You are on page 1of 4

Thompson

ICO4S 1/4" 3/2 50B AUTO

enoid Valve Actuator Control Direct Acting Shut Off Valve Oil & Gas Applications Turbine Fuel Control Low Pressure, High Flow Max Inlet Pressure 50 bar (725 psi) Reliable and long life, ideal for a one time installation Control of pneumatic or hydraulicDate: operated equipment

ICO4S 1/4 3/2 50B AUTO

Thompson Valves Ltd. - Maxseal Solenoid Operated Valves


Standard Features Solenoid Materials of Construction ICO4S 1/4 3/2 50B AUTO Solenoid Pot - Stainless Steel - BFC 316 Top Cover - Stainless Steel- BFC 316 Valve Body & Trim Materials - 316 Stainless Steel O-Rings Seats & Seals - High Nitrile (NBR) Coil Insulation - Class H Maximum Inlet Pressure Flow Rates 50 Bar (725 PSI)
C v = 0.6 USgpm for 1 psi K v = 8.64 l/min for 1 bar Temperature Ratings Valve Size Process Connections Conduit Connection Media Weight Media (Min/Max -20C/90C) - Ambient (Min/Max 0C/60C) 1/4" Balanced Poppet Valve 1/4" NPT M20 x 1.5 Conduit Thread Liquid & Gases 5.5 Kg

Recommended Spares Kits


Soft Spares (O-rings, Springs etc) Standard & Extreme Service Low Temperature valves Spare Coil Assembly Standard 24V DC (9.6 Watts) Other Variations Y133A010000-SS See Valve Data Sheet Y133A0101B0 See Valve Data Sheet

Options
Valve Body & Trim Materials Aluminium Bronze - Sea Water Applications Titanium - Extreme Service Applications Low Temperature Options High Temperature Options O-Rings - Low Nitrile / Fluorosilicone (Min Med/Amb -40C/-40C) High Temperature Spacer (Max Med/Amb 120C/60C) Please Call for Dimensions Process Connections Conduit Connection Extreme Service Product lead time Thread - 1/4" BSPP 1/2" NPT Increased Power Consumption Y133AA1H1BS - 1 WEEK (SUBJECT TO QUANTITIES) Other Variations - Please call for possible delivery dates

ICO4S 1/4 3/2 50B AUTO

Thompson

Thompson Valves Ltd. - Maxseal Solenoid Operated Valves


Technical Specification
Pressures Test (Proof) Pressure Maximum Inlet Pressure ATEX Clasification ATEX Certificate Certification 75 bar (1088 PSI) 50 Bar (725 PSI) Complies with ATEX Directive 94/9/EC SIRA 00ATEX1147 II 2G EExd IIC T6 (Ta = -60C to + 48C) or EExd IIC T4 (Ta = -60C to + 90C) IECEx IECEx BAS 04.0019 EExd IIC T6 (Ta = -40C to + 60C) or EExd IIC T4 (Ta = -40C to + 90C) GOST K GOST R Safety Integrity Level EExd IIC T6 (Ta = -40C to + 60C) EExd IIC T6 (Ta = -40C to + 60C) Suitable for SIL 3 Application in Simplex Mode Suitable for SIL 4 Application in Duplex Mode Ingress Protection Voltage Surge Protection Coil Insulation Performance Pull-in Voltage Response Times 87.5% of Nominal Pull-In <150ms IP66/X8, NEMA 4X Surge Suppression Diodes Class H

Drop-Out <80ms Electromagnetic Compability (EMC) EN50081-2/82-1

Valve Symbol

ICO4S 1/4 3/2 50B AUTO

Thompson Valves Ltd. - Maxseal Solenoid Operated Valves


Ordering Information

Thompson

Model

Operating Process Seat/Seal Port Config. Operation Pressure Connection Materials

Conduit Connection

Voltage

Body/Trim Materials

Y1

3
0-50 Barg (725 psi)

3
3/2 UNIVERSAL

A
Automatic

A1
A1 1/4" NPT E1 1/4" BSPP

H
H High Nitrile V Viton

1
A

B
18/33V DC 24V DC 50V DC 25V AC 110V AC 240V AC 115V DC B C G

S
S 316 SS / 316 SS M Alu Brnz / Alu Brnz 3 Titanium / Titanium

1 M20x1.5 2 1/2" NPT

ICO4S

J M R

Ordering Example

Y1
ICO4S

3
0-50 Barg (725 psi)

3
3/2 UNI

A
Auto

E1
1/4" BSPP

H
High Nitrile

1
M20 x 1.5

C
50V DC

S
316 SS / 316 SS

Power Consumption (At Nominal) eme Service


15.1 W hers Available

Valve is energised Valve 'changes over' Flow occurs between ports 'A' & 'B'

Valve is de-energised Valve resets Flow occurs between ports 'C' & 'B'

Thompson Valves reserves the right to amend product specifications or designs without notice. Information is given in good faith and no liability can be a

T
T www.thompson-valves.com

A fluid controls business of IMI plc


QACA 340 Rev. 1

You might also like