Monitor Seite 2 D-R 290 Dust and Opacity Monitor Seite 3 Specifications of D-R 290 Measuring range 0-200 / 4000 mg/m 3 per meter Light source Super wide band diode SWBD Optical density 0.1 - 1.6 optical density (Ext) Opacity 20 - 100 %, stack exit correction Length of measuring path 1 - 12 m, only two reflectors Bus interface optionally Modbus Output signal 2 x 0-20 mA, 4mA Zero Range switching external and automatic (optional) Relay input/outputs 6 x status, potential free Integration time 5 1800 seconds Ambient temperature -20 - +50 C Mains 95-264 V, 48-62 Hz, 30 W (Monitor) 115/230V, 50/60 Hz, 400 W (Fan) Seite 4 D R 290 System Components D-R 290 AW Optical Measuring Unit Reflector Unit Evaluation Unit Purge Air Fan Reflector 1: 1 2.25 m
Reflector 2: 1.75-12 m (special execution: <18m) Seite 5 System Components 1. Evaluation Unit 2. Measuring Head 3. Reflector 4. Adjuster Flange 5. Purge Air Fan 6. Recorder 7. Weather Hoods Head&Reflector 8. Weather Hood Blower 9. Fail Safe Shutter 10. Control Unit for Shutter Seite 6 D-R 290 Control Panel Display of - mA - Opacity - Optical Density - mg/m 3
Easy to operate No computer required for set-up Data entry by four key menu
OUTPUT 1 00:01 Op 85.5% 17.68mA Seite 7 Easy 4-key Operating LED LED MOD STO Display measured values Display parameters Undo data modification
Data entry Store data
Select measured data from channel 1 / 2 Select parameter Increase digit value
Select digit / move cursor STO MOD + STOMOD + Seite 8 D-R 290 On-Stack and Remote Control Unit Standard: On-Stack Display Optional: Remote Control Housing: Wall (IP68) or Rack Mounting 2 ... max. 10 m 2 ... max. 10 m max. 1000 m Evaluation Unit Display Unit Evaluation Unit mA Option MODBUS mA Option MODBUS Seite 9 D-R 290 Dust Concentration and Opacity Monitor Seite 10 Main Board Measuring Head S1 = Watch dog timer S2 = Enable S6 S3 = Enable S4 S4/1 = Output slope S4/2 = Control mode slope S4/3 = Span slope S4/4 = Offset Zero intern S4/5 = Offset Zero extern S4/6 = Basic adjust locked S5 = Data entry enable S6 = Service switch S7 = Increase S8 = Decrease S9 = Temperature Compensation (optional) P1 = Offset setting 1 234 56 OFF P1 S5 S8 S7 S4 S1 S6 S2 D-R 290 MK No 21 gelb yellow rot red Abgleich Adjustment Speichern Freigabe Storage release on off on off S3 Speichern Freigabe Storage release Abgleich Adjustment gesperrt locked 123456 7 8 OFF S9 d r w _ r 2 9 0 _ 0 2 3 _ 0 2 _ M K
N o 2 1 Seite 11 Customer length Calibration Mount instrument on calibration flanges in a dust-free environment, at the exact distance as measuring path length and power on. Set switch S2/S3 up, check the optical alignment & make it perfect & set S2/S3 down. Press switch S5 towards left. The yellow LED starts blinking & system will automatically start calibration cycle. - LED Int. CALIB - Zero point INTERNAL calibration. - Span calibration - Zero point EXTERNAL calibration - Zero point check - Window check - Span check Normal operation Manually fine adjustment S2 / S3, S4|4 (int), S4|5 (ext) & S7&S8 Seite 12 Error Messages data transfer Err 000 R6 R5 contamination exceeded Err 001 R5 message external 1 AW Err 002 R5 message external 2 AW Err 003 R5 EEPROM Err 004 R5 RAM Err 005 R6 R5 PROM Err 006 R6 R5 AW-System Err 007 R6 R5 comparison Err 010 R5 R5= Error zero point external Err 020 R5 zero point internal Err 030 R5 R6= System fault stepper motor Err 040 R6 R5 LED Error Err 050 R6 R5 heated window Err 060 R5 optic head Err 070 R6 R5 message input 1 AZ Err 100 R5 message input 2 AZ Err 200 R5 message input 3 AZ Err 300 R5 message input 4 AZ Err 400 R5 message input 5 AZ Err 500 R5 message input 6 AZ Err 600 R5 AZ-System Err 700 R6 R5 Maintenance Works: Cleaning of optical lenses Cleaning of blower filters Cleaning of External parts Check the alignment of the instrument