You are on page 1of 4

C Item No.

1 2

CONCRETOR Description Unit Rate (RM)

Lean concrete (Grade 15) in 50mm thick blinding. Mass Concrete (Grade 20) in non structural works such as pavements, upstands, kerbs and the like. Reinforced concrete (Grade 25) in sub-structural works such as pile caps, pad footings, column stumps, and the like. Reinforced concrete (Grade 30) in sub-structural works such as pile caps, pad footings, column stumps, and the like. Reinforced concrete (Grade 40) in sub-structural works such as pile caps, pad footings, column stumps, and the like. Reinforced concrete (Grade 25) in sub-structural works such as ground beams, ground slab, apron slabs, steps, platform slabs, ramp and the like. Reinforced concrete (Grade 30) in sub-structural works such as ground beams, ground slab, apron slabs, steps, platform slabs, ramp and the like. Reinforced concrete (Grade 40) in sub-structural works such as ground beams, ground slab, apron slabs, steps, platform slabs, ramp and the like. Reinforced concrete (Grade 25) in super-structural works such as columns, stiffeners, walls, and the like. Reinforced concrete (Grade 30) in super-structural works such as columns, stiffeners, walls, and the like. Reinforced concrete (Grade 40) in super-structural works such as columns, stiffeners, walls, and the like. Reinforced concrete (Grade 25) in super-structural works such as suspended floor beams, suspended floor slabs, roof beams, roof slabs, gutter, canopy slabs, staircases, landing slab, and the like. Reinforced concrete (Grade 30) in super-structural works such as suspended floor beams, suspended floor slabs, roof beams, roof slabs, gutter, canopy slabs, staircases, landing slab, and the like. Reinforced concrete (Grade 40) in super-structural works such as suspended floor beams, suspended floor slabs, roof beams, roof slabs, gutter, canopy slabs, staircases, landing slab, and the like. Mass Concrete (Grade 20) in civil works such as fencing post footings, thrust blocks, scour stops, road kerb bedding, and the like. Reinforced concrete (Grade 25) in road pavement slabs, cross-over slabs, and the like. Reinforced concrete (Grade 25) in sewerage works such as septic tanks, manholes, and the like.

12.50

M3

260.00

M3

280.00

M3

300.00

M3

340.00

M3

290.00

M3

310.00

M3

350.00

M3

290.00

10

M3

310.00

11

M3

350.00

12

295.00

13

315.00

14

M3

355.00

15

M3

260.00

16

M3

280.00

17

M3

300.00

SOR BUILDING 2008/Page 9 of 41

C Item No. 18

CONCRETOR... (CONT'D) Description Unit Rate (RM)

Mild steel bars in reinforcement to concrete work generally including all cutting, bending and placing in position: a) 6 mm Diameter. b) 10mm Diameter. c) 12mm Diameter. d) 16mm - 32mm Diameter. e) above 32mm Diameter. KG KG KG KG KG 3.00 3.00 3.00 2.90 2.90

19

High tensile steel bars in reinforcement to concrete work, generally including all cutting, bending and placing in position: a) 10mm Diameter. b) 12mm Diameter. c) 16mm - 32mm Diameter. KG KG KG 3.00 3.00 2.90

20

Welded steel fabric reinforcement of 100mm x 200mm weighing 3.73 kg/ms and embedded in concrete (MS-B283/ B6). Welded steel fabric reinforcement of 100mm x 200mm mesh weighing 4.53 kg/ms ditto(MS-B385/B7). Welded steel fabric reinforcement of 100mm x 200mm mesh weighing 5.93 kg/m2 ditto (MS-B503/B8). Welded steel fabric reinforcement of 100mm x 200mm mesh weighing 6.97 kg/m2 ditto (MS-B636/B9). Welded steel fabric reinforcement of 200mm x 200mm mesh weighing 2.22 kg/ms ditto(MS-A142/A6). Welded steel fabric reinforcement of 200mm x 200mm mesh weighing 3.02 kg/ms ditto(MS-A193/A7). Welded steel fabric reinforcement of 200mm x 200mm mesh weighing 3.95 kg/m2 ditto (MS - A252/A8). Welded steel fabric reinforcement of 200mm x 200mm mesh weighing 4.99 kg/m2 ditto (MS-A318/A9). Welded steel fabric reinforcement of 200mm x 200mm mesh weighing 6.16 kg/ms ditto(MS-A393/A10). Expanded metal reinforcement of 100mm x 400mm weighing 2.61kg/ms (MSC283/ C6). Expanded metal reinforcement of weighing 4.34 kg/ms (MS-C503/ C8).

M2

20.90

21

M2 M2

25.40

22

33.20

23

M2

39.00

24

M2

12.50

25

M2

17.00

26

M2

22.50

27

M2

28.00

28

35.00

29

M M

14.60 24.30

30

SOR BUILDING 2008/Page 10 of 41

C Item No. 31

CONCRETOR... (CONT'D) Description Unit Rate (RM)

Mild steel fabric mesh reinforcement : a) b) c) BRC 65. BRC 66. BRC 610. M M M
2

8.80 7.40 5.20

Sawn Formwork As Specified 32 33 34 35 36 37 38 39 To sides of foundation and ground beam. To sides of wall. To sides of column, staircase, lintols etc. To sides and soffit of beam. To soffit of suspended floor slab, roof slab, landing slab etc. Extra over last four items for sloping surfaces. Extra over formwork for curved on plan and elevation to varying radius. Extra over for strutting to soffits of slab/ beams exceeding 3.60m high for every 600mm stages. Extra over sawn formwork for wrot surfaces. Extra over sawn formwork for patterned formwork with fillets at 150mm centres or in 150mm wide "V" jointed timber boards. 12mm Bitumen impregnated fibreboard 150mm wide as expansion joint filler in reinforced concrete structure including filling 10mm x 10mm recess with non shrinkable mastic grouting. Precast Concrete Work 43 150 mm Wide internal precast reinforced concrete (Grade 25) half round surface water drain channel including bends, junctions etc. finished fair on exposed surfaces and bedding as specified, including all necessary excavations and part backfill. 225 mm Wide internal precast reinforced concrete (Grade 25) half round surface water drain channel including bends, junctions etc. finished fair on exposed surfaces and bedding as specified, including all necessary excavations and part backfill. 300 mm Wide internal precast reinforced concrete (Grade 25) half round surface water drain channel including bends, junctions etc. finished fair on exposed surfaces and bedding as specified, including all necessary excavations and part backfill. M
2

32.00 32.00 33.00 33.00 35.00 2.50 5.00

M2 M
2

M2 M2 M2 M2

M2 M2

4.00 6.00

40 41

M2

15.00

42

28.00

22.00

44

33.00

45

36.00

SOR BUILDING 2008/Page 11 of 41

C Item No. 46

CONCRETOR... (CONT'D) Description Unit Rate (RM)

375 mm Wide internal precast reinforced concrete (Grade 25) half round surface water drain channel including bends, junctions etc. finished fair on exposed surfaces and bedding as specified, including all necessary excavations and part backfill. 450mm x 450mm x 75mm Thick precast reinforced concrete (Grade 25) 'longkang pencegah malaria' finished fair on exposed surfaces and bedding as specified including all necessary excavation. 50mm Thick precast reinforced concrete (Grade 25) drain cover with and including one layer of fabric reinforcement, weighing 2.35kg/m2 (A6). 112mm x 150mm Precast concrete (Grade 25) lintol including formwork but excluding reinforcement. DAMP PROOF MEMBRANE

45.00

47

112.00

48

M2

35.00

49

17.00

50

`Pabkote No.3' or other approved bituminous damp proof membrane applied on concrete surfaces all to the approval of the S.O and in accordance with the manufacturer's instruction. Bitumen based expansion joints for concrete pavement.

M2 M

5.00 10.00

51

SOR BUILDING 2008/Page 12 of 41