Non-Composite Steel Floor Deck
STEEL DECK
I NSTI TUTE
s

copyright 2009 steel deck institute
NC1.0 - 2006 Standard for
2
Non-Composite Steel Floor Deck
NC1.0 - 2006 Standard for
AMRlCAN NA7l0NAL S7AN0AR0S lNS7l7U7/ S7L 0CK lNS7l7U7
STEEL DECK
I NSTI TUTE
s

1. General
1.1 Scope:
A. ThisSpecifcationfor
Non-CompositeSteelFloor
Deckshallgovernthematerials,
design,anderectionofcold
formednon-compositesteel
deckusedasaformfor
reinforcedconcreteslabs.

Commentary: Inthepast,most
ofthesteeldeckingusedinthe
mannerthisspecifcationcovers
wasreferredtoascentering,
however,variousroofdeckunits
havesuccessfullybeenusedas
non-compositeforms.This
specifcationisintendedtoalso
includetheseapplications.

B. Commentaryshallnotbe
consideredpartofthe
mandatorydocument.
1.2 ReferenceCodes,
Standardsand
Documents:

A. CodesandStandards:For
purposesofthisstandard,
complywithapplicable
provisionsofthefollowing
CodesandStandards:
1. AmericanIronandSteelInstitute
(AISI)Standard-North American
Specifcation for the Design
of Cold-Formed Steel Structural
Members, 2001Editionwith
Supplement2004
2.AmericanWeldingSociety-
ANSI/AWSD1.3Structural
WeldingCode/SheetSteel-98
StructuralWeldingCode-
SheetSteel
3. AmericanSocietyforTesting
andMaterials(ASTM)A653
(A653M)-06,A924(A924M)-06,
A1008(A1008M)-06
4. AmericanSocietyofCivil
Engineering(ASCE)-SEI/ASCE7-05
5. AmericanConcreteInstitute
(ACI)BuildingCode
RequirementsforReinforced
ConcreteACI318-05
6. UnderwritersLaboratories(UL)
FireResistanceDirectory-
http://www.ul.com/database2006
B. ReferenceDocuments:Referto
thefollowingdocuments:
1. SDIWhitePaper-Designingwith
SteelFormDeck-2003
2. SDIManualofConstructionwith
SteelDeck-MOC2-2006
3. SDIStandardPracticeDetails-
SPD2-2001
4. SDIDiaphragmDesignManual-
DDMO3-2004
2. Products
2.1 Material:
A. Sheetsteelforgalvanizeddeck
shallconformtoASTMA653
(A653M)StructuralQuality,with
aminimumyieldstrengthof
33ksi(230MPa).
B. Sheetsteelforuncoateddeck
shallconformtoASTMA1008
(A1008M)withaminimum
yieldstrengthof33ksi(230MPa).
Otherstructuralsheetsteelsor
highstrengthlowalloysteels
areacceptable,andshallbe
selectedfromtheNorth
American Specifcation for the
Design of Cold-Formed Steel
Structural Members.
Commentary:Materialsare
offeredinA653(A653M)grade
80steel(galvanized)or
ASTMA1008(A1008M)grade
80steel(uncoated).Thissteelhas
aminimumyieldstrengthof
80ksi(550MPa)andisgenerally
over90ksi(620MPa).TheAISI
specifcationsallowamaximum
allowablestressof36ksi
(250MPa)forthismaterial.
C. Sheetsteelforaccessoriesshall
conformtoASTMA653(A653M)
StructuralQualityforstructural
accessories,ASTMA653(A653M)
CommercialQualityfornon-
structuralaccessories,orASTM
A1008(A1008M)foreither
structuralornon-structural
accessories.Otherstructural
sheetsteelsorhighstrength
lowalloysteelsareacceptable,
andshallbeselectedfromthe
North American Specifcation
for the Design of Cold-Formed
Steel Structural Members.
D. Thedecktypeprofleand
thickness(gage)shallbeas
shownontheplans.
2.2 Tolerance:
A. Uncoatedthicknessshallnotbe
lessthan95%ofthedesign
thicknessaslistedinTable2.2.1:
B. Panellengthshallbewithinplus
orminus1/2inch(12mm)of
specifedlength.
C. Panelcoverwidthshallbeno
greaterthanminus3/8inch
(10mm),plus3/4inch(20mm).
Table2.2.1
Gage Design Minimum
No. Thickness Thickness
in. mm. in. mm.
28 0.0149 0.38 0.014 0.35
26 0.0179 0.45 0.017 0.43
24 0.0238 0.60 0.023 0.57
22 0.0295 0.75 0.028 0.71
20 0.0358 0.91 0.034 0.86
18 0.0474 1.20 0.045 1.14
16 0.0598 1.52 0.057 1.44
3
Non-Composite Steel Floor Deck
NC1.0 - 2006 Standard for
AMRlCAN NA7l0NAL S7AN0AR0S lNS7l7U7/ S7L 0CK lNS7l7U7
STEEL DECK
I NSTI TUTE
s

D. Panelcamberand/orsweepshall
benogreaterthan1/4inchin
10footlength(6mmin3m).
E. Panelendoutofsquareshallnot
begreaterthan1/8inchperfoot
ofpanelwidth(10mmperm).
2.3 Finish:
A. Galvanizingshallconformto
ASTMA924(A924M)and/or
ASTMA653(A653M).
B. Uncoated(black)shallconformto
ASTMA1008(A1008M).
C. Paintedwithashopcoatof
primerpaint(oneorbothsides)
shallbeappliedtosteelsheet
conformingtoASTMA1008
(A1008M).
D. Thefnishonthesteelnon-
compositefoordeckshallbe
suitablefortheenvironmentof
thestructure.
Commentary: Theuncoated
fnishis,bycustom,referredtoas
blackbysomeusersand
manufacturers;theuseofthe
wordblackdoesnotreferto
paintcolorontheproduct.When
galvanizedmaterialisusedto
supportareinforcedconcrete
slab,theslabdeadloadis
consideredtobepermanently
carriedbythedeck.Forany
permanentloadcarrying
function,aminimumgalvanized
coatingconformingtoASTM
A653(A653M),G30(Z090)is
recommended.
2.4 Design:
A. Deckusedasaformforstructural
(reinforced)concreteslab:
1. Thesectionpropertiesofthe
steelfoordeckunitshall
becomputedinaccordance
withtheNorth American
Specifcation for the Design of
Cold-Formed Steel
Structural Members.
2. AllowableStressDesign(ASD):
Bendingstressshallnot
exceed0.60timestheyield
strength,norexceed36ksi
(250MPa)underthecombined
loadsofwetconcrete,deck
weight,andthefollowing
constructionliveloads:
20poundspersquarefoot
(1kPa)uniformloador
150poundconcentratedload
ona1-0(300mm)wide
sectionofdeck(2.2kNperm).
Theinteractionofshearand
bendingshallbeconsideredin
thecalculations.(SeeFigure1-
AttachmentNC1)
3. LoadandResistanceFactor
Design(LRFD):Theload
combinationforconstruction
areasshowninAttachment
NC1.Loadfactorsshallbein
accordancewithASCE7.
(SeeSection1.2.A.5)The
resistancefactorsand
nominalresistancesshallbe
inaccordancewiththe
North American Specifcation
for the Design of Cold-Formed
Steel Structural Members.
Commentary: Theloading
showninFigure1,Attachment
NC1isrepresentativeof
thesequentialloadingofwet
concreteontheform.The
150poundload(perfootof
width)istheresultofdistributing
a300poundmanovera2foot
(600mm)width.
Experiencehasshownthistobea
conservativedistribution.The
metricequivalentofthe150
poundloadis2.2kNpermeter
ofwidth.Forsinglespandeck
conditions,theabilitytocontrol
theconcreteplacementmaybe
restrictedandafactorof1.5is
appliedtotheconcreteloadto
addressthiscondition;however,
inordertokeepthis50%load
increasewithinareasonablelimit,
theincreaseisnottoexceed
30psf(1.44kPa).Whenever
possible,thedeckshallbemulti-
spanandnotrequireshoring
duringtheconcreteplacement
procedure.
4. DeckDefection:Calculated
defectionsofthedeckshallbe
basedontheloadofthewet
concrete,asdeterminedbythe
designslabthicknessandthe
weightofthesteeldeck,
uniformlyloadedonallspans,
andshallbelimitedto1/180of
theclearspanor3/4inch
(20mm),whicheverissmaller.
Calculateddefectionsshallbe
relativetosupportingmembers.
Commentary: Thedefection
calculationsdonottakeinto
accountconstructionloads
becausetheseareconsidered
temporaryloads.Thedeckis
designedtoalwaysbeinthe
elasticrangesoremovalof
temporaryloadsshouldallowthe
decktorecover.Thestructural
steelalsodefectsunderthe
loadingofthewetconcrete.
Thedesignerisurgedtocheck
thedefectionofthetotalsystem,
especiallyifcompositebeams
andgirdersarebeingused.If
thedesignerwantstoinclude
additionalconcreteloadingon
thedeckbecauseofframe
defection,theadditionalload
shouldbeshownonthedesign
drawingsorstatedinthedeck
sectionofthejobspecifcations.
4
Non-Composite Steel Floor Deck
NC1.0 - 2006 Standard for
AMRlCAN NA7l0NAL S7AN0AR0S lNS7l7U7/ S7L 0CK lNS7l7U7
STEEL DECK
I NSTI TUTE
s

2.4Design:
5. MinimumBearing:Minimum
bearinglengthsshallbe
determinedinaccordance
withthewebcrippling
provisionsoftheNorth
American Specifcation for the
Design of Cold-Formed Steel
Structural Members; the
uniformloadingcaseofwet
concrete,plustheweightof
thesteeldeck,plus20psf
(1kPa)constructionloadshall
beused.
Commentary: Experiencehas
shownthat1-1/2inches(38mm)
ofbearingissuffcientfor
non-compositefoordecks.If
lessthan1-1/2inches(38mm)
ofendbearingisavailable,orif
highsupportreactionsare
expected,thedesignprofessional
shouldcheckthedeckweb
cripplingcapacity.Thedeck
mustbeadequatelyattachedto
thestructuretopreventslipoff.
6. DiaphragmShearCapacity:
Diaphragmswithout
concreteshallbedesignedin
accordancewiththeSDI
Diaphragm Design Manual,
orfromtestsconductedbyan
independentprofessional
engineer.
Commentary: Calculationsof
diaphragmstrengthandstiffness
shouldbemadeusingtheSDI
Diaphragm Design Manual.If
testingisusedasthemeansfor
determiningthediaphragm
strengthandstiffness,thenit
shouldfollowtheAISITS7-02
testprotocol.
B. ConcreteSlabDesign:
1. General:Thedesignofthe
concreteslabsshallbedonein
accordancewiththeACI
Building Code Requirements
for Reinforced Concrete. The
minimumconcretethickness
abovethetopofthedeckshall
be1-1/2inches(38mm).
Randomlydistributedfbers
orfbrousadmixturesshallnot
besubstitutedforweldedwire
fabrictensilereinforcement.
Commentary: Infollowingthe
ACIrequirementsfortemperature
reinforcement,thedesignermay
eliminatetheconcreteareathat
isdisplacedbythedeckribs.For
slabswithtotaldepthof3inches
(75mm)orless,thereinforcing
meshmaybeconsideredtobe
atthecenteroftheconcrete
abovethedeck.(RefertotheSDI
Designing with Steel Form Deck
forslabdesigninformation)If
uncoatedorpainteddeckisused
astheform,theloadfrom
concreteslabweightmustbe
deductedfromthecalculated
capacityofthereinforced
concreteslab.Ifgalvanizedform
isused,theloadfromtheslab
weightisconsideredtobe
permanentlycarriedbythedeck
andneednotbedeductedfrom
theliveload.Iftemporaryshoring
isused,theloadoftheslabmust
bedeductedfromthecalculated
capacityofthereinforcedslab,
regardlessofthedeckfnish.
Exceptforsomediaphragm
values,thedeckshouldnotbe
assumedtoactcompositelywith
theconcreteeventhoughstrong
chemicalbondscan,anddo,
develop.
2. Concrete:Concretedesign
shallbeinaccordancewith
theapplicablesectionsof
theACIBuilding Code
Requirements for Reinforced
Concrete.Minimum
compressivestrength(fc)shall
be3ksi(20MPa)orasrequired
forfreratingsordurability.
Admixturescontaining
chloridesaltsshallnotbeused.
Commentary: Theuseof
admixturescontainingchloride
saltsisnotallowedbecausethe
saltswillcorrodethesteelnon-
compositefoordeck.
3. CantileverLoads:When
cantileveredslabsare
encountered,topreinforcing
steelshallbeproportioned
bythedesigner.For
constructionloads,thedeck
shallbedesignedforthemore
severeof(a)deckplusslab
weightplus20psf(1kPa)
constructionloadonboth
cantileverandadjacentspan,
or(b)deckplusslabweight
onbothcantileverand
adjacentspanplusa
150pound(665N)
concentratedloadperfoot
ofwidthatendofcantilever.
Theloadfactorsshallbein
accordancewithASCE7.
Resistancefactorsforbending,
shear,andinteriorbearing
shallbebytheNorth American
Specifcation for the Design
of Cold-Formed Steel
Structural Members.
Themaximumcantilever
defectionasaform,under
deckplusslabweight,shallbe
a/90whereaistheclear
cantileverlength,andshallnot
exceed3/4inch(19mm).

Sidelapsshallbeattached
attheendofthecantilever
andamaximumspacingof
12inches(300mm)oncenter
fromcantileverend.Each
corrugationshallbefastened
5
Non-Composite Steel Floor Deck
NC1.0 - 2006 Standard for
AMRlCAN NA7l0NAL S7AN0AR0S lNS7l7U7/ S7L 0CK lNS7l7U7
STEEL DECK
I NSTI TUTE
s

atboththeperimetersupport
andthefrstinteriorsupport.
Thedeckshallbecompletely
attachedtothesupportsand
atthesidelapsbeforeany
loadisappliedtothe
cantilever.Concreteshallnot
beplacedonthecantilever
untilafterplacementonthe
adjacentspan.
2.5 Accessories:
A. Pourstops,columnclosures,end
closures,coverplates,and
girderfllersshallbethetype
suitablefortheapplication.Pour
stopminimumgagesshallbe
inaccordancewiththeSteelDeck
Institute.(SeePour Stop Selection
Table,AttachmentNC2)
B. Mechanicalfastenersorwelds
shallbepermittedfordeckand
accessoryattachment.
3. Execution
3.1 Installation/General:
A. Supportframingandfeld
conditionsshallbeexaminedfor
compliancewithrequirements
forinstallationtolerancesand
otherconditionsaffecting
performanceofworkofthis
section.AllOSHArulesfor
erectionshallbefollowed.
B. Deckpanelsshallbeinstalledon
aconcretesupportstructureonly
afterconcretehasattained75%
ofitsspecifeddesignstrength.
C. Deckpanelsandaccessories
shallbeinstalledaccordingto
theSDIManual of Construction
with Steel Deck,placementplans,
andrequirementsofthisSection.
D. Temporaryshoring,ifrequired,
shallbeinstalledbeforeplacing
deckpanels.Temporaryshoring
shallbedesignedtoresista
minimumuniformloadof50psf
(2.4kPa),andloadingindicated
onAttachmentNC1.Shoringshall
besecurelyinplacebeforethe
foordeckerectionbegins.The
shoringshallbedesignedand
installedinaccordancewiththe
ACIBuilding Code Requirements
for Reinforced Concrete,andshall
beleftinplaceuntiltheslab
attains75%ofitsspecifeddesign
strengthandaminimumofseven
(7)days.
E. Deckpanelsshallbeplacedon
structuralsupportsandadjusted
tofnalpositionwithends
aligned,andattachedsecurely
tothesupportsimmediatelyafter
placementinordertoformasafe
workingplatform.Alldecksheets
shallhaveadequatebearingand
fasteningtoallsupportsto
preventslipoffduring
construction.Deckendsover
supportsshallbeinstalledwith
aminimumendbearingof
1-1/2inches(38mm).Deck
areassubjecttoheavyor
repeatedtraffc,concentrated
loads,impactloads,wheelloads,
etc.shallbeadequatelyprotected
byplankingorotherapproved
meanstoavoidoverloading
and/ordamage.
Commentary: Staggeringdeck
endsisnotarecommended
practice.Thedeckcapacityasa
formandtheloadcapacityofa
non-compositedeck/slabsystem
arenotincreasedbystaggering
endjoints,yetlayoutanderection
costsareincreased.
F. LappedorButtedEnds:Deck
endsshallbeeitherlappedor
buttedoversupports.Gapsupto
1inch(25mm)shallbepermitted
atbuttedends.
G. Deckunitsandaccessoriesshall
becutandneatlyftaround
openingsandotherwork
projectingthroughoradjacentto
thedecking.
Commentary: Itisthe
responsibilityofthedesignerto
designateholes/openingstobe
deckedoverincompliancewith
applicablefederalandstate
OSHAdirectives.Careshouldbe
takentoanalyzespansbetween
supportsatopeningswhen
determiningthoseholes/
openingstobedeckedover.
Whenaframedopeningspan
exceedsthemaximumdeckspan
limitsforconstructionloads,the
openingmustbedetailedaround
insteadofdeckedover.
(Minimumconstructionload
50lbs./sq.ft.(2.4kPa),unless
specifcrequirementsdictate
otherwise).Whenaframedhole/
openinginfoordeckisshown
anddimensionedonthe
structuraldesigndrawings,pour
stop(screed)angleisrequired
totopofslab.Whenspecifed,
cellclosureangleswillbe
providedattheopenendsof
deck1-1/2inches(38mm)deep
ordeeper,instandard10feet
(3m)lengthstobefeldsized,
cutandinstalled.Typically,non-
compositefoordecksthatare
lessthan1-1/2inches(38mm)
deepdonotrequireorusecell
closure.Alternatemeanstodam
concretemaybeusedinlieuof
cellclosure,atthediscretionof
theinstaller,ifapprovedbythe
projectengineer.

6
Non-Composite Steel Floor Deck
NC1.0 - 2006 Standard for
AMRlCAN NA7l0NAL S7AN0AR0S lNS7l7U7/ S7L 0CK lNS7l7U7
STEEL DECK
I NSTI TUTE
s

3.1 Installation/General:
Whenahole/openingisnot
shownanddimensionedonthe
structuraldesigndrawings,no
provisionsforconcreteretainage
willbeprovidedbythemetaldeck
manufacturer/supplier.Metal
foordeckingholesandopenings
tobecutaftertheconcretepour
shallnotbefeldcutuntilconcrete
hasreached75%ofitsdesign
strengthandaminimumseven
(7)days.
H. Tradesthatsubsequentlycut
unscheduledopeningsthrough
thedeckshallberesponsiblefor
reinforcingtheseopenings
baseduponanapproved
engineereddesign.
3.2 Installation/Anchorage:
A. Formdeckunitsshallbe
anchoredtosteelsupporting
membersincludingperimeter
supportsteeland/orbearing
wallsbyarcspotpuddleweldsof
thefollowingdiameterand
spacing,flletweldsofequal
strength,ormechanicalfasteners.
1. Allweldingofdeckshallbe
inaccordancewithANSI/AWS
D1.3,Structural Welding Code -
Sheet Steel.Eachweldershall
demonstrateanabilityto
producesatisfactorywelds
usingaproceduresuch
asshownintheSDIManual of
Construction with Steel Deck,or
asdescribedinANSI/AWSD1.3.
2. Weldingwashersshallbe
usedonalldeckunitswith
metalthicknesslessthan
0.028inches(0.7mm).Welding
washersshallbeaminimum
thicknessof0.0598inches
(16gage,1.50mm)andhave
anominal3/8inch(10mm)
diameterhole.
3. Whereweldingwashersare
notused,aminimumvisible
5/8inch(15mm)diameter
arcpuddleweldshallbeused.
Weldmetalshallpenetrateall
layersofdeckmaterialatend
lapsandshallhavegood
fusiontothesupporting
members.
4. Weldspacing:Fastening
patternshallallowslabstobe
designedonacontinuousbasis.
5. Whenused,flletweldsshallbe
atleast1-1/2inch(38mm)long.
6. Mechanicalfasteners,either
powderactuated,
pneumaticallydriven,or
screws,shallbepermittedin
lieuofweldingtofastendeck
tosupportingframingif
fastenersmeetallproject
servicerequirements.When
thefastenersarepowder
actuatedorpneumatically
driven,theloadvalueper
fastenerusedtodetermine
themaximumfastenerspacing
shallbebasedonaminimum
structuralsupportthicknessof
notlessthan1/8inch(3mm)
andonthefastenerproviding
aminimum5/16inch(8mm)
diameterbearingsurface
(fastenerheadsize).When
thestructuralsupport
thicknessislessthan
1/8inch(3mm),powder
actuatedorpneumatically
drivenfastenersshallnotbeused,
butscrewsareacceptable.
Commentary: Mechanical
fasteners(powderactuated,
screws,pneumaticallydriven
fasteners,etc.)arerecognizedas
viableanchoringmethods,
providedthetypeandspacing
ofthefastenersatisfesthe
designcriteria.Documentation
intheformoftestdata,design
calculations,ordesigncharts
shouldbesubmittedbythe
fastenermanufacturerasthe
basisforobtainingapproval.
7. Fordeckunitswithspans
greaterthanfvefeet(1.5m),
sidelapsandperimeteredges
ofunitsbetweenspan
supportsshallbefastenedat
intervalsnotexceeding
36inches(1m)oncenter,
usingoneofthefollowing
methods:
a.#10selfdrillingscrews.
b.Crimporbuttonpunch.
c.Arcpuddlewelds5/8inch
(15mm)minimumvisible
diameter,orminimum
1inch(25mm)longfllet
weld.
Commentary: Theabovesidelap
spacingisaminimum.Service
loadsordiaphragmdesignmay
requirecloserspacingorlarger
sidelapwelds.Goodmetalto
metalcontactisnecessaryfora
goodsidelapweld.Burnholes
aretobeexpected.
B. AccessoryAttachment:
1. PourStopandGirderFillers:
Pourstopsandgirderfllers
shallbefastenedto
supportingstructurein
accordancewiththeSDI
Standard Practice Details, and
Attachment NC2.
2. FloorDeckClosures:Column
closures,cellclosures,andZ
closuresshallbefastenedto
providetightfttingclosures
atopenendsofribsandsides
ofdecking.Fastencellclosures
atchangesofdirectionoffoor
deckunitsunlessotherwise
directed.
Commentary: Cellclosuresare
generallynotusedonformdeck
of1-5/16inch(33mm)depthorless.
7
NC1.0 - 2006 Attachment NC1
AMRlCAN NA7l0NAL S7AN0AR0S lNS7l7U7/ S7L 0CK lNS7l7U7
STEEL DECK
I NSTI TUTE
s

FIGURE1
LoadingDiagramsand
BendingMoments
FIGURE2
LoadingDiagramsand
Defections
Simple
Span
Condition
Double
Span
Condition
Triple
Span
Condition
P
W1
1
+M=.25Pl+0.125W1
1
l
2
l
+M=.125(W1
1
+W2)l
2
l
W2
W1
1
P
W1
+M=.20Pl+.094W1l
2
l l
W1
+M=.094(W1+W2)l
2
l l
W2
W1
M=.117(W1+W2)l
2
l l
W2
l
l
l
P
W1
+M=.203Pl+.096W1l
2
l l
W1
+M=.096(W1+W2)l
2
l l
W2
W1
M=.125(W1+W2)l
2
l l
W2
Simple
Span
Condition
Double
Span
Condition
Triple
Span
Condition
l
l l
l l l
W1
W1
W1
.0130W1l
4
EI
= (1728)
.0054W1l
4
EI
= (1728)
.0069W1l
4
EI
= (1728)
NotesforFigures1and2 LRFDLoadFactors
P = 150poundconcentratedload................................ 1.4
I = in
4
/ft.-deckmomentofinertia
W1 = slabweight...................................................... 1.6
+deckweight...................................................1.2
W2 = 20poundspersquarefootconstructionload...............1.4
E = 29.5x10
6
psi
l = clearspanlength(ft.)
W1
1
= 1.5xslabweight+deckweight<slabweight
+30+deckweight
Dimensionalcheckshowstheneedforthe1728factorwhen
calculatingdefectionsusingpoundinchunits.
Note:Inadditiontoananalysisofslabweightplusconstructionsurcharge,thedeckmust
beindependentlyinvestigatedforatotalconstructionloadof50psf.Thesteploadsin
fgures1and2shallbeused.
Concrete Form Construction Loading Diagrams
8
NC1.0 - 2006 Attachment NC2
AMRlCAN NA7l0NAL S7AN0AR0S lNS7l7U7/ S7L 0CK lNS7l7U7
STEEL DECK
I NSTI TUTE
s

0 1 2 3 4 5 6 7 8 9 10 11 12

20 20 20 20 18 18 16 14 12 12 12 10 10
20 20 20 18 18 16 16 14 12 12 12 10 10
20 20 20 18 18 16 16 14 12 12 12 10 10
20 20 18 18 16 16 14 14 12 12 10 10 10
20 20 18 18 16 16 14 14 12 12 10 10
20 18 18 16 16 14 14 12 12 12 10 10
20 18 18 16 16 14 14 12 12 12 10 10
20 18 16 16 14 14 12 12 12 12 10 10
18 18 16 16 14 14 12 12 12 10 10 10
18 18 16 14 14 12 12 12 12 10 10
18 16 16 14 14 12 12 12 12 10 10
18 16 14 14 14 12 12 12 10 10 10
18 16 14 14 12 12 12 12 10 10 10
16 16 14 14 12 12 12 10 10 10
16 14 14 12 12 12 12 10 10 10
16 14 14 12 12 12 10 10 10 10
14 14 12 12 12 12 10 10 10
14 14 12 12 12 10 10 10 10
14 12 12 12 12 10 10 10
14 12 12 12 12 10 10 10
14 12 12 12 10 10 10
12 12 12 12 10 10 10
12 12 12 10 10 10
12 12 12 10 10 10
12 12 10 10 10 10
12 12 10 10 10
12 12 10 10 10
12 10 10 10
12 10 10 10
12 10 10
10 10 10
10 10
10 10
ovERhANG(INChES)
4.00
4.25
4.50
4.75
5.00
5.25
5.50
5.75
6.00
6.25
6.50
6.75
7.00
7.25
7.50
7.75
8.00
8.25
8.50
8.75
9.00
9.25
9.50
9.75
10.00
10.25
10.50
10.75
11.00
11.25
11.50
11.75
12.00
SLAB
(INChES)
PoURSToPTyPES
DEPTh
NoTES:ThisSelectionChartisbasedonfollowingcriteria:
1. Normalweightconcrete(150PCF).
2. Horizontalandverticaldefectionislimitedto maximumforconcretedeadload.
3. Designstressislimitedto20KSIforconcretedeadloadtemporarilyincreasedbyone-thirdfortheconstructionliveloadof20PSF.
4. PourStopSelectionChartdoesnotconsidertheeffectoftheperformance,defection,orrotationofthepourstopsupportwhichmay
includeboththesupportingcompositedeckand/ortheframe.
5. Verticallegreturnlipisrecommendedforalltypes(gages).
TYPES
DESIGN
THICKNESS
0.0358
0.0474
0.0598
0.0747
0.1046
0.1345
20
18
16
14
12
10
1 (25mm)flletwelds
@12 o.c. pourstop slab
depth
2 (50mm)min.
overhang
seenote5

m
i
n
.
SDI Pour Stop Selection Table