- Mounted on 35 mm " rail or 4 mm screw fixing. - Screws in open ready-to-tighten position. Control circuit Type of Auxiliary connection contacts
Basic reference. Complete with code indicating control circuit voltage (2) N/C 1 2 1 2 1 2 1 2 1 2 1 2
Weight
Supply a.c.
Consumption 4.5 VA Screw clamp Faston 1 x 6.35 or 2 x 2.8 Solder pins for printed circuit board Screw clamp Faston 1 x 6.35 or 2 x 2.8 Solder pins for printed circuit board N/O 4 3 2 4 3 2 4 3 2 4 3 2 4 3 2 4 3 2 CA2-KN40ii CA2-KN31ii CA2-KN22ii CA2-KN407ii CA2-KN317ii CA2-KN227ii CA2-KN405ii CA2-KN315ii CA2-KN225ii CA3-KN40ii CA3-KN31ii CA3-KN22ii CA3-KN407ii CA3-KN317ii CA3-KN227ii CA3-KN405ii CA3-KN315ii CA3-KN225ii kg 0.180 0.180 0.180 0.180 0.180 0.180 0.210 0.210 0.210 0.225 0.225 0.225 0.225 0.225 0.225 0.255 0.255 0.255
d.c. CA2-KN40ii
2.4 W
CA3-KN407ii
4x4
A1
50
58
50
45
58
31
57
35 45
10x1,3
A2
1/170
Te
53
N/C 2 1 1 2 3 4 LA1-KN20 LA1-KN02 LA1-KN11 LA1-KN40 LA1-KN31 LA1-KN22 LA1-KN13 LA1-KN04 (1) (2) (3) (3) (3) (4) (5)
kg 0.045 0.045 0.045 0.045 0.045 0.045 0.045 0.045 0.045 0.045 0.045 0.045 0.045 0.045 0.045 0.045
2 LA1-KN207 2 LA1-KN027 1 1 LA1-KN117 4 LA1-KN407 3 1 LA1-KN317 2 2 LA1-KN227 1 3 LA1-KN137 4 LA1-KN047 be used on control relays : CA4-KN22, CA4-KN31. be used on control relays : CA4-KN22. be used on control relays : CA4-KNiiiii. be used on control relays : CA3-KN22, CA4-KNiiiii. be used on control relays : CA3-KN22, CA3-KN31, CA4-KNiiiii.
Clip-on front mounting, 1 block per mini control relay Voltage Type Timing Composition range
Reference
Weight
kg 0.040 0.040
1...30 1...30
34
38
58
34
57
Te
1/171
Unit reference
Weight kg
LA4-Kiii
c and a 5 LA4-KE1B 0.010 12...24 V c and a 5 LA4-KE1E 0.010 32...48 V c and a 5 LA4-KE1FC 0.010 50...129 V c and a 5 LA4-KE1UG 0.010 130...250 V Diode a 5 LA4-KC1B 0.010 + Zener diode (2) 12...24 V a 5 LA4-KC1E 0.010 32...48 V RC (3) c 5 LA4-KA1U 0.010 220...250 V (1) Protection by limitation of the transient voltage to 2 Uc max. Maximum reduction of transient voltage peaks. Slight time delay on drop-out (1.1 to 1.5 times the normal time). (2) No overvoltage or oscillation frequency. Polarised component. Slight time delay on drop-out (1.1 to 1.5 times the normal time). (3) Protection by limitation of the transient voltage to 3 Uc max. and limitation of the oscillation frequency. Slight time delay on drop-out (1.2 to 2 times the normal time). Clips onto front of relay with locating device.
25
22
22
57
1/172
Te
58
Mounting accessories
Description Application Sold in lots of Clip-on fixing 1 Unit reference LA9-D973 Weight kg 0.025
Mounting plates
On 1 ' rail
On 2 ' rails
10
DX1-AP25
0.065
LA9-D973
Marking accessories
Description Application Sold in lots of 100 Unit reference LA9-D90 Weight kg 0.001
Marker holder
Clip-on fixing
Clip-in markers
25
AB1-Ri
(1)
0.002
25
AB1-Gi
(1)
0.002
DX1-AP25
DZ5-ME5
120
50
57
21
35 45
57
57
27
45
Te
110
1/173
Control relays
CA2-D and CA3-D Control circuit : a.c. References
1
Instantaneous
Number of contacts
Composition
Basic reference. Complete with code indicating control circuit voltage (2) CA2-DN40ii CA2-DN31ii CA2-DN22ii CA2-DC22ii
Weight
kg 4 4 3 1 2 2 2 2 including 1 N/O and 1 N/C make before break 2 2 0.320 0.320 0.320 0.320
CA2-DK22ii
0.580
CA2-DN31ii
TH as standard On 35 mm " rail or 4 mm screw fixing By screw clamp terminals Protected against direct finger contact with ready-to-tighten captive screws (1) Marking and contact positions conforming to CENELEC EN 50005, EN 50011. (1) Telemecanique patented system which prevents screws from tightening themselves (e.g. due to vibration during transport). (2) Standard control circuit voltages (for other voltages, please consult your Regional customer centre). Volts c 24 42 48 110 220/230 230 240 380/400 400 415 440 500 660 50 Hz B5 D5 E5 F5 M5 P5 U5 Q5 V5 N5 R5 S5 Y5 60 Hz B6 E6 F6 M6 U6 Q6 N6 R6 50/60 Hz B7 D7 E7 F7 M7 P7 U7 Q7 V7 N7 R7
CA2-DN, DC
44 LA4
105 (3) (DM,DR,DW,DL)
97 (3) (DF,DT)
77 (DA1,DE1)
50/60
12,5 (LA8)
45
12,5 (LA8)
c =
34 35
80
(1) + 4 mm with lead sealing kit LA9-D901 (2) With 2 or 4 contacts (3) With or without combined use of coil suppressor module : LA4-DA1i, DE1i CA2-DK22
44 LA4
44 LA4
CA2DN DC DK c 80 80 90 (1) 2 elongated holes 4.5 x 9 CA2, CA3-DN, DC, DK Mounting on rail AM1-DP200 or DE200
CA3DN 115
DC 115
=
= DK 125 DK 127 134
97 (3) (DF,DT)
77 (DA1,DE1)
74
12,5 (LA8)
91
12,5 (LA8)
74
45
91
(1) + 4 mm with lead sealing kit LA9-D901 (2) With 2 or 4 contacts (3) With or without combined use of coil suppressor module LA4-DA1i, DE1i 1/174
c (AM1-DP200) c (AM1-DE200)
CA2DN 82 89
DC 82 89
DK 91 98
DC 117 124
Te
50/60
74
48
Control relays
CA2-D and CA3-D Control circuit : d.c. References
1
kg 0.320 0.320 0.320 0.320
Instantaneous
CA3-DK22ii
0.580
TH as standard On 35 mm " rail or 4 mm screw fixing By screw clamp terminals Protected against direct finger contact with ready-to-tighten captive screws (1) Marking and contact positions conforming to CENELEC EN 50005, EN 50011. (1) Telemecanique patented system which prevents screws from tightening themselves (e.g. due to vibration during transport). (2) Standard control circuit voltages (for other voltages, please consult your Regional customer centre). Volts a 12 24 36 48 60 72 110 125 220 250 440 U from 0.8 to 1.1 Uc JD BD CD ED ND SD FD GD MD UD RD U from 0.7 to 1.25 Uc JW BW CW EW SW FW MW CA3-DN31ii
CA3-DN, CA3-DC
44 LA4
105 (3) (DM,DL)
AF1-EA4
AF1-EA4
97 (3) (DF,DT)
77(DC1,DE1)
50
74
12,5 (LA8)
45
12,5 (LA8)
35
80
(1) + 4 mm with lead sealing kit LA9-D901 (2) With 2 or 4 contacts (3) With or without combined use of coil suppressor module LA4-DC1i, DE1i CA3-DK22
CA2DN 80
DC 80
DK 90
CA3DN 115
DC 115
DK 125
74
12,5 (LA8)
91
12,5 (LA8)
94 100
70
45
(1) + 4 mm with lead sealing kit LA9-D901 (2) With 2 or 4 contacts (3) With or without combined use of coil suppressor module LA4-DC1i, DE1i
Te
1/175
50
1
LA4-DT q U LA4-DR q U (1)
LA4-DF
LA4-DL
LA4-DWB (1)
LA4-DE1 LA1-DN, DC
LA1-DX, DZ
LA4-DC1U (2)
LA1-DY
LA2-DT, DS LA3-DR
LA6-DK
LA8-DN
LA8-DN
(1) For use on CA2-DN only. (2) For use on CA3-DN only. 1/176
LA4-DV
Te
Control relays
CA2 and CA3-D Add-on auxiliary contact blocks and mechanical latch blocks
Illustrations : page 1/176 Dimensions : pages 1/174 and 1/175
References
1
kg 1 1 2 2 2 1 4 3 2 1 1 2 2 3 4 1 2 (3) LA1-DN11 LA8-DN11 LA1-DN20 LA8-DN20 LA1-DN02 LA1-DN22 LA1-DN13 LA1-DN40 LA1-DN04 LA1-DN31 LA1-DC22 0.030 0.030 0.030 0.030 0.030 0.050 0.050 0.050 0.050 0.050 0.050
Instantaneous auxiliary contact blocks (with dust and damp protected contacts)
For use in particularly harsh industrial environments Number Maximum number Composition of per relay (1) contacts Front mounting protected (4) 2 4 1 1 2 2 2 2 2 2 1 1 LA1-DX20 LA1-DY20 LA1-DZ40 LA1-DZ31 Reference Weight
Manual or 1 electric (1) Maximum mounting possibility (see below). Type Type For guaranteed of device of coil operation from CA2-D 50 or 60 Hz 50/60 Hz
0.81.1 Uc 1 + 2 0.81.1 Uc 1 or 2 0.851.1 Uc 1 + 2 CA3-D a 0.81.1 Uc 1 or 2 a (wide range) 0.71.25 Uc 1 or 2 (2) Standard control circuit voltages (for other voltages, please consult your Regional customer centre). Volts c or a 12 24 32/36 42/48 60/72 100 110/127 220/240 255/277 380/415 Code J B C E EN K F M U Q (3) Including 1 N/O and 1 N/C make before break. (4) Device fitted with 4 screening continuity terminals. (5) With extended scale from 0.1 to 0.6 s. (6) With switching time of 40 ms 15 ms between opening of the N/C contact and closing of the N/O contact (suitable for use with star-delta circuits).
Te
1/177
Control relays
CA2-D and CA3-D Interface, control modules and delayed capacitive opening devices
Illustrations : page 1/176 Dimensions : pages 1/174 and 1/175
References
1
LA4-DR0U
On-delay
Off-delay
CA2-D
Relay interface
LA4-DLE
Indicators
Type Clips into legend plate location on CA2-D, CA3-D Control relay supply voltage 12/72 V 72/250 V 250/440 V Sold in lots of 5 5 5 Unit reference LA4-DVE LA4-DVM LA4-DVR Weight kg 0.010 0.010 0.010
LA4-DMU
Red LED
Te
Control relays
CA2-D and CA3-D Coil suppressor modules and accessories
Illustrations : page 1/176 Dimensions : pages 1/174 and 1/175
References
Weight kg 0.001
LA9-D93
0.001
LA1-DN (2 contacts)
100
LA9-D90
0.001
LA9-D91
0.001
Reference LA9-D901
Weight kg 0.005
(1) An RC circuit provides effective protection for circuits highly sensitive to high frequency interference. Voltage limited to 3 Uc maximum, oscillating frequency limited to 400 Hz maximum. Slight increase in drop-out time (1.2 to 2 times the usual time). (2) For satisfactory protection, a suppressor module must be fitted across the coil of each control relay. (3) Protection is provided by limiting the transient voltage value to 2 Uc maximum. Maximum reduction of transient voltage peaks. Slight increase in drop-out time (1.1 to 1.5 times the usual time). (4) Protection is provided by a polarised component; no overvoltage or oscillating frequency. Slight increase in drop-out time (6 to 10 times the usual time).
Te
1/179
Control relays
Coils for CA2-D, a.c. control supply
References
c
Inductance of closed circuit H 50 Hz Reference (1) Average resistance at 20 C 10 % Inductance of closed circuit H 60 Hz 4.98 5.45 22.09 116.6 139.2 417.8 490.2 587.4 781.5 1486 1826 1892 2304 3482 3678 0.21 0.25 1.02 4.5 5.1 16.6 18.5 21 30 55 69 71 85 119 135 LX1-D2Z6 LX1-D2B6 LX1-D2E6 LX1-D2F6 LX1-D2G6 LX1-D2L6 LX1-D2M6 LX1-D2U6 LX1-D2W6 LX1-D2Q6 LX1-D2N6 LX1-D2R6 LX1-D2T6 LX1-D2S6 LX1-D2X6 0.070 0.070 0.070 0.070 0.070 0.070 0.070 0.070 0.070 0.070 0.070 0.070 0.070 0.070 0.070 0.070 0.070 0.070 0.070 0.070 0.070 0.070 0.070 0.070 0.070 Reference (1) Weight
Average resistance at 20 C 10 %
kg
LX1-D2ii
21 (2) 24 32 42 48 110 120 127 208 220 220/230 230 240 256 277 380 380/400 400 415 440 480 500 575 600 660
6.3 6.82 12.26 21.32 28.05 148.2 192.5 613.3 649.7 726.6 816 1848 2069 2219 2549 3285 5631
LX1-D2Z5 LX1-D2B5 LX1-D2C5 LX1-D2D5 LX1-D2E5 LX1-D2F5 LX1-D2G5 LX1-D2M5 LX1-D2P5 LX1-D2U5 LX1-D2W5 LX1-D2Q5 LX1-D2V5 LX1-D2N5 LX1-D2R5 LX1-D2S5 LX1-D2Y5
Specifications Average consumption at 20 C : - inrush (cos = 0.75) 50 Hz : 60 VA; 60 Hz : 70 VA, - sealed (cos = 0.3) 50 Hz : 7 VA; 60 Hz : 7.5 VA. Operating range ( 55 C) : 0.8 to 1.1 Uc
50/60 Hz 21 (2) 24 42 48 110 120 220/230 230 230/240 380/400 400 415 440 5.6 6.19 19.15 25 130 159 539 595 645 1580 1810 1938 2242 0.24 0.26 0.77 1 5.5 6.7 22 21 25 60 64 74 79 LX1-D2Z7 LX1-D2B7 LX1-D2D7 LX1-D2E7 LX1-D2F7 LX1-D2G7 LX1-D2M7 (3) LX1-D2P7 LX1-D2U7 (4) LX1-D2Q7 LX1-D2V7 LX1-D2N7 LX1-D2R7 0.070 0.070 0.070 0.070 0.070 0.070 0.070 0.070 0.070 0.070 0.070 0.070 0.070
Specifications Average consumption at 20 C : - inrush (cos = 0.75) 50/60 Hz : 70 VA at 50 Hz, - holding (cos = 0.3) 50/60 Hz : 8 VA at 60 Hz. Operating range ( 55 C) : 0.85 to 1.1 Uc (1) The last two digits in the reference represent the voltage code. (2) Voltage for special coils fitted in contactors with serial timer modules, with 24 V supply. (3) This coil can be used on 240 V at 60 Hz. (4) This coil can be used on 230/240 V at 50 Hz and on 240 V only at 60 Hz.
1/180
Te
Control relays
Coils for CA3-D, d.c. control supply
References
a
Average resistance at 20 C 10 % Inductance of closed circuit H Reference (1) Weight
kg
Standard coils
12 21 (2) 24 36 48 60 72 96 100 110 125 155 174 200 220 250 305 348 440 543 600 Specifications Average consumption at 20 C : 9 W Operating range ( 55 C) : 0.8 to 1.1 Uc 17 45.4 71 149.7 267 422 609 1049 1105 1411 1781 2763 3480 4280 5235 6433 9778 12 479 19 785 31 785 38 982 0.79 2.16 3.1 7.1 11.9 19 26 46 49.6 61.8 77.8 119 152 184 221 271 401 512 793 1261 1393 LX4-D2JD LX4-D2ZD LX4-D2BD LX4-D2CD LX4-D2ED LX4-D2ND LX4-D2SD LX4-D2DD LX4-D2KD LX4-D2FD LX4-D2GD LX4-D2PD LX4-D2QD LX4-D2LD LX4-D2MD LX4-D2UD LX4-D2TD LX4-D2VD LX4-D2RD LX4-D2WD LX4-D2XD 0.175 0.175 0.175 0.175 0.175 0.175 0.175 0.175 0.175 0.175 0.175 0.175 0.175 0.175 0.175 0.175 0.175 0.175 0.175 0.175 0.175
LX4-D2ii
Te
1/181