Commissioning

Atul sontakke

Pre-commissioning checks
Check the voltage of Module. Check the continuity of power cable. Check the polarity of power cable. Check Equipment Earthing. Check the tightening of electrical Connection. Check the tightening of structure nut bolt. Check the battery voltage.

Connect the battery


CAUTION The device will be destroyed if the battery is connected with the wrong polarity. Procedure,
Label the battery connection cables as a plus cable (A+) and a minus cable (A). Lay the battery cables in parallel between the solar charge controller and the battery. Connect the battery connection cable with the correct polarity to the middle pair of terminals on the solar charge controller (with the battery symbol). Connect battery connection cable A+ to the positive pole of the battery. Connect battery connection cable A to the negative pole of the battery. If the connection polarity is correct, the info LED illuminates green.

connect the solar module.


Procedure,
Ensure that the solar module is protected from incident light. cover the solar module from sun light. Ensure that the solar module does not exceed the maximum permissible input current. Label the solar module connection cables as a plus cable (M+) and a minus cable (M). Lay both solar module connection cables in parallel between the solar module and the solar charge controller. First connect the M+ solar module connection cable to the correct pole of the left pair of terminals on the solar charge controller (with the solar module symbol), then connect the M cable. Remove the covering from the solar module.

Load connection.

Procedure,
Label the load connection cables as a plus cable (L+) and a minus cable (L). Lay the load connection cables in parallel between the solar charge controller and the load. First connect the L+ load cable to the correct pole of the right pair of terminals on the solar charge controller (with the lamp symbol), then connect the L cable. Replace the load fuse or switch on the load.

final work
Fasten all cables with strain relief in the direct vicinity of the solar charge controller (clearance of approx. 10 cm).

Thank you

O&M
Atul sontakke

Operation
Operation

The solar charge controller immediately begins operation once the battery is connected or the external fuse is inserted. The display of the solar charge controller shows the current operating mode. User settings are not required.

Protection functions

overcharge protection. deep discharge protection. battery under voltage protection. solar module reverse current protection. The following installation faults do not destroy the controller. After correcting the fault, the device will continue to operate correctly:
Protection from solar module short circuits/incorrect solar module polarity Protection from short circuit at the load output or excessive load current Protection from solar module over current Protection from device over temperature Protection from over voltage at the load output Protection from the wrong connection sequence
8

Maintenance of Charge controller



The solar charge controller is maintenance-free. All components of the PV system must be checked at least annually, according to the specifications of the respective manufacturers. Ensure adequate ventilation of the cooling element. Check the cable strain relief. Check that all cable connections are secure. Tighten screws if necessary. Terminal corrosion.

Maintenance of Battery

Corrosion free battery connection. Cleaning of battery Connection battery and surrounding parts should be kept clean, dry, and free of acid. Replacement of water.

10

HYDROMETER REDING

11

Safety precaution of battery



Battery Do's Think Safety First. Do regular inspection and maintenance especially in hot weather. Do recharge batteries immediately after discharge. Do buy the highest RC reserve capacity or AH amp hour battery that will fit your configuration.
11. Battery Don'ts Don't add new electrolyte (acid). Don't use unregulated high output battery chargers to charge batteries. Don't place your equipment and toys into storage without some type of device to keep the battery charged. Don't disconnect battery cables while the engine is running (your battery acts as a filter). Don't put off recharging batteries. Don't add tap water as it may contain minerals that will contaminate the electrolyte. Don't discharge a battery any deeper than you possibly have to. Don't let a battery get hot to the touch and boil violently when charging. Don't mix size and types of batteries.

12

Documentation
Preparation of connection diagram. Compilation of test results. Satisfaction certificate from user.

13