(MIN) STANDARD METER TUBE LENGTHS PER AGA/API 14.

3 - 2000
No Conditioner or Vane
Upstream lengths (UL) are based on the largest expected published I.D. for a given size and
rounded up to nearest inch at 44D. Downstream lengths exceed the minimum recommended
minimum length. All downstream lengths (DL) are complete with (2) each 1/2" and (1) 3/4"
threadolet or coupling, spaced 6 apart.
2 SECTION METER TUBES
SIZE
UL (44D)
DL (4.5D +24)
2
7'-10"
3'-0"
3
11'-4"
3'-6"
4
14'-13"
4'-0"
6
22'-4"
4'-6"
8
29-5
5'-0"
10
36-12
6'-0"
12
43-13
6'-6"
14
48-3
7'-0"
16
55-0
8'-0"
18
62-0
8'-6"
20
69-0
9'-6"
24
83-0
10'-8"
19 Tube Bundle LSV
Upstream lengths (UL) are based on the largest expected published I.D. for a given size and
rounded up to nearest inch at 29D. Downstream lengths exceed the minimum recommended
minimum length. All downstream lengths (DL) are complete with (2) each 1/2" and (1) 3/4"
threadolet or coupling, spaced 6 apart.
2 SECTION METER TUBES W/ VANES
SIZE
UPSTREAM
DOWNSTREAM
VANE LOCATION VL
2*
5'-0"
3'-0"
3
7'-5"
4'-0"
3'-8"
4
9'-9"
4'-0"
4'-10"
6
14'-8"
5'-0"
7'-1"
8
19'-8"
5'-0"
9'-6"
10
24'-10"
6'-0"
12'-0"
12**
29'-8"
7'-0"
13'-5-1/2" / 15'-2-1/2"
14**
32'-4"
8'-7"
14'-7-1/2" / 16'-8-1/2"
16**
37'-2"
9'-4"
18'-1-1/2" /20'-6-1/2"
18**
42'-0"
10'-1"
20'-5-1/2" / 23'-2-1/2"
20**
46'-7"
10'-11"
22'-8-1/2" / 25'-9-1/2"
24**
56'-3"
12'-7"
27'-4-1/2" / 31'-1-1/2"
*2" vanes are not available at this time, in any schedule. See Profiler for 2" sizes
**12" and larger have 2 setscrews. Numbers shown are to 1st, then to 2nd setscrew
2 section tubes
3 Section tubes

SIZE

2*
3
4
6
8
10
12
14
16
18
20
24

SIZE
2
3
4
6
8
10
12
14
16
18
20
24

3 SECTION METER TUBES WITH FLANGED TYPE VANES


INLET SPOOL
UPSTREAM SPOOL
DOWNSTREAM
including vane flange(s),
Flange face to orifice
LENGTH
3 gaskets and 1/2" spacer
plate centerline
plate Catalog "S"
Catalog "U"
5'-0"
2'-3"
2'-9"
3'-0"
7'-5"
3'-5"
4'-0"
4'-0"
9'-9"
4'-6"
5'-3"
4'-0"
14'-8"
7'-1"
7'-7"
5'-0"
19'-8"
9'-6"
10'-2"
5'-0"
24'-10"
12'-0"
12'-10"
6'-0"
29'-8"
14'-4"
15'-4"
7'-0"
32'-4"
15'-6"
16'-10"
8'-7"
37'-2"
17'-10"
19'-4"
9'-4"
42'-0"
20'-2"
21'-10"
10'-1"
46'-7"
22'-4"
24'-3"
10'-11"
56'-3"
27'-0"
29'-3"
12'-7"
*2" vanes are not available at this time, in any schedule. See Profiler for 2" sizes
UPSTEAM
LENGTH
TOTAL

UPSTEAM
LENGTH
TOTAL
3'-4"
4'-7"
6'-1"
8'-10"
11'-6"
14'-5"
17'-4"
18'-11"
19'-7"
24'-3"
26'-13"
32'-3"

3 SECTION METER TUBES WITH PROFILER


INLET SPOOL
UPSTREAM SPOOL
DOWNSTREAM
including 1/2" spacer
Flange face to orifice
LENGTH
plate (9.5D min)
plate centerline
1'-11"
1'-5"
3'-0"
2'-7"
2'-0"
4'-0"
3'-4"
2'-9"
4'-0"
4'-13"
3'-13"
5'-0"
6'-6"
5'-0"
5'-0"
8'-0"
6'-5"
6'-0"
9'-8"
7'-8"
7'-0"
10'-7"
8'-4"
8'-7"
12'-0"
9'-7"
9'-4"
13'-6"
10'-9"
10'-1"
15'-0"
11'-13"
10'-11"
18'-0"
14'-3"
12'-7"

Note: Minimum Length Upstream for TOL/HC is 36 from Profiler or Vane inlet.

(MIN) STANDARD METER TUBE LENGTHS PER AGA/API 14.3 - 2002


No Conditioner or Vane
Upstream lengths (UL) are based on the largest expected published I.D. for a given size and
rounded up to nearest inch at 44D. Downstream lengths exceed the minimum recommended
minimum length. All downstream lengths (DL) are complete with (2) each 1/2" and (1) 3/4"
threadolet or coupling, spaced 6 apart.
2 SECTION METER TUBES
SIZE
UL (44D)
DL (4.5D +24)
2
7'-10"
3'-0"
3
11'-4"
3'-6"
4
14'-13"
4'-0"
6
22'-4"
4'-6"
8
29-5
5'-0"
10
36-12
6'-0"
12
43-13
6'-6"
14
48-3
7'-0"
16
55-0
8'-0"
18
62-0
8'-6"
20
69-0
9'-6"
24
83-0
10'-8"
19 Tube Bundle LSV
Upstream lengths (UL) are based on the largest expected published I.D. for a given size and
rounded up to nearest inch at 29D. Downstream lengths exceed the minimum recommended
minimum length. All downstream lengths (DL) are complete with (2) each 1/2" and (1) 3/4"
threadolet or coupling, spaced 6 apart.
2 SECTION METER TUBES W/ VANES
SIZE
UPSTREAM
DOWNSTREAM
VANE LOCATION VL
2*
5'-0"
3'-0"
3
7'-5"
4'-0"
3'-8"
4
9'-9"
4'-0"
4'-10"
6
14'-8"
5'-0"
7'-1"
8
19'-8"
5'-0"
9'-6"
10
24'-10"
6'-0"
12'-0"
12**
29'-8"
7'-0"
13'-5-1/2" / 15'-2-1/2"
14**
32'-4"
8'-7"
14'-7-1/2" / 16'-8-1/2"
16**
37'-2"
9'-4"
18'-1-1/2" /20'-6-1/2"
18**
42'-0"
10'-1"
20'-5-1/2" / 23'-2-1/2"
20**
46'-7"
10'-11"
22'-8-1/2" / 25'-9-1/2"
24**
56'-3"
12'-7"
27'-4-1/2" / 31'-1-1/2"
*2" vanes are not available at this time, in any schedule. See Profiler for 2" sizes
**12" and larger have 2 setscrews. Numbers shown are to 1st, then to 2nd setscrew

SIZE

2*
3
4
6
8
10
12
14
16
18
20
24

SIZE
2
3
4
6
8
10
12
14
16
18
20
24

3 SECTION METER TUBES WITH FLANGED TYPE VANES


INLET SPOOL
UPSTREAM SPOOL
DOWNSTREAM
including vane flange(s),
Flange face to orifice
LENGTH
3 gaskets and 1/2" spacer
plate centerline
plate Catalog "S"
Catalog "U"
5'-0"
2'-3"
2'-9"
3'-0"
7'-5"
3'-5"
4'-0"
4'-0"
9'-9"
4'-6"
5'-3"
4'-0"
14'-8"
7'-1"
7'-7"
5'-0"
19'-8"
9'-6"
10'-2"
5'-0"
24'-10"
12'-0"
12'-10"
6'-0"
29'-8"
14'-4"
15'-4"
7'-0"
32'-4"
15'-6"
16'-10"
8'-7"
37'-2"
17'-10"
19'-4"
9'-4"
42'-0"
20'-2"
21'-10"
10'-1"
46'-7"
22'-4"
24'-3"
10'-11"
56'-3"
27'-0"
29'-3"
12'-7"
*2" vanes are not available at this time, in any schedule. See Profiler for 2" sizes
UPSTEAM
LENGTH
TOTAL

UPSTEAM
LENGTH
TOTAL
3'-4"
4'-7"
6'-1"
8'-10"
11'-6"
14'-5"
17'-4"
18'-11"
19'-7"
24'-3"
26'-13"
32'-3"

3 SECTION METER TUBES WITH PROFILER


INLET SPOOL
UPSTREAM SPOOL
DOWNSTREAM
including 1/2" spacer
Flange face to orifice
LENGTH
plate (9.5D min)
plate centerline
1'-11"
1'-5"
3'-0"
2'-7"
2'-0"
4'-0"
3'-4"
2'-9"
4'-0"
4'-13"
3'-13"
5'-0"
6'-6"
5'-0"
5'-0"
8'-0"
6'-5"
6'-0"
9'-8"
7'-8"
7'-0"
10'-7"
8'-4"
8'-7"
12'-0"
9'-7"
9'-4"
13'-6"
10'-9"
10'-1"
15'-0"
11'-13"
10'-11"
18'-0"
14'-3"
12'-7"

Note: Minimum Length Upstream for TOL/HC is 36 from Profiler or Vane inlet.