Unit Description
HEATING
HOT WATER
MODULAR
The DeLonghi AW HT represents the next generation of air source heat pumps with an output temperature of 65C. Unlike medium temperature heat pumps these units are able to provide an output of 65C in ambient temperatures as low as -12C with a minimum operating temperature of -20C. This DeLonghi AW HT range of air source heat pumps provides an extremely high level of performance and a high level of specification which makes them ideal for retrofit applications for both the residential and commercial sectors. The fact that the installer has to only provide minimal modifications to the existing heating distribution system and hot water cylinder/tank (due to the 65C output temperature of the unit) provides significant installation benefits in terms of cost & time on a retrofit or boiler replacement application**. The nominal refrigeration COP* (efficiency) of these units is very high averaging over 4.15 but importantly the performance of these units in reducing ambient temperatures is also at an extremely high level.
***modular capability
Unit Summary
HT UNITS: AW HT CAPACITY: 10kW-27kW POWER SUPPLY: Single Phase & Three Phase models These units provide an output temperature of 65C for either heating or DHW production. HIGH EFFICIENCY & PERFORMANCE: COP 4.15 (415% efficient)
*Average coefficient of performance (COP) for the AW HT range based on an ambient temperature of 7C and 35C flow temperature
These units incorporate a built in heating system circulation pump, control for hot water production including Y Plan valve (optional, not supplied as standard) operation along with full weather compensation and sophisticated controls. This advanced control means that these units are able to operate with very low system volumes, a minimum dedicated volume of 14 litres per nominal kW of Heat Pump capacity is required which can reduce installation costs considerably. A buffer tank is required to achieve maximum operational efficiency in order to provide thermal mass and efficient defrost capability. DeLonghi-Climaveneta units are high specification heat pumps which are built to exacting standards with regard to efficiency and functionality. All the units are European manufactured and benefit from the DeLonghi-Climaveneta approach to product development and quality management providing the complete package that would be expected from a premier manufacturer.
FEATURES & OPERATIONAL BENEFITS: MSC accredited heat pumps, certificate HP0005 Full DHW and heating control Built in circulation pump High COP 4.22 Pro extended control for high efficiency Minimum defrost time with a minimum operating temperature of -20C 65C operation at -12C ambient temperature
AXIAL
*(COP is shown without circulation pump input power. Please note that unlike most other heat pumps these units incorporate built in circulation pumps, therefore by not including the circulation pump input power we are able to provide a direct performance comparison with other units).
**Please note that this unit is capable of providing a maximum output temp of 65C, the unit will provide this output temperature for heating only at the times of year where it is necessary. ie: The weather compensation control incorporated within the unit will provide correspondingly lower output temperatures to match external ambient temperatures, therefore providing a high seasonally corrected Coefficient of Performance.
Microgeneration scheme accreditation allows access to grant funding and also guarantees performance and manufacturing quality.
Certificate Number MSC HP0005 Heat Pumps
ICS01_i-KI F028.3/5
NB: Optional equipment includes a range of tanks & cylinders plus standard installation packs, see current price list or contact ICS HPT or your supplier for details.
AW HT
Nominal heating power Total absorbed power COP Heating capacity Total absorbed power COP Heating capacity Total absorbed power COP Heating capacity Total absorbed power COP Compressor type N. Compressors Refrigerant N. fans Plant side pump type Electrical power supply Start-up current Sound power Sound pressure Length Height Width Operational weight (1) (2) (3) (2) (4) (2) (5) (2) kW kW kW kW kW kW kW kW
0031MS
10.4 2.50 4.10 10.4 3 3.30 9.10 2.50 3.44 7.80 3.80 1.97
0041MS
14.9 3.50 4.12 14.3 4 4.48 12.5 3.30 3.66 11.4 5.40 2.06
0041T
14.1 3.30 4.14 14.3 4 3.48 12.5 3.30 3.66 11.4 5.40 2.06
0061T
0071T
26.6 6.1 4.26 27.1 7.4 3.58 23.5 5.9 3.88 21.2 10.4 1.99
0041TS
14.1 3.30 4.14 14.3 4 3.48 12.5 3.30 3.66 11.4 5.40 2.06
0061TS
19.7 4.70 4.12 19.7 5.60 3.45 17.5 4.60 3.72 14.8 7.60 1.91
0071TS
26.6 6.1 4.26 27.1 7.4 3.58 23.5 5.9 3.88 21.2 10.4 1.99
N. N. (6) V-Ph~Hz A dB(A) dB(A) mm mm mm kg 230-1~50 44 70 55 900 1240 420 150 230-1~50 45 70 55 900 1390 420 160 2 2
(7) (8)
19.7 4.70 4.12 19.7 5.60 3.45 17.5 4.60 3.72 14.8 7.60 1.91 SCROLL EVI 1 R407C 2 2 Ci 400-3N~50 400-3N~50 64 101 70 71 55 56 900 900 1390 1390 420 420 160 170
Integrated bi-valent systems are now becoming more relevant, a heat pump operating with a secondary heat source is a practical option should the application demand this type of system. The integrated controller will provide an interface between the heat pump and the secondary heat source subject to appropriate system design.
MODULAR CAPABILITY
MODULAR
The AW HT range is designed for modular application to accommodate multi unit larger capacity requirements***.
L
Note:
1. 2. 3. 4. 5. 6. 7. 8. Water in-out 30/35C (plant side), outdoor air temperature 7C b.s./ 6C b.u. Total input is obtained from compressor input and fan input Water in-out 40/45C (plant side), outdoor air temperature 7C b.s./ 6C b.u. Water in-out 30/35C (plant side), outdoor air temperature 2C b.s./ 1C b.u. Water 65C, outdoor air temperature -7C b.s./ 1C b.u. Ci=Circulator; Ce=Centrifugal Sound power level according to ISO 9614 and Eurovent 8/1 Average sound pressure level above one reflecting surface (Q=2) at 1 meter from the outside dimensions of the unit