INSTALLATION GUIDE 1

Pasolink V4 Training Course.


I NSTALLATI ONS GUI DE
CHAPTER 03
INSTALLATION GUIDE 2
1. Preparations
Before going to any site, please be sure you completely prepared the following items:

1. The installation tools.

2. The test equipment ,materials ,and tools.( for test work only)

3. Site installation drawings.

4. All labels/stickers (hard and soft copy)

5. Frequency plan and system configuration documents.

6. Test procedure and test data sheets .( for test work only)

7. Confirm access to site/station.

8. Check the condition of the vehicle to be used.

9. Make sure you and your staff are in good conditions (physically)

10. Confirm the site/station entrance conditions.

11. Move to site/station safely.

INSTALLATION GUIDE 3


IF Cable
Connection
IDU Grounding Connection
Connect the Power Follow Start up and set up Procedure
Follow The termination Procedure
I DU Mounting
19" rack fixing
Unpacking of 19" rack (if
supplied)
IF Connector & Power Connector termination
Unpacking of Accessories Unpacking of IDU
Refer to the IDU fixing Procedure
Photos
Rack Earthing Connection
Confirm 19" Rack Location
& DC-Power Source
2. Indoor Installations Flow Chart
INSTALLATION GUIDE 4
2-1 UNPACKING IDU / ODU
Open the carton
Take out the cushioning materials
Take out the IDU with the antistatic bag from the carton
Take out the IDU from the antistatic bag
Open the carton
Take out the ODU with the cushioning materials
Remove the cushioning material from the ODU
Inspect ODU
Inspect IDU
INSTALLATION GUIDE 5
2-3 IDU MOUNT
FRONT POSITION
CENTER POSITION
Fix each side of the IDU to the rack with
(M5) screws
Align the IDU to the mount position
When mounting the IDU in a 19 inch
rack, leave a space of 200mm to the rear
section and space of one rack unit to the
top and bottom.
WALL
Mount the two brackets to the IDU with
four screws
Align the IDU to the center mount position and
fix each side with (M5) screws
INSTALLATION GUIDE 6


IF Cable Connection
ODU Grounding Connection
IF Cable Laying
Connect to IDU & Follow Start up and set
up Procedure
Follow The termination
Procedure
ODU
Mounting
Unpacking of Antenna
IF Connector
Unpacking of
Accessories
Unpacking of
ODU
Refer to the IDU fixing Procedure
Photos
Remove the ODU cover,
Confirm the Polarity
Antenna bracket assembling,
Confirm the Polarity
Refer to the Antenna assembling
guide
3. Outdoor Installations Flow Chart
INSTALLATION GUIDE 7
3-1 (1+1) V /H POLARIZATION SETTINGS (1/2)
PROCEDURE FOR SETTING V/H POLARIZATION
ANTENNA
Antenna is set to V polarization when shipped from
the factory
To change to H polarization, loosen the four screws and
rotate the antenna connection unit by 90 degrees. Then
tighten the screws.
NEC HYBRID UNIT
Hybrid is set to V polarization when shipped from the
factory
To change to H polarization, loosen the two screws and rotate
the two plates as shown and fix it back.
Antenna direct
mounting type
ODU
Antenna
connection
unit
V-POL
H-POL
Screws
HYB
RID
INSTALLATION GUIDE 8
V-POL
H-POL
Hybrid is set to V polarization when shipped
from the factory
To change to H polarization, loosen the two screws
and rotate the three plates as shown and fix it back.
3-1 (1+1) V /H POLARIZATION SETTINGS (2/2)
INSTALLATION GUIDE 9
3-2 ANTENNA DIRECT MOUNT V/H POL
PROCEDURE FOR SETTING V/H POLARIZATION
When vertical polarization is required, rotate the
ODU so that the plate marked with V is pointing
up. Fix the ODU in this position
When horizontal polarization is required, rotate
the ODU so that the plate marked with H is
pointing up. Fix the ODU in this position
INSTALLATION GUIDE 10
3-3 POLE MOUNTING BRACKET
INSTALLATION GUIDE 11
3-4 WALL MOUNTING BRACKET
BOLT
INSTALLATION GUIDE 12
3-5 Antenna Direct Mount Type
1. Mount the Hybrid to the Antenna with screws,
use the guide pins to position correctly
2. Fix the ODUs one by one to the Hybrid. Take care
not to damage the o-rings.
Remove the Blanking plate
Mount the blanking plate
here for reuse
INSTALLATION GUIDE 13
3-6 7/8 GHz ODU CONNECTIONS
USING NEC HYBRID USING QUASAR HYBRID
INSTALLATION GUIDE 14
3-7 Antenna connection using WG
WAVEGUIDE WITH PBR [ ] FLANGE
INSTALLATION GUIDE 15
3-8 O-RING INSTALLATION RULE
1. Two (small and large) O-rings are attached in 18-52
GHz band Andrew/RFS direct mount antenna. Table 2
Show how to use small and Large O-Rings

2. 13/15 GHz band antenna does not have small O-ring
(Small O-ring is not used for Andrew/RFS direct mount
antenna).

3. If the small O-ring is used for ODU direct mount
installation, a gap may occur between ODU and antenna
for RF interface. This may cause transmit or receive
level down.
Table 2 How to use O-Rings
INSTALLATION GUIDE 16
4. FRAME GROUNDING (1/2)
In mounting IDU and ODU, perform frame
grounding.

Location of frame grounding in each of the IDU
and ODU is shown in Fig. 1, and Fig.2


Fig.1 Location of Frame Ground
Fig.2 Location of Frame Ground
INSTALLATION GUIDE 17
4. FRAME GROUNDING (2/2)
Fig.2 Connection for Frame Grounding
INSTALLATION GUIDE 18
5. Cable Termination
This section describes the cable termination method. The necessary tools
and materials are summarized in Table 1.

The following cables are described for reference.
D-sub connector
N-P connector of the L angle type
N-P connector of the straight type
Molex M5557-4R connector

Note: Use ISO standardized screw (mm unit) for D-SUB connector.
Table 1 Tools and Material List
INSTALLATION GUIDE 19
5-1 Terminating Supervisory Cables with D-Sub Connector (1/4)
Step 1. Strip back the cable sheath, taking care not to damage the
braided Shield.
Step 2. Fold back the braided shield
(donot separate the strands) and trim it as shown,
Step 3. Remove the insulation over a length of 4 mm from the end of
the wire,
CONFORMABLE
WIRE SOCKET CONTACT

AWG#20-24 : CD-PC-111
AWG#24-28 : CD-PC-121
Step 4. Insert the cable into the socket contact,
Step 5. Cable should be fitted, so that insulation and bare wire are
arranged as shown,
INSTALLATION GUIDE 20
5-1 Terminating Supervisory Cables with D-Sub Connector (2/4)
Step 6. Mount the socket contact using a hand crimping tool

CONFORMING
WIRE SOCKET CONTACT

AWG#20-24 : TC-CD-111
AWG#24-28 : TC-CD-121
Step 7. Recheck that the wire position is as shown in step 5 before
crimping the socket contact (see illustration at left),
INSTALLATION GUIDE 21
5-1 Terminating Supervisory Cables with D-Sub Connector (3/4)
Step 8. Wind the metallic shield tape on the braided shield,
Step 9. Set the cable into the plug case as shown in figure,
Then, fit the cable using the cable clamper and two screws
INSTALLATION GUIDE 22
5-1 Terminating Supervisory Cables with D-Sub Connector (4/4)
Step 10. Referring to circle A, fix drain wire with screw,
Step 11. Referring to circle B,
insert each wire to the specified position,
Insert the socket contacts into the upper and lower row
positions while taking care that the socket contacts are
inserted the right way round.
Step 12. Fix the plug case with two screws, as shown in the
figure.
INSTALLATION GUIDE 23
5-2 Terminating Coaxial (IF Signal) with N-P Connector (L Angle Type) (1/3)
Step 1. First fit the tying metal, washer and gasket
on the cable,
Step 2. Strip back the cable sheath, taking care
not to damage the braided shield, and fit the
clamp
Step 3. Fold back the braided shield (separating
the strands of the braid) and trim it,
Step 4. Insert the ferrule,
INSTALLATION GUIDE 24
5-2 Terminating Coaxial (IF Signal) with N-P Connector (L Angle Type) (2/3)
Step 5. Fit the bush,
Step 6. Cut the aluminium fail and inner
insulator away along the bush and remain the
inner conductor,
Step 7. Taper the edge of the center
conductor using a file as shown in the
circle,
INSTALLATION GUIDE 25
5-2 Terminating Coaxial (IF Signal) with N-P Connector (L Angle Type) (3/3)
Step 8. Mount the contact onto the center conductor
and mount insulator onto the contact,
Step 9. Insert the cable into the shell,
Step 10. Tighten tying metal with wrench point
by wrench (Tighten with torque 4 to 10 N m).
INSTALLATION GUIDE 26
5-3 Terminating Coaxial (IF Signal) with N-P Connector (Straight Type) (1/2)
Step 1. First fit the lock nut, washer and gasket on the
cable as shown,
Step 2. Strip back the cable sheath, taking care not to damage
the braided shield, and fit the clamp A,
Step 3. Fold back the braided shield (separating the
strands of the braid) and trim it,
Step 4. Cut away the insulation from the center conductor and
fit the clamp B. Be sure not to cut or scratch the conductor
while stripping the insulation,
INSTALLATION GUIDE 27
5-3 Terminating Coaxial (IF Signal) with N-P Connector (Straight Type) (2/2)
Step 5. Cut the center conductor. Taper the end of the center
conductor using a fie as shown in the circle,
Step 6. Mount the center contact onto the center
conductor as shown,
Note: Insert the center contact into insulator
(1.5mm).
Step 7. Mount the insulation onto the center contact,
Step 8. Insert the cable into the connector shell,
Step 9. Tighten the lock nut.
INSTALLATION GUIDE 28
5-4 Terminating Power Supply Cables with Molex Connector (1/2)
Step 1. Remove 3.0 to 3.5 mm of insulation,
Step 2. Set the socket contact to the following position onto a hand
crimping tool,

HAND CRIMPING OUTSIDE DIAMETER SET
TOOL TYPE OF CABLE POSITION

57026-5000 1.5 to 1.8 1
1.8 to 2.2 2

57027-5000 2.3 to 2.6 1
2.6 to 3.1 2
INSTALLATION GUIDE 29
5-4 Terminating Power Supply Cables with Molex Connector (2/2)
Step 3. Squeeze the handle of the hand crimping tool, insert
cable into socket contact,
Step 4. Cable should fit, so insulation and bare wire are
arranged as shown,
Step 5. Squeeze the handle of the hand crimping tool until
ratchet is released,
Step 6. Insert socket contacts into the power connector till
they lock.
INSTALLATION GUIDE 30
6. Water Proof Protection
After cable connection, the following part should be wrapped by selfbonding tape for waterproof see following
figures.
INSTALLATION GUIDE 31
7. Antenna Orientation
Antenna Orientation
Flow Chart
INSTALLATION GUIDE 32
IF Cable Termination
1-First, Fit the Lock Nut, Washer
and Gasket on the Cable as
shown

Gasket
washer
Lock Nut
INSTALLATION GUIDE 33
2-Strip Back the cable sheath,
taking care not to damage the
braided shield.
Fit Clamp A
NESIC CAIRO
INSTALLATION GUIDE 34
3-Fold back the Braided shield,
Separating the strands of the braid.
Cut the
extra length,
to fit to
Clamp A
INSTALLATION GUIDE 35
4-Cut away the insulation from
the center conductor and fit
the clamp B.


Be sure not to cut or scratch
the conductor while
stripping the insulation
NESIC CAIRO
INSTALLATION GUIDE 36
5- Cut the center conductor to fit
the connector center contact
(~1.2cm).

6- Mount the center contact onto
the center conductor




7- Mount the Insulation onto the
center contact.
Taper the end of the center
conductor using a file
Insulation
INSTALLATION GUIDE 37
8-Insert the cable into the
connector shell

9- Tighten the Lock Nut.
Insure the good tighten
condition using the suitable
wrench

NESIC CAIRO
INSTALLATION GUIDE 38
10- Check the connector-cable
continuity suing multemeter.

11- Cover the outdoor connector
with rubber tape.





12- Cover the rubber tape with all
weather vinyl tape.








13- The connector is ready for use.
NESIC CAIRO
INSTALLATION GUIDE 39
CONNECTOR &POWER
CABLE
Power
Connector
Power
Cable
Socket Contact
INSTALLATION GUIDE 40
1-Remove 3.0 to 3.5 mm of Insulation


2- Set the socket contact to the following
position onto the hand crimping tool
1
Hand Crimping tool
(57026-5000)
Position ia. of Cable d Crimping Type
57026-5000 1.5 to 1.8 1
1.8 to 2.2 2
57027-5000 2.3 to 2.6 1
2.6 to 3.1 2
2
INSTALLATION GUIDE 41
3- Squeeze the handle of the hand crimping tool, insert cable into socket
contact



4- Cable should fit, so insulation and bare wire are arranged as shown,









5- Squeeze the handle of the hand crimping tool until ratchet is released.
INSTALLATION GUIDE 42






6- Insert socket contacts to power
connector till they locked and be sure it
is well fixed.

5-Squeeze the
handle of the hand
crimping tool until
ratchet Is released
(0 V)
(-48 V)
NESIC CAIRO
INSTALLATION GUIDE 43
The Connector is ready to use
NESIC CAIRO
INSTALLATION GUIDE 44
7-2 DC input Voltage value & Polarity
1-Check the DC input voltage in IDU is connected correctly Check the DC input voltage in IDU is
connected correctly and in the accepted range and in the accepted range Power requirement:
(+/- 20 to +/- 60) Or (+/-20 to +/- 72)
INSTALLATION GUIDE 45
POWER CABLE TERMINATION
INSTALLATION GUIDE 46
7-1 Visual Inspection
Visual Inspection purpose is to insure all installation and wiring work were done in
proper way and wiring work were done in proper way:-

1-Check the appearance and label Check the appearance and label

2-Check the ODU &Antenna frequency based on Check the ODU &Antenna
frequency based on frequency plan frequency plan

3-Check the fixing way of rack and equipment Check the fixing way of rack and
equipment

4-Check the cable connection and power Polarity Check the cable connection and
power Polarity
INSTALLATION GUIDE 47
7-3 IDU Start UP
1-Be sure the power cable and IF cable are connected in Proper way

2- Carefully Poll out the Power On / Off toggle switch and put in ON position.

3- To shutdown the IDU switch the toggle switch to Off To shutdown to Off Position
- NOTES:

1-Never switch it Off before at least 30 sec.
2-Never connect or disconnect the IF Cable while the equipment is powered On
3-Leave the equipment to warm up
7-4 IDU Settings and Testing ( Refer go Chapter 04 Operation Description).
INSTALLATION GUIDE 48
7-5 Antenna Orientation (1/4)
INSTALLATION GUIDE 49
7-5 Antenna Orientation (2/4)
INSTALLATION GUIDE 50
7-5 Antenna Orientation (3/4)
INSTALLATION GUIDE 51
7-5 Antenna Orientation (4/4)