Page 2
Upon completion of this course, you will be able to: Know application scenarios of DBS3900 Master the hardware structure of DBS3900 Master the functions of different modules Master the cables connection rules of DBS3900 Know networking and configuration examples
Page 3
Page 4
DBS3900 Abbreviations
WMPT WBBPa WRFU UBFA UEIU UELP UFLP UPEU WCDMA Main Processing and Transmission Unit WCDMA Baseband Process unit Type A WCDMA Radio Filter Unit Universal BBU Fan Unit Type A (2U) Universal Environment Interface unit Universal E1/T1 Lighting Protection unit Universal FE/GE Lighting Protection unit Universal Power and Environment Interface Unit
UTRP
RCU CPRI AISG TMA SRXU APM
Page 5
Page 6
DBS3900 Overview
DBS3900 is a distributed NodeB of forth generation NodeB.
DBS3900 system consists of:
TMA RF jumper
Feeder
Grounding cable
Power cable
BBU3900
RF jumper
Page 7
2G BTS RF Cable
Page 8
Shelter
Air-conditioner
BBU
BBU3900+RRU+APM
Page 9
Launch a new 3G indoor site, there is an equipment room with limited space.
RRU
Page 10
Baseband unit
+
BBU3900 SRXU RRU3804 RRU3801E
Page 11
BBU3900 supports 24 cells, with 1,536 UL CEs and 1,536 DL CEs. One RRU3804 supports the 4-carrier configuration. When the NodeB expands from 1x1 to 1x4 or from 3x1 to 3x4, no extra RRU is required. Characteristics of the DBS3900
Supports RRU cascading
Page 12
Supports high-speed packet access (HSPA) technology HSDPA allows the traffic at up to 28 Mbps for a single cell The peak uplink data rate of an HSUPA subscriber is up to 5.76 Mbit/s.
Page 13
Page 14
Chapter2 Hardware Introduction Section1 Section2 Section3 Section4 BBU Hardware RRU Hardware DBS3900 Cables Antenna and Feeder Subsystem
Page 15
Clock mode
Signaling Processing
Operation& Maintenance
Power mode
Demodulation
Power Control information
TO RRU
RNC
Codling
Modulation
Page 16
Baseband unit
Typical configuration
BBU3900 Module
Mandatory boards and modulesWMPT, WBBP, UBFA, and UPEU The optional boards are the UELP, UFLP, UTRP, and UEIU.
Page 17
WBBP
WBBP WBBP
UTRP
WMPT WMPT
Slot 0
Slot 1
Slot 2
Slot 3
Slot 4
Slot 5
Slot 6 available
Slot 7 available
available available
available available
available available
available
available
available available
Page 18
4E1:DB26
Board number
maximum is 2 for one BBU mandatory board working in active and standby mode
Providing OM functions Controlling other boards in the system and providing the reference clock Providing USB ports for automatic NodeB
upgraded
Providing transmission port for Iub interface Providing OM channels
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 19
Label RUN
Color Green
Status ON OFF
Description The board has power input, yet the board is faulty. The board has no power input.
1s ON, 1s OFF
0.125s ON, 0.125s OFF ALM Red ON OFF ACT Green ON OFF
Page 20
Color Green
Status ON OFF
Description The connections are functional. The connections are faulty. There is ongoing data transmission. There is no data transmission.
Yellow
Blinking OFF
Green
Yellow
ON
OFF Blinking OFF
Page 21
SW1 for setting the E1/T1 working mode SW2 for setting the protection ground for the E1.
Settings of SW1 Bit T1 Mode 120-ohm E1 Balanced Mode 75-ohm E1 Unbalanced Mode
1
2 3 4
ON
ON OFF OFF
OFF
OFF ON ON
ON
ON ON ON
Settings of SW2 Bit 120-ohm E1 Balanced Mode 75-ohm E1 Unbalance d Mode Description
1
2 3 4
OFF
OFF OFF OFF
ON
ON ON ON
Page 22
Providing the CPRI interface for communication between the BBU and the WRRU or WRFU Processing uplink and downlink baseband signals and support HSUPA and HSDPA function Supporting 1+1 backup of the CPRI interface According to the board chip processing capability, WBBP module include seven specifications. Current WBBP is the A version, called WBBPa.
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 23
OFF
1s ON, 1s OFF 0.125s ON/OFF ACT Green ON
OFF
ALM Red OFF ON OFF CPRI0 CPRI1 CPRI2 Red Green ON Blinking at 2 Hz Blinking at 0.5 Hz
Page 24
Board Type WBBPa WBBPb1 WBBPb2 WBBPb3 WBBPb4 Cell 3 cells 3 cells 3 cells 6 cells 6 cells
Downlink R99 CE 256 64 128 256 384 HSDPA Capacity 45 HS-PDSCH codes 45 HS-PDSCH codes 45 HS-PDSCH codes 90 HS-PDSCH codes 90 HS-PDSCH codes
Page 25
Controlling the fan speed Reporting the fan status to the WMPT
Page 26
-48V to +12V
+24V to +12V
Converting -48 V or +24 V DC power input to +12 V DC power that is supported by boards Reporting alarms related to input and output under voltage
Providing transmission ports for RS485 signals and 8 dry contact alarm signals
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 27
Label RUN
Color Green
Status ON OFF
Description The board is running properly. The board has no power input, or the board is faulty.
Socket and Port: The UPEU has one socket and four ports.
Label
PWR EXT-ALM1 EXT-ALM0 MON1
Quantity
1 1 1 1
Connector Type
3V3 RJ45 RJ45 RJ45
Function
DC power input Transmitting dry contact alarm signals Transmitting RS485 environment monitoring signals
MON0
RJ45
Page 28
The UTRP provides ports for eight E1s/T1s and implements transport such as IP and ATM between the BBU3900 and the RNC.
4 E1:DB26
Label RUN
Color Green
Status ON OFF 1s ON, 1s OFF 0.125s ON, 0.125s OFF 2s ON, 2s OFF
Description The board has power input, yet the board is faulty. The board has no power input or is faulty. The board is running properly. Software is being loaded to the board. The board is under test. The board is in active mode. The board is in standby mode. The board is running properly. The board is reporting alarms and is faulty.
ACT
Green
ON OFF
ALM
Red
OFF ON
Page 29
UTRP board should add sub board to provide the different interface type WD22UTRP is the main board name. The UTRP has three sub-boards in current version
UAEU: Eight ATM over E1s/T1s UIEU: Eight IP over E1s/T1s
Board
UTRP2 UTRP3 UTRP4 UTRP6 UTRP9
Port
Two universal FE/GE optical port Ports for eight channels of ATM over E1/T1 Ports for eight channels of IP over E1/T1 Port for one unchannelized STM-1/OC-3 Four universal FE/GE electrical ports
Page 30
maximum is 1
Connecting to an external monitoring device and transmitting RS485 signals to the WMPT
Page 31
UELP
protection unit is an optional module of the BTS3900 cabinet (-48 V) or the power distribution cabinet.
The UFLP and the UELP
Page 32
The UELP can be optionally installed in the SLPU or the BBU. Each UELP supports the surge protection of 4-way E1/T1 signals. DB25
DB26
E1 Connection:
E1 E1
Indoor DDF
Page 33
DIP Switch S1
Description Used for the 75 unbalanced mode Used for other modes except the 75 unbalanced mode
Page 34
IP Cable Connection.
Transmission Equipment LAN switch or Router
Page 35
Chapter2 Hardware Introduction Section1 Section2 Section3 Section4 BBU Hardware RRU Hardware DBS3900 Cables Antenna and Feeder Subsystem
Page 36
PA
Interface module
MTRX
RX signaling Processing unit Extension interface LNA LNA Power module
BBU
CPRI
RX3 RX signaling Processing unit SRXU LNA LNA RX4 Antenna system
Page 37
RRU3804 Characteristics
Support 12dB, 24dB gain TMA RTWP statistic and report Standing wave detect and report Support ASIG (Antenna Interface Standards Group) 2.0 Receiver reference sensitivity typical value -125.5dBm RRU3804 connected to the SRXU supports 4-way RX diversity
Number of carrier
1 2 3 4
Page 38
14(RRU3804) / 12(RRU3801E)
NOTES:
The RRU3801E appearance (Panel and Ports) is the same with the RRU3804;
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 39
Alarm port
LEDs on RRU3804/RRU3801E-I
Label RUN Color Green Status ON OFF 1s on, 1s off 0.5s on, 0.5s off ALM Red ON OFF TX_ACT Green ON OFF Description The module has power input, yet the module is faulty The module has no power input or is reporting alarms The module is operational Software is being loaded to the module The module is reporting alarms (excluding VSWRrelated alarms The module is operational The module is running No specific meaning
Page 41
LEDs on RRU3804/RRU3801E--II
Label VSWR Color Red Status ON OFF CPRI_W Red/gr een ON (green) ON (red) 0.5s ON, 0.5s OFF (red) Description VSWR-related alarms are reported No VSWP-related alarm is reported The CPRI link is normal The optical module receives local alarms related to LOS The CPRI is out of lock
OFF
CPRI_E Red/gr een ON (green) ON (red) 0.5s ON, 0.5s OFF (red) OFF
Page 42
The weight of the SRXU :6KG -48V DC 30W Allowed voltage range -36 V DC to -57 V DC
Page 43
Socket for power supply Power Input From RRU Interconnection port between combined cabinets Port for RET antenna
Grounding bolt
Page 44
RRU Configurations
The RRU is divided into two types according to output power and carries:
40 W RRU3801E, 40W output power on the top of cabinet 60 W RRU3804, 60W output power on the top of cabinet
RRU type
RRU3804 RRU3801E RRU3804 RRU3801E RRU3804 RRU3804 RRU3801E RRU3801C RRU3801C Frequency band UMTS2100 UMTS2100 UMTS1900 UMTS1900 UMTS1.7/2.1G UMTS850 UMTS850 UMTS1800 UMTS900
Receiving Band
1920MHz1980MHz 1920MHz1980MHz 1850MHz1910MHz 1850MHz1910MHz 1710MHz1755 MHz 824MHz849MHz 824MHz849MHz 1710MHz1785MHz 880MHz915 MHz
Transmitting Band
2110MHz2170MHz 2110MHz2170MHz 1930MHz1990MHz 1930MHz1990MHz 2110 MHz2155 MHz 869MHz894MHz 869MHz894MHz 1805MHz1880MHz 925MHz960MHz
Carriers
4 2 4 2 4 4 2 2 2
Page 45
Chapter2 Hardware Introduction Section1 Section2 Section3 Section4 BBU Hardware RRU Hardware DBS3900 Cables Antenna and Feeder Subsystem
Page 46
Page 47
at the other end. Appropriate terminals are added to the bare end on site.
1) 3V3 connecter
2) OT terminals
Page 48
E1 Cable
FE Cable
Page 49
Installation Position
Page 50
the RET/PWR_SRXU port at the bottom of the RRU, and the other end is connected to the PWR_SRXU socket at the bottom of the SRXU.
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved Page 51
The CPRI optical cable is a multi-mode 2-wire cable with DLC connectors at both ends BBU and RRU CPRI hardware connection is same between RRU3801E and RRU3804
BBU3900
1) DLC connector
3) Fiber tail
Page 52
The five-meter-long AISG multi-wire cable connects the RRU3804/SRXU to the Remote Control Unit (RCU). If both RRU3804 and SRXU are installed, the AISG multi-wire cable only connects the SRXU and the RCU. This cable is optional
One end of the AISG multi-wire cable is a waterproof DB9 connector, and
Page 53
When the distance between the RCU and the RRU3804/SRXU is longer than 5 m, the AISG multi-wire cable is not long enough to cover the distance and the AISG extension cable is used. The AISG extension cable is 15 m long
One end of the AISG extension cable is a standard AISG male connector,
Page 54
Interconnect jumper: transmits RF signals between two RRU3804s/SRXUs. The interconnect jumper is optional, depending on the site configuration. The interconnect jumper is 2 m long, and both ends have 2W2 connectors The 2W2 connectors at the two ends of the interconnect jumper are linked to the ports labeled RX_IN/OUT on two RRU3804s/SRXUs respectively
Waterproofed Joints
Page 55
Page 56
BBU3900
Page 57
BBU3900
Page 58
Optical cable
BBU3900
Power cable
Page 59
Optical cable
Page 60
Chapter2 Hardware Introduction Section1 Section2 Section3 Section4 BBU Hardware RRU Hardware DBS3900 Cables Antenna and Feeder Subsystem
Page 61
+ Roof station
(1) Directional antenna (4) Outdoor cable rack (7) Outdoor grounding bar (2) Pole (3) Outdoor jumper (6) Feeder grounding kit (9) Feeder window
(5) Feeder clip (8) To outdoor lightning protection ground (11) indoor jumper
(13) Feeder
Page 62
+ Tower Station
(1) Lightning rod (4) Directional antenna (2) Pole (5) Waterproof curve (8) Outdoor cable rack (3) TMA (6) Feeder grounding clip
(7) Feeder
Page 63
Page 64
Page 65
BBU Networking
BBUs and RNC can form multiple
BBU
BBU RNC BBU
Page 66
RRU Networking
BBUs and RRUs can form multiple networking modes such as star,
When using the 1.25 G optical module, cascading levels 4 When using the 2.5 G optical module, cascading levels 8
Page 67
Typical Configuration11
Applied to wide areas and indoor circumstances
RRU
BBU3900
Page 68
Typical Configuration21
Applied to long stretched areas
RRU
BBU3900
Page 69
Typical Configuration31/32
Applied to cities or other high capacity areas
RRU
cities
RRU
RRU
BBU3900
Page 70
Typical Configuration
Number of WBBPs 1 2 3 4
Page 71
Thank You