Remote Monitoring and Control of Street Lighting
With GE Lighting Systems Remote Monitoring and Control of street lighting, entire street lighting systems can now be monitored and controlled remotely. By attaching a Checkpoint monitoring device directly into the fixtures photoelectric sensor receptacle, a wireless transceiver within the checkpoint communicates over the internet. System operators are now able to reduce maintenance loss and improve service levels as failures are immediately identified. Compared to existing methods of collecting, recording and communicating information on the status and condition of street lights, this system continuously monitors, diagnoses and then communicates the data. Network information is accessible through a user friendly web browser interface. GE Lighting Systems helps street lighting managers deliver sustainable improvements in maintenance productivity, asset life extension, and reduced energy consumption.

GE Lighting Systems remote monitoring control - Imagination at work

FEATURES Monitoring -

FUNCTION Cycling Lamp Photo-control fault Component malfunction Date/Time first reported Command individual or groups of fixtures on or off

BENEFITS Faster trouble shooting for lower maintenance costs. Reduced patrolling and inventory costs. Relamping efficiency and cost savings. Improved customer satisfaction through more accurate analysis & response Lower energy consumption Improved customer satisfaction through more accurate analysis & response

Control -

UpDate
O D U C

STREET LIGHITNG - Remote Monitoring

ORDERING NUMBER LOGIC CP TL


PRODUCT
XXXX CP = CheckPoint

3
VOLTAGE
X 3 = 120 to 277 VAC

09
FREQUENCY
XX 09 = 900 MHz

0
ANTENNA
X 0 = Internal

OA
OPTIONS
XX OA = Standard Gray OB = Black OG = Green OS = Special OA = Standard Gray

CONNECTION
XX TL = Via twist lock photocell

APCP = Combination Access Point & CheckPoint

TL = Via twist lock

3 = 120 to 277 VAC

09 = 900 MHz

1 = Dipole

TECHNICAL
INSTALLATION & DEPLOYMENT The Checkpoint Module is made of thermoplastic polyester resins designed to meet ANSI C136.10 requirements. Each check point contains an FCC approved unlicensed frequency band wireless transceiver with internal antenna. The Checkpoint us mounted on the fixture at the photo-controller twist-lock socket. The combination AP/CP device is installed in the same way:

g
P.O. Box 4506 Hendersonville, North Carolina USA 28793-4506 www.gelightingsystems.com PHONE: 828.693.2000

Mounted to Photo-controller twist-lock socket.