M500 / M1500

M500 (Globe)

Full Port Ductile Iron Dual Chamber


Basic Valve

M1500 (Angle)
L

The Watts ACV Models M500 and M1500 are full port, dual
chamber basic valves that incorporate a one-piece disc and diaphragm assembly. This assembly is the only moving part within
the valve, allowing it to open or close as commanded by the pilot
control system.

When pressure is applied to the upper diaphragm chamber and


released from the lower diaphragm chamber, the valve travels
to a closed position. When pressure is applied to the lower
diaphragm chamber and released from the upper diaphragm
chamber the valve travels to a full open position. When pressure
is balanced between the upper and lower diaphragm chambers,
the valve will hold an intermediate position until commanded to
modulate open or closed by the pilot control system.

K
H I J
A

E
F
G

B
C

Model M500: Globe Pattern Dual Chamber Basic Valve


Model M1500: Angle Pattern Dual Chamber Basic Valve

Dimensions
Valve Size

Globe
Thread
A

Globe 150# Globe 300#


B

Cover To
Center
D

Angle
Thread
E

Angle 150# Angle 300#


F

Angle
Thread
H

Angle 150# Angle 300#


I

Port Size

Port Size

Port Size

Shipping
Weights*

in.

mm

in.

mm

in.

mm

in.

mm

in.

mm

in.

mm

in.

mm

in.

mm

in.

mm

in.

mm

in.

mm

in.

mm

in.

mm

in.

mm

50

938

238

938

238

10

254

8916

217

102

434

121

127

314

83

314

83

312

89

38

10

12

13

14

lbs. kgs.
45

20

212

65

11

279

11

279 1158 295 10516 262

512

140

512

140

578

149

102

102

4516

110

12

13

12

13

12

13

70

32

1212 318

614

159

412

114

45

80

12

305 1314 337 11316 284

152

638

162

102

438

111

12

13

12

13

12

13

100

100

15

381 1558 397 1414 362

712

191

778

200

127

5516

135

34

19

34

19

12

13

200

91

150

20

508

10

254 1012 267

152

612

165

34

19

34

19

34

19

340

154

200

2538 645 2638 670 211316 554

1234 324 1314 337

203

812

216

25

25

25

665

302

10

250

29

14

219

9516

237

25

25

25

980

445

34

21

756 31

18

533 18716 468


791 23

38

594

78

378 15

9 16

395

58

12

300

34

864 3512 902 29516 745

432 1734 451

1334 349 1412 368

25

114

32

25

1720 780

14

350

39

991 4012 1029

32

813

1912 495 2014 514

1478 378 1558 397

25

112

38

25

2600 1180

16

400

4138 1051 4312 1105

35

889

201316 529 2158 549

151116 398 1612 419

25

51

17

Standard Materials

Operating Pressure

Body & Cover:

Threaded = 400psi (27.6 bar)

Ductile Iron ASTM A536

Coating: NSF Listed Fusion Bonded Epoxy Lined


and Coated
Trim: 316 Stainless Steel

150 Flanged = 250psi (17.2 bar)


300 Flanged = 400psi (27.6 bar)

Elastomers: Buna-N (standard)


EPDM (optional)
Viton (optional)

Operating Temperature

Stem, Nut & Spring: Stainless Steel

Viton: 250F (121C) Maximum

Buna-N: 160F (71C) Maximum


EPDM: 300F (140C) Maximum

Viton is a registered trademark of DuPont Dow Elastomers.


Watts product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measurements,
please contact Watts Technical Service. Watts reserves the right to change or modify product design, construction, specifications, or materials without prior notice and without incurring any obligation to make such changes and modifications on Watts products previously or subsequently sold.

25 3300 1497
*Estimated in lbs.

M500 / M1500 Full Port Ductile Iron Dual Chamber Basic Valve
Flow Data - ACV M500 (Globe) / M1500 (Angle)
Valve Size - Inches
Maximum Continuous
Flow Rate Gpm (Water)
Maximum Intermittent
Flow Rate Gpm (Water)
CV Factor GPM (Globe)
CV Factor GPM (Angle)

2-1/2

10

12

14

16

210

300

485

800

1850

3100

5000

7000

8500

11100

265

390

590

1000

2300

4000

6250

8900

10800

14100

45

75

100

175

490

770

1200

1750

2125

2890

57

91

125

215

571

990

1530

2525

2885

3575
Estimated

12
14
16

10

12
14
16

10

2-1

/2

Globe

Angle

Headloss

2-1
/2
3

Maximum continuous flow based on velocity of 20 ft. per second.


Maximum intermittent flow based on velocity of 25 ft. per second.
The Cv Factor of a value is the flow rate in US GPM at 60F that will cause a 1psi drop in pressure.
The factors stated are based upon a fully open valve.
Cv factor can be used in the following equations to determine Flow (Q) and Pressure Drop (P):
Q (Flow) = CvP
P (Pressure Drop) = (Q/Cv)2

100
80
60

40
30

Pressure Drop (psi)

20

10
8
6
4
3
2

8 10

20

40

60 80 100

200

500

1000

2000

5000

10000

20000

Flow Rate - Gallons per minute (Water)

Valve Cover Chamber Capacity


Valve Size - Inches

2-1/2

fluid oz.

10

10

22

70

U.S. Gal

10

12

14

16

1-1/4

2-1/2

6-1/2

9-1/2

Valve Travel
Valve Size - Inches

2-1/2

10

12

14

16

Travel - Inches

1/2

5/8

3/4

1-1/2

2-1/2

3-1/2

A Watts Water Technologies Company

ES-ACV-M500-M5100 1219

USA: Tel. (713) 943-0688 (713) 944-9445 www.watts.com

2012 Watts

You might also like