National Building Code PD 1096

Notes on required measurements. http://arkireviewph.multiply.com arkireviewph@gmail.com

2.70m
maximum height of a combustible stand

0.85m
maximum spacing for seats in a chair type measurement from back to back

1:8
maximum line of travel to an exit of an aisle

0.84m
in standard seating, the minimum spacing of rows from back to back

0.45m
minimum width of any seat

1.30sq.m.
minimum area of a double acting door view panel

0.70m
minimum clear width of an exit doorway

1.20m
maximum width of an exit door leaf

1.10m
minimum width of an exit corridor

10

2
minimum number of exit for floors above the first storey having an occupant load of more than ten.

11

3
minimum number of exit for occupant load 599-999

12

0.30m
minimum downward projection of a draft curtain

13

2.50sq.m
maximum area of an attic made of combustible materials

14

1.80m
maximum center to center spacing of a draft sprinkler

15

7.50sq.m.
maximum area of an attic made of incombustible materials

16

GA 18
standard gauge for metal hood in barbeques

17

300mm / 0.30m
minimum height of siamese connection above grade

18

300mm / 0.30m
standard maximum distance of standpipe from an opening in a stairway

19

200mm / 0.20m
minimum wall thickness of a fireplace

20

2
minimum number of exit for a projection room

21

600mm / 0.60m
minimum extension of a chimney above roof

22

2 / 50mm
minimum space between walls of a masonry chimney above the roof

23

12mm / 0.12m
minimum glass thickness used for floors

24

400mm / 0.40m
maximum distance of one row of seat to the next

25

3
minimum number of exits for stand within a building serving an occupant load of 300

26

0.90m
minimum height of a guardrail located in front of the grandstand

27

0.28m
minimum width of a run in a standard stair

28

0.75m
minimum spacing for seats with backrests measured from back to back

29

0.60m
minimum spacing for seats without backrest measured from back to back

30

10.70 lux
minimum intensity for exit sign lights

31

1.10m
minimum width of side aisles

32

300mm / 0.30m
minimum increase in width of aisles for every linear meter

33

800mm / 0.80m
minimum width of an aisle serving only one side

34

50% of lot area


open space requirement for an interior lot

35

10% of lot area


open space requirement for a corner lot or through lot

36

inner court
bounded on all sides or around its periphery by building lines

37

750mm / 0.75m
minimum stair width for a residence

38

1.20sq.m.
standard minimum area of a toilet

39

1.50m
minimum dimension of a kitchen

40

1.00sq.m
minimum area for vent shafts

41

3.00cu.m
air space requirement per person in a school room

42

14.00cu.m
air space requirement per person in a habitable room

43

300sq.mm / 0.30sq.m
minimum area of a duct opening

44

300mm / 0.30m
maximum projection beyond the property line of a footing along the national road

45

2.40m
minimum depth of a footing projection beyond the property line along a national road

46

3.00m
minimum clearance of a canopy or marquee from a sidewalk

47

0.90m
minimum stair width for an occupant load that is less than 50

48

1.20m
minimum width of a temporary walkway

49

3.00m
minimum clearance of an arcade above the sidewalk

50

setback
the vacant space left between the building and the lot lines which is less than 2.00m in width

51

2.00m
minimum dimension of a court

52

1.20m
minimum width of passageway connecting a street to a court

53

12.00cu.m
standard air space requirement per person for factories

54

1.80m
minimum head clearance for a mezzanine

55

0.30cu.m
air supply per person per minute for auditoriums

56

10% of floor area


minimum total area of a window or an opening for a room without artificial ventilation

57

0.60m
minimum dimension for a vent shaft

58

300mm / 0.30m
minimum horizontal clearance of the curb line to the outermost edge of the marquee

59

2.40m
minimum clearance of the lowest portion of an awning to the ground

60

2.40m
minimum height of a construction fence

61

600kg/m
minimum live load bearing capacity of a construction canopy

62

1.00m
minimum height of a protective railing in construction

63

120kg/m
minimum wind load capacity capacity for roofs for vertical projections

64

0.90m
maximum height of a handrail above the stair head

65

2.70m
minimum ceiling height for naturally ventilated rooms

66

1.20m
maximum dimension of a stair landing

67

1:10
maximum slope of an exit court

68

250mm / 0.25mm
minimum width of a run for a circular stair

69

2.00m
minimum headroom clearance for any stair

70

1:8
maximum slope for exit passageway

71

1.20m
maximum height of a siamese connection above ground

72

6.00m
maximum distance of any portion of a building from the nozzle of a 23m firehose

73

2
minimum number of exit for any stage

74

1.20m
minimum extension of a proscenium wall above the roof proscenium - the front part of the stage on an ancient Greek or Roman theater upon which the actors performed; the arch that separates the stage from the auditorium
75

750mm / 0.75m
minimum width of a stair in a stage egress

76

1.20m
maximum length of jalousie

77

900mm / 0.90m
minimum width of an exit in a stage

78

2.50m
minimum lateral bracing for skylights

79

show window
a store window in which goods are displayed

80

1.20m
maximum width of a business sign

81

1.00m
minimum distance of any sign from any electrical post or telephone wire

82

10% of lot area


minimum open space requirement for an open lot

83

300mm / 0.30m
minimum size of entrance tread for an entrance or exit step

84

1:10
maximum slope for an entrance or exit step

85

2
minimum number of steps for an entrance or exit stair

86

1:125 sq.m of GFA


office building parking ratio

87

2.40m x 5.00m
standard size of a perpendicular parking slot

88

1:10 bedrooms
hotel parking ratio

89

1:25 beds
hospital building parking ratio

90

60.00m
maximum distance of a handicapped parking space from the facility being served

91

1:5 classrooms
college or university parking ratio

92

1:50sq.m
theater, cinema, auditorium and stadium parking ratio

93

4
minimum number of wheelchair seating space for 51-300 seating capacity auditoriums

94

0.90m
minimum width of a drop curb

95

1.10m x 1.40m
minimum dimension of an accessible elevator

96

30.00m
maximum distance of an accessible elevator from the building entrance

97

3.70m
minimum width of a parking slot for the disabled

98

200mm / 0.20m
minimum run of stair for group A dwelling (residential)

99

2.10m
minimum ceiling height from 3rd floor to succeeding floors with artificial ventilation

100

6.00sq.m
minimum area of rooms for human habitation

101

30mm / 0.03m
least dimension of an air duct

102

500mm / 0.50m
maximum encroachment of a foundation into a public sidewalk

103

0.75m
width of wheelchair

104

0.70m - 1.20m
comfortable reach of persons confined to a wheelchair, is from ____m to ____m.

105

0.74m
comfortable clearance for knee and leg space under the table/ counter for a person in a wheelchair.

106

safety
AROUWSE

the basic planning requirements of BP A-Accessibility 344 are: accessibility, reachability, R-Reachability orientation, usability, workability, O-Orientation U-Usability efficiency and _______.
W-Workability S-Safety E-Efficiency

107

4
number of wheelchair seating for an assembly with seating capacity of 51300

108

RA 7277
magna carta for the disabled

109

corridor
a long interior passageway providing access to several rooms.

110

curb
a raised rim of concrete, stone or metal which forms the edge of a street, sidewalks, etc.

111 111

750mm / 0.75m
minimum distance of edge of roof eaves to property line

112

6.00m
maximum height of spires

113

2.00m
side setback for inside lot

114

250mm / 0.25m
minimum thickness of footing

115

600mm / 0.60m
minimum depth of footing

116

200kg/sq.m
minimum live load for ground floor

117

150kg/sq.m
minimum live load for second floor

118

130kg/sq.m
minimum wind load for roofs

119

750mm / 0.75m
minimum width of stairs

120

200mm / 0.20m
measurement of riser of stairs for group A dwellings

121

200mm / 0.20m
minimum run of stairs for group A dwellings

122

2.40m
ceiling height for room with artificial ventilation

123

2.70m
ceiling height for room with natural ventilation

124

2.70m
ceiling height for ground floor (group A dwelling)

125

2.40m
ceiling height for second floor (group A dwelling)

126

1.80m
ceiling height for mezzanine floor (group A dwelling)

127

2.10m
minimum headroom clearance

128

6.00sq.m
minimum size of rooms

129

2.00m
minimum room dimension

130

3.00sq.m
minimum size of kitchen

131

1.50m
minimum dimension of kitchen

132

1.20sq.m
minimum size of toilet and bath

133

0.90m
minimum dimension of toilet and bath

134

3.00cu.m
air space/volume requirement per person in a school

135

12.00cu.m
air space/volume requirement per person in offices, factories and workshops

136

14.00cu.m
air space/ volume requirement per person for habitable rooms

137

2.00m
minimum horizontal dimension of a court

138

1.20m
minimum width of an inner court

139

0.30m / 300mm
minimum dimension of an air duct

140

0.30sq.m
minimum cross section area of an air duct

141

1.80m
maximum center to center distance of a sprinkler head

142

45.00m
maximum distance to exit for structure without sprinkler system

143

60.00m
maximum distance to exit for structure with sprinkler system

144

between 0.80m - 0.90m


handrail height for fire exits

145

2 hours
minimum fire resistance rating for enclosure walls

146

2 hours
minimum fire resistance rating for smoke-proof enclosures

147

0.90m
height of guard rails

148

30 deg
angle of guard rails

149

0.30m
minimum clearance above street surface or level of court of duct or intake

150

0.60m
minimum dimension of vent shafts

151

1.20m
maximum width of exit door leaf

152

1.10m
minimum width of exit corridor

153

1300sq.cm / 0.13sq.m
minimum view panel for double acting exit door leaf

154

0.10sq.m
minimum cross section area of vent shaft per 1.00m height beyond 1.00m

155

0.60sq.m
minimum area of attic opening

156

0.60m
minimum dimension of attic opening

157

0.80m
minimum headroom clearance for attic above access opening

158

2
minimum number of exits for mezzanine area 185.00sq.m and least dimension of 18.00m

159

0.90m
minimum width of exit door leaf

160

0.20m
maximum width reduced by handrails and fully-opened doors to balconies and corridors

161

1.10m
minimum width of stairs serving more than 50 occupants

162

750mm / 0.75m
minimum width of stairs serving less than 10 occupants

163

100mm / 0.10m
maximum reduction of stair width due to trim and handrail

164

150mm / 0.15m
minimum run of a winding stair

165

300mm / 0.30m
maximum run of a winding stair

166

5mm / 0.005m
allowable tolerance in the rise and run of every step

167

3.00m
width of stair requiring an intermediate handrail

168

1.00m
minimum width of aisle serving both sides

169

7
maximum number of seats between the wall and the aisle

170

0.30m / 300mm
maximum distance between the back of a seat and the seat behind it

171

done! :)
arkireviewph@gmail.com http://arkireviewph.multiply.com

172