You are on page 1of 28

Optical engineering Dep.

System Components Installation and key point Debugging

Page 2

System Components

Outdoor Unit

Antenna Unit

Radio Cable

Indoor Unit

Page 3

Mount bracket String

Feed source

Parabolic reflec

Diameter (m): 0.30.61.21.5 1.8 2.02.53.2 3.7

Page 4

ODU

Flexibl e twist

Mount bracket

Page 5

PASOLINK

IDU

ODU
Antenna(0.3m)
Page 6

Page 7

Page 8

7 8

1. IF connector (to ODU) 2. 2Mbps interface (CH 9 to CH 16): impedance selector switch (75 or 120 ohms) 3. LAN Interface for main traffic: Port 1 and Port 2 (Optional) 4. WS/LAN: optional port for Wayside In/Out or 10BaseT 5. NMS LAN: for PNMS with LAN interface 6. Engineers Orderwire (EOW): receptacle for EOW headset 7. CALL: call buzzer for calling the opposite site of the transmission path 8. RESET: CPU reset switch for IDU

Page 9

10

11

12

13

9. LED:

PWR : that the power switch is on (Green)

MAINT: for the purpose of maintenance (Yellow)


ODU : that the ODU alarms occur (Red) IDU : that the IDU alarms occur (Red) 10. FG : connecting Frame Ground terminal

11. ESD: Connecting terminal for Electro Static Discharge


12. 2Mbps interface (CH 1 to CH 8) ): impedance selector switch (75 or 120 ohms) 13. ALM/AUX ALM: connector for parallel alarms (relay contact) connector for Data Input / Data Output
Page 10

14
14. OW / DSC / ASC (1) Order wire (2) Digital and Analog (VF) service channel

15

16

17

18

19

15. NMS / RA: for PNMS or remote access Local Craft Terminal (None PM Card)

16. LA Port: connector to PC for local access Local Craft Terminal or PNMT 17. Fuse: for primary DC line (be inserted in each plus and minus line)
18. 20SW : power switch

19. DC IN: connector for DC power in.


Page 11

Rear Side

Front Side

IF connector to IDU

RX LEV MON

RF interface to Antenna( PBR220)

Page 12

Page 13

Page 14

Page 15

PASOLINK+ IDU

1+1 System

Page 16

PASOLINK+ IDU Interface

OW: 1CH DSC: 2CH(64k/V11) ASC: 2CH(SDH) or 1CH(PDH) RS232C IF IN/OUT EXT PNMT LCT OW

6 Input 4 or O Output

IDU-IDU IDU-ODU ODU-ODU LEDs


MAINT ODU IDU PWR

7 or 11 Output House R keeping SW

EOW

ASC/DSC

ALM Out

CPU Reset

FUSE

FUSE

PS

NE1 NE2 LAN

V11 (PNMS)

WS(option)

INTFC 150(E/OPT) Nx2MB(75/120ohm)

FUSE

DC IN PWR SW

RS422(Sync/Async) or RS485
10Base-T

RS422 (Async)

WS(option) E1/T1/10Base Except STM-1/128Q


Page 17

PASOLINK+ IDU Interface


1

10

11

12

13

14

15

16

17

24

23

22

21

20

19

18

1. IF connector (to ODU) 2. PNMT : Connect to PC for NMS 3. LCT : Connect to PC for Local Craft Terminal 4. EOW1 : Connect between IDUs for order wire 5. EOW2 : Connect between IDUs for order wire 6. NE1 : Connect between IDUs for NMS network 7. NE2 : Connect between IDUs for NMS network 8. LAN : Connect between IDUs for NMS network with LAN network 9. V11 : Connect between IDUs for NMS network with V.11 network 10. SC IN/OUT : Connector for Service Channel 11. ALM connector for parallel alarms (relay contact : Form-C) 12. ALM/AUX : Connector for Data Input/Data Output for house keeping
Page 18

13. R SW : Selector switch for switching b.w. previous firmware and new download firmware 14. EOW : Receptacle for headset 15. CALL : Call buzzer for calling opposite site 16. RESET : CPU reset switch for IDU 17. LEDs : MAINT : IDU maintenance condition ODU : ODU alarms IDU : IDU alarms PWR : Power switch on 18. DC IN : Connector for DC power in 19. SW : Power switch 20. Fuse : Fuses for primary DC line 21. Interface Card : STM-1 optical/STM-1 electrical, Nx2MB(G.703) 22. WS IN/OUT or 10Base-T interface card : Select card as an option, wayside(2.048Mbps), 10 Base-T or blanc panel 23. ESD : Connecting terminal for Electro Static Discharge 24. FG : Frame Ground Terminal

Page 19

Gasket cant be lost!

Water-proof
There must be a gasket at the meeting place of the ODU and the antenna, or the meeting place of the ODU and the flexible twist. Smear the water-proof glue at the meeting place then wrap the water-proof tape and the then adhesive plaster at the outmost.
Be lack of water-proof and plaster!

Page 20

The waveguide ports must be identical! Dont be cross! The polarization orientation must be identical in one hop!

Page 21

Water-proof

Ground line must be connected!

Cable ought to superfluous.

Page 22

Cables ground line must be connected!

Page 23

There must be two nuts fixed!

This is unqualified!

Page 24

High site and Low site are forbidden in one station!

Page 25

Two terminals ought to be open! The adjusting line will be connected ODUs MON port with multimeter. Adjust multimeter to DVC 10 volt position. The multimeters display is bigger, the Rx power (Rx voltage) is better! During adjusting, one terminal is carrying on, another terminal must be quiet!

Rx LEV MON

Special adjusting line

Page 26

During the adjusting course, two cases are wrong: one terminals side-lobe meet another terminals side-lobe; one terminals side-lobe meet another terminals main-lobe! The only right case is that: one terminals main-lobe meet another terminals main-lobe!

wrong

wrong

right

Page 27

Rx power

Antenna moving orientation

The multimeter displaying

Page 28