Professional Documents
Culture Documents
A load combination combines different types of loads depending on the probability of occurrence of these loads, considering their expected intensity in the combination compared with the maximum load intensity.
1
The factors of safety are also included in the LRFD load combinations and hence the output of the expressions is a design load.
The alphabets used in the combinations mean different types of nominal service loads and the numerical values with them are all the load factors. 2
When intermediate floors have full live loads, any type of roof load may be considered equal to half of its normal service load intensity. Similarly, in case of maximum intensity wind storm, live load may be half.
The last combination, given afterwards, is very important for uplift of structure or reversal of forces.
The wind load on roof is upwards in majority of the cases and if the downward gravity load is less, the structure may be blown up or sagging bending may change into hogging bending. A list of most commonly combinations are as under: used
4
or R)
L Lr W S E R H
F
T
dead load live load roof live load wind load snow load earthquake load rainwater or ice load load due to lateral earth pressure, ground water pressure or pressure of bulk materials load due to fluids with well defined pressures and max heights. self-retaining force
6
5.
6.
D + H +F + (W or 0.7E)
D + H +F + 0.75(W or 0.7E) + 0.75L + 0.75(Lr or S or R)
7.
8.
0.6D +W +H
0.6D + 0.7E + H
8
When the loads S, R, H, F, E and T are taken equal to zero and wind loads are taken from the previous codes, the load combinations are reduced to the following from:
9
LRFD
1.
2.
1.4D
1.2D + 1.6L + 0.5Lr
3.
4.
5.
0.9D + 1.3W
10
ASD
1. 2. 3. 4. 5.
6.
7.
The intensity of live load may be reduced if the contributory area for the live load exceeds certain limit.
It is due to the fact that, under these circumstances, all the area may not be subjected to the full load.
12
All uniform live loads, except the roof loads (for which separate provisions are given in ASCE-07), may be reduced as follows:
4 . 57 L L 0.25 K LL AT
Where
Lo AT KLL = the unreduced live load = tributary area in m2 = live load element factor
13
Interior columns and exterior columns without cantilever slabs. Edge columns with cantilever slabs.
Corner columns with cantilever slabs, edge beams without cantilever slabs and interior beams. All other members including slabs.
KLL = 4
b
c
KLL = 3
KLL = 2
KLL = 1
14
TYPES OF STRUCTURAL STEEL Steels are divided into four categories depending on the carbon percentages (C) as following:
1. 2.
3.
4.
C = 0.30 0.59%
C = 0.60 1.70% 15
E-Value of steel = 185 GPa to 230 GPa (Average 200 GPa) Unit weight = 7850 kg/m3 = 77 kN/m3 = 7.85 g/cc For comparison, the unit weight of concrete is 23.6 kN/m3.
16
Most of the structural steel falls into the mild carbon steel or simply mild steel (MS) category. Hot rolled structural shapes may be made to conform to A36M, A529M, A572M, A588M, A709M, A913M and A992M.
17
Sheets are manufactured according to the standards ASTM A606, A1011MSS, HSLAS and HSLAS-F. Bolts are made according to ASTM standards A307, A325M, A449, A40M and F1852.
18
Most commonly used structural steel is A36M having the following properties:
Fy = 250 MPa
Fu = 400 MPa E = 200 GPa
19
Weld Electrode And Filler Material Weld electrodes are classified as E60, E70, E80, E100 and E110.
HOT ROLLED STRUCTURAL SHAPES These are the steel cross-sectional shapes that are hot rolled in the mills. Some of these shapes are shown in next slides, whereas, the steel bars, plates and hollow sections are reproduced in slides next to the above slides. An HP h x w is a bearing pile section, which is approximately h mm deep weighing w kgs/m.
21
HOT ROLLED STRUCTURAL SHAPES Bearing piles are made with the regular W rolls but with thicker web to provide better resistance to the impact of pile driving. HSS are hollow structural sections that are prismatic square, rectangular or round products of a pipe or tubing.
22
23
HOT ROLLED STRUCTURAL SHAPES Every hot rolled shape has its unique standard designation, which not only tells about the type of cross-sectional shape but also about its size. The details about some of the common hot rolled shapes are given in the next slides. 24
Slope 0
W-Section
25
16.7% Slope
S-Section
26
Angle-Section
27
16.7% Slope
Channel-Section
28
Tee-Section
29
HP-Section
30
Pipe Section
31
Structural Tubing
32
Bars
33
Plates
34
1. W-Shapes The letter W stands for an I-shape with wide flange. The cross-section is doubly symmetric in the form of the letter I. The width / depth ratio varies from about 0.3 to 1.0.
The US Customary designation W 16 x 40 means that the nominal depth of the section is 16 in and the weight per unit length of the section is 40 lbs/ft.
35
1. W-Shapes Nominal height is the rounded off height to be used for common use.
Actual depth of the section may be in decimals and somewhat different from this depth.
36
Less or no slope
Flange
Web
The equivalent SI designation W410 x 60 means that the Wsection has a nominal depth of 410 mm and a weight of 60 kgf/m.
37
This kilogram-force weight per unit length may be converted in kN/m by multiplying it with the factor 9.81/1000.
38
2. S-Shapes
16.7% Slope
2. S-Shapes
16.7 % Slope
the section is S-shape having nominal depth of 510 mm and weight of 112 kgf/m. 40
3. M-Shapes
o Miscellaneous I-shapes.
o Doubly
o Relatively
shape section having nominal depth of 310 mm and weight of 17.6 kgf/m. 42
16.7 % Slope
o Channel
shapes proportions.
with
standard
43
16.7 % Slope
or
44
16.7 % Slope
o A C150 x 19.3 is a standard channel
shapes.
o Previously called Shipbuilding or
Miscellaneous Channels.
46
6. L-Shapes or Angle Sections The various types of angle sections are shown in Figure and their salient features are given below:
a
6. L-Shapes or Angle Sections The various types of angle sections are shown in Figure and their salient features are given below:
a
6. L-Shapes or Angle Sections The various types of angle sections are shown in Figure and their salient features are given below:
a
angle sections.
49
or arms. o L89 x 76 x 12.7 is an unequal leg angle with longer leg dimension of 89mm and shorter leg dimension of 76mm with a leg thickness of 12.7mm.
50
o Double
angle sections are combination of two angles with longer or shorter sides close to each other. by 2Ls.
51
angles L89 x 76 x 12.7 placed side by side in one of the ways shown in the figure.
52
7. T-Shapes
7. T-Shapes
a nominal depth of 205mm and a weight of 30kgf/m and is obtained by splitting the W410 x 60 section.
54
COLD FORMED SHAPES These sections are formed from thin high strength steel alloy plates under normal temperature. Some of the common shapes of these sections are drawn in Figure:
55
Channels
56
Zees
57
58
Angle
59
Hat Sections
60
BUILT-UP SECTIONS Sections made by combining two or more standard hot rolled sections, joined together at intervals with the help of direct welding, stay plates or lacing, are called built-up sections. Examples are four angles section, double angle section and double channel section shown in Figure.
61
BUILT-UP SECTIONS However, double angle section is sometimes excluded from built-up section category and is considered as a regular hot rolled member because of difference of its behavior from other built-up sections.
62
Double Angle
64
Thanks Questions????