Steam and Water Sampling


Why sample? Monitor/adjust water chemistry to:
Maximize heat transfer efficiency Maximize time between chemical cleanings Maximize boiler life and turbine life Minimize operating & maintenance costs

Sentry Equipment Corp


Sampling Solutions Specialty Heat Exchangers

Typical Plant Diagram

Sentry Equipment Corp


Sampling Solutions Specialty Heat Exchangers

Typical Plant Diagram

Sentry Equipment Corp


Sampling Solutions Specialty Heat Exchangers

Important Sample Conditioning Parameters The Primary objective of any sampling system is to transport and condition a sample without altering the characteristics of interest. The system parameters which need to be controlled are velocity, pressure and temperature.
Source: EPRI CS-5164, April 1987

Sentry Equipment Corp


Sampling Solutions Specialty Heat Exchangers

Sample Point Selection, CC System


1. 2. 3. 4. 5. 6. 7. Gas Turbine Generators Steam Turbine Main Steam SiO2, Na, CC HRSG Boiler Drum - pH, SC, PO4, SiO2, Na, Chloride Condenser pH, SC, CC, Na, SiO2, DO Feed water SC, CC, Na, pH, SiO2 Boiler Feed Pump

Not shown:
Deaerator DO, pH, SC, CC
Sentry Equipment Corp
Sampling Solutions Specialty Heat Exchangers

Economizer pH, CC

Sample Point Selection


Based on: System design Subject constituents Chemical treatment System specific problems

Sentry Equipment Corp


Sampling Solutions Specialty Heat Exchangers

Sample Velocity
Velocity should be 5-6 ft/sec (1.8 m/sec) to maintain equilibrium of ionic and particulate components Ideally, sample lines in sample system should be 1/4 (6.35mm) tube; flow rate at of about 1200 cc/min and velocity at 6 fps (1.8 m/s).

Flow rate of 3300 cc/min in a 3/8 (9.5mm) tube with .065 (1.65mm) wall is 6 fps
Sentry Equipment Corp
Sampling Solutions Specialty Heat Exchangers

Erosion/Deposition and Equilibrium

Sentry Equipment Corp


Sampling Solutions Specialty Heat Exchangers

Velocity vs- Deposition

Sentry Equipment Corp


Sampling Solutions Specialty Heat Exchangers

Deposition vs- Time

Sentry Equipment Corp


Sampling Solutions Specialty Heat Exchangers

Sample Lag Time


Tube Size 1/4x.042 wall

Flow rate cc/min 500 1200

Velocity Ft/sec Lag Time/1000 2.5 6.5 min 6.0 2.8 min
0.9 2.2 3.0 6.0 18.7 min 7.6 min 5.6 min 2.8 min

3/8x.065wall

500 1200 1666 Theoretically correct > 3300 But not practical
1/2x.125 wall essentially equal to 3/8x.065 wall 6.0 ft/sec is approximately 1.8 m/sec

Sentry Equipment Corp


Sampling Solutions Specialty Heat Exchangers

P&ID Complete System

Sentry Equipment Corp


Sampling Solutions Specialty Heat Exchangers

Sentry Equipment Corp


Sampling Solutions Specialty Heat Exchangers

Temperature Control Primary Coolers


Primary sample cooler approach temperature: 5 F (2.8 C) of coolant temperature Corrosion resistant tubing (18% Cr, 8% Ni), 316 SS, internal baffles Coil tubing to meet velocity requirements (1/4, 3/8 O.D.) (6.35mm, 9.5mm)
Sentry Equipment Corp
Sampling Solutions Specialty Heat Exchangers

Sample Coolers

Sentry Equipment Corp


Sampling Solutions Specialty Heat Exchangers

Sample Coolers

Sentry Equipment Corp


Sampling Solutions Specialty Heat Exchangers

Sample Coolers
High Efficiency, Counter Flow Design All Stainless Steel Construction Single Gasket Design 100% Hydrostatic Testing, Tube and Shell Variety of Shell and Tube Materials Available

Sentry Equipment Corp


Sampling Solutions Specialty Heat Exchangers

Sample Coolers - Materials


Standard Tubeside Materials:
316/316L Stainless Steel Alloy 625 (Inconel 625)

Standard Shellside Materials:


Sentry Equipment Corp


Sampling Solutions Specialty Heat Exchangers

316/316L Stainless Steel 304 Stainless Steel 90/10 CuproNickel

Special Sample Coolers


Special sample coolers Cooling water with elevated chlorides and DO such as cooling tower water or potable water sources High temperature samples Use Inconel 625 coils, CuNi shells

Sentry Equipment Corp


Sampling Solutions Specialty Heat Exchangers

Sample Coolers - Materials


Optional Tubeside Materials, short coil only:
Alloy C-276 (Hastelloy) Alloy 200 (Nickel) Alloy 400 (Monel) Titanium Zirconium 310SS

Optional Shellside Materials:

316/316L SS

Additional materials may be possible. Orbitally welded Sentry Equipment Corp long coils currently available in Zirconium
Sampling Solutions Specialty Heat Exchangers

Sample Coolers

Sentry Equipment Corp


Sampling Solutions Specialty Heat Exchangers

Competitive Products
Waters Equipment USA Dr Thedig - Germany Forbes Marshall India Lowe U.K. DKK Japan Nikkiso Japan/Taiwan Eurosysteme Watcom Westhoff

Sentry Equipment Corp


Sampling Solutions Specialty Heat Exchangers

Competitive Products
Analyzer manufacturers ABB Yokagawa Emerson Swan Others local

Sentry Equipment Corp


Sampling Solutions Specialty Heat Exchangers

Competitive Products
May not offer performance calculations Carbon steel shells Thin wall shells (drawn) May not offer dual baffle Tie-rod designs May offer dual-tube units which dont work for ASTM recommended flows

Sentry Equipment Corp


Sampling Solutions Specialty Heat Exchangers

Important Sample Conditioning Parameters Secondary Cooling


Secondary cooling Recommended to control sample temperature to 77 F +/- 1 F (25 C +/- .5 C) Analyzer temperature correction algorithms should be evaluated for: Suitability given the expected sample matrix Sample temperature range Sensitivity Potential correction factor error
Sentry Equipment Corp
Sampling Solutions Specialty Heat Exchangers

Important Sample Conditioning Parameters Secondary Cooling


Isothermal Bath Coils in chilled water bath Chiller with hot gas bypass Thermal bypass valves Must have good mixing in bath Bypass valves can be problematic

Sentry Equipment Corp


Sampling Solutions Specialty Heat Exchangers

Important Sample Conditioning Parameters Secondary Cooling


Individual sample coolers Individual, high efficiency coolers for each sample stream Chilled water supply with hot gas bypass 75-76 F +/- 1 F (23.9 24.4 C) Hot gas bypass can add heat into system if samples are sub cooled
Sentry Equipment Corp
Sampling Solutions Specialty Heat Exchangers

Important Sample Conditioning Parameters Secondary Cooling


Field Study 19 Fossil and Nuclear plants 11 isothermal bath systems 8 individual cooler systems Isothermal baths averaged 77 F +/- 5 F ( 25 C +/- 2.7 C) Max deviation 28 F (15.6 C) Individual secondary coolers averaged 77 F +/2 F ( 25 C +/- 1 C) Max deviation 5 F (2.7 C)
Sentry Equipment Corp
Sampling Solutions Specialty Heat Exchangers

Sentry Equipment Corp


Sampling Solutions Specialty Heat Exchangers

Important Sample Conditioning Parameters


Pressure Reduction All Wetted Parts Stainless Steel Needle valves for 500 psig and less Rod-in-tube for pressures greater than 500 psig Drag valves and capillary tubes are prone to plugging Adjustable rod-in-tube preferable Cleanable in place Adjust to proper flow
Sentry Equipment Corp
Sampling Solutions Specialty Heat Exchangers

Pressure Reduction
VREL (Variable Pressure Reducing Element)

Sentry Equipment Corp


Sampling Solutions Specialty Heat Exchangers

VREL

Sentry Equipment Corp


Sampling Solutions Specialty Heat Exchangers

VREL

Sentry Equipment Corp


Sampling Solutions Specialty Heat Exchangers

Competitive Products
Look alike or similar rod-in-tube designs may or may not operate well Capillary tubes - plug Drag valves plug - expensive Multiple needle valves wear same price as VREL

Sentry Equipment Corp


Sampling Solutions Specialty Heat Exchangers

Sentry Equipment Corp


Sampling Solutions Specialty Heat Exchangers

Important Sample Conditioning Parameters


Flow Control EPRI/ASTM recommends a Rod-in-tube pressure reducing device and backpressure valve combination Constant sample velocity/flow Reduced possibility of crud bursts Constant flow to on-line analyzers for repeatable analysis results BP/RV acts as a shock absorber
Sentry Equipment Corp
Sampling Solutions Specialty Heat Exchangers

Back Pressure Regulator/Relief Valve

Sentry Equipment Corp


Sampling Solutions Specialty Heat Exchangers

BP/RV
Assures Constant Pressure/Flow to Analyzers Protects System From Over Pressurization Large Orifice Wont Plug or Stick Constant Pressure Over Wide Flow Range Regulates to 20 psi (standard) Metallic Wetted Parts Stainless Steel Elastomer Viton Seat PEEK Optional pressure settings: 5 psig (0.3 barg), 7 psig (0.5
barg), 12 psig (0.8 barg), 28 psig (1.9 barg), 42 psig (2.9 barg), 60 psig (4.1 barg)
Sentry Equipment Corp
Sampling Solutions Specialty Heat Exchangers

BP/RV

Sentry Equipment Corp


Sampling Solutions Specialty Heat Exchangers

Back Pressure Regulator/Relief Valve

Sentry Equipment Corp


Sampling Solutions Specialty Heat Exchangers

Competitive Products
Tescom Go Coniflo Not designed specifically for the application

Sentry Equipment Corp


Sampling Solutions Specialty Heat Exchangers

Sentry Equipment Corp


Sampling Solutions Specialty Heat Exchangers

TSV
(Thermal Shut Off Valve)

Sentry Equipment Corp


Sampling Solutions Specialty Heat Exchangers

Thermal Shut Off Valve (TSV)


Protects analyzer cells Protects operators Mechanically Actuated, Automatic Shut-Off for Thermal Protection Visual Trip Indication Optional Switch for Remote Indication Requires Manual Reset Latching Design No Pneumatic or Electrical Power Required

Sentry Equipment Corp


Sampling Solutions Specialty Heat Exchangers

Competitive Products
Wax valves automatically reset or are one use Sensor, controller and solenoid valve expensive problematic Bi-metal, mechanical or electro-mechanical trip point is not accurate, prone to failure

Sentry Equipment Corp


Sampling Solutions Specialty Heat Exchangers

Thermal Shut Off Valve (TSV)


Standard Wetted Materials 316 Stainlesss Steel, Viton, PEEK Optional Elastomer Kalrez Standard Temperature Set Point = 120 F (49 C) Optional Temperature Set Points = 104 F (40 C), 140 F (60 C), 160 F (71 C), 153 F (67 C), 194 F (90 C), 203 F (95 C), 210 F (99 C)

Sentry Equipment Corp


Sampling Solutions Specialty Heat Exchangers

Sentry Equipment Corp


Sampling Solutions Specialty Heat Exchangers

Cation Resin Column

Sentry Equipment Corp


Sampling Solutions Specialty Heat Exchangers

Cation Resin Column


Ion exchange resin uses porous beads that have a Hydrogen ion that can be exchanged for a cation. R = the resin and H = hydrogen ion 2R-H +Ca+2 <=> R2-Ca +2H+ The Resin column acts somewhat like a filter Reduces the masking effect of ammonia Proper length dia. Ratio for good ion exchange Prevents channeling Refillable

Sentry Equipment Corp


Sampling Solutions Specialty Heat Exchangers

Cation Resin Column


Major Cations in water Ca+2 Mg+2 Na+ Fe+2 Cr+6 Ni+3 Cu+2 Zn+2 NH4+
Sentry Equipment Corp
Sampling Solutions Specialty Heat Exchangers

Competitive Products
Many, varied Resin is mostly the same but length to diameter ratio is key to proper ion exchange A larger column may offer more resin but poorer ion exchange Tubes are usually thinner, poor quality

Sentry Equipment Corp


Sampling Solutions Specialty Heat Exchangers

ASTM Standards
ASTM 3370 Standard Practices for sampling water from
closed conduits

ASTM 5540 - Standard Practices for flow control and


temperature control for On-Line water sampling and analysis

Shortcut to ASTMD5540.pdf ASTM 1066 Standard practices for sampling steam Note: ASTM 1192 Similar to D5540 - suspended
Sentry Equipment Corp
Sampling Solutions Specialty Heat Exchangers

Conclusion
A properly designed sample system transports and conditions samples from the point of extraction to analysis points without altering the characteristics of interest

Sentry Equipment Corp


Sampling Solutions Specialty Heat Exchangers

End Of Sampling Components

Sentry Equipment Corp


Sampling Solutions Specialty Heat Exchangers

Sample Line Fouling Solutions

Traditional sintered element filter, low temperature Strainer, high pressure and temperature Sentry Equipment Corp
Sampling Solutions Specialty Heat Exchangers

Sample Line Fouling Solutions


Sludge trap Designed to drop out particles rather than trap them and hold them in the flow stream. Installed upstream of primary sample cooler Usually limited to boiler drum or similar samples Requires periodic flush to drain and piping to safe location (HP header, blow down tank)