D-R 290

Dust and Opacity


Monitor
Seite 2
D-R 290 Dust and Opacity Monitor
Seite 3
Specifications of D-R 290
Measuring range 0-200 / 4000 mg/m
3
per meter
Light source Super wide band diode SWBD
Optical density 0.1 - 1.6 optical density (Ext)
Opacity 20 - 100 %, stack exit correction
Length of measuring path 1 - 12 m, only two reflectors
Bus interface optionally Modbus
Output signal 2 x 0-20 mA, 4mA Zero
Range switching external and automatic (optional)
Relay input/outputs 6 x status, potential free
Integration time 5 1800 seconds
Ambient temperature -20 - +50 C
Mains 95-264 V, 48-62 Hz, 30 W (Monitor)
115/230V, 50/60 Hz, 400 W (Fan)
Seite 4
D R 290 System Components
D-R 290 AW
Optical Measuring Unit
Reflector Unit
Evaluation Unit Purge Air Fan
Reflector 1: 1 2.25 m

Reflector 2: 1.75-12 m
(special execution: <18m)
Seite 5
System Components
1. Evaluation Unit
2. Measuring Head
3. Reflector
4. Adjuster Flange
5. Purge Air Fan
6. Recorder
7. Weather Hoods
Head&Reflector
8. Weather Hood
Blower
9. Fail Safe Shutter
10. Control Unit for
Shutter
Seite 6
D-R 290 Control Panel
Display of
- mA
- Opacity
- Optical Density
- mg/m
3

Easy to operate
No computer required for
set-up
Data entry by four key
menu

OUTPUT 1 00:01
Op 85.5% 17.68mA
Seite 7
Easy 4-key Operating
LED LED
MOD STO
Display measured values
Display parameters
Undo data modification

Data entry
Store data

Select measured data from channel 1 / 2
Select parameter
Increase digit value

Select digit / move cursor
STO
MOD
+
STOMOD
+
Seite 8
D-R 290 On-Stack and Remote Control Unit
Standard: On-Stack Display
Optional: Remote Control
Housing: Wall (IP68) or Rack Mounting
2 ... max. 10 m
2 ... max. 10 m max. 1000 m
Evaluation Unit
Display Unit Evaluation Unit
mA
Option
MODBUS
mA
Option
MODBUS
Seite 9
D-R 290 Dust Concentration and Opacity Monitor
Seite 10
Main Board Measuring Head
S1 = Watch dog timer
S2 = Enable S6
S3 = Enable S4
S4/1 = Output slope
S4/2 = Control mode slope
S4/3 = Span slope
S4/4 = Offset Zero intern
S4/5 = Offset Zero extern
S4/6 = Basic adjust locked
S5 = Data entry enable
S6 = Service switch
S7 = Increase
S8 = Decrease
S9 = Temperature
Compensation (optional)
P1 = Offset setting
1 234 56
OFF
P1
S5 S8 S7 S4 S1
S6 S2
D-R 290 MK No 21
gelb
yellow
rot
red
Abgleich
Adjustment
Speichern Freigabe
Storage release
on
off
on
off
S3
Speichern Freigabe
Storage release
Abgleich
Adjustment
gesperrt
locked
123456 7 8
OFF
S9
d
r
w
_
r
2
9
0
_
0
2
3
_
0
2
_
M
K

N
o
2
1
Seite 11
Customer length Calibration
Mount instrument on calibration flanges in a dust-free environment, at the
exact distance as measuring path length and power on.
Set switch S2/S3 up, check the optical alignment & make it perfect & set
S2/S3 down.
Press switch S5 towards left.
The yellow LED starts blinking & system will automatically start calibration
cycle.
- LED Int. CALIB
- Zero point INTERNAL calibration.
- Span calibration
- Zero point EXTERNAL calibration
- Zero point check
- Window check
- Span check
Normal operation
Manually fine adjustment S2 / S3, S4|4 (int), S4|5 (ext) & S7&S8
Seite 12
Error Messages
data transfer Err 000 R6 R5
contamination exceeded Err 001 R5
message external 1 AW Err 002 R5
message external 2 AW Err 003 R5
EEPROM Err 004 R5
RAM Err 005 R6 R5
PROM Err 006 R6 R5
AW-System Err 007 R6 R5
comparison Err 010 R5 R5= Error
zero point external Err 020 R5
zero point internal Err 030 R5 R6= System fault
stepper motor Err 040 R6 R5
LED Error Err 050 R6 R5
heated window Err 060 R5
optic head Err 070 R6 R5
message input 1 AZ Err 100 R5
message input 2 AZ Err 200 R5
message input 3 AZ Err 300 R5
message input 4 AZ Err 400 R5
message input 5 AZ Err 500 R5
message input 6 AZ Err 600 R5
AZ-System Err 700 R6 R5
Maintenance Works:
Cleaning of optical lenses
Cleaning of blower filters
Cleaning of External parts
Check the alignment of the instrument

Seite 13