You are on page 1of 25

Automation Platform

Modicon TSX Micro

The truly open specialized control system

Introduction To meet exactly your need Modules and solutions TSX Micro: a long-term choice

Introduction Telemecanique, Simply Smart

Quality

Easiness

Introduction TSX Micro, for which applications ?


Machines Manufacturing Infrastructures Batch / Process

Premium

Premium

Quantum

Quantum

Size Complexity Size // Complexity

TSX Micro

TSX Micro Momentum M1

Momentum M1

Twido

Introduction Modicon TSX Micro in some figures

TSX Micro is launched since 1996 About 45 000 CPU / year for a turnover of 30 M / year TSX Micro is marketed and supported in more than 130 countries

A very large penetration in Europe and important increases elsewhere, mainly in the USA and China.

Introduction Presentation of the system Flexibility and power to meet exactly to your need Modules and solutions TSX Micro: a long-term choice

Modicon TSX Micro To meet exactly to your need

A gradual processors range


According to performance (cycle time, integrated memory capacity)

A flexible memory
The executable memory is expansible via PCMCIA board.
PCMCIA

Up to 256ko Buy no more what is Buy no more what is required required

37-0

37-1

37-2

File Storage function to store recipes or production data (historical records)

Modicon TSX Micro To meet exactly to your need

A tailor-made design
The flexibility of a modular PLC The bases are available with 24 VDC or 110..220 VAC voltage According to the type, analogue and counting channels are integrated to the base as well as communication module to provide an optimise footprint The basic models 37-0x have DI/O integrated The high-end models (37-1x et 37-2x), accept a 2nd rack, without any additional cable or extension module.

Modicon TSX Micro To meet exactly to your need

The programming language is without any compromise


4 IEC langages in standard available for all the CPUs
LD %M0 LD %M0 OR %M12 OR %M12 ST %Q1.5 ST %Q1.5

Those languages are all inborn. The cycle time or the size of the application program don t depend on which one is used Choose the language the most Choose the language the most appropriate to the function appropriate to the function

Modicon TSX Micro To meet exactly to your need

TSX Micro well designed for the most demanding applications


A very good cycle time A simple and powerful multitask system 0,15 ms / K instruction

10

Introduction Presentation of the system Flexibility and power to meet exactly to your need Modules and solutions
The Input/Output modules The specialized functions Communication

TSX Micro: a long-term choice

11

The Input/Output modules Discrete modules

A riche catalogue
Simple or format modules with a 4 to 64 channels modularity Screw terminal block or HE10 Solid-state or Relay

Advanced Functions
State memorisation Event trigger Run/Stop Data and programme storage in an internal Flash memory Alarm output

12

The Input/Output modules Analogue modules

9 integred channels to the 37-22 base


8 inputs / 1 output - 8 bits resolution Each 0-10V channel convertible in current

Or half-format modules
5 half-format modules equipped with 2, 4, 6 or 8 channels 1 mix module 4 inputs / 2 outputs for cheap solutions Multi-range : Voltage, Current, Thermocouple, Pt100 Probe Resolution : up to 16 bits

13

Introduction Presentation of the system Flexibility and power to meet exactly to your need Modules and solutions
The Inputs/Outputs modules The specialised functions Communication

TSX Micro: a long-term choice

14

The specialised functions Panorama

15

Introduction Presentation of the system Flexibility and power to meet exactly to your need Modules and solutions
Les modules d Entres/Sorties Specialised functions Communication

TSX Micro: a long-terme choice

16

Communication Panorama

17

Communication AS-Interface

Reduce the wiring cost by 40%


31 slaves / 200 m maximum Power supply and data on the same cable Screw terminal block or M12

Keep control
Simple diagnostic on the integrated display or from the adjustment tool Automatic mapping when faulty device substitution

18

Communication CANopen (1)

The bus dedicated to the industrial machine


127 slaves - 100 m maximum (30m at 1Mb) For sensors and drives High data flexibility and security transfert

A low-cost openness
A low-cost master PCMCIA board with its integrated TAP A cheap bundle composed of a PL7 Micro release and SyCon tool

19

Communication CANopen (2)

TegoPower

Altivar Lexium TwinLine

Advantys STB

Advantys FTB

Advantys FTM

20

Communication TCP/IP Ethernet or TCP/IP Modem


TCP/IP Ethernet TCP/IP Ethernet TCP/IP Modem TCP/IP Modem

In local or by remote access: same services In local or by remote access: same services

A multi-protocole delivery service


Modbus Uni-TE that guaranties a full Xway transparency

High network services


BOOTP : attribution of IP address via a server SNMP : network management protocol DHCP : automatic reconfiguration by replacing a faulty module

21

Communication Web server through TCP/IP Ethernet or TCP/IP Modem


An integrated ready-to-use Web server (TSX ETZ)
PLC & I/O Diagnostic Diagnostic of the CPU but the modules as well The defects are clearly displayed Diagnostic and adjustment of the application Data Editor : Display and/or data modification

Create your own pages


Up to 8Mo available : to design anHMI accessible from a simple navigateur to integrate graphic diagnostic pages to create hyperlinks to other web sites or documentations
Blocage pices

Graphic object editor, HTML and Java openness- Gif and Flash Animations

22

Introduction Presentation of the system Flexibility and power to meet exactly to your need Modules and solutions
The Inputs/Outputs modules The specialised functions Communication

TSX Micro: a long-term choice

23

To make the right choice Catalogue


37-05
DI/DO Max DI/DO Max AI/AO Max AI/AO Max Nr of free slots Nr of free slots Integrated DI/DO Integrated DI/DO Integrated AI/AO Integrated AI/AO Integrated counters Integrated counters Ethernet Ethernet CANOpen (*) CANOpen (*) AS-i AS-i Memory (Ko) Memory (Ko) File Storage (Ko) File Storage (Ko)

37-08
120 120 16 16 2 2 32/24 32/24

37-10
184 184 16 16 4..8 4..8

37-21
248 248 32 32 6..10 6..10

37-22
248 248 41 41 6..10 6..10

92 92 16 16 2 2 16/12 16/12

8/1 8/1 2 2 1 1 1 1 1 1 1 1 22 22 22 22 28 28 1 1 40..256 40..256 256 256 1 1 1 1 1 1 40..256 40..256 256 256

24

To make the right choice Catalogue

25

You might also like