You are on page 1of 2

FLOW SWITCHES

CM
INTERCHANGEABLE PADDLES
q q

BELLOWS SEALED
q

COMPACT SIZE

15 MM TO 300 MM LINES

SWITZER style CM Flow Switches are versatile instruments designed to accept different paddle sizes to handle a wide range of flow. Simple and rugged mechanical parts ensure high reliability and near zero failures. The deflection of the paddle assembly due to velocity of flowing liquid against the restraining force of the range spring through a bellows sealed lever operates the microswitch at a pre-determined flow rate. Glandless design ensures total isolation between the process medium and the switch mechanism. The enclosure is protected against ingress of solid particles and from dripping water.

Type CM ... M .... flow switches are recommended for water and the flow rate and switching ranges are tabulated overleaf. For flow switches for liquids other than water, please consult factory. Customers are requested to furnish viscosity and specific gravity at operating temperature in their enquiry for selecting the correct size and range of the flow switch. For severe applications other flow switch models BM/BGM are available with SS wetted parts in weatherproof enclosures. For hazardous area application, model GRBM in flameproof enclosure is available. Please ask for Bulletin #40593.

GENERAL SPECIFICATION
Range Repeatability Process Connection Body Paddle Bellows Range Spring Max. Line Pressure Max. Process Temp. Pressure Loss Refer Table 2% of maximum flow Screwed 1" BSPM Brass 304 SS Phosphor Bronze 304 SS Enclosure Electrical Connection 10 BAR 100C 60 80 mbar at max. flow Deadband Mounting Switching Horizontal or Vertical pipe Snap acting SPCO (SPDT) microswitch rated 15A 230V AC (Resistive) 5 10% of maximum flow (10% at minimum set value and 5% at maximum set value) ABS plastic weatherproof to IP:52 Standard 22 mm clear entry via grommet. 3/4" ET or 1/2" NPT cable entry (optional)
# 40397 CM Preliminary

Flange / Tee (Optional) CS / 304 SS

FLOW RANGES
SWITCHING RANGE LPM + 10% OF FSR ON ON FALLING FLOW RISING FLOW MIN. MAX. MIN. MAX. MAX. FLOW (LPM WATER) AT VELOCITY 2 Mtrs / Sec

ORDERING INFORMATION
CM BASIC CATALOG NO. CM LINE SIZE 15 mm NB 015 (For other line sizes, substitute appropriate line size eg., 020 for 20 mm dia line 100 for 4" NB line etc.,) WETTED PARTS Brass body (opt. with CS Flange / Tee k ), Ph. Br. Bellows & 304 SS Paddle M PROCESS CONNECTION Threaded to 1" BSPM Flanged to 1" ANSI 150 RF Flanged to 2" ANSI 150 RF Flanged to non standard size With integral Tee SWITCHING 15A 230V AC microswitch (SPDT) 03 TH FA FB FX SL 015 M SL 03

LINE SIZE NB MM

015 j 020 j 025 j 032 040 050 065 080 100 125 150 200 250 300

3 4 10 13 16 36 45 65 190 100 380 150 600 200 1210 650 1970 1240 2600 2000

9 11 30 50 60 90 120 175 460 280 890 420 1360 510 2760 1510 3830 2410 4830 3080

7 8 14 22 30 50 75 100 250 160 500 250 700 350 1500 950 2500 1700 3400 2700

12 14 33 55 70 100 145 200 510 330 1000 500 1500 610 2950 1750 4200 2800 5300 3600

21 38 60 100 150 250 400 600 1000 1500 2000 3700 6000 8500 8500

Notes j CM ... M .... models (supplied with integral tee) for 1/2" (15 mm NB), 3/4" (20 mm NB) and 1" (25 mm NB) lines. Direct on line mounting with threaded or flanged connections are not available for these sizes. k In flanged version, the flange is not integral but screwed on to the body with a lock nut. The maximum line pressure for flanged versions should not exceed the limits specified in the specifications irrespective of the flange rating.

MOUNTING DIMENSIONS
66 80 Screwed 1" BSPM Process Connection Microswitch Adj. Screw Spring

56

54 Screwed Flange 1" / 2" RF (opt.) Paddle Line Size 29 30 Weld 1" BSPT(M) Socket Bellows

Provide straight length of piping as below: Upstream : 10 pipe dia; Downstream : 5 pipe dia. In vertical pipes the flow should be from bottom to top. Please note set value may differ as much as 20% compared to horizontal pipe installation.

Paddle

Prior notification of changes in specification is impracticable due to continuous development.

FOR SWITZER'S OFFICES IN INDIA CHECK AT:

http://www.switzerinstrument.com/offices.htm