C20 2006-06-13 Page 1 of 1

For high bit rate DWDM systems in the Metro environment


General and application
Teralight Non-Zero Dispersion Shifted Fibre (NZDSF) has set the standard for high bit-rate, multi-wavelength transmission. Its unique optimization of effective area, chromatic dispersion and dispersion slope enables excellent distortion management, cost-effective operation at 10 and 40 Gbps, tight channel spacing in C and L bands, compatibility with future S band and provides full compliance with the new ITU G.656 recommendation. TeraLigth Metro is further optimized for metropolitan backbone applications. It supports 10 Gbps transmission without dispersion compensation for distances of about 200 km, resulting in cost savings compared to standard single mode fibre. For longer distances or 40 Gpbs operation, commercially available compensating devices can be used. The same fibre also supports short-length metro systems, providing additional cost savings.

Standards and Norms


IEC 60793-2-50 Category B4 EN 60793-2-50: Class B4 ITU Recommendation G.655.B ITU Recommendation G.655.C ITU Recommendation G. 656

Attenuation (of cable with fibres)


1310 nm 1550 nm 1625 nm 1383 nm Group index of refraction at 1310 nm Group index of refraction at 1550 nm Group index of refraction at 1625 nm 04 d / .3 Bk m 02 d / .8 Bk m 03 d / .1 Bk m 10d / . Bk m 1.4690 1.4692 1.4694

IEC 60793-1-40

Fibre properties according to IEC


Attribute Measurement method Mode field diameter @1550 nm IEC/EN 60793-1-20 Cladding diameter IEC/EN 60793-1-20 Cladding non-circularity IEC/EN 60793-1-20 Core (MFD) non-circularity IEC/EN 60793-1-20 Core (MDF) -cladding concentricity error IEC/EN 60793-1-20 Primary coating diameter - coloured IEC/EN 60793-1-21 Primary coating non-circularity IEC/EN 60793-1-21 Primary coating-cladding concentricity error IEC/EN 60793-1-21 Proof stress level IEC/EN 60793-1-30 Strip force (peak) IEC/EN 60793-1-32 Chromatic dispersion coefficient IEC/EN 60793-1-42 At 1440 nm In the interval 1530 nm 1565 nm Typical value at 1550 nm In the interval 1565 nm 1625 nm In the interval 1285 nm 1330 nm Macro bending loss at 1550 nm, 100 turns on a IEC/EN 60793-1-47 50 mm mandrel. PMDQ Link Design Value IEC/TR 61283-3 Units m m % % m m % m GPa N p/ m sm n k p/ m sm n k p/ m sm n k p/ m sm n k p/ m sm n k dB ps/m k

IEC 60793-1 Limits 9.2 0.5 125.0 1 . 1 0 6 . 0 6 250 15 6 2 1 .( 1 0 %) 7 1.3 p a.r . F ek t 8 si p 9 > 0.1 5.5 to 10.0 8 7.5 to 13.4 -10.0 to 3.0 . 05 0 . 08 0