You are on page 1of 2

real scaffolding planks !

ROVED PP

A CS

AP

OVED PR

A CS

VED C

Lee LitetM engineered scaFFolding planks are assembled by Finger jointing and edge gluing small dimension lumber with all weather adhesives to ensure maximum strength, stability and water resistance
lighter, stronger and more durable.
meets or exceeds osha, csa, ansi and Fsc standards third-party certiFied and monitored by

Each plank is machined tested, end sealed and textured on both sides for slip-resistance Corners cut at 45

SA

AP

RO

MODeL ML1.60x9.5x96 ML1.60x9.5x120 ML1.60x9.5x192 ML115/16x9.5x96 ML115/16x9.5x120 ML115/16x9.5x144 ML115/16x9.5x192

DeSCrIPtION LeeLite Plank 8 feet OSHA LeeLite Plank 10 feet OSHA LeeLite Plank 16 feet OSHA LeeLite Plank 8 feet CSA-OSHA LeeLite Plank 10 feet CSA-OSHA LeeLite Plank 12 feet CSA-OSHA LeeLite Plank 16 feet CSA-OSHA

DIM. 1.60 x 9.25 x 8 1.60 x 9.25 x 10 1.60 x 9.25 x 16 2 x 9.25 x 8 ROVE 2 x 9.25 x 10 D PP 2 x 9.25 x 12 2 x 9.25 x 16

LBS 24.5 30.7 49.1 36.3 45.4 54.5 72.7

uPC 778300916177 778300916184 778300913084 778300913107 778300913121 778300913169

A CS

FeAtureS

AP

MECHANICAL PROPERTIES
TEsTEd in aCCordanCE wiTh ThE rEquirEmEnTs of Can/Csa s269.2-m87 PLANKS ARE ASSEMBLED BY FINGER JOINTING AND EDGE GLUING SMALL DIMENSION LUMBER WITH APPROVED ALL WEATHER ADHESIVE DRIED BLACK SPRUCE: HUMIDITY LEVEL 10 to 12% SEALED ENDS, CORNERS CUT AT 45 EACH PLANK IS MACHINE TESTED AND GRADE MARKED OSHA OR CSA

STANDARDS

OVED PR

MEETS OSHA 1926.451 MEETS ANSI A10.8-2001 MEETS CAN/CSA - S269.2 M87 RO MEETS FSC C V

A CS

ED

teCHNICAL INFOrMAtION
CANADIAN MAXIMUM SPAN DATA
sTandard PLANK END DIMENSIONS

U.S. MAXIMUM SPAN DATA


sTandard PLANK END DIMENSIONS
1/4

uSAGe

CHArGe
DEAD LOAD + ( lb / Lft. ) ( or plank width ) LIVE LOAD ( lb / ft2 )

2 x9

LIGHT HEAVY

250 lb/Lft + 25 lb/ft2 266 lb/Lft + 75 lb/ft2

10 7

uSAGe LIGHT MEDIUM HEAVY LIGHT MEDIUM HEAVY

CHArGe 25 lb/ft2 50 lb/ft2 75 lb/ft2 250 lb 500 lb 750 lb

SA

AP

1,60 x 91/4 12 10 8 8 7 5

2 x 91/4 15 12 11 13 10 6

SPeCIFICAtION DAtA
Modulus of rupture (extreme fiber stress bending) 1600 PSI (calculated for 1.5 thickness)
(COV)

coefficient of Variation Less than 12 %

NOteS
Under OSHA regulations engineered planks may replace solid sawn wook planks. The maximum spans above are based on the maximum intended load as specified and are based on OSHA and CSA criteria for stress, stiffness and design. Above table data applies to single span use under dry conditions (moisture content less than 19%) for untreated planks with no preservatives of fire retardants added. Load data applies to LeeLiteTm Planks properly used in a flat position and with adequate end-bearings. Load capacity is not limited by maximum horizontal shearat end supports. In the U.S. data table: Light (One Man) is defined as the mid-span load of a 250-pound worker plus normal tools and the weight of the plank. Medium (Two Men) or Heavy (Three Men) is as above, with workers positioned 18in. apart (as per OSHA specifications). Deflection limits based upon applied loads do not include the plank weight. A safety factor of 4:1 is allowed in all plank sizings above, as per OSHA and CSA minimum acceptable standards.

T 1 800 363-0847 450 663-3199 F 450 663-9049


LeeLite is a trademark of Architectures Toubois (2007) inc. / Modulam is a registered trademark of Architectures Toubois (2007) inc.

www.leestructuralwood.com

S-LEELITECSA-NA-EN07