You are on page 1of 15

Guide

for remote configuring the new installed non-configured PTN

Metro Ethernet Test Dept 2009-6-10

Preparation

1software toolsT2000Navigator 2Gateway NEGNEcan be managed by T2000 and Navigator; 3new NE has physically connected to the PTN network and the DCN communication between the GNE and the NE is OK; 4BarCode information of the main control boardSCA/CXP of the new NE has sent back from the sites.

Collect NE information

1collect information from site


Take 2 photos in the site when installnation was finished, one is the whole view for the NE, the other is the BarCode View for the SCA/CXP board;

Attention:
to make sure the the SCA/CXP on PTN can be seen clearly in the photo, the photo pattern should be as follow:

PTN3900 Whole View

PTN 3900SCA Board BarCode View

PTN1900 Whole View

PTN1900 CXP Board BarCode View

PTN950 Whole View

PTN950 CXP Board BarCode View

PTN910 Whole View

PTN910 CXP Board BarCode View

PTN912 Whole ViewFor PTN912 CXP Board BarCode Viewplease refer to PTN 910

2BarCode Information Table


Record the BarCode of SCA/CXP board and site information in the BarCode Information Table as follow;(For the condition of two SCA/CXP, record the barcode information of both the working and backup SCA/CXP )

Remote configure NE data in office

1Use GNE IP to search new NE.

1open T2000, in the main manu click the 2select

menu;

command to open search for NE page;

3click the

button to open Input Search Domain window;

4select IP Address of GNE 5 input the GNE IP in the Search Address; 6then select OK; 7press to start NE search;

when the search for new NE is finished or stop 8select the uncreated NE, and change the GNE ID to the local GNE ID; 9press button to creat the new NE

10User Name:root; Password:password; then press OK;

There is prompt window to indicate the NE has been created.

The new NE will appear in the main topology with NE-ID.

2Using Navigator to make the NE change to working state;


2.1 Open Navigator software

Double click

to open Navigator software;

2.2 connect to and login Gateway NE

N gat or. exe avi

1Enter the IP of the Gateway NE to the NE IP Address, then click the connect to the Gateway NE;

button to

2Choose the Force Login , then click the

button to log in Gateway NE.

Username for logging in NE is szhw, and password is nesoft.

2.3 login non Gateway NE


1Click the Login button to show the login interface;

2Enter the NE ID of the non Gateway NE, choose the Force Login, then click the button to log in Gateway NE.

2.4 run command in navigator


Enter command:cfg-verify in the command input windows and get result from the result output windows

After this step, We can enter the command (:cfg-get-nestate) in the command input windows, If the result that displays in the result output windows isNE-STATE:running,then it means the NE is in running state.

3upload NE data and query board manufacturer information


3.1 Upload NE data
1Double click the new created NE in the main topology 2in the pup-up window, press to start NE data upload

3in the confirm window, press

button to start upload NE data

4press

button in the operation result prompt window to finish NE data upload

3.2 query board manufacturer information

M anuf act ure_Repor t . exe

1click 2then choose

in the main menu

3Choose the board of the NE to be query in the NE management tree, 4then press window, 5then press to get the report; to make the board to the Board Manufatureer Information Report

6recoard this BarCode and use this BarCode to find out the site name from the BarCode Information Table.

4change NE IP and NE IDT2000


4.1 change communication parameter

1right click the NE in the main topology ,then choose

to open NE explorer;

2enter Communication Parameter page In the left side of the NE Explorer, click the Function Tree, then choose

3change the Subnet Mask Enter new subnet mask according to LLD design then press 4change the IP Enter new IP according to the LLD design, then press 5press successfully. ;

to check and make sure the communication parameter is changed

4.2 change NE ID

1Right click the new created NE in the main topology, and select

2in the pop-up window, click

button;

3change the NE ID and Extended ID according to the LLD design, then press

After this operation, waiting for 10 seconds then turn to step 5;

5delete and creat the NE again


5.1 delete NE from the main topology

1right click on the new NE in the main topology and choose

to delete the NE;

2press

button to complete NE delete;

5.2 creat the NE again follow step 1 5.3 Upload NE datafollow step 3.1