RULE IX - SANITATION

SECTION 901. General Requirements Subject to the provisions of Book II of the Civil Code of the Philippines on Property, Ownership, and its Modification, all buildings hereafter erected, altered, remodeled, relocated or repaired for human habitation shall be provided with adequate and potable water supply, plumbing installation, and suitable wastewater treatment or disposal system, storm water drainage, pest and vermin control, noise abatement device, and such other measures required for the protection and promotion of health of persons occupying the premises and others living nearby. SECTION 902. Water Supply System 1. Whenever available, the potable water requirements for a building used for human habitation shall be supplied from existing municipal or city waterworks system. 2. The quality of drinking water from meteoric, surface or underground sources shall conform to the criteria set in the latest approved National Standards for Drinking Water Standards. 3. The design, construction and operation of deepwells for the abstraction of groundwater shall be subject to the provisions of the Water Code of the Philippines (PD 1067). 4. The design, construction and operation of independent waterwork systems of private housing subdivisions or industrial estates shall be governed by existing laws relating to local waterworks system. 5. The water piping installation for water supply and distribution to each fixture including the wastewater drainage with proper venting inside building and premises, shall conform to the provision of the Revised National Plumbing Code of the Philippines. SECTION 903. Wastewater Disposal System 1. Sanitary sewage from buildings and neutralized or pre-treated industrial wastewater shall be discharged directly into the nearest street sanitary sewer main of existing municipal or city sanitary sewerage system in accordance with the criteria set by the Code on Sanitation of the Philippines and the Department of Environment and Natural Resources (DENR). 2. All buildings located in areas where there are no available sanitary sewerage system shall dispose their sewage to Imhoff or septic tank and subsurface absorption field or to a suitable waste water treatment plant or disposal system in accordance with the Code on Sanitation of the Philippines and the Revised National Plumbing Code of the Philippines. 3. Sanitary and industrial plumbing installations inside buildings and premises shall conform to the provisions of the Revised National Plumbing Code of the Philippines. SECTION 904. Storm Drainage System 1. Rainwater drainage shall not discharge to the sanitary sewer system. 2. Adequate provisions shall be made to drain rainwater from low areas in buildings and their premises. 3. The drainage pipe installation and sewerage system of any premises and/or connection with any public disposal or any acceptable terminal shall conform to the Revised National Plumbing Code of the Philippines.
_________________________________________________________________________________________ 2004 Revised IRR of PD 1096 (as published by the DPWH on April 2005) page 180 of 100

SECTION 905. Pest and Vermin Control 1. All buildings with hollow and/or wood construction shall be provided with rat-proofing. 2. Garbage bins and receptacles shall be provided with ready means for cleaning and with positive protection against entry of pests and vermins. 3. Dining rooms for public use without artificial ventilation shall be properly screened. SECTION 906. Noise Pollution Control 1. Industrial establishments shall be provided with positive noise abatement devices to tone down the noise level of equipment and machineries to acceptable limits set down by the Department of Labor and Employment and the Department of Environment and Natural Resources. 2. Noise as an unwanted sound both in quality and intensity and excessive vibration whose sources in building/structure construction shall conform to acceptable limits the required emission standards of DENR. SECTION 907. Pipes Materials All pipe materials to be used in buildings/structures shall conform to the standard specifications of the Bureau of Product Standards (BPS) of the Department of Trade and Industry (DTI).

(emphases supplied) Rule X follows

_________________________________________________________________________________________ 2004 Revised IRR of PD 1096 (as published by the DPWH on April 2005) page 180 of 100

You might also like