Point Schedule for BMS


Equipment Qty 3 3 3 3 3 3 3 3 3 Description Chiller Start/Stop Command Command for Butterfly Valve Chiller Trip Alarm Water Flow Status Supply Chilled Water Temperature Return Chilled Water Temperature Pump Star/Stop Command Pump Run Status Pump Trip Alarm Total Points for this panel 2 2 2 2 2 2 2 2 2 2 2 2 2 Supply Fan Start/Stop Command Supply Fan Trip Alarm Supply Fan DPS Pre-Filter Status Final Filter Status Return Air Humidity + Temperature Cooling Valve Control Return Air Smoke Detector Supply Air Smoke Detector Fresh Air Damper Control Return Air Damper Control Humidity Control Electric Heater Stages Total Points for this panel Supply Fan Start/Stop Command Supply Fan Trip Alarm Supply Fan DPS Pre-Filter Status Final Filter Status Return Air Humidity + Temperature Cooling Valve Control Return Air Smoke Detector Supply Air Smoke Detector Fresh Air Damper Control Return Air Damper Control Humidity Control Electric Heater Stages 1 1 1 1 1 2 1 1 1 1 1 1 3 Input/Output Points DI DO AI AO 1 1 1 1 1 1 1 1 1 DI 0 0 3 3 0 0 0 3 3 12 0 2 2 2 2 0 0 2 0 0 0 0 0 10 0 1 1 1 1 0 0 1 0 0 0 0 0 Total I/O Points DO AI 3 0 3 0 0 0 0 0 0 3 0 3 3 0 0 0 0 0 9 2 0 0 0 0 0 0 0 2 2 2 0 6 14 1 0 0 0 0 0 0 0 1 1 1 0 3 6 0 0 0 0 0 4 0 0 0 0 0 2 0 6 0 0 0 0 0 2 0 0 0 0 0 1 0 AO 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 0 0 0 0 0 0 2 0 0 0 0 0 0 1 0 0 0 0 0 0 Controllers QTY 1 1 REMARKS

Chillers & Chilled Water Pumps Panel - 1

18X9 1 1

Air Handling Unit No. 1 &2 Panel 2

16X16 1

Air Handling Unit No. 3 Panel - 3

1 1 1 1 1 1 1 1 1 1 1 1 1

1 1 1 1 1 2 1 1 1 1 1 1 3

\\vboxsrv\conversion_tmp\scratch20184\99076971.xls.ms_office

Point Schedule

6/3/2012

Total Points for this panel 1 1 1 1 1 1 1 1 1 1 1 1 1 Supply Fan Start/Stop Command Supply Fan Trip Alarm Supply Fan DPS Pre-Filter Status Final Filter Status Return Air Humidity + Temperature Cooling Valve Control Return Air Smoke Detector Supply Air Smoke Detector Fresh Air Damper Control Return Air Damper Control Humidity Control Electric Heater Stages Total Points for this panel 1 1 1 1 1 1 1 Supply Fan Start/Stop Command Supply Fan Trip Alarm Supply Fan DPS Pre-Filter Status Cooling Stage Heating Stage Return Air Temperature Sensor Total Points for this panel 1 1 1 1 1 1 1 Supply Fan Start/Stop Command Supply Fan Trip Alarm Supply Fan DPS Pre-Filter Status Cooling Stage Heating Stage Return Air Temperature Sensor Total Points for this panel 10 10 10 10 Exhaust Fan Start/Stop Command Exhaust Fan Run Status Exhaust Fan Trip Alam Exhaust Fan Flow Status (DPS) Total Points for this panel 1 1 1 1 1 1 1 1 2 2 1 1 1 1 1 2 2 1 1 1 1 1 1 2 1 1 1 1 1 1 1

5 0 1 1 1 1 0 0 1 0 0 0 0 0 5 0 1 1 1 0 0 0 3 0 1 1 1 0 0 0 3 0 10 10 10 30

7 1 0 0 0 0 0 0 0 1 1 1 0 1 5 1 0 0 0 2 2 0 5 1 0 0 0 2 2 0 5 10 0 0 0 10

3 0 0 0 0 0 2 0 0 0 0 0 1 0 3 0 0 0 0 0 0 1 1 0 0 0 0 0 0 1 1 0 0 0 0 0

1 0 0 0 0 0 0 1 0 0 0 0 0 0 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

8X8 1

Air Handling Unit No. 4 Panel - 4

8x8 1

Package Unit No. 1 Panel - 5

4x5 1

Package Unit No. 2 Panel - 6

4x5 2

Exhaust Fans Panel - 7

30x10 1 1 1 4 4 2 Software Key RS485/USB 16x12 Controller 8x8 Controller 4x4 Controller