You are on page 1of 6

Anderson Greenwood Large Bore IntelliMount System

Stabilized Connector (Futbol) System

ANDERSON GREENWOOD
INSTRUMENTATION PRODUCTS

The next generation of manifold systems

Product Overview
The Large Bore IntelliMount direct mount manifold is the next generation of the ACCU-Mount System for natural gas, liquid or steam measurement applications. Designed for close-coupling DP or multi-instruments (D/P, pressure, electronic flowmeter, etc.) to senior and junior orifice changers and/or orificeflange unions. The Large Bore IntelliMount is available in renewable metal or soft seat configurations and features either GRAFOIL or Teflon stem packings. The Large Bore IntelliMounts superior design reduces the number of leakpoints and overall installation weight in relation to the former ACCU-Mount modular manifold system. Furthermore, the Large Bore IntelliMount is factory assembled and tested, decreasing required costly field-installation time. The Large Bore IntelliMount used with Coplanar transmitters features unique patented integral differential pressure/ pressure adapter plates. This feature eliminates the otherwise required Coplanar adapter flange, removing a potential leakpoint and unnecessary weight.

Features and Benefits


Enhanced transmitter performance close coupled straight through 3/8" [10 mm] bore to transmitter, reducing gauge line error. Provides required spacing for installation via Sr. Orifice Changers without the otherwise required spacer flanges or manifolds. Optional rating to FIRESAFE API 607. Coplanar flange (Rosemount 305) elimination system available. Two-piece modular system affords permanent protection of Rosemount 305 diaphragms during maintenance procedures. No additional brackets or pipe support required. Maximum two-piece system, regardless of the number of required instruments. The DP and Gauge Pressure adapter plate integral to the manifold system eliminates the otherwise additional required flange connectors, reducing leakpoints, installation time, required components and weight. Elimination of impulse lines - direct mount system. Post installation instrument retrofit capability. Mounts all manufacturers field instruments i.e., Rosemount, Yokogawa, Smar, Taylor, Bailey, Moore, Honeywell and Foxboro. Elimination of conventional root block valve block system. Modular design allows for system hydrotest, and certification while affording instrument protection/ controlled storage until commissioning. Total installation, including transmitter, ships in one package to the field.

Flow Control
Total Flow Control Solutions

IntelliMount, ACCU-Mount, and Anderson Greenwood Instrumentation Products are either trademarks or registered trademarks of Tyco International Services AG or its affiliates in the United States and/or other countries. All other brand names, product names, or trademarks belong to their respective holders.
Copyright 2008 Tyco Flow Control. All rights reserved. AGIMC-0347-US-0801

Anderson Greenwood Large Bore IntelliMount System


Stabilized Connector (Futbol) System

Leak Point and Weight Comparison


Leak Points Comparison
Reduction of leak points by 50% Weight reduction of 60% Installation space requirements reduced by 40% Easier installation

Large Bore Intellimount:

AF/5GDB Dual Installation of Differential and Gauge Pressure Coplanar Transmitters

Materials
= Potential Leak Points

Technical Data Standard Material Traceability


Standard material traceability to EN10204-3.1, 50049-3.1, instrument and isolation/block modules bodies only.

Standard SS Valve
Body Bonnet Stem Non-Wetted Parts 316 SS 316 SS 316 SS Austenitic SS

Conventional Direct Mount:

Valve Packings and Flange Seals


Teflon (Standard) Maximum pressure: 6,000 psig [414 barg] Maximum temperature: 500F [260C] GRAFOIL (Optional) Maximum pressure: 6,000 psig [414 barg] Maximum temperature: 1000F [538C]

CS Valve
Body Bonnet Stem Non-Wetted Parts A105 CS 316 SS 316 SS Austenitic SS

Special
For severe service, manifolds are available in the following exotic materials: Monel Alloy 400 Duplex S31803 Hastelloy C276

Seat Temperatures
Delrin 200F [93C] maximum Teflon 500F [260C] maximum PEEK 400F [204C] maximum

= Potential Leak Points

Bolting
All IntelliMount assemblies are supplied with high tensile steel bolts as standard. Optional stainless steel bolts (B8M Class 2) are available; please specify when ordering. Notes
1. Coplanar is a trademark of Rosemount, Inc. 2. Delrin and Teflon are registered trademarks of E.I. duPont de Nemours and Company. 3. GRAFOIL is a registered trademark of Graftech International Inc. 4. Hastelloy is a registered trademark of Haynes International. 5. Monel is a registered trademark of Special Metals Corporation. 6. Viton is a registered trademark of DuPont Performance Elastomers.
Copyright 2008 Tyco Flow Control. All rights reserved. AGIMC-0347 2

Anderson Greenwood Large Bore IntelliMount System


Stabilized Connector (Futbol) System

Dimensions, inches [mm] Horizontal Shown


AF/3B Style
Single block for use with biplanar transmitters.
D/P

10.9 [277]

8.1 [206]

Inlet

14.0 [356]

AF/5GDB Style
Single block for dual mounted biplanar transmitters.
D/P G/P

10.5 [267]

Vent

Inlet

AFD/5GC Style
Double block for Coplanar transmitters.
D/P

9.3 [336]

Vent

Inlet

AFS/5GC Style
Single block for Coplanar transmitter.
D/P

12.2 [310]

11.2 [284]

Vent

9.3 [236]
Inlet

AFD/5GDB Style
Double block for dual mounted biplanar transmitters.
D/P G/P

12.2 [310]

8.9 [226]
14.0 [356]

Vent

10.9 [277]

Inlet

Standard Configuration Block Configuration


Copyright 2008 Tyco Flow Control. All rights reserved. AGIMC-0347 3

Anderson Greenwood Large Bore IntelliMount System


Stabilized Connector (Futbol) System

Bonnet Technology
Valve Technical Specifications
The IntelliMount features high performance valves for reliable bubble-tight performance. Isolation is achieved with the H series plug valve or the optional FIRESAFE P (use FS designation for FIRESAFE service) non-rotating stem bonnet assembly. Venting and equalizing are achieved with the H7/H5 needle/globe valve.

Features and Benefits


Body to bonnet pressure seals below threads preventing process from corroding bonnet retention threads which are loaded in compression for additional strength. Back seat design provides secondary stem seating and prevents stem blowout. Adjustable gland follower allows easy access to adjust the packing gland.

Stem threads are located above the stem packing and are completely isolated from the process. Stem packing with GRAFOIL or Teflon for bubble-tight sealing. Optional FIRESAFE block valves to AP1 607.

H5 Bonnet for Venting and Equalize Service


Needle valve 0.14" [3.5 mm] bore Rotating stem and plug Soft or metal seats 6000 psig [414 barg] Soft seat - Delrin, Teflon, PEEK Hard seat - 316/316L SS Handle Assembly PTFE Stem Packing

H7 Bonnet for Venting and Equalize Service


Needle/globe valve 0.2" [5.0 mm] bore Free swivel ball end stem 6000 psig [414 barg] -71F to 1000F [-57C to 538C] Handle Assembly Weather Resistant Plastic Cap (PTFE Packed only)

Stem Packing Below the Threads Bonnet Lock Pin Bonnet Lock Pin Metal Seat for High Temperature Applications Bonnet-to-Body Metal Seal

H Bonnet for Isolation Service


Rising plug valve [10 mm] bore Rotating stem and plug Soft or metal seats 6000 psig [414 barg] Soft seat - Delrin, Teflon, PEEK Hard seat - 316/316L SS
3/8"

P Bonnet for FIRESAFE Service


API 607 FIRESAFE Rising (non-rotating stem) plug valve 3/8" [10 mm] bore 6000 psig [414 barg] Hard seat - 316/316L SS

Handle Assembly Weather Resistant Metal Cap

Handle Assembly Weather Resistant Metal Cap Non-Rotating Stem

Bonnet Lock Pin Stem Packing Below the Threads Rising Plug

Packing

Non-Rotating Plug

Copyright 2008 Tyco Flow Control. All rights reserved.

AGIMC-0347 4

Anderson Greenwood Large Bore IntelliMount System


Stabilized Connector (Futbol) System

Stabilized Connectors (Futbols)


The Anderson Greenwood Stabilized Futbol/Connector (AGSF) is used as the connection between a orifice fitting or flange and manifold on direct mounted differential pressure measurement installations. The AGSF unique design provides support of the entire installation while transferring the radial-stress load away from the NPT connections. The AGSF comes in both a short and a long version for clearance requirements (crank handles, Simplex style clamping bar, orifice plate housing, etc.).

Features and Benefits


Unique design provides support of the entire installation while transferring the radial-stress load away from the NPT connections. Quick, easy, one-handed installation. Large footprint reduces radial-stress load on the NPT threads. Slotted bolt holes accommodate 21/8" to 21/4" bolt spacings. Available with dielectric shielding which provides a non-conductive barrier between the instrument and the orifice fitting. Universal design for both vertical and horizontal mount configurations. Available in standard length (4") or extended length (5.6") for additional clearance requirements. Oxygen or chlorine cleaning available. Available in stainless or carbon steel construction. High temperature (GRAFOIL) flange gaskets available. No special tools required for installation.

Ordering Information for Futbols


AGSF L S DI-D SSC

Body Length
S Short (standard clearance - overall length 4.0" [101.6 mm]) L Long (additional clearance - overall length 5.6" [142.4 mm])

Construction Material
S A351-CF8M (316 SS) C A216-WCB (CS)

Dielectric Shielding Option


DI-D Dielectric Shielding - Delrin Construction

Options
H OC SSA1 SSB SSC1 GRAFOIL Gaskets (not available with incorporation of dielectric shielding option) Cleaned for oxygen service SS Flange Bolt (grade 18-8) - maximum pressure rating 4500 psi [310 barg] 316 SS Flange Bolt (B8M Class 2) - will provide full pressure rating 316 Flange Bolt (B8M) - maximum pressure rating 4500 psi [310 barg]

Notes
1. 316 SS bolts lower pressure ratings to a maximum of 4500 psi [310 barg]. Consult factory for full rating with 316 SS bolts. 2. All standard AG stabilized connectors include Teflon gaskets. 3. All standard AG stabilized connectors include Carbon Steel A193 B7 bolts.

Copyright 2008 Tyco Flow Control. All rights reserved.

AGIMC-0347 5

Anderson Greenwood Large Bore IntelliMount System


Stabilized Connector (Futbol) System

Ordering Information (patent pending)


IMS Style
AF TF AFD TFD Direct Mount (Flange x Flange) 3/8" [10 mm] full bore Remote Mount (Pipe x Flange) 3/8" [10 mm] full bore Direct Mount, Double Block and Bleed (Flange x Flange) 3/8" [10 mm] Remote Mount, Double Block and Bleed (Pipe x Flange) 3/8" [10 mm]

AF

5GC

FS

Type
2 2B 2C 3 3B 3C 5G 5GC 5GB 5GD 5GDC 5GDB 5P 5PB 5PC 2-Valve Gauge Pressure Rosemount 305 2-Valve Gauge Pressure Biplanar 2-Valve Gauge Pressure Rosemount 305 with no Coplanar flange 3-Valve Rosemount 305 3-Valve Biplanar 3-Valve Rosemount 305 with no Coplanar flange 5-Valve (Gas) Rosemount 305 5-Valve (Gas) Rosemount 305 with no Coplanar flange 5-Valve (Gas) Biplanar 5-Valve, Dual Mount DP and Gauge Pressure Rosemount 305 5-Valve, Dual Mount DP and Gauge Pressure Rosemount 305, with no Coplanar flange 5-Valve, Dual Mount DP and Gauge Gas Biplanar 5-Valve (Power) Rosemount 305 5-Valve (Power) Biplanar 5-Valve (Power) Rosemount 305, with no Coplanar flange

Tap Orientation
H Horizontal V Vertical

Packing
V H Teflon GRAFOIL E Low Emissions Graphite

Seat
IS 316 SS Seat on Block and Integral on Instrument Module DI Delrin, Block Module only TI Teflon, Block Module only EI PEEK, Block Module only

Material
S 316 SS/316SSL M Monel C CS

End Connection (IMSTF or IMSTFD only)


4
1/2"

Female NPT x Female Vent Ports

Options
AM AMS BL FS CL OC SSA1 SSB SSC1 SG3 SP AGCO Mount Kit for 2-inch pipe stand mounting of manifold 316 SS AGCO Mount Kit for 2-inch pipe stand mounting of manifold Bonnet Lock Device (patent protected) FIRESAFE to API 607 Cleaned for chlorine service Cleaned for oxygen service SS Flange Bolt (grade 18-8) - maximum pressure rating 4500 psi [310 barg] 316 SS Flange Bolt (B8M Class 2) - will provide full pressure rating 316 Flange Bolt (B8M) - maximum pressure rating 4500 psi [310 barg] (Sour Gas) meets the requirements of NACE MR0175/ISO 15156-3 Corrigendum 2 (for Chloride conditions > 50 mg/l [ppm]) Special Requirements - please specify

Note
1. 316 SS bolts lower pressure ratings to a maximum of 4500 psi [310 barg]. Consult factory for full rating with 316 SS bolts.

Copyright 2008 Tyco Flow Control. All rights reserved.

AGIMC-0347 6

You might also like