in temperature in distillation column Pipe burst. Consequences Action -Install pipe that have high temperature and pressure limit. -Install temperature indicator/controller -Install high temperature alarm -Install pressure indicator/controller -Install high pressure alarm - Install temperature indicator/controller -Install low temperature alarm -Install pressure indicator/controller -Install low pressure alarm
Low
Low pressure
Less Less feed ( -Pump failure flow -Pipe blockage -Pipe leakage -Less fluid passing through 101-E in -lower speed -Longer contact time with heating fluid at 101-E result in higher temperature of output fluid -Waste of material -Drop in pressure of the feed in pipeline -Level in reactor drop and temperature increase -101-E overheated
-101-E damage
alarm -Install low pressure alarm -Install high temperature alarm in 101-R -Install pressure gauge for monitoring purpose -Install high pressure alarm in 101-R
None
No feed flow
-101-E overheated -101-E damage -Pressure build up at output of 101-E causing pipe burst -Pressure build up in 101-E due to the blockage, causing explosion No reaction at reactor -Level of fluid in 101-R decrease -Efficiency decrease -Mixing of back flow reacted product with reactants
Reverse
-Install a control valve to prevent reverse flow of fluid -Install low level indicator in 101-R