introduction
Reliefs
Runaways
Safeguards
Home
Spring-Loaded
Pressure Relief Valve
This is a sketch of a spring-loaded pressure relief valve. As the
pressure in the vessel or pipeline at point A exceeds the
pressure created by the spring, the valve opens. The relief
begins to open at the set pressure which is usually at or below
the MAWP; this pressure is usually set at the MAWP.
Slide
NEXT
PREVIOUS
Introduction
Reliefs
Runaways
Safeguards
Home
Rupture Disc
This is a sketch of a rupture disc. In this case the disc ruptures
when the pressure at A exceeds the set pressure. Recognize,
however, that it is actually the differential pressure (A-B), that
ruptures the disc.
Slide
NEXT
PREVIOUS
Introduction
Reliefs
Runaways
Safeguards
Home
Buckling Pin Relief Valve
Closed
Pressure Below
Set Pressure
Full Open
Pressure at or Above
Set Pressure
(Buckles in Milliseconds at a Precise Set Pressure)
This sketch shows a buckling pin pressure relief valve. As
shown, when the pressure exceeds the set pressure, the pin
buckles and the vessel contents exit through the open valve.
The rupture disc and the buckling pin relief valves stay open
after they are opened.
Slide
NEXT
PREVIOUS
Introduction
Reliefs
Runaways
Safeguards
Home
Buckling Pin Relief Valve
Closed
Pressure Below
Set Pressure
Full Open
Pressure at or Above
Set Pressure
(Buckles in Milliseconds at a Precise Set Pressure)
The spring operated valves close as the pressure decreases
below the blowdown pressure. The blowdown pressure is the
difference between the set pressure and closing pressure.
Slide
NEXT
PREVIOUS
Introduction
Reliefs
Runaways
Safeguards
Home
Simple Mechanical
Pressure Relief
A simple mechanical pressure relief is a weighted man-way
cover as shown in this sketch. Another mechanical relief is a U-
tube filled with water (or equivalent).
Slide
NEXT
PREVIOUS
Introduction
Reliefs
Runaways
Safeguards
Home
Types of Spring-Loaded
Pressure Reliefs
Safety Valves for Gases and Vapors
Relief Valves for Liquids
Safety Relief Valves for Liquids
and/or Gases
There are three types of spring-loaded pressure relief valves:
Safety valves are specifically designed for gases.
Relief valves are designed for liquids, and
Safety relief valves are designed for liquids and/or gases.

Slide
NEXT
PREVIOUS
Introduction
Reliefs
Runaways
Safeguards
Home
Types of Safety Valves
Conventional
Balanced Bellows, and
Pilot-Operated
There are three types of safety valves; that is:
Conventional,
Balanced bellows, and
Pilot-operated.
Slide
NEXT
PREVIOUS
Introduction
Reliefs
Runaways
Safeguards
Home
Conventional Safety Valve
A conventional safety valve is designed to provide full opening
with minimum overpressure. The disc is specially shaped to
give a pop action as the valve begins to open.
Slide
NEXT
PREVIOUS
Introduction
Reliefs
Runaways
Safeguards
Home
Balanced Bellows Safety Valve
A balanced bellows safety valve is specially designed to reduce
the effect of the back pressure on the opening pressure. As
illustrated in this sketch the differential pressure that is required
to open the valve is the pressure inside the vessel minus the
atmospheric pressure.
Slide
NEXT
PREVIOUS
Introduction
Reliefs
Runaways
Safeguards
Home
Balanced Bellows Safety Valve
The bellows design allows the outside air and pressure to be on
the downstream side of the valve seal. Once the relief is open,
then the flow is a function of the differential pressure A-B.
Slide
NEXT
PREVIOUS
Introduction
Reliefs
Runaways
Safeguards
Home
Pilot-Operated Safety Valve
A pilot-operated safety valve is a spring-loaded valve. As
illustrated, the vessel pressure helps to keep the valve closed.
When the pressure exceeds the set pressure (or the spring
pressure), the pressure on top of the valve is vented and the
valve opens.
Slide
NEXT
PREVIOUS
Introduction
Reliefs
Runaways
Safeguards
Home
Pilot-Operated Safety Valve
The set pressure of this type of valve can be closer to the
operating pressure compared to conventional and balanced
bellows valves. The disadvantages, however, are (a) the
process fluid needs to be clean, (b) the seals must be resistant
to the fluids, and (c) the seals and valves must be appropriately
maintained.
Slide
NEXT
PREVIOUS
Introduction
Reliefs
Runaways
Safeguards
Home
Pilot-Operated Safety Valve
These disadvantages are also true for spring operated reliefs.
Pilot-operated valves are not used in liquid service; they are
normally used in very clean and low pressure applications.
Slide
NEXT
PREVIOUS
Introduction
Reliefs
Runaways
Safeguards
Home
Types of Relief Valves
Conventional
Balanced Bellows
Relief valves (for liquid service) are either the conventional or
the balanced bellows types.
Slide
NEXT
PREVIOUS
Introduction
Reliefs
Runaways
Safeguards
Home
Types of Rupture Discs
Metal
Graphite
Composite
Others
As illustrated, there are many different types of rupture discs.
They are especially applicable for very corrosive environments;
for example: discs made of carbon or Teflon coating are used
for corrosive service.
Slide
NEXT
PREVIOUS
Introduction
Reliefs
Runaways
Safeguards
Home
Types of Rupture Discs
Metal
Graphite
Composite
Others
A rupture disc that is used for pressure reliefs may need a
specially designed mechanical support if it is also used in
vacuum service.

Slide
NEXT
PREVIOUS
Introduction
Reliefs
Runaways
Safeguards
Home
Rupture Disc and Pressure
Relief Valve Combination
Rupture discs, as illustrated, are sometimes used in
combination with a spring operated relief device. In this case
the disc gives a positive seal compared to the disc-to-seal
design of a spring operated valve.
Slide
NEXT
PREVIOUS
Introduction
Reliefs
Runaways
Safeguards
Home
Rupture Disc and Pressure
Relief Valve Combination
This is useful when handling very toxic materials where even a
very small release (through the seal) may be hazardous, or
when handling materials that polymerize.
The spring operated relief following the rupture disc reseats
when the pressure drops below the blow-down pressure.
Slide
NEXT
PREVIOUS
Introduction
Reliefs
Runaways
Safeguards
Home
Rupture Disc and Pressure
Relief Valve Combination
This design, therefore, stops the discharge from the vessel.
The discharge is not stopped if only a rupture disc is used. This
design (rupture disc followed by a spring-operated relief) is
discouraged by some practitioners.
Slide
NEXT
PREVIOUS
Introduction
Reliefs
Runaways
Safeguards
Home
Rupture Disc and Pressure
Relief Valve Combination
In this design, as illustrated, a pressure detection device (per
ASME Code), e.g., a pressure indicator, needs to be placed
between the disc and the spring-operated valve. This pressure
reading is checked periodically to be sure the rupture disc has
its mechanical integrity.
Slide
NEXT
PREVIOUS
Introduction
Reliefs
Runaways
Safeguards
Home
Rupture Disc and Pressure
Relief Valve Combination
A pin-hole leak in the rupture disc could increase the pressure
on the discharge side of the disc. This is a major problem
because it increases the relief pressure, that is: the differential
pressure across the disc is the rupturing mechanism.
Slide
NEXT
PREVIOUS
Introduction
Reliefs
Runaways
Safeguards
Home
Rupture Disc and Pressure
Relief Valve Combination
Another major problem with this design is the possibility that a
piece of the rupture disc could plug the discharge orifice of the
spring operated relief. This problem is prevented by specifying
a rupture disc that will maintain its integrity when it is ruptured;
that is, non-fragmenting.

Slide
NEXT
PREVIOUS
Introduction
Reliefs
Runaways
Safeguards
Home
Vacuum Relief Devices
Vacuum Relief Valves
Rupture Discs
Conservation Vents
Manhole Lids
Pressure Control
Vacuum relief devices are: vacuum relief valves, rupture discs,
conservation vents, manhole lids designed for vacuum relief,
and pressure control.
Slide
NEXT
PREVIOUS
Introduction
Reliefs
Runaways
Safeguards
Home
Conservation Vent
A conservation vent is illustrated in this sketch. As shown, it is
designed to relieve a pressure usually for pressures in the
region of 6 inches of water. It is also designed to let air into the
vessel to prevent a vacuum, usually a vacuum no more than 4
inches of water.
Slide
NEXT
PREVIOUS
Introduction
Reliefs
Runaways
Safeguards
Home
Pressure or Vacuum Control
Add Air or Nitrogen
Maintain Appropriately
Sometimes pressure or vacuum control systems are used to add air or
nitrogen to the vessel to maintain a slight pressure. In this case, the
system needs to be appropriately maintained because a malfunction
could result in an overpressure or underpressure. In either case the
consequence could be a ruptured vessel.
Slide
NEXT
PREVIOUS
Introduction
Reliefs
Runaways
Safeguards
Home
Relief Servicing
Inspection
Testing
Every relief device needs to be inspected and tested before
installation and then at predetermined intervals during its
lifetime. The interval depends on the service history, vendor
recommendations, and regulatory requirements, but it is usually
once a year.
Slide
NEXT
PREVIOUS
Introduction
Reliefs
Runaways
Safeguards
Home
Relief Servicing
Inspection
Testing
Operating results and experience may indicate shorter or longer
intervals.
Records must be carefully maintained for every inspection and
test, and for the entire life of the plant.

Slide
NEXT
PREVIOUS
Introduction
Reliefs
Runaways
Safeguards
Home
Relief Discharges
To Atmosphere
Discharges from pressure relief devices may be sent directly to
the atmosphere if they are innocuous, discharged in a safe
manner, and regulations permit it.
Slide
NEXT
PREVIOUS
Introduction
Reliefs
Runaways
Safeguards
Home
Relief Discharges
To Atmosphere
Prevented
An additional option is to prevent releases by (a) designing
vessels with high MAWPs to contain all overpressure scenarios,
or (b) add a sufficient number of safeguards and/or controls to
make overpressure scenarios essentially impossible.
Slide
NEXT
PREVIOUS
Introduction
Reliefs
Runaways
Safeguards
Home
Relief Discharges
To Atmosphere
Prevented
Effluent System
The third option is to design an effluent system to capture all
nocuous liquids and gases.

Slide
NEXT
PREVIOUS
Introduction
Reliefs
Runaways
Safeguards
Home
Effluent Systems
Knock-Out Drum
Catch Tank
Cyclone Separator
An effluent system may contain a
Knock-out drum
Catch tank
Cyclone separator
Slide
NEXT
PREVIOUS
Introduction
Reliefs
Runaways
Safeguards
Home
Effluent System (continued)
Condenser
Quench Tank
Scrubber
Flares/Incinerators
Condenser
Quench tank
Scrubber, and/or
Flares or incinerators
An effluent handling system may have any combination of the above unit
operations.

Slide
NEXT
PREVIOUS
Introduction
Reliefs
Runaways
Safeguards
Home
Effluent Handling System
One effluent handling system is illustrated in this sketch. Every
element of an effluent system needs to be designed very
carefully. The design requires detailed physical and chemical
properties, and the correct design methodology for each unit
operation.
Slide
NEXT
PREVIOUS
Introduction
Reliefs
Runaways
Safeguards
Home
Effluent Handling System
It should also be recognized that it is important to size the relief
appropriately, because the size of the entire effluent system is
based on this discharge rate. The design methodology is in the
references noted in the Appendix of this package.
Slide
NEXT
PREVIOUS
Introduction
Reliefs
Runaways
Safeguards
Home
Part 2 of 3: Runaways
Slide
NEXT
PREVIOUS
Introduction
Reliefs
Runaways
Safeguards
Home
Runaway Reaction
Temperature Increases
Reaction Rate Increases
Pressure Increases
A runaway reaction is an especially important overpressure scenario. A
runaway reaction has an accelerating rate of temperature increase, rate
of reaction increase, and usually rate of pressure increase. The
pressure, of course, increases if the reaction mass has a volatile
substance, such as, a solvent or a monomer; or if one of the reaction
products is a gas.
Slide
NEXT
PREVIOUS
Introduction
Reliefs
Runaways
Safeguards
Home
Causes of Runaway Reactions
Self-Heating
Sleeper


Tempered
Gassy
Hybrid

Characteristics of Runaway
In general, there are two causes of runaway reactions (self-
heating and sleeper) and three characteristics of runaways
(tempered, gassy, and hybrid).
Slide
NEXT
PREVIOUS
Introduction
Reliefs
Runaways
Safeguards
Home
Causes of Runaway Reactions
Self-Heating
Sleeper


Tempered
Gassy
Hybrid

Characteristics of Runaway
When protecting a system for overpressures due to runaway reactions
the engineer needs to know the type of runaway and needs to
characterize the behavior of the specific runaway with a special
calorimeter. This specific methodology is described in this section of this
presentation.
Slide
NEXT
PREVIOUS
Introduction
Reliefs
Runaways
Safeguards
Home
Self-Heating Reaction
Loss of Cooling
Unexpected Addition of Heat
Too Much Catalyst or Reactant
Operator Mistakes
Too Fast Addition of Catalyst or Reactant
One self-heating scenario occurs when the reaction is
exothermic and a loss of cooling gives an uncontrolled
temperature rise. A few causes of self-heating scenarios are
shown.
Slide
NEXT
PREVIOUS
Introduction
Reliefs
Runaways
Safeguards
Home
Sleeper Reactions
Reactants Added But Not Mixed
(Error)
Reactants Accumulate
Agitation Started .. Too Late
Sleeper reactions are usually the result of an operator error. Two
examples include: (a) the addition of two immiscible reactants when the
agitator is mistakenly in the off position, and (b) the addition of a reactant
to the reaction mass when the temperature is mistakenly lower than that
required to initiate the reaction.
Slide
NEXT
PREVIOUS
Introduction
Reliefs
Runaways
Safeguards
Home
Sleeper Reactions
Reactants Added But Not Mixed
(Error)
Reactants Accumulate
Agitation Started .. Too Late
In these cases the runaway is initiated by starting the agitator
and adding heat respectively.
Slide
NEXT
PREVIOUS
Introduction
Reliefs
Runaways
Safeguards
Home
Tempered Reaction
Heat Removed by Evaporation
Heat Removal Maintains a Constant
Temperature
Tempered runaway reactions maintain their temperature when the energy
exiting the relief device is equal to the energy generated in the reactor
due to the exothermic reaction. The reaction heat is absorbed by the
evaporation of the volatile components. The vapor pressure in a
tempered system can typically be characterized by an Antoine type
equation.
Slide
NEXT
PREVIOUS
Introduction
Reliefs
Runaways
Safeguards
Home
Gassy System
No Volatile Solvents
Gas is Reaction Product
A system that is characterized as gassy has no volatile
solvents or reactants. The pressure build-up is due to the
generation of noncondensible gas such as N
2
or CO
2
.

Slide
NEXT
PREVIOUS
Introduction
Reliefs
Runaways
Safeguards
Home
Hybrid System
Tempered
Gassy
A hybrid system is the combination of a tempered and a gassy
system. Under runaway conditions, the pressure increases due
to the vapor pressure of the volatile components as well as from
the generation of noncondensible gaseous reaction products.

Slide
NEXT
PREVIOUS
Introduction
Reliefs
Runaways
Safeguards
Home
Reliefs for Runaway Reactions
Two Phase (or Three Phases:
Liquid, Vapor, and Solid) Flow
Under runaway conditions, when the relief device opens, the
relief discharge is a foam; that is, the gases are entrained with
the liquid.
Slide
NEXT
PREVIOUS
Introduction
Reliefs
Runaways
Safeguards
Home
Reliefs for Runaway Reactions
Two Phase (or Three Phases:
Liquid, Vapor, and Solid) Flow
To maintain a constant temperature in the reactor (i.e. control the
runaway reaction), the relief valve is sized to remove all the heat
generated from the exothermic reaction via the heat removed with the
discharged mass, which is typically a foam. Detailed information on
runaway reactions is found in the appendix.
Slide
NEXT
PREVIOUS
Introduction
Reliefs
Runaways
Safeguards
Home
Reliefs for Runaway Reactions
Two Phase (or Three Phases:
Liquid, Vapor, and Solid) Flow
Relief Area: 2 to 10 Times the
Area of a Single Gaseous Phase
The required relief area to remove this heat with the foam is two
to ten times the area that would be required by releasing a
single gaseous phase.
Slide
NEXT
PREVIOUS
Introduction
Reliefs
Runaways
Safeguards
Home
Two Phase Flow
This is a picture that illustrates the two-phase flow
characteristics of a relief discharge due to a runaway reaction.
As illustrated, the discharge is similar to the release of foam
from a freshly opened bottle of pop after being shakened. If the
relief is not designed for two-phase flow, the pressures would
increase rapidly and the vessel could rupture.
Slide
NEXT
PREVIOUS
Introduction
Reliefs
Runaways
Safeguards
Home
Relief Valve Sizing
Methodology
Special Calorimeter Data
Special Calculation Methods
The relief valve sizing methodology for runaway reactions is
very complex. It requires the characterization of the runaway
reaction using a specially designed calorimeter.
Relief valve sizing, additionally, requires special calculation
methods that are described in the Appendix of this package.
Slide
NEXT
PREVIOUS
Introduction
Reliefs
Runaways
Safeguards
Home
Characterization of
Runaway Reactions
The characterization of runaway reactions includes the
determination of the rates of rise of the temperature and
pressure under adiabatic conditions. The test results also
characterize the reaction type, that is, tempered, gassy, and/or
a hybrid system.
Slide
NEXT
PREVIOUS
Introduction
Reliefs
Runaways
Safeguards
Home
Characterization of
Runaway Reactions
ARC
VSP
RSST
Various calorimeters are used for this characterization:
The accelerating rate calorimeter (ARC)
The vent sizing package (VSP)
The reactive system screening tool (RSST)
Slide
NEXT
PREVIOUS
Introduction
Reliefs
Runaways
Safeguards
Home
Characterization of
Runaway Reactions
ARC
VSP
RSST
APTAC
PHI-TEC
Dewars
The automated pressure-tracking adiabatic calorimeter (APTAC)
The Phi-Tec, and
Dewars.
Each of these calorimeters have advantages and disadvantages
that need to be understood when studying a specific system.
Slide
NEXT
PREVIOUS
Introduction
Reliefs
Runaways
Safeguards
Home
Part 3 of 3: Safeguards
Slide
NEXT
PREVIOUS
Introduction
Reliefs
Runaways
Safeguards
Home
Safeguards
This section of the presentation covers safeguards. Safeguards
include the methods and controls used to prevent runaways. As
illustrated previously, a containment system (a safeguard), can
be very complex and expensive. Alternatively, a series of
safeguards may be justified.
Slide
NEXT
PREVIOUS
Introduction
Reliefs
Runaways
Safeguards
Home
Safeguards
Safety Interlocks
Safeguard Maintenance System
Short-Stopping
Safeguards include safety interlocks, safeguard maintenance
system, and/or short-stopping.
Slide
NEXT
PREVIOUS
Introduction
Reliefs
Runaways
Safeguards
Home
Safety Interlocks
Agitator Not Working: Stop Monomer
Feed and Add Full Cooling
Abnormal Temperature: Stop
Monomer Feed and Add Full Cooling
The list of alternative interlocks is fairly extensive. Usually more than one
interlock and some redundancy and diversity is required for each
runaway scenario. As the number of interlocks increases, the reliability of
the system increases. These are examples of safety interlocks for a
semibatch polymerization reactor.
Slide
NEXT
PREVIOUS
Introduction
Reliefs
Runaways
Safeguards
Home
Safety Interlocks
(continued)
Abnormal Pressure: Stop Monomer Feed
and Add Full Cooling
Abnormal Heat Balance: Stop Monomer
Feed and Add Full Cooling
Abnormal Conditions: Add Short-Stop
This is a list of additional interlocks. Other interlocks (manual)
that are not on this list include: gages with manual shutdowns,
and alarms with manual shutdowns.
Slide
NEXT
PREVIOUS
Introduction
Reliefs
Runaways
Safeguards
Home
Safeguard Maintenance
System
Routine Maintenance
Management of Change
Mechanical Integrity Checks
Records
A safeguard maintenance system includes routine maintenance,
management of change, mechanical integrity checks, and the
appropriate records. These are the steps that are required to
be sure the safeguards and interlocks perform appropriately
under emergency conditions and/or potential runaway reaction
scenarios.
Slide
NEXT
PREVIOUS
Introduction
Reliefs
Runaways
Safeguards
Home
Safeguard Maintenance
System
Routine Maintenance
Management of Change
Mechanical Integrity Checks
Records
The maintenance of safeguard systems is especially important, because:
Safeguards and interlocks do not operate on a day-to-day basis, but
When they are required to operate (emergency conditions) they need
to operate flawlessly.
See ISA SP 84.01 for details for the design of safety instrumented
systems.
Slide
NEXT
PREVIOUS
Introduction
Reliefs
Runaways
Safeguards
Home
Short-Stops to Stop Reaction
Add Reaction Stopper
Add Agitation with No Electrical
Power
A short-stopping system, stops a runaway reaction by adding a
reaction stopper solution to the reacting mass. The reaction-stopper
stops the reaction in time to short-circuit the progress of the
reaction. A reaction stopper needs to be added when the reaction
mass is relatively cold. If the mass is too hot, a short-stopper will
not work.
Slide
NEXT
PREVIOUS
Introduction
Reliefs
Runaways
Safeguards
Home
Short-Stops to Stop Reaction
Add Reaction Stopper
Add Agitation with No Electrical
Power
Good agitation, of course, is required to adequately mix the reaction
mass with the inhibitor. Since a power failure is often the initiating
event of a runaway, an alternative method of agitation needs to be
included in the design. A compressed nitrogen system together with
a sparge ring is one alternative.
Slide
NEXT
PREVIOUS
Introduction
Reliefs
Runaways
Safeguards
Home
Protection for Internal
Fires and Explosions
Deflagrations
Detonations
This section of the presentation covers protection methods for
internal fires and explosions.
Overpressure protection is needed for process equipment that
can potentially explode due to an internal deflagration or
detonation.
Slide
NEXT
PREVIOUS
Introduction
Reliefs
Runaways
Safeguards
Home
Protection for Internal
Fires and Explosions
Deflagrations
Detonations
A deflagration is defined as the propagation of a combustion
zone at a velocity in the unreacted medium that is less than the
speed of sound. A detonation has a velocity greater than the
speed of sound in the unreacted medium.
Slide
NEXT
PREVIOUS
Introduction
Reliefs
Runaways
Safeguards
Home
Protection for Internal
Fires and Explosions
Deflagrations
Detonations
The burning material can be a combustible gas, a combustible
dust, a combustible mist, or a hybrid mixture (a mixture of a
combustible gas with either a combustible dust or combustible
mist). The reaction actually occurs in the vapor phase between
the fuel and the air or some other oxidant.
Slide
NEXT
PREVIOUS
Introduction
Reliefs
Runaways
Safeguards
Home
Protection Methods for
Internal Fires and Explosions
Deflagration Venting
Deflagration Suppression
Containment
The protection methods used for fires or explosions include
Deflagration venting
Deflagration suppression
Containment

Slide
NEXT
PREVIOUS
Introduction
Reliefs
Runaways
Safeguards
Home
Protection Methods for
Internal Fires and Explosions
(continued)
Reduction of Oxidant
Reduction of Combustible
Flame Front Isolation
Reduction of the oxidant
Reduction of the combustible
Flame front isolation
Slide
NEXT
PREVIOUS
Introduction
Reliefs
Runaways
Safeguards
Home
Protection Methods for
Internal Fires and Explosions
(continued)
Spark Detection and Extinguishing
Flame Detection and Extinguishing
Water Spray and Deluge Systems
Spark detection and extinguishing
Flame detection and extinguishing
Water or foam spray deluge systems
Slide
NEXT
PREVIOUS
Introduction
Reliefs
Runaways
Safeguards
Home
Deflagration Venting
Vent Area via NFPA 68
The technology required for venting deflagrations is given in
NFPA 68. Deflagration venting is usually the simplest and least
costly means of protecting process equipment against damage
due to the internal pressure rise from deflagrations.
Slide
NEXT
PREVIOUS
Introduction
Reliefs
Runaways
Safeguards
Home
Deflagration Venting
Vent Area via NFPA 68
Vent Safely
If equipment is located inside a building, the vents must be
discharged through a vent duct system to a safe location
outside of the building. The design of the vent duct system is
critical to avoid excessive pressures developed during the
venting process. See NFPA 68 for details.
Slide
NEXT
PREVIOUS
Introduction
Reliefs
Runaways
Safeguards
Home
Deflagration Venting
Vent Area via NFPA 68
Vent Safely
A safe location will avoid injury to personnel and minimize
damage to equipment outside of the building. The next two
pictures illustrate that the safe venting may not be trivial.
Slide
NEXT
PREVIOUS
Introduction
Reliefs
Runaways
Safeguards
Home
Vent of Gas Deflagration
This is a picture of the venting of a gas deflagration. As illustrated,
the flame propagates a significant distance from the vessel. The
length of the flame is estimated using an equation found in NFPA
68. The main purpose of venting is to protect the mechanical
integrity of the equipment. As illustrated, even when it is vented
safely, this is a major event.
Slide
NEXT
PREVIOUS
Introduction
Reliefs
Runaways
Safeguards
Home
Vent of Dust Deflagration
This is a picture of the venting of a dust deflagration. As illustrated,
the burning dust continues to burn at great distances from the vent.
With dusts, this burning zone is larger because the container has a
larger fuel-to-air ratio compared to the gas deflagration scenario.
These pictures clearly illustrate the problems with venting
deflagrations.
Slide
NEXT
PREVIOUS
Introduction
Reliefs
Runaways
Safeguards
Home
Deflagration Suppression
System
One alternative to venting a deflagration is suppression. This
sketch illustrates a deflagration suppression system that
includes (a) a flame or pressure detector, (b) a quick opening
valve, and (c) the addition of a flame suppressant.
Slide
NEXT
PREVIOUS
Introduction
Reliefs
Runaways
Safeguards
Home
Deflagration Suppression
System
The commonly used suppression agents include water,
potassium acid phosphate, sodium bicarbonate, and Halon
substitutes. The technology for deflagration suppression is
described in NFPA 69.
Slide
NEXT
PREVIOUS
Introduction
Reliefs
Runaways
Safeguards
Home
Containment
Prevent Rupture and Vessel
Deformation
Prevent Rupture but Deform
Vessel
The thickness of vessel walls may be increased to contain the
pressure of a deflagration.
The wall thickness can be large enough to prevent the
deformation of the vessel, or
The wall thickness may be large enough to prevent a rupture, but
allow the vessel to deform.
Slide
NEXT
PREVIOUS
Introduction
Reliefs
Runaways
Safeguards
Home
Reduction of Oxidant
Vacuum Purging
Pressure Purging
Sweep-Through Purging
Protection for overpressures is also provided with an inert gas
blanket to prevent the occurrence of a deflagration. Before
introducing a flammable substance to a vessel, the vessel must
also be purged with an inert gas to reduce the oxidant
concentration sufficiently so that the gas mixture cannot burn.
Slide
NEXT
PREVIOUS
Introduction
Reliefs
Runaways
Safeguards
Home
Reduction of Oxidant
Vacuum Purging
Pressure Purging
Sweep-Through Purging
The purging methods include vacuum purging, pressure
purging, and sweep-through purging. See NFPA 69 and the
book by Crowl and Louvar for more details.
Slide
NEXT
PREVIOUS
Introduction
Reliefs
Runaways
Safeguards
Home
Reduction of Combustible
Dilution with Air
NFPA 69
A deflagration can also be prevented by reducing the concentration
of the combustible material so that the concentration is below the
lower flammability limit (LFL). This is usually accomplished by
dilution with nitrogen. The specifications for this type system are
given in NFPA 69.
Slide
NEXT
PREVIOUS
Introduction
Reliefs
Runaways
Safeguards
Home
Flame Front Isolation
As illustrated, isolation devices are used in piping systems to prevent the
propagation of a flame front. The method illustrated has a fast-acting
block valve.
This isolation system prevents the propagation of the flame front; more
importantly it prevents deflagration transitions to detonations.
Slide
NEXT
PREVIOUS
Introduction
Reliefs
Runaways
Safeguards
Home
Spark/Flame Detection
and Extinguishing
Another method of preventing the propagation of deflagrations in
pipelines is the early detection and extinguishment of sparks or flames.
In this type system, a detector activates an automatic extinguishing
system that sprays water or other extinguishing agents into the fire. This
system is similar to the deflagration suppression system discussed
previously.
Slide
NEXT
PREVIOUS
Introduction
Reliefs
Runaways
Safeguards
Home
Water Spray or
Deluge Systems
Process equipment and structures are very effectively protected against
fire by water spray or deluge systems. They can be activated manually
or automatically. They are designed to cool the equipment or structural
members so that the heat from a fire will not weaken them.
Slide
NEXT
PREVIOUS
Introduction
Reliefs
Runaways
Safeguards
Home
Deluge System
This picture shows a typical deluge system in operation. In this
example, the deluge system is automatically activated when the
concentration of the flammable gas below the vessel is detected
to be at or over 25% of the lower flammability limit.
Slide
NEXT
PREVIOUS
Introduction
Reliefs
Runaways
Safeguards
Home
Conclusion
This concludes our technology package covering overpressure and
underpressure protection. The appendix of this package contains
more detailed information. The enclosed references contain the
state-of-the-art technology to assist engineers and students with
their detailed designs.
Slide
End of Slide Presentation
(with text)
HOME
PREVIOUS
Causes of
Overpressure/Underpressure
Presentation 1: Reliefs
Presentation 2: Runaways
Presentation 3: Safeguards