HT 65C

Air Source High Temperature Heat Pumps


HIGH TEMPERATURE HEAT PUMP DESIGNATION MEANS THE UNIT IS DESIGNED TO DELIVER A 60C OUTPUT TEMPERATURE AT A -5C AMBIENT CONDITION

Unit Description

HEATING

HOT WATER

MODULAR

The DeLonghi AW HT represents the next generation of air source heat pumps with an output temperature of 65C. Unlike medium temperature heat pumps these units are able to provide an output of 65C in ambient temperatures as low as -12C with a minimum operating temperature of -20C. This DeLonghi AW HT range of air source heat pumps provides an extremely high level of performance and a high level of specification which makes them ideal for retrofit applications for both the residential and commercial sectors. The fact that the installer has to only provide minimal modifications to the existing heating distribution system and hot water cylinder/tank (due to the 65C output temperature of the unit) provides significant installation benefits in terms of cost & time on a retrofit or boiler replacement application**. The nominal refrigeration COP* (efficiency) of these units is very high averaging over 4.15 but importantly the performance of these units in reducing ambient temperatures is also at an extremely high level.

***modular capability

Unit Summary
HT UNITS: AW HT CAPACITY: 10kW-27kW POWER SUPPLY: Single Phase & Three Phase models These units provide an output temperature of 65C for either heating or DHW production. HIGH EFFICIENCY & PERFORMANCE: COP 4.15 (415% efficient)
*Average coefficient of performance (COP) for the AW HT range based on an ambient temperature of 7C and 35C flow temperature

These units incorporate a built in heating system circulation pump, control for hot water production including Y Plan valve (optional, not supplied as standard) operation along with full weather compensation and sophisticated controls. This advanced control means that these units are able to operate with very low system volumes, a minimum dedicated volume of 14 litres per nominal kW of Heat Pump capacity is required which can reduce installation costs considerably. A buffer tank is required to achieve maximum operational efficiency in order to provide thermal mass and efficient defrost capability. DeLonghi-Climaveneta units are high specification heat pumps which are built to exacting standards with regard to efficiency and functionality. All the units are European manufactured and benefit from the DeLonghi-Climaveneta approach to product development and quality management providing the complete package that would be expected from a premier manufacturer.

COP 3.77 (377% efficient @ 2C ambient & 35C flow temp)


NOTE. Actual system efficiency (COP) and annual performance will depend on the distribution/emiiter system utilised. Care should be taken to ensure that the heat pump is installed in order to provide efficient operational performance.

FEATURES & OPERATIONAL BENEFITS: MSC accredited heat pumps, certificate HP0005 Full DHW and heating control Built in circulation pump High COP 4.22 Pro extended control for high efficiency Minimum defrost time with a minimum operating temperature of -20C 65C operation at -12C ambient temperature
AXIAL

*(COP is shown without circulation pump input power. Please note that unlike most other heat pumps these units incorporate built in circulation pumps, therefore by not including the circulation pump input power we are able to provide a direct performance comparison with other units).

**Please note that this unit is capable of providing a maximum output temp of 65C, the unit will provide this output temperature for heating only at the times of year where it is necessary. ie: The weather compensation control incorporated within the unit will provide correspondingly lower output temperatures to match external ambient temperatures, therefore providing a high seasonally corrected Coefficient of Performance.

Microgeneration scheme accreditation allows access to grant funding and also guarantees performance and manufacturing quality.
Certificate Number MSC HP0005 Heat Pumps

ICS01_i-KI F028.3/5

Commercial Heat Pumps

Residential Heat Pumps

HT 65C Air Source High Temperature Heat Pumps


Main Components
Housing and base are made from hot-galvanized epoxy powder coated sheet metal High efficiency and low pressure drop stainless steel (AISI 316) water exchangers, with anti-freeze heating element and differential pressure switch High efficiency cycle EVI Hermetic Scroll Compressor (with hot gas direct injection into the compressor) to reach 65C, with the crankcase heater and thermal protection Condensers finned tubes with copper and aluminium fins high exchange surface (100% fully quality tested); sub cooling circuit to prevent the icing at the basement Axial electric fans, external rotor, electric motor with a 6-pole fitted with thermal protection, housed in aerodynamic conveyor profile with safety grill A condense collecting tray within water discharge Condensing coil protection grills Soft start for 230V/1/50Hz units (45 amps) The water circuit comes complete with: - circulation pump for all models - differential pressure switch on plant side - expansion vessel Heat Pump circuit only - safety valve - manual filling assembly - pressure gauge Remote outside air sensor (wired) Remote internal keyboard kit (wired) The electronic board PRO EXTENDED allows for control of: - circulation pump on system side - domestic hot water control by external Y Plan three-way valve (accessory) - outdoor temperature sensor for modulating set point weather compensation

NB: Optional equipment includes a range of tanks & cylinders plus standard installation packs, see current price list or contact ICS HPT or your supplier for details.

AW HT
Nominal heating power Total absorbed power COP Heating capacity Total absorbed power COP Heating capacity Total absorbed power COP Heating capacity Total absorbed power COP Compressor type N. Compressors Refrigerant N. fans Plant side pump type Electrical power supply Start-up current Sound power Sound pressure Length Height Width Operational weight (1) (2) (3) (2) (4) (2) (5) (2) kW kW kW kW kW kW kW kW

0031MS
10.4 2.50 4.10 10.4 3 3.30 9.10 2.50 3.44 7.80 3.80 1.97

0041MS
14.9 3.50 4.12 14.3 4 4.48 12.5 3.30 3.66 11.4 5.40 2.06

0041T
14.1 3.30 4.14 14.3 4 3.48 12.5 3.30 3.66 11.4 5.40 2.06

0061T

0071T
26.6 6.1 4.26 27.1 7.4 3.58 23.5 5.9 3.88 21.2 10.4 1.99

0041TS
14.1 3.30 4.14 14.3 4 3.48 12.5 3.30 3.66 11.4 5.40 2.06

0061TS
19.7 4.70 4.12 19.7 5.60 3.45 17.5 4.60 3.72 14.8 7.60 1.91

0071TS
26.6 6.1 4.26 27.1 7.4 3.58 23.5 5.9 3.88 21.2 10.4 1.99

N. N. (6) V-Ph~Hz A dB(A) dB(A) mm mm mm kg 230-1~50 44 70 55 900 1240 420 150 230-1~50 45 70 55 900 1390 420 160 2 2

(7) (8)

19.7 4.70 4.12 19.7 5.60 3.45 17.5 4.60 3.72 14.8 7.60 1.91 SCROLL EVI 1 R407C 2 2 Ci 400-3N~50 400-3N~50 64 101 70 71 55 56 900 900 1390 1390 420 420 160 170

3 400-3N~50 99 74 59 1470 1700 570 320

2 400-3N~50 35 70 55 900 1390 420 160

2 400-3N~50 55 71 56 900 1390 420 170

3 400-3N~50 99 74 59 1470 1700 570 320

BI-VALENT INTEGRATED CONTROL


BI-VALENT

Integrated bi-valent systems are now becoming more relevant, a heat pump operating with a secondary heat source is a practical option should the application demand this type of system. The integrated controller will provide an interface between the heat pump and the secondary heat source subject to appropriate system design.

MODULAR CAPABILITY
MODULAR

The AW HT range is designed for modular application to accommodate multi unit larger capacity requirements***.
L

Note:
1. 2. 3. 4. 5. 6. 7. 8. Water in-out 30/35C (plant side), outdoor air temperature 7C b.s./ 6C b.u. Total input is obtained from compressor input and fan input Water in-out 40/45C (plant side), outdoor air temperature 7C b.s./ 6C b.u. Water in-out 30/35C (plant side), outdoor air temperature 2C b.s./ 1C b.u. Water 65C, outdoor air temperature -7C b.s./ 1C b.u. Ci=Circulator; Ce=Centrifugal Sound power level according to ISO 9614 and Eurovent 8/1 Average sound pressure level above one reflecting surface (Q=2) at 1 meter from the outside dimensions of the unit

Speak to the specialists now: 08452 417 617 or visit www.icsheatpumps.co.uk


ICS Renewable Energy Ltd (T/A ICS Heat Pump Technology) and/or Climaveneta S.p.A (DeLonghi) reserve the right to change update or alter the specification & details of any item shown with or without prior notice for whatever reason. The information provided within the product guide and/or data sheets is intended for guidance purposes only, please confirm actual current specification and equipment details at point of quotation and/or order.