Architectural Floodlights
CFL
Table of Contents Architectural Floodlights Floodlighting Application Optical Matrix Mechanical Highlights Product Information Important Features Beam Properties Product Structure Ordering Information Luminaire Specifications Fixture Option Specifications Mounting Option Specifications Beam Spread Charts References Cosine Table CFL 24-25 26 27 28-29 30 30 31-32 33 AFL10 36-37 38-39 40-41 42-45 46 47 48-52 53-55 AFL20 58-59 60-61 62-63 64-67 68 69 70-72 73-75 2-94 2-13 20 21 AFL30 78-79 80-81 82-83 84-87 88 89 90-92 93-94 258 259
pages 23-33
50 - 70 watt H.I.D. 13 - 42 watt Compact Fluorescent 60 watt Incandescent 150 watt Halogen CFL1 Wide Flood CFL6 Narrow Spot
AFL10
70 - 175 watt H.I.D. 500 watt Halogen AFL11 Wide Flood AFL12 Vertical Flood AFL13 Medium Flood AFL14 Narrow Flood AFL15 Spot AFL16 Narrow Spot AFL17 Horizontal Spot
pages 35-55
Photometrics See separate AFL Photometric Catalog in Photometric Section of Specification CD or on www.kimlighting.com.
AFL20
SITE / AREA PARKING STRUCTURE ROADWAY ARCHITECTURAL FLOOD ACCENT LANDSCAPE 16555 EAST GALE AVENUE CITY OF INDUSTRY, CA 91745 U.S. A. PHONE 626 / 968 - 5666 FAX 626 / 369 - 2695
ENTIRE CONTENTS
pages 57-75
250 - 400 watt H.I.D. AFL21 Wide Flood AFL22 Vertical Flood AFL23 Medium Flood AFL24 Narrow Flood AFL25 Spot AFL26 Narrow Spot AFL27 Horizontal Spot
AFL30
750 - 1000 watt H.I.D. AFL31 Wide Flood AFL32 Vertical Flood AFL33 Medium Flood AFL34 Narrow Flood AFL35 Spot AFL36 Narrow Spot AFL37 Horizontal Spot
pages 77-94
www.kimlighting.com
Glare Control
Barn Doors
Most effective when used with wide flood or medium flood distributions 0 to 20 lens shielding per panel (varies per model and top to side)
Wide Flood
Vertical Flood
Medium Flood
Narrow Flood
Spot
Narrow Spot
Horizontal Spot
Barn doors provide some control of lens visibility from the side of and slightly in front of the fixture. Adjustable panels provide a degree of customization to suit field conditions. Barns doors are not used for shaping light distributions.
Four Luminaire Sizes provide a range of the most compact fixture scale for the requisite lamp. From the smallest (CFL) in Incandescent, Halogen, Compact Fluorescent and H.I.D. lampings to 70 watt, to the largest (AFL30) in H.I.D. lampings up to 1000 watt.
Fixed Hoods
Most effective when used with narrow flood or spot distributions 25 lens shielding (varies per model and top to side)
Fixed hoods provide control of visibility from top or bottom views of the lens only, while producing no obstruction in the opposite direction. CFL Series AFL10 Series AFL20 Series AFL30 Series
Full Shields
Most effective when used with narrow flood or spot distributions where visibility is from all sides of the fixture 25 lens shielding (varies per model and top to side)
Accessories, controlling unwanted lamp visibility, protecting the luminaire from vandalism, or reducing spill light in tight spotlighting distributions, make fine-tuning luminaires to special applications requirements possible. See pages 3-5 for additional details.
Full shields will provide good control of lens visibility, as well as trimming of side light from the lens surface. Barn Doors Fixed Hood Full Shield Grid Louver Lexan Shield Color Filters
Grid Louvers
Limited to specific optical systems 35 lens shielding (varies per model and top to side)
Grid Louvers
Grid louvers include baffles inside a full shield. These additional components cut lens and reflector visibility considerably. However, grid louvers cannot be applied to all optical systems designs. Grid louver designs are matched to specific optical systems. The characteristics of the optical system dictate how many louvers can be used, and at what angle they must be placed.
Kim provides the widest range of Mounting Options to assure that each luminaire can be mounted rigidly, to preserve aiming and provide years of trouble-free service.
Grid louver vanes, specifically designed for narrow flood reflectors, are angled to prevent obstruction of reflector output. Junction Box Mounting Stanchion Mounting Horizontal Surface Mounting Wall / Vertical Surface Mounting 40 lens shielding (varies per model and top to side)
Side Pole Mounting Grid louvers for spot and narrow spot distributions utilize straight vanes and should not be used with other distributions.
KIM LIGHTING 3
NOTE: Refer to individual series information for specific option and accessory availability.
2 KIM LIGHTING
NOTE: The color samples shown are for comparison use only, and do not represent actual field conditions (impossible in a printed format.) Actual performance and colors will change based on lamp and reflector system used. Light Loss Factor (LLF) indicates approximate percentage of source lamp illuminance that is transmitted through the filter.
Color Filters
High Pressure Sodium
100 80 60 40 20 80% LLF
Metal Halide
80% LLF
The spectral distribution chart at left shows where Metal Halide lamp output is greatest. Note that its output in the red zone, above 600nm, is very weak. This means that this lamp will not render red color well, and will tend to tint whites to appear blue and bluegreen, as this is where the lamps greatest energy is produced.
450 500 550 600 650 700
400
450
500
550
600
650
700
400
450
500
550
600
650
700
Wavelength in nanometers
400
Metal Halide
65% LLF
60
The spectral distribution chart at left shows where High Pressure Sodium lamp output is greatest. Note that its output below 550nm is very weak. The strong output in the 560nm to 625nm range is what gives this lamp its characteristic yellow-orange color appearance. These lamps will not render blue surface colors well, and will tend to tint whites to a yellow-orange color appearance.
400
450
500
550
600
650
700
400
450
500
550
600
650
700
4% Transmittance 100 80 60
Metal Halide
2% LLF 100 80 60
3% LLF
Not Recommended
Color Filters
Color filters can be used to modify lamp coloration, or to add a dramatic color effect to a project. Color filters work simply by blocking some wavelengths of light, and transmitting others. Color filters cannot add color to the light passing through them. Therefore, when using color filters with H.I.D. sources, it is important to select an appropriate source, as it will have a dramatic impact on the appearance of the resulting light output. #15 Deep Straw
100 % Transmission 80 60 40 20 400 450 500 550 600 650 Wavelength in nanomometers 700
40
40 20 450 500 550 600 650 700 400 450 500 550 600 650 700
The color distribution shown for each filter is a representation of the amount of light transmitted at each wavelength. In this example; the filter will transmit approximately ( ) 2% of the light passing through it at 450nm, 80% at 550nm, and 90% at 650nm.
20 400
Metal Halide
4% LLF
Lamp spectral energy distribution will have a dramatic effect on the color transmitted by the color filter.
60 40 20
Not Recommended 40 20 450 500 550 600 650 700 400 450 500 550 600 650 700
Metal Halide
100 80 60 40 20 400 450 500 550 600
Metal Halide
400
400
Metal Halide
5% LLF 100 80 60
<2% LLF
60 40 60 20 40 40 20 450 500 550 600 650 700 400 450 500 550 600 650 700
5
400
450
500
550
600
650
700
400
20 400
Filter Characteristics
400
KIM LIGHTING
15 '
15 '
10 Fc
64
0c
/8
10'
5'
When a large area is to be illuminated, the use of multiple fixtures is required to produce satisfactory coverage of the target. By using complimentary optical designs in combination, virtually any surface can be illuminated uniformly, with no unwanted streaking or brightness patterns. NOTE: Dimensions shown are for illustrative purposes only.
25'
Beam Shape
In architectural floodlighting, the surfaces being illuminated are generally rectilinear in shape. Further, to create an efficient lighting system, waste light should be eliminated. This requires a range of beam patterns that allow control of illumination onto desired areas, while eliminating waste light, without resorting to cut-off baffles. By utilizing beam shapes that are more rectangular, and matched to the vertical and horizontal aspect ratio of the surface being lighted, a system can produce even illumination using fewer fixtures.
150'
Round Beam Shapes require several fixtures to cover the rectangular surface, producing an inefficient system that provides uneven surface illumination.
Optimized Beam Shapes, designed to illuminate the rectangular surface, require fewer fixtures, producing an efficient system that provides uniform surface illumination.
Symmetrical Distributions direct more light at the center, resulting in a system that is hindered by the effects of the Inverse Square and Cosine Laws to produce uneven surface illumination.
Optimized Distributions direct more light at higher angles, less light at the center and even less light at lower aiming angles, resulting in an optical system that overcomes the effects of the Inverse Square and Cosine Laws to produce uniform surface illumination.
Vertical Flood
Narrow Flood
Spot
Narrow Spot
KIM LIGHTING 7
KIM LIGHTING
Floodlighting Effects
Set Back Distance
The largest impact of set back distance is on how the surface details of the target will be modeled. The availability of a wide range of complementary optical systems means that the appropriate set back distance can be used to achieve desired shadowing and surface appearance.
Floodlighting Effects
Flat Lighting
Flat lighting produces a surface that is uniformly illuminated and renders minimal surface texture and shadowing from surface relief. To achieve the best results, maximize set back distances and keep aiming angles to a minimum. For large surfaces, increase pattern overlap to reduce shadowing effects and maintain a Uniformity Ratio of between 3:1 to 4:1. Watch out for window locations, as this effect can produce offensive glare to building occupants. Additionally, reflected glare from luminaires may be visible in windows located at the same elevation as the observer. Single Fixtures Multiple Fixtures
Wide Shadows
32
3xH Maximize Set Back Distances and minimize aiming angles. Maximize Pattern Overlap to attain a 3:1 Uniformity Ratio.
Medium Shadows
20
Surface Modeling
Surface modeling produces subtle to dramatic modeling of surface detail and texture. For surfaces with deep relief, increase set back distances. Use moderate lateral fixture spacings to control crosslighting. For large surfaces, use moderate spacings between fixtures to attain a uniformity ratio of between 5:1 and 7:1. Watch out for window locations, as this effect can produce offensive glare to building occupants. Single Fixtures Multiple Fixtures
1-2 x H Narrow Shadows Decreasing Set Back Distances will produce deeper shadowing effects. Utilize moderate fixture spacing to control cross-lighting and attain a minimum 6:1 Uniformity Ratio.
10
Surface Texturing
Deep Set Back
Spot (more than 3X surface height)
Pattern Overlap
Increasing the overlap between adjacent beam patterns will reduce the contrast between illuminated areas and shadowing. However, shadow width will not be reduced, as this is a function of set back distance.
Darkest Shadow at end Medium Shadow Lightest Shadows in center Medium Shadow Darkest Shadow at end
Wide Shadows
Grazing is used when the desired effect is to dramatically accentuate surface texture and detail. Grazing is accomplished by placing fixtures very close to the surface to be lighted and utilizing very high aiming angles. Kim Horizontal Spot reflectors are specifically designed for this application. To soften the effect, increase set back distances slightly. For large areas, use moderate spacings between fixtures to attain a uniformity ratio of between 5:1 and 7:1. Watch out for deep reliefs and surface detailing, which can create undesirable shadows on the building surface. Consider using fixed hoods to reduce visibility of the fixture lens(es).
Single Fixtures
Multiple Fixtures
Minimize Set Back Distances and maximize aiming angles. The closer the fixtures are to the surface, the greater the surface texture will be accentuated
Utilize moderate fixture spacing to control cross-lighting and attain a minimum 6:1 Uniformity Ratio.
No Shadow
8 KIM LIGHTING
Application Guide
Building Features Narrow Spot, Horizontal Spot Facades Wide Flood, Vertical Flood Signs Vertical Flood Ceilings Wide Flood Facades Narrow Spot, Horizontal Spot
Parking Lots Wide Flood, Vertical Flood Building Focal Point Spot, Narrow Spot
Trees Spot Narrow Flood Narrow Spot Fountains Spot, Narrow Spot Atriums Narrow Flood, Narrow Spot
KIM LIGHTING 11
Specifically designed to illuminate architectural facias and create dramatic surface effects.
Up Lighting
The Horizontal Spot reflector projects an intense sheet of light up the wall for highlighting reliefs, projections and surface textures. This effect is called Wall Grazing. Wall grazing should not be confused with facade lighting, which is normally produced by floodlights set back from the wall. Wall grazing will light the wall to a limited degree, but its real purpose is to create surface feature highlights rather than uniform wall washing.
The Horizontal Spot optical system is based on the Wall Grazer Optics available in the Wall Director Series (see separate catalog). This unique distribution is ideal for creating dramatic highlighting effects when mounted very close to building surfaces.
12
KIM LIGHTING
KIM LIGHTING
13
AFL10 Series
with Horizontal Flood optics located in architectural recess to illuminate the roof parapet and facade reveal.
14
KIM LIGHTING
KIM LIGHTING
15
AFL20 Series
Ground mounted with Vertical Flood optics to illuminate building facade.
16
KIM LIGHTING
KIM LIGHTING
17
AFL20 Series
with various optics and color filters to illuminate signage and roof-top features.
18
KIM LIGHTING
KIM LIGHTING
19
Optical Matrix
This page reflects Kims recommendations regarding the optimum optical system / accessory combinations throughout the Kim Floodlighting Family.
Mechanical Highlights
Series
Vertical Flood
Medium Flood
Narrow Flood
Spot
Horizontal Spot
Locking Stop Arm prevents lens frame from swinging free during re-lamping.
Unitized Reflector assembly in Specular Alzak. Interchangeable with seven beam spreads available.
Lamp Types Available in Metal Halide, High Pressure Sodium, Fluorescent, and Halogen lamping.
CFL
Lamping 50 - 70 watt H.I.D. 13 - 42 watt Fluorescent 60 watt Incandescent 150 watt Halogen Fixture Options Barn Doors Fixed Hood Full Shield
AFL10
Lamping 70 - 175 watt H.I.D. 500 watt Halogen Fixture Options Barn Doors Fixed Hood Full Shield Lexan Shield Grid Louver Color Filter Assembly
AFL11
AFL12
AFL13
AFL20
Lamping 250 - 400 watt H.I.D. Fixture Options Barn Doors Fixed Hood Full Shield Lexan Shield Grid Louver Color Filter Assembly
AFL21
AFL22
AFL23
AFL30
Lamping 750 - 1000 watt H.I.D. Fixture Options Barn Doors Fixed Hood Full Shield Grid Louver
AFL31
AFL32
AFL33
Die-cast aluminum door frame mates to housing, forming a continuous cylindrical shape. Secured with captive stainless steel screws
Tempered glass lens is sealed to door frame by a one-piece molded silicone gasket.
Heavy die-cast aluminum swivel (EXCEPT AFL30) utilizes interlocking adjustment teeth to lock-in aiming.
Precision die-cast housing with integral cooling ribs that dissipate heat.
20
KIM LIGHTING
KIM LIGHTING
21
CFL Series
with various optics to illuminate landscape and specimen trees.
CFL
COMPACT FLOODLIGHTS 50 - 70 WATT H.I.D. 13 - 42 WATT FLUORESCENT 60 - 150 WATT INCANDESCENT / HALOGEN
22
KIM LIGHTING
KIM LIGHTING
23
CFL
CFL1
Optical Control
The CFL Series has a variety of optical accessories to control glare and increase the visual effectiveness of the lighting scheme. Shielding devices are carefully engineered to prevent shadows and preserve beam efficiency while reducing undesirable transient brightness. Barn Doors are a familiar accessory that allow for field-adjustable glare shielding. The Fixed Hood is a moderate shielding device and the Full Shield is a complete shielding device. Both are ideally suited for applications close to walkways, driveways, or roadways. See page 30 for details.
BD-CFL Barn Doors FH-CFL Fixed Hood FS-CFL Full Shield
CFL6
24
KIM LIGHTING
KIM LIGHTING
25
BD-CFL
Barn Doors for all models page 30 Main Beam 50% NOTE: CFL6 beam is rendered at K scale to the CFL1 Series distribution shown.
FH-CFL
Fixed Hood for all models page 30
FS-CFL
Full Shield for all models page 30
50%
50%
50%
Main Beam
JBR
Architectural Junction Box page 31
J-27N
Surface Mount page 31
JW
JB1 J-25N
Portable Spear Mount page 32
JBR30 or JBR32
In-grade Staked Architectural Junction Box page 31
EP17 PowerPostTM
page 32
SM18
Stanchion Mount page 31
By others
26
KIM LIGHTING
KIM LIGHTING
27
CFL
13 to 150 Watt
Mounting Options
9 Stanchion Mount:
Cat. No.:
SM18
FH-CFL/WH-P
4-6
SM18/WH-P
7-14
3" O.D. by .188" wall cast low copper aluminum with K" NPSM fixture mount and hand hole with flush cover. Internal set screw fixture lock accessible through hand hole. Internal ground lug supplied with installed lead.
1 Fixture:
Cat. No. designates CFL fixture and beam pattern. Single fixture EPA: 0.3 (45 tilt) 0.5 (Face on) Beam Pattern: Cat. No.: Wide Flood CFL1 50HPS120 50HPS277 50MH120 50MH277 13PL120 13PL277 60INC120 150HAL120 NOTE: 42PL operates 26, 32, and 42 watt lamps at 120 thru 277 volts (50-60 Hz). Color: Cat. No.: Black BL-P Dark Bronze DB-P Light Gray LG-P Platinum Silver PS-P White WH-P Custom Colors CC-P Consult representative for custom colors. 70HPS120 70HPS277 70MH120 70MH277 42PL Narrow Spot CFL6 50HPS120 50HPS277 50MH120 50MH277 60INC120 150HAL120 70HPS120 70HPS277 70MH120 70MH277
10 Surface Mount:
Cat. No.:
J-27N
Cast low copper aluminum with mounting ears for wood screw attachment to tree or wood structure. 5.5 cu in. splice compartment with gasketed cover. K" NPSM fixture mount and K" NPSM conduit or cord seal entry. NOTE: Surface mount can be connected to conduit or outdoor cord with a waterproof cord seal (by others).
11 Architectural Wall
Mount:
Cat. No.:
JW
2 Electrical Module:
HPS = High Pressure Sodium MH = Metal Halide PL = Compact Fluorescent INC = Incandescent HAL = Halogen See lamp and electrical data on pages 96-98 for ballast types and characteristics.
Die-cast low copper aluminum with K" NPSM fixture mount. Internal set screw provided for locking position. Canopy attaches to stainless steel wall plate for mounting to any standard electrical outlet box. PVC fixture molded in black with K" NPT mount is corrosion free and UV resistant. Replaces EMT, conduit connectors and weatherproof boxes. 100% shatter resistant against denting and cracking. Angled bottom to eliminate cable congestion. NOTE: Should be used with a UL listed fixture and grounding means (i.e., third wire) suitable for use in wet locations.
12 PowerPost by
Engineered Products Co.:
13 Architectural Junction
Box:
Cat. No.:
JB1
3 Finish:
Super TGIC powder coat paint over chromate conversion coating.
Die-cast low copper anodized aluminum cylindrical body and matching cover with K" NPSM fixture mount. One piece molded silicone cover gasket. Captive countersunk cover screws. Internal set screw provided for locking position. Two K" NPSM in bottom, 17 cu in. internal volume. CAUTION: Junction Box must be installed high enough to avoid contact with soil or standing water.
Cat. No.:
BD-CFL
Extruded aluminum, fully adjustable. Provides beam and glare control. CAUTION: Not recommended for ground mounted fixtures in vandal prone areas.
Cat. No.:
J-25N
Cast iron with K" NPSM fixture mount. Hot dip galvanized finish. 5.5 cu in. splice compartment. NOTE: For use with incandescent, halogen, and fluorescent fixtures only.
Cat. No.:
FH-CFL
Formed .062 thick aluminum. Provides moderate shielding for glare control.
Formed .062 thick aluminum. Provides complete shielding for glare control. CAUTION: Do not use in locations where leaves and trash can collect inside shield. Die-cast brass with K" NPSM fixture mount and die-cast cover. Internal set screw provided for locking position. 21 cu in. internal volume. NOTE: All side taps provided with plugs. Die-cast brass with K" NPSM fixture mount and die-cast cover. Internal set screw provided for locking position. 21 cu in. internal volume. NOTE: JBR32 for use with incandescent, halogen, and fluorescent fixtures only.
7 Brass In-grade
Architectural Junction Box:
Cat. No.: JBR-2 JBR-3 JBR-21 JBR-24 Cat. No.: JBR30 JBR32 (2) K" NPT in bottom, (2) 19" long stakes (2) K" NPT in bottom, 9' (SJTW-A) 3 wire cord and plug (2) K" NPT in bottom (2) L" NPT in bottom (2) K" NPT in sides, (2) K" NPT in bottom (4) K" NPT in sides, (2) K" NPT in bottom
28
KIM LIGHTING
KIM LIGHTING
29
CFL
Ordered separately from fixture. See pages 28-29 for complete ordering information.
Brass In-grade Architectural Junction Box (JBR-2, JBR-3, JBR-21, JBR-24): Die-cast brass with K" NPSM fixture mount and die-cast cover. Internal set screw provided for locking position. 21 cu in. internal volume. 25 Year Limited Warranty: Solid brass Junction Boxes are warranted for 25 years, from date of sale, against manufacturing defects and failure due to corrosion. Application Notes Creates a flush-mounted appearance. May be cast in concrete for increased stability. CAUTION: Fixture stem and swivel must not contact soil or standing water. Provide drainage away from Junction Box. Brass In-grade Staked Architectural Junction Box (JBR30, JBR32): Die-cast brass with K" NPSM fixture mount and die-cast cover. Internal set screw provided for locking position. 21 cu in. internal volume. (JBR32) 9' (SJTW-A) 3 wire cord and plug 25 Year Limited Warranty: Solid brass Junction Boxes are warranted for 25 years, from date of sale, against manufacturing defects and failure due to corrosion. Application Notes Creates a flush-mounted appearance. May be cast in concrete for increased stability. CAUTION: Fixture stem and swivel must not contact soil or standing water. Provide drainage away from Junction Box.
3L" DIA. K" NPSM Fixture Mount K" 3" 6" MIN. 12" MAX. 15E"
2J"
AIMING RANGE
Stanchion Mount (SM18): 3" O.D. by .188" wall cast low copper aluminum with K" NPSM fixture mount and hand hole with flush cover. Internal set screw fixture lock accessible through hand hole. Internal ground lug supplied with installed lead.
Ordered separately from fixture. See page 28-29 for complete ordering information.
Barn Doors (BD-CFL): Extruded aluminum, fully adjustable doors with anti-reflection baffles. Individually swiveled and secured on a stainless steel frame. Easily attaches to pre-drilled holes in the lens frame with stainless steel screws. Provides beam and glare control. Surface Mount (J-27N): Cast low copper aluminum with mounting ears for wood screw attachment to tree or wood structure. 5.5 cu in. splice compartment with gasketed cover. K" NPSM fixture mount and K" NPSM conduit or cord seal entry. NOTE: Surface mount can be connected to conduit or outdoor cord with a waterproof cord seal (by others).
3K" 4C"
10G"
Fixed Hood (FH-CFL): Formed .062 thick aluminum. Easily attaches to pre-drilled holes in the lens frame with stainless steel screws. Provides moderate shielding for glare control.
2F" K" NPSM Fixture Mount K" NPSM Conduit Entry 1L" 4K"
3K" 4C"
10G"
Full Shield (FS-CFL): Formed .062 thick aluminum. Easily attaches to pre-drilled holes in the lens frame with stainless steel screws. Provides complete shielding for glare control.
30
KIM LIGHTING
KIM LIGHTING
31
CFL
Ordered separately from fixture. See pages 28-29 for complete ordering information.
Architectural Wall Mount (JW): Die-cast low copper aluminum with K" NPSM fixture mount. Internal set screw provided for locking position. Canopy attaches to stainless steel wall plate for mounting to any standard electrical outlet box.
Lamp HIGH PRESSURE SODIUM 50HPS E-17 clear medium base 70HPS E-17 clear medium base METAL HALIDE 50MH E-17 clear medium base 70MH E-17 clear medium base COMPACT FLUORESCENT 13PL Twin Tube GX23-2 2-pin base 42PL Triple Tube GX24q-3 4-pin base INCANDESCENT 60INC T-10 Medium base HALOGEN 150HAL T-4 Mini-can base Lamp Initial Watts Lumens1 50 70 50 70 13 42 60 150 4,000 6,300 3,060 5,150 900 3,200 745 2,800
6H x 6V 1,359 (1.0H x -13.0V) 125.4H x 106.1V 6H x 6V 2,064 (0.0H x -13.4V) 129.4H x 106.4V 7H x 6V 1,101 (0.0H x 11.8V) 130.5H x 106.8V 7H x 6V 1,640 (0.0H x -13.0V) 136.0H x 108.7V 7H x 6V 7H x 6V 7H x 6V 256 (0.0H x 14.3V) 576 (0.0H x -5.0V) 186 (0.0H x 10.3V) 138.3H x 119.8V 142.2H x 127.3V 136.3H x 120.3V
PowerPost by Engineered Products Co. (EP17): PVC fixture molded in black with K" NPT mount is corrosion free and UV resistant. Replaces EMT, conduit connectors and weatherproof boxes. 100% shatter resistant against denting and cracking. Angled bottom to eliminate cable congestion. NOTE: Should be used with a UL listed fixture and grounding means (i.e., third wire) suitable for use in wet locations.
1" 3K"
17K"
Lamp Initial Watts Lumens1 50 70 50 70 60 150 4,000 6,300 3,060 5,150 745 2,800
I.E.S. Type
Maximum Candlepower
Field Angle (10% of max.) 47.8H x 18.6V 47.7H x 18.5V 16.7H x 14.8V 16.6H x 14.6V 16.7H x 14.8V 24.5H x 10.7V
Beam Angle (50% of max.) 24.2H x 10.4V 23.7H x 10.3V 8.6H x 6.9V 8.3H x 6.7V 8.6H x 6.9V 7.7H x 5.6V
I.T.L. Iso Test No. Pg. Kim2157 110 50201 110 Kim2158 110 50200 110 Kim2159 110 50202 110
4H x 2V 13,968 (0.0H x 1.0V) 4H x 2V 22,359 (0.0H x 1.5V) 1H x 1V 38,271 (0.0H x -2.5V) 1H x 1V 66,642 (0.0H x -2.4V) 1H x 1V 9,318 (0.0H x -2.5V) 2H x 1V 35,656 (0.0H x 0.6V)
5"
3" DIA. K" NPSM Fixture Mount 4L" Cover (2) K" NPSM
Architectural Junction Box (JB1): Die-cast low copper anodized aluminum with K" NPSM fixture mount. Internal set screw provided for locking position. Two K" NPSM in bottom, 17 cu in. internal volume. CAUTION: Junction Box must be installed high enough to avoid contact with soil or standing water.
All Initial Lumen values shown are approximate and may vary from one manufacturer to another. Consult lamp manufacturers data for exact lumen and life data.
NOTE: For lamp/ballast information outside of the U.S.A. and Canada, please consult your local Kim representative. WARNING: All fixtures must be grounded in accordance with local codes or the National Electrical Code. Failure to do so may result in serious personal injury. Lamps by others.
Portable Spear Mount (J-25N): Cast iron with K" NPSM fixture mount. Hot dip galvanized finish. 5.5 cu in. splice compartment. 9' (SJTW-A) 3 wire cord and plug.
3K" DIA. K" NPSM Fixture Mount 2J" 6E"
32
KIM LIGHTING
KIM LIGHTING
33
AFL10
ARCHITECTURAL FLOODLIGHTS 70 - 175 WATT H.I.D. 500 WATT HALOGEN
AFL10 Series
Wall mounted with Horizontal Flood optics to illuminate ceiling surface and detail.
34
KIM LIGHTING
KIM LIGHTING
35
AFL10
Vandal Protection
An optional Lexan lens shield is available for applications where vandalism is anticipated. NOTE: Lexan is a polycarbonate plastic, therefore useful life is limited by UV deterioration from sunlight and metal halide lamps. Planned replacement at regular intervals is recommended when using this option.
AFL-LS Lexan Lens Shield
Optical Control
The AFL10 Series has a variety of optical accessories to control glare and increase the visual effectiveness of the lighting scheme. Shielding devices are carefully engineered to prevent shadows and preserve beam efficiency while reducing undesirable transient brightness. Barn Doors are a familiar accessory that allow for fieldadjustable glare shielding. The Fixed Hood is a moderate shielding device and the Full Shield is a complete shielding device. Both are ideally suited for applications close to walkways, driveways, or roadways. The Grid Louver is engineered to maximize beam efficiency while minimizing glare and shadows from the internal vanes.The GL4 louver is available for use with the AFL15 and AFL16. The Lexan Lens Shield is available for applications where vandalism is anticipated. The Color Filter Assembly is designed to be used alone or in conjunction with the Barn Doors, Fixed Hood, or Full Shield. Dynamic floodlighting effects are possible by utilizing any of the color filters specifically engineered for use in high temperature floodlighting applications. See page 47 for details.
BD Barn Doors
FH Fixed Hood
FS Full Shield
Color Filters
KIM LIGHTING 37
AFL10
Main Beam Main Beam Main Beam Main Beam 50% Main Beam Main Beam 50% 50% 50% 50% 50%
Main Beam
Main Beam
50%
50%
Main Beam 50% 50% Main Beam 50% Main Beam
50%
50%
Main Beam
NOTE: AFL16 beam is rendered at K scale to the other AFL10 Series spreads on these pages.
50%
AFL15 Spot
The AFL15 spot reflector is a concentrated beam designed to light objects which are 20' to 50' from the fixture. It may also be located close to a building where the effect of grazing light is desired to show surface texture, or to highlight reliefs and projections.
38
KIM LIGHTING
KIM LIGHTING
39
AFL10
40
KIM LIGHTING
KIM LIGHTING
41
AFL10
Medium Base 70 to 500 Watt
Fixture Options
Mounting Options
Cat. No.:
FS
BD/WH-P
6-11
SM18/WH-P
12-28
Formed A" thick aluminum. Mounts to predrilled door frame holes. CAUTION: Do not use in locations where leaves and trash can collect inside shield. Formed A" thick aluminum. Mounts to predrilled door frame holes. Provides glare control for AFL15 and AFL16 Spots while maintaining beam efficiency and uniformity.
1 Fixture:
Cat. No. designates AFL10 fixture and beam pattern. Single fixture EPA with standard swivel: 0.7 (45 tilt) 1.0 (Face on) Beam Pattern: Cat. No.: Wide Flood AFL11 Vertical Flood AFL12 Medium Flood AFL13 Narrow Flood AFL14
Cat. No.:
GL4
AFL-LS
F" clear convex UV stabilized vacuum formed polycarbonate with gasket. Mounts over lens to predrilled door frame holes and may be used with BD Barn Door, FH Fixed Hood, or FS Full Shield option. CAUTION: Use only when vandalism is anticipated. Useful life is limited by UV discoloration from sunlight and metal halide lamps.
Cat. No.:
CFA1-XX
Color Filter Assembly Cat. No. includes color filter and channel finish. Specify filter, substituting XX for color filter number (See below) and add finish. Color Filter: XX: Deep Straw 15
Heavy wall aluminum extrusion with anti-reflection baffles and vertical channels that hold the color filter 2" away from the fixture lens. Quick change-out of the color filter is possible by the removal of two channel screws. Support mounts to predrilled holes in fixture door frame. May be used in conjunction with BD Barn Doors, FH Fixed Hood or FS Full Shield option. Rose Tint 05 Medium Red 27 Brilliant Blue 69 Primary Green 91
Spot AFL15 70HPS120 70HPS208 70HPS240 70HPS277 70HPS347 70MH120 70MH208 70MH240 70MH277 70MH347
Narrow Spot AFL16 100HPS120 100HPS208 100HPS240 100HPS277 100HPS347 100MH120 100MH208 100MH240 100MH277 100MH347 Light Gray LG-P
2 Electrical Module:
HPS = High Pressure Sodium MH = Metal Halide HAL = Halogen See lamp and electrical data on pages 96-98 for ballast types and characteristics.
150HPS120 150HPS208 150HPS240 150HPS277 150HPS347 150MH120 150MH208 150MH240 150MH277 150MH347 Platinum Silver PS-P 175MH120 175MH208 175MH240 175MH277 175MH347 White WH-P 500HAL120
Example: CFA1-05/DB-P
12 Brass In-grade
Architectural Junction Box:
Standard Swivel Mount.
Cat. No.: JBR-2 JBR-3 JBR-21 JBR-24 Cat. No.: JBR30 (2) K" NPT in bottom, (2) 19" long stakes (2) K" NPT in bottom (2) L" NPT in bottom (2) K" NPT in sides, (2) K" NPT in bottom (4) K" NPT in sides, (2) K" NPT in bottom
Die-cast brass with K" NPSM fixture mount and die-cast cover. Internal set screw provided for locking position. 21 cu in. internal volume.
3 Finish:
Super TGIC powder coat paint over chromate conversion coating.
Black BL-P
Die-cast brass with K" NPSM fixture mount and die-cast cover. Internal set screw provided for locking position. 21 cu in. internal volume. CAUTION: To assure a rigid installation, Staked Junction Box must be set in concrete (by others).
Cat. No.:
HDS
Recommended for vandal resistant requirements. Heavy cast low copper aluminum with locking teeth, aiming range of 200 vertical in 5 increments and 360 horizontal rotation. The swivel mounts directly to a 2" pipe-size tenon, with heavy duty C" stainless steel set point screws provided to firmly lock the fixture in place. 208V 240V 277V 347V
Cat. No.:
SM18
3" O.D. by .188" wall cast low copper aluminum with K" NPSM fixture mount and hand hole with flush cover. Internal set screw fixture lock accessible through hand hole. Internal ground lug supplied with installed lead. CAUTION: To assure a rigid installation, stanchion must be set in concrete (by others).
5 Optional Photocell:
120V A-30
A-31 A-32 A-33 A-35 CAUTION: Use only in locations where adjacent lighting will not affect operation of photocell. Extruded aluminum doors with anti-reflection baffles. Each door is hinged to a cast low copper aluminum frame, and locks by set screws. Doors are individually removable. Barn Door assembly mounts to predrilled door frame holes. CAUTION: Not recommended for ground mounted fixtures in vandal prone areas.
15 Surface Mount:
Standard Swivel Mount.
Cat. No.:
J-27N
Cast low copper aluminum with mounting ears for wood screw attachment to tree or wood structure. 5.5 cu in. splice compartment with gasketed cover. K" NPSM fixture mount and K" NPSM conduit or cord seal entry. NOTE: Surface mount can be connected to conduit or outdoor cord with a waterproof cord seal (by others).
Cat. No.:
BD
Cat. No.:
WM
Cat. No.:
FH
Formed A" thick aluminum. Mounts to predrilled door frame holes. Can be mounted along the top or bottom of the fixture to shield the lamp and lens from view.
Electro zinc steel mounting plate adapts to standard 4" square or octagonal Junction Boxes. Fixture mounts to cast low copper aluminum upper cover which attaches to mounting plate. Lower cover half provides splice access. Dielectric sealing compound provided for wall interface.
KIM LIGHTING
43
AFL10
Medium Base 70 to 500 Watt
Die-cast low copper anodized aluminum cylindrical body and matching cover with K" NPSM fixture mount. One piece molded silicone cover gasket. Captive countersunk cover screws. Internal set screw provided for locking position. Two K" NPSM in bottom, 17 cu in. internal volume. CAUTION: Junction Box must be installed high enough to avoid contact with soil or standing water.
Cat. No.:
WM2
2" pipe-size tenon (2C" O.D., 2" I.D.) welded to an extruded aluminum arm with a removable end cap for wiring access. Arm is welded to a cast aluminum plate with two K" mounting holes.
18 Wall Mount:
Standard Swivel Mount. Component EPA: 0.3
Cat. No.:
WM1
Extruded aluminum arm with a removable end cap for wiring access. Arm is welded to a cast aluminum plate with two K" dia. mounting holes.
Cat. No.:
WEB
The wall embedment bracket provides C-16 bolt receptacles welded in a galvanized re-bar cage for casting into poured-in-place concrete walls. Bolt receptacles receive fixture attachment bolts. Extruded aluminum arm with one 2" pipe-size tenon. Removable end cap for wiring access. For use with other Kim Site/Roadway Luminaires as an additional mid-pole floodlight.
Cat. No.:
SPT-X
Side Pole Mount Cat. No. includes pole dia. and finish. For round poles, specify X pole dia. and add finish. Mounts to 3", 3K", 4", 5" or 6" O.D. round poles. Example: SPT-4/BL-P for 4" Round Pole For square poles, omit -X and add finish. Example: SPT/BL-P for Square Pole
Cat. No.:
SPM-X
Side Pole Mount Cat. No. includes pole dia. and finish. For round poles, specify X pole dia. and add finish. Mounts to 3", 3K", 4", 5" or 6" O.D. round poles. Example: SPM-4/BL-P for 4" Round Pole For square poles, omit -X and add finish. Example: SPM/BL-P for Square Pole
Cat. No.:
M2B
Extruded aluminum arm with two 2" pipe-size tenons. Can be mounted on a SM2, SMT or Steel Kim Pole with steel 2" pipe-size tenon (2C" O.D. x 3K" min. length). Removable end caps for wiring access. CAUTION: Approved for mounting to poles with steel tenons only.
20 Twin Mount:
Standard Swivel Mount. Component EPA: 0.6
Cat. No.:
TM2
Cat. No.:
M3E
Extruded aluminum arm with three 2" pipe-size tenons. Can be mounted on a SM2, SMT or Steel Kim Pole with steel 2" pipe-size tenon (2C" O.D. x 3K" min. length). Removable end caps for wiring access. CAUTION: Approved for mounting to poles with steel tenons only.
Cat. No.:
PT
Cast aluminum mount for pole or other mounting option with 2" pipe-size tenon (2C" O.D. x 3K" minimum length). Fixture attaches with concealed internal studs, mounting is with J-20 allen set screws. Top cap provides splice access. Cast aluminum mount for pole or other mounting option with 2" pipe-size tenon (2C" O.D. x 3K" minimum length). Fixture attaches with concealed internal studs, mounting is with J-20 allen set screws. Top cap provides splice access.
Cat. No.:
PT2
SMT/BL-P
2" pipe-size tenon welded to a cast aluminum plate. Plate has four K" mounting holes, and tenon has one K" NPT for side conduit entry. NOTE: May be wall mounted if horizontal fixture adjustment is not required. For wall mounting with horizontal fixture adjustment, use WM2.
SM2/BL-P
4" O.D. cast low copper aluminum stanchion with 2" pipesize tenon (2C" O.D., 1C" I.D.) for mounting a single fixture or multiple top-mounts. CAUTION: Multiple top-mounts must not be used in locations where people can climb on fixtures and mounting arms. To assure a rigid installation, Stanchion must be set in concrete (by others).
44
KIM LIGHTING
KIM LIGHTING
45
AFL10
Ordered separately from fixture. See pages 42-45 for complete ordering information.
Barn Doors (BD): Extruded aluminum doors with anti-reflection baffles. Each door is hinged to a cast low copper aluminum frame, and locks by set screws. Doors are individually removable. Barn Door assembly mounts to predrilled door frame holes. CAUTION: Not recommended for ground mounted fixtures in vandal prone areas. Fixed Hood (FH): Formed A" thick aluminum. Mounts to predrilled door frame holes. Can be mounted along the top or bottom of the fixture to shield the lamp and lens from view.
14"
4" 7L"
9" 1D"
Full Shield (FS): Formed A" thick aluminum. Mounts to predrilled door frame holes. CAUTION: Do not use full shield in locations where leaves and trash can collect inside shield.
14"
4" 7L"
SIDE
Grid Louver for AFL15 and AFL16 (GL4): Formed A" thick aluminum. Mounts to predrilled door frame holes. Provides glare control for AFL15 and AFL16 Spots while maintaining beam efficiency and uniformity. NOTE: For use with AFL15 and AFL16 only.
14"
4" 7L"
AIMING RANGE May be limited by selected mounting option as shown on pages 48-51
with OPTIONAL HEAVY DUTY SWIVEL EPA 0.8 (45 tilt) 1.1 (Face on) Maximum weight: 25 lb
6L" 14"
Lexan Lens Shield (AFL-LS): F" clear convex UV stabilized vacuum formed polycarbonate with gasket. Mounts over lens to predrilled door frame holes and may be used with BD Barn Door, FH Fixed Hood, or FS Full Shield option. CAUTION: Use only when vandalism is anticipated. Useful life is limited by UV discoloration from sunlight and metal halide lamps. NOTE: Not for use with GL4 Louver or CFA1 color filter options. Color Filter Assembly (CFA1-XX): Heavy wall aluminum extrusion with anti-reflection baffles and vertical channels that hold the color filter 2" away from the fixture lens. Quick change-out of the color filter is possible by the removal of two channel screws. Support mounts to predrilled holes in fixture door frame. May be used with BD Barn Door, FH Fixed Hood, or FS Full Shield option. Color Filter Assembly includes color filter. Sample Color1 XX Filter # 2 Description Deep Straw 15
13L" 7C"
3K"
12J" 7N"
9"
2G"
Warms metal halide color. Deepens high pressure sodium color to yellow/orange.
Rose Tint
05
Warms metal halide color. Deepens high pressure sodium color to pink/orange.
Medium Red
27
Deep color accent. Best used with high pressure sodium lamps. NOTE: Very low output with metal halide lamps. Deep color accent. Best used with metal halide lamps. NOTE: Not recommended for high pressure sodium lamps. Deep color accent. Blue shift with metal halide lamps. Yellow shift with high pressure sodium lamps.
Brilliant Blue
69
Primary Green 2E" AIMING RANGE May be limited by selected mounting option as shown on pages 51-52
46 KIM LIGHTING
91
2E"
NOTE: Color samples shown for reference only and will not represent actual illumination color rendered by H.I.D. lamps. 1 Exact color output is highly dependent on lamp used, (i.e. HPS vs. MH, specific lamp color temperature and other factors). 2 XX Color filter number corresponds with Roscolux color filter numbers.
KIM LIGHTING
47
AFL10
Ordered separately from fixture. See pages 42-45 for complete ordering information.
Brass In-grade Staked Architectural Junction Box (JBR30): Diecast brass with K" NPSM fixture mount and die-cast cover. Internal set screw provided for locking position. 21 cu in. internal volume. Standard Swivel Mount
3L" DIA. K" NPSM Fixture Mount K" 3"
Standard Swivel
The standard swivel mounted on either the JBR-2, JBR-3, JBR30, WM1, SPM, or TM2 provides aiming between -15 to 125 off vertical. The standard swivel mounted on either the SM18 or JB1 provides full aiming between -35 to 125 off vertical.
25 Year Limited Warranty: Solid brass Junction Boxes are warranted for 25 years, from date of sale, against manufacturing defects and failure due to corrosion. Application Notes Creates a flush-mounted appearance. May be cast in concrete for increased stability. CAUTION: Fixture stem and swivel must not contact soil or standing water. Provide drainage away from Junction Box.
15E"
Stanchion Mount (SM18): 3" O.D. by .188" wall cast low copper aluminum with K" NPSM fixture mount and hand hole with flush cover. Internal set screw fixture lock accessible through hand hole. Internal ground lug supplied with installed lead. Standard Swivel Mount
3" DIA. K" NPSM Fixture Mount
PT Mounting
The PT post top mount may be used on any 2" tenon mount, including the SMT, SM2, WM2, SPT, M2B, M3E, or post top tenon. The PT2 twin post top mount is for use on the SM2 or 2" post top tenon only.
Ordered separately from fixture. See pages 42-45 for complete ordering information.
Brass In-grade Architectural Junction Box (JBR-2, JBR-3, JBR-21, JBR-24): Die-cast brass with K" NPSM fixture mount and die-cast cover. Internal set screw provided for locking position. 21 cu in. internal volume. Standard Swivel Mount
Surface Mount (J-27N): Cast low copper aluminum with mounting ears for wood screw attachment to tree or wood structure. 5.5 cu in. splice compartment with gasketed cover. K" NPSM fixture mount and K" NPSM conduit or cord seal entry. Standard Swivel Mount NOTE: Surface mount can be connected to conduit or outdoor cord with a waterproof cord seal (by others).
2F" K" NPSM Fixture Mount K" NPSM Conduit Entry 1L" 4K"
3L" DIA. K" NPSM Fixture Mount Optional Concrete (by others) K" 3"
25 Year Limited Warranty: Solid brass Junction Boxes are warranted for 25 years, from date of sale, against manufacturing defects and failure due to corrosion. Application Notes Creates a flush-mounted appearance. May be cast in concrete for increased stability. CAUTION: Fixture stem and swivel must not contact soil or standing water. Provide drainage away from Junction Box.
Wall or Ceiling Mount (WM): Electro zinc steel mounting plate adapts to standard 4" square or octagonal Junction Boxes. Fixture 6" MIN. mounts to cast aluminum upper cover which attaches to mounting plate. Lower cover12" MAX. half provides splice access. Dielectric sealing compound provided for wall interface. Standard Swivel Mount
1"
Fixture Mount
6" DIA.
Cover
48 KIM LIGHTING
AFL10
Ordered separately from fixture. See pages 42-45 for complete ordering information.
Post Top Mount (PT): Cast aluminum mount for pole or other mounting option with 2" pipe-size tenon (2C" O.D. x 3K" minimum length). Fixture attaches with concealed internal studs, mounting is with J-20 allen set screws. Top cap provides splice access. Standard Swivel Mount
Standard Swivel Mount CAUTION: Junction Box must be installed high enough to avoid contact with soil or standing water.
Option with 2" Pipe-Size Tenon (WM2, SMT, SM2, M2B, M3E, or KIM Pole)
Component EPA: 0.7 Twin Post Top Mount (PT2): Cast aluminum mount for pole or other mounting option with 2" pipe-size tenon (2C" O.D. x 3K" minimum length). Fixture attaches with concealed internal studs, mounting is with J-20 allen set screws. Top cap provides splice access. Standard Swivel Mount NOTE: Not for use with SMT, SPT, WM2, M2B, or M3E options.
4"
Wall Mount (WM1): Extruded aluminum arm with a removable end cap for wiring access. Arm is welded to a cast aluminum plate with two K" dia. mounting holes. Standard Swivel Mount
4J" 10J" 5F"
Splice Access 4K" Fixture Mounts (2) at 180 Option with 2" Pipe-Size Tenon (SM2 or KIM Pole)
7"
15"
The included Wall Embedment Bracket (WEB) provides C-16 bolt receptacles welded in a galvanized re-bar cage for casting into pouredin-place concrete walls. Bolt receptacles receive fixture attachment bolts.
Component EPA: 0.1 Surface Mount Tenon (SMT): 2" pipe-size tenon (2C" O.D., 2" I.D.) welded to a cast aluminum plate. Plate has four K" mounting holes, and tenon has one K" NPT for side conduit entry. 2" Tenon - For Optional Heavy Duty Swivel Mount Only NOTE: Not for use with PT2, M2B, or M3E options. May be wall mounted if horizontal fixture adjustment is not required. For wall mounting with horizontal fixture adjustment, use WM2 (see page 45).
Component EPA: 0.3 Side Pole Mount (SPM): Extruded aluminum arm. Internal set screw fixture lock. Removable end cap for wiring access. For use with other Kim Site/Roadway Luminaires as an additional mid-pole floodlight. Standard Swivel Mount
2" Pipe-Size Tenon K" NPT Conduit Entry (4) K" DIA. Holes on 5" circle
5K"
Component EPA: 0.3 Twin Mount (TM2): Extruded aluminum arm. Internal set screw fixture locks. Can be mounted on a SM2, SMT or Steel Kim Pole with steel 2" pipe-size tenon (2C" O.D. x 3K" min. length). Removable end caps for wiring access. Standard Swivel Mount CAUTION: Approved for mounting to poles with steel tenons only.
Stanchion Mount Tenon (SM2): 4" O.D. cast low copper aluminum stanchion with 2" pipe-size tenon (2C" O.D., 1C" I.D.) for mounting a single fixture or multiple top-mounts. 2" Tenon - For Optional Heavy Duty Swivel Mount Only CAUTION: Multiple top-mounts must not be used in locations where people can climb on fixtures and mounting arms. To assure a rigid installation, stanchion must be set in concrete (by others).
4K" 2" Pipe-Size Tenon 3" DIA. 1" MIN. 7K" MAX.
6K"
Option with Steel 2" Pipe-Size Tenon (SM2, SMT, or Steel KIM Pole)
AFL10
Ordered separately from fixture. See pages 42-45 for complete ordering information.
Wall Mount (WM2): 2" pipe-size tenon (2C" O.D., 2" I.D.) welded to an extruded aluminum arm with a removable end cap for wiring access. Arm is welded to a cast aluminum plate with two K" mounting holes. 2" Tenon - For Optional Heavy Duty Swivel Mount Only
4J" 10J" 7" 5F" 15" Lamp HIGH PRESSURE SODIUM 70HPS ED-17 clear medium base 100HPS ED-17 clear medium base 150HPS ED-17 clear medium base METAL HALIDE 70MH ED-17 clear medium base 100MH 150MH ED-17 clear medium base ED-17 clear medium base Lamp Initial Watts Lumens1 70 100 150 70 100 150 175 500 6,300 9,500 16,000 5,000 7,200 11,500 14,000 10,450
I.T.L. Iso Test No. Pg. 32061 32062 32063 36448 32710 36244 32709 39577 119 119 119 119 119 119 119 119
4"
7H x 7V 1,512 (65.0H x -15.0V) 165.9H x 140.4V 7H x 7V 2,276 (45.0H x -5.0V) 164.5H x 139.3V 7H x 7V 3,672 (45.0H x -15.0V) 163.7H x 141.8V 7H x 7V 1,945 (60.1H x -15.3V) 153.5H x 131.4V 7H x 7V 1,762 (55.0H x -35.0V) 155.6H x 137.0V 7H x 7V 3,961 (56.0H x -13.6V) 164.8H x 137.9V 7H x 7V 3,426 (55.0H x -35.0V) 155.6H x 137.0V 7H x 7V 2,314 45.0H x -15.0V 160.1H x 150.5V
The included Wall Embedment Bracket (WEB) provides C-16 bolt receptacles welded in a galvanized re-bar cage for casting into poured-inplace concrete walls. Bolt receptacles receive fixture attachment bolts.
142.0H x 99.0V
140.0H x 102.0V
2
NOTE: Not for use with PT2 option. Component EPA: 0.3
140.0H x 100.0V
2 2
175MH ED-17 clear medium base HALOGEN 500HAL T-4 Mini-can base
1 2
140.7H x 116.8V
Side Pole Tenon (SPT): Extruded aluminum arm with one 2" pipe-size tenon (2C" O.D., 2" I.D.). Removable end cap for wiring access. For use with other Kim Site/Roadway Luminaires as an additional mid-pole floodlight. 2" Tenon - For Optional Heavy Duty Swivel Mount Only NOTE: Not for use with PT2 option.
All Initial Lumen values shown are approximate and may vary from one manufacturer to another. Consult lamp manufacturers data for exact lumen and life data. Beam Angle: Horizontal and vertical beam spreads interpolated due to no valid I.E.S. standard.
Field Angle (10% of max.) 124.3H x 106.9V 123.3H x 105.7V 124.3H x 106.5V
Beam Angle (50% of max.) 84.0H x 72.5V 84.0H x 72.0V 86.0H x 70.0V 90.0H x 85.0V 84.0H x 75.0V 86.0H x 78.0V 84.0H x 78.0V 88.7H x 76.3V
I.T.L. Iso Test No. Pg. 32065 32066 32067 33037 33036 33035 33034 39578 127 127 127 127 127 127 127 127
15"
HIGH PRESSURE SODIUM 70HPS ED-17 clear medium base 100HPS ED-17 clear medium base 150HPS ED-17 clear medium base METAL HALIDE 70MH ED-17 clear medium base 100MH 150MH ED-17 clear medium base ED-17 clear medium base
27K"
Twin Tenon Mount (M2B): Extruded aluminum arm with two 2" pipe-size tenons (2C" O.D., 2" I.D.). Can be mounted on a SM2, SMT or Steel Kim Pole with a steel 2" pipe-size tenon (2C" O.D. x 3K" min. length). Removable end caps for wiring access. 2" Tenon - For Optional Heavy Duty Swivel Mount Only NOTE: Not for use with PT2 option. CAUTION: Approved for mounting to poles with steel tenons only.
10"
3
4 4 4 4
133.7H x 112.4V 133.6H x 112.5V 133.6H x 112.4V 133.6H x 112.4V 133.7H x 109.8V
175MH ED-17 clear medium base HALOGEN 500HAL T-4 Mini-can base
All Initial Lumen values shown are approximate and may vary from one manufacturer to another. Consult lamp manufacturers data for exact lumen and life data. 4 Field Angle: Horizontal and vertical field spreads interpolated due to no valid I.E.S. standard. Option with Steel 2" Pipe-Size Tenon (SM2, SMT or Steel KIM Pole)
Beam Angle (50% of max.) 124.0H x 68.9V 124.0H x 68.9V 124.0H x 68.9V 124.0H x 54.6V 124.0H x 54.6V 124.0H x 54.6V 124.0H x 54.6V 120.0H x 60.2V
I.T.L. Iso Test No. Pg. Kim2151 135 Kim2150 135 Kim2136 135 Kim2149 135 Kim2148 135 Kim2147 135 Kim2129 135 Kim2138 135
47K" Option with Steel 2" Pipe-Size Tenon (SM2, SMT or Steel KIM Pole)
7H x 6V 1,681 (45.0H x -15.0V) 145.5H x 126.1V 7H x 6V 2,789 (45.0H x -15.0V) 145.5H x 126.1V 7H x 6V 6,112 (45.0H x -15.0V) 145.5H x 126.1V 7H x 6V 2,277 (45.0H x -5.0V) 145.8H x 127.0V 7H x 6V 3,659 (45.0H x -5.0V) 145.8H x 127.0V 7H x 6V 5,691 (45.0H x -5.0V) 145.8H x 127.0V 7H x 6V 6,098 (45.0H x -5.0V) 145.8H x 127.0V 7H x 6V 4,282 (45.0H x -15.0V) 146.0H x 128.0V
6 6 6 6
175MH ED-17 clear medium base HALOGEN 500HAL T-4 Mini-can base
5
All Initial Lumen values shown are approximate and may vary from one manufacturer to another. Consult lamp manufacturers data for exact lumen and life data. 6 Beam Angle: Horizontal and vertical beam spreads interpolated due to no valid I.E.S. standard.
NOTE: For lamp/ballast information outside of the U.S.A. and Canada, please consult your local Kim representative.
WARNING: All fixtures must be grounded in accordance with local codes or the National Electrical Code. Failure to do so may result in serious personal injury. Lamps by others.
KIM LIGHTING 53
7H x 6V 1,987 (25.0H x -5.0V) 141.0H x 117.0V 7H x 6V 3,296 (25.0H x -5.0V) 141.0H x 117.0V 7H x 6V 7,225 (25.0H x -5.0V) 141.0H x 117.0V 7H x 6V 7H x 6V 7H x 6V 7H x 6V 7H x 6V 3,455 (25.0H x 0.0V) 5,552 (25.0H x 0.0V) 8,637 (25.0H x 0.0V) 9,254 (25.0H x 0.0V) 5,503 (25.0H x 0.0V) 139.3H x 111.1V 139.3H x 111.1V 139.3H x 111.1V 139.3H x 111.1V 138.4H x 117.2V
8 8 8 8
175MH ED-17 clear medium base HALOGEN 500HAL T-4 Mini-can base
7 8
175MH ED-17 clear medium base HALOGEN 500HAL T-4 Mini-can base
11
All Initial Lumen values shown are approximate and may vary from one manufacturer to another. Consult lamp manufacturers data for exact lumen and life data. Beam Angle: Horizontal and vertical beam spreads interpolated due to no valid I.E.S. standard.
All Initial Lumen values shown are approximate and may vary from one manufacturer to another. Consult lamp manufacturers data for exact lumen and life data.
NOTE: For lamp/ballast information outside of the U.S.A. and Canada, please consult your local Kim representative. WARNING: All fixtures must be grounded in accordance with local codes or the National Electrical Code. Failure to do so may result in serious personal injury. Lamps by others.
3H x 2V 15,770 (0.0H x -3.3V) 4H x 3V 22,626 (0.0H x -2.0V) 4H x 3V 23,688 (0.0H x -1.5V) 3H x 1V 25,569 (0.0H x -2.8V) 4H x 2V 28,359 (0.0H x -2.1V) 3H x 2V 39,250 (0.0H x -1.0V) 3H x 2V 39,395 (0.0H x -3.0V) 3H x 2V 36,394 (0.0H x 0.4V)
175MH ED-17 clear medium base HALOGEN 500HAL T-4 Mini-can base
9
All Initial Lumen values shown are approximate and may vary from one manufacturer to another. Consult lamp manufacturers data for exact lumen and life data.
1H x 2V 89,780 (0.0H x -0.6V) 1H x 2V 98,819 (0.0H x -1.0V) 1H x 3V 124,570 (0.0H x 0.0V) 1H x 1V 114,100 (0.0H x 2.5V) 1H x 1V 121,995 (0.0H x -2.5V) 1H x 2V 193,928 (0.0H x 0.3V) 1H x 2V 136,870 (0.0H x 2.4V) 1H x 2V 91,062 (0.0H x 2.0V)
175MH ED-17 clear medium base HALOGEN 500HAL T-4 Mini-can base
10
All Initial Lumen values shown are approximate and may vary from one manufacturer to another. Consult lamp manufacturers data for exact lumen and life data.
NOTE: For lamp/ballast information outside of the U.S.A. and Canada, please consult your local Kim representative. WARNING: All fixtures must be grounded in accordance with local codes or the National Electrical Code. Failure to do so may result in serious personal injury. Lamps by others.
54 KIM LIGHTING KIM LIGHTING 55
AFL20 Series
with various optics used in combination to illuminate key building features.
AFL20
ARCHITECTURAL FLOODLIGHTS 250 - 400 WATT H.I.D.
56
KIM LIGHTING
KIM LIGHTING
57
AFL20
Multi-Function Swivel
The AFL20 swivel is constructed of heavy cast aluminum with locking teeth, and accomplishes three tasks: First it allows fixture aiming in the vertical plane by loosening a single recessed stainless steel bolt and setting locking teeth with 5 intervals. Second, it provides a field-splice compartment accessible through the opposite knob from the aiming adjustment. Third, the swivel slipfits a standard 2" tenon (see page 68), and is secured with four heavy duty stainless steel socket head set screws.
AFL22
AFL21
AFL23
AFL24 AFL25
Vandal Protection
AFL27
An optional Lexan lens shield is available for applications where vandalism is anticipated. NOTE: Lexan is a polycarbonate plastic, therefore useful life is limited by UV deterioration from sunlight and metal halide lamps. Planned replacement at regular intervals is recommended when using this option.
Optical Control
The AFL20 Series has a variety of optical accessories to control glare and increase the visual effectiveness of the lighting scheme. Shielding devices are carefully engineered to prevent shadows and preserve beam efficiency while reducing undesirable transient brightness. Barn Doors are a familiar accessory that allow for fieldadjustable glare shielding. The Fixed Hood is a moderate shielding device and the Full Shield is a complete shielding device. Both are ideally suited for applications close to walkways, driveways, or roadways. Grid Louvers are engineered to maximize beam efficiency while minimizing glare and shadows from the internal vanes. Two types of louvers are available, one for use with the AFL24, and the other for use with the AFL25 and AFL26. The Lexan Lens Shield is available for applications where vandalism is anticipated. The Color Filter Assembly is designed to be used alone or in conjunction with the Barn Doors, Fixed Hood, or Full Shield. Dynamic floodlighting effects are possible by utilizing any of the color filters specifically engineered for use in high temperature floodlighting applications. See page 69 for details.
Color Filters
KIM LIGHTING 59
AFL20
Main Beam Main Beam Main Beam Main Beam 50% Main Beam Main Beam 50% 50% 50% 50% 50%
Main Beam
Main Beam
50%
50%
Main Beam 50% 50% Main Beam 50% Main Beam
50%
50%
Main Beam
NOTE: AFL26 beam is rendered at K scale to the other AFL20 Series spreads on these pages.
50%
AFL25 Spot
The AFL25 produces a very concentrated beam capable of lighting architecture from distances up to 120', or creating very high light levels to highlight building features or flags from mid-range distances of 40' to 80'. The AFL25 may also be located close to structures using a high grazing angle to highlight building reliefs and projections, or to accentuate surface texture. It can also be used used in combination with other AFL20 Series models to extend their range or reshape the overall light pattern.
60
KIM LIGHTING
KIM LIGHTING
61
AFL20
BD2
Barn Doors for all models page 69
FH2
Fixed Hood for all models page 69
FS2
Full Shield for AFL23, 24, 25, and 26 page 69
AFL-LS2
Lexan Lens Shield for all models page 69
CFA2
Color Filter Assembly for all models page 69
GL8
Grid Louver for AFL24 only page 69
GL9
Grid Louver for AFL25 and 26 only page 69
AFL25 Spot
SMT
Surface Mount Tenon page 70
SPR2
Side Pole Mount for Round Pole page 71
WM2
Wall Mount page 71
SPS2
Side Pole Mount for Square Pole page 71
MTM-2B
Twin Mount page 72
MTM-3E
Triple Mount page 72
SM2
Stanchion Mount Tenon page 70 Pole with 2" pipe size tenon by Kim or others. Steel tenon required for two or more fixtures.
By others
62
KIM LIGHTING
KIM LIGHTING
63
AFL20
Mogul Base 250 to 400 Watt
Fixture Options
Mounting Options
Cat. No.:
BD2
BD2/WH-P
5-11
SMT/WH-P
12-18
Extruded aluminum doors with anti-reflection baffles. Each door is hinged to a cast aluminum frame, and locks by set screws. Doors are individually removable. Barn Door assembly mounts to predrilled door frame holes. CAUTION: Not recommended for ground mounted fixtures in vandal prone areas.
1 Fixture:
Cat. No. designates AFL20 fixture and beam pattern. Single fixture EPA: 1.3 (45 tilt) 2.3 (Face on)
Cat. No.:
FH2
Formed A" thick aluminum. Mounts to predrilled door frame holes. May be used with AFL-LS2 option. Can be mounted along the top or bottom of the fixture to shield the lamp and lens from view. Provides moderate shielding for ground mounted fixtures next to walkways, drive-ways or roadways. Best suited for AFL21 and AFL22.
Cat. No.:
FS2
Formed A" thick x 8" deep aluminum. Mounts to predrilled lens frame holes and provides complete shielding around the perimeter of lens opening. Best suited for AFL23, AFL24, AFL25, and AFL26. CAUTION: Do not use full shield in locations where leaves and trash can collect inside shield.
Cat. No.:
GL8
Formed A" thick aluminum. Mounts to predrilled door frame holes. Provides glare control for AFL24 while maintaining beam efficiency and uniformity.
Spot AFL25 250HPS120 250HPS208 250HPS240 250HPS277 250HPS347 250HPS480 250MH120 250MH208 250MH240 250MH277 250MH347 250MH480
Narrow Spot AFL26 400HPS120 400HPS208 400HPS240 400HPS277 400HPS347 400HPS480 400MH120 400MH208 400MH240 400MH277 400MH347 400MH480 Light Gray LG-P
2 Electrical Module:
HPS = High Pressure Sodium MH = Metal Halide PMH = Pulse Start Metal Halide See lamp and electrical data on pages 96-98 for ballast types and characteristics.
Cat. No.:
GL9
Formed A" thick aluminum. Mounts to predrilled door frame holes. Provides glare control for AFL25 and AFL26 while maintaining beam efficiency and uniformity.
400PMH120 400PMH208 400PMH240 400PMH277 400PMH347 400PMH480 White WH-P Custom Colors CC-P Consult representative for custom colors. 480V A-34 347V A-35
AFL-LS2
F" clear convex UV stabilized vacuum formed polycarbonate with gasket. Mounts over lens to predrilled door frame holes and may be used with BD2 Barn Door, FH2 Fixed Hood, or FS2 Full Shield option. CAUTION: Use only when vandalism is anticipated. Useful life is limited by UV discoloration from sunlight and metal halide lamps.
3 Finish:
Super TGIC powder coat paint over chromate conversion coating.
Black BL-P
4 Optional Photocell:
120V A-30
208V A-31
240V A-32
277V A-33
Cat. No.:
CFA2-XX
Color Filter Assembly Cat. No. includes color filter and channel finish. Specify filter, substituting XX for color filter number (See below) and add finish. Color Filter: XX: Deep Straw 15
Heavy wall aluminum extrusion with anti-reflection baffles and vertical channels that hold the color filter 2" away from the fixture lens. Quick change-out of the color filter is possible by the removal of two channel screws. Support mounts to predrilled holes in fixture door frame. May be used in conjunction with FH2 or BD2 options. Rose Tint 05 Medium Red 27 Brilliant Blue 69 Primary Green 91
Example: CFA2-05/DB-P
64 KIM LIGHTING KIM LIGHTING 65
AFL20
Mogul Base 250 to 400 Watt
4" O.D. cast low copper aluminum stanchion with 2" pipesize tenon for mounting a single fixture or multiple topmounts. CAUTION: Multiple top-mounts must not be used in locations where people can climb on fixtures and mounting arms. To assure a rigid installation, Stanchion must be set in concrete (by others).
Cat. No.:
MTM-2B
Extruded aluminum support continuously welded to a heavy cast aluminum slipfitter hub which cradles the arm for strength. The slipfitter hub contains four recessed C" stainless steel allen head set point screws for mounting to steel pole with steel 2" pipe size tenon (2C" O.D. x 4J"). Cast aluminum end caps and center cap provide access to field splice connections. CAUTION: Approved for mounting to poles with steel tenons only.
Cat. No.:
MTM-3E
SMT/BL-P
2" pipe-size tenon welded to a cast aluminum plate. Plate has four K" mounting holes, and tenon has one K" NPT for side conduit entry. NOTE: May be wall mounted if horizontal fixture adjustment is not required. For wall mounting with horizontal fixture adjustment, use WM2.
Extruded aluminum support continuously welded to a heavy cast aluminum slipfitter hub which cradles the arm for strength. The slipfitter hub contains four recessed C" stainless steel allen head set point screws for mounting to steel pole with steel 2" pipe size tenon (2C" O.D. x 4J"). Cast aluminum end caps and center cap provide access to field splice connections. CAUTION: Approved for mounting to poles with steel tenons only.
Cat. No.:
WM2
2" pipe-size tenon welded to an extruded aluminum arm with a removable end cap for wiring access. Arm is welded to a cast aluminum plate with two K" mounting holes. The wall embedment bracket provides C-16 bolt receptacles welded in a galvanized re-bar cage for casting into poured-in-place concrete walls. Bolt receptacles receive fixture attachment bolts.
Cat. No.:
SPS2
2" pipe-size tenon welded to an extruded aluminum arm with a removable end cap for wiring access. Arm is welded to a cast aluminum plate with two K" mounting holes. Zinc plated steel backing plate is provided for insertion inside the pole for structural support.
Cat. No.:
SPR2-X
Side Pole Mount Cat. No. includes pole dia. and finish. For round poles, specify X pole dia. and add finish. Mounts to 3", 3K", 4", 5" or 6" O.D. round poles. Example: SPR2-4/BL-P for 4" Round Pole
2" pipe-size tenon welded to an extruded aluminum arm with a removable end cap for wiring access. Arm is welded to a cast aluminum plate with two K" mounting holes. Zinc plated steel backing plate is provided for insertion inside the pole for structural support.
66
KIM LIGHTING
KIM LIGHTING
67
AFL20
Ordered separately from fixture. See pages 64-67 for complete ordering information.
Barn Doors (BD2): Extruded aluminum doors with anti-reflection baffles. Each door is hinged to a cast aluminum frame, and locks by set screws. Doors are individually removable. Barn Door assembly mounts to predrilled door frame holes. May be used with AFL-LS2 or CFA2 option. CAUTION: Not recommended for ground mounted fixtures in vandal prone areas. Fixed Hood (FH2): Formed A" thick aluminum. Mounts to predrilled door frame holes. May be used with AFL-LS2 or CFA2 option. Can be mounted along the top or bottom of the fixture to shield the lamp and lens from view. Provides moderate shielding for ground mounted fixtures next to walkways, drive-ways or roadways. Full Shield (FS2): Formed A" thick x 8" deep aluminum. Mounts to predrilled lens frame holes and provides complete shielding around the perimeter of lens opening. May be used with AFL-LS2 or CFA2 option. CAUTION: Do not use full shield in locations where leaves and trash can collect inside shield. Grid Louver for AFL24 (GL8): Formed A" thick aluminum. Mounts to predrilled door frame holes. Provides glare control for AFL24 while maintaining beam efficiency and uniformity. NOTE: For use with AFL24 only. Grid Louver for AFL25 and AFL26 (GL9): Formed A" thick aluminum. Mounts to predrilled door frame holes. Provides glare control for AFL25 and AFL26 while maintaining beam efficiency and uniformity. NOTE: For use with AFL25 and AFL26 only. Polycarbonate Lens Shield (AFL-LS2): F" clear convex UV stabilized vacuum formed polycarbonate with gasket. Mounts over lens to predrilled door frame holes and may be used with BD2 Barn Door, FH2 Fixed Hood, or FS2 Full Shield option. CAUTION: Use only when vandalism is anticipated. Useful life is limited by UV discoloration from sunlight and metal halide lamps. NOTE: Not for use with GL8, GL9 Louver, or CFA2 color filter options. Color Filter Assembly (CFA2-XX): Heavy wall aluminum extrusion with anti-reflection baffles and vertical channels that hold the color filter 2" away from the fixture lens. Quick change-out of the color filter is possible by the removal of two channel screws. Support mounts to predrilled holes in fixture door frame. May be used with BD2 Barn Door, FH2 Fixed Hood, or FS2 Full Shield option. Color Filter Assembly includes color filter. Sample Color1 XX Filter # 2 Description Deep Straw 15
18L"
6" 13L"
18L"
8" 13L"
1 2
KIM LIGHTING
18L"
4" 13L"
6B"
7K"
18L"
4" 13L"
Slips over 2" pipe-size tenon (2C" O.D. x 4K" min. length) SIDE FRONT
1 AFL21
120
lamp position (base up) lamp position 24, 25, 26 lamp position (base down) lamp position
2 AFL22
0 Horizontal 75 AIMING RANGE with swivel clamp down Aiming line is always perpendicular to front face of fixture
3 AFL23,
4 AFL27
Warms metal halide color. Deepens high pressure sodium color to yellow/orange.
Rose Tint
05
Warms metal halide color. Deepens high pressure sodium color to pink/orange.
Medium Red
27
Deep color accent. Best used with high pressure sodium lamps. NOTE: Very low output with metal halide lamps. Deep color accent. Best used with metal halide lamps. NOTE: Not recommended for high pressure sodium lamps. Deep color accent. Blue shift with metal halide lamps. Yellow shift with high pressure sodium lamps.
Brilliant Blue
69
Primary Green
91
NOTE: Color samples shown for reference only and will not represent actual illumination color rendered by H.I.D. lamps. 1 Exact color output is highly dependent on lamp used, (i.e. HPS vs. MH, specific lamp color temperature and other factors). 2 XX Color filter number corresponds with Roscolux color filter numbers.
68 KIM LIGHTING KIM LIGHTING 69
AFL20
Ordered separately from fixture. See pages 64-67 for complete ordering information.
Wall Mount (WM2): 2" pipe-size tenon (2C" O.D., 2" I.D.) welded to an extruded aluminum arm with a removable end cap for wiring access. Arm is welded to a cast aluminum plate with two K" mounting holes.
4J"
Swivel
The standard heavy duty swivel mounted on either the SM2, SMT, WM2, SPS2, SPR2-X, MTM-2B, MTM-3E, or pole top tenon, provides aiming between -120 to 75 off horizontal.
5F"
10J"
The included Wall Embedment Bracket (WEB) provides C-16 bolt receptacles welded in a galvanized re-bar cage for casting into pouredin-place concrete walls. Bolt receptacles receive fixture attachment bolts.
4"
7"
15"
Component EPA: 0.3 Side Pole Mount Tenon for Square Poles (SPS2): 2" pipe-size tenon (2C" O.D., 2" I.D.) welded to an extruded aluminum arm with a removable end cap for wiring access. Arm is welded to a cast aluminum plate with two K" mounting holes. Zinc plated steel backing plate is provided for insertion inside the pole for structural support.
Ordered separately from fixture. See pages 64-67 for complete ordering information.
Stanchion Mount Tenon (SM2): 4" O.D. cast low copper aluminum stanchion with 2" pipe-size tenon (2C" O.D., 1C" I.D.) for mounting a single fixture or multiple top-mounts. CAUTION: Multiple top-mounts must not be used in locations where people can climb on fixtures and mounting arms. To assure a rigid installation, Stanchion must be set in concrete (by others).
4"
7"
2" Pipe-Size Tenon 3" DIA. 4K" 1" MIN. 7K" MAX.
15"
Component EPA: 0.3 Side Pole Mount Tenon for Round Poles (SPR2): 2" pipe-size tenon (2C" O.D., 2" I.D.) welded to an extruded aluminum arm with a removable end cap for wiring access. Arm is welded to a cast aluminum plate with two K" mounting holes. Zinc plated steel backing plate is provided for insertion inside the pole for structural support.
4"
7"
Surface Mount Tenon (SMT): 2" pipe-size tenon (2C" O.D., 2" I.D.) welded to a cast aluminum plate. Plate has four K" mounting holes, and tenon has one K" NPT for side conduit entry. NOTE: Not for use with M2B or M3E options. May be wall mounted if horizontal fixture adjustment is not required. For wall mounting with horizontal fixture adjustment, use WM2 (see page 67).
2" Pipe-Size Tenon K" NPT Conduit Entry (4) K" DIA. Holes on 5" circle
15"
5K"
5" sq.
70
KIM LIGHTING
KIM LIGHTING
71
AFL20
Ordered separately from fixture. See pages 64-67 for complete ordering information.
Twin Mount Tenon (MTM-2B): Extruded aluminum support continuously welded to a heavy cast aluminum slipfitter hub which cradles the arm for strength. The slipfitter hub contains four recessed C" stainless steel allen head set point screws for mounting to steel pole with steel 2" pipe size tenon (2C" O.D. x 4J"). Cast aluminum end caps and center cap provide access to field splice connections. CAUTION: Approved for mounting to poles with steel tenons only.
Lamp HIGH PRESSURE SODIUM 250HPS E-18 clear mogul base 400HPS E-18 clear mogul base METAL HALIDE 250MH BT-28 clear mogul base 400MH BT-28 clear mogul base PULSE START METAL HALIDE 250PMH ED-28 clear mogul base 400PMH ED-28 clear mogul base
1
2
I.T.L. Iso Test No. Pg. 34659 34660 34661 34662 34661 34662 175 175 175 175 175 175
7H x 6V 11,580 (55.0H x 15.0V) 146.8H x 124.0V 7H x 6V 17,596 (56.3H x 12.8V) 147.8H x 128.0V 7H x 6V 8,074 (55.0H x 15.0V) 146.6H x 126.0V 7H x 6V 14,021 (55.0H x 15.0V) 147.1H x 126.0V 7H x 6V 8,074 (55.0H x 15.0V) 146.6H x 126.0V 7H x 6V 14,021 (55.0H x 15.0V) 147.1H x 126.0V
136.0H x 100.0V
2
8"
126.0H x 87.0V
136.0H x 101.0V
2
126.0H x 87.0V
136.0H x 101.0V
All Initial Lumen values shown are approximate and may vary from one manufacturer to another. Consult lamp manufacturers data for exact lumen and life data. Beam Angle: Horizontal and vertical beam spreads interpolated due to no valid I.E.S. standard.
Lamp Initial Watts Lumens3 250 400 250 400 250 400 30,000 50,000 19,500 36,000 19,500 36,000
I.E.S. Type
Maximum Candlepower
Beam Angle (50% of max.) 80.0H x 16.0V 80.0H x 28.0V 76.0H x 33.0V 86.0H x 42.0V 76.0H x 33.0V 86.0H x 42.0V
I.T.L. Iso Test No. Pg. 34535 34541 34543 34697 34543 34697 181 181 181 181 181 181
57K"
6H x 4V 20,000 (14.7H x 15.8V) 118.0H x 71.0V 6H x 5V 32,192 (11.6H x 16.1V) 116.0H x 71.0V 6H x 5V 12,567 (18.0H x 14.5V) 128.0H x 80.8V 6H x 5V 19,896 (21.8H x 14.7V) 128.0H x 80.0V 6H x 5V 12,567 (18.0H x 14.5V) 128.0H x 80.8V 6H x 5V 19,896 (21.8H x 14.7V) 128.0H x 80.0V
4 4
4 4
All Initial Lumen values shown are approximate and may vary from one manufacturer to another. Consult lamp manufacturers data for exact lumen and life data. Beam Angle: Horizontal and vertical beam spreads interpolated due to no valid I.E.S. standard.
7H x 5V 22,808 (41.6H x -9.0V) 135.4H x 99.9V 7H x 6V 35,215 (38.9H x -8.9V) 137.1H x 107.0V 7H x 5V 18,251 (39.2H x 0.3V) 132.3H x 87.8V
400HPS E-18 clear mogul base METAL HALIDE 250MH BT-28 clear mogul base 400MH BT-28 clear mogul base PULSE START METAL HALIDE 250PMH ED-28 clear mogul base 400PMH ED-28 clear mogul base
5
7H x 5V 30,468 (39.3H x -1.6V) 134.1H x 98.6V 7H x 5V 18,251 (39.2H x 0.3V) 132.3H x 87.8V
All Initial Lumen values shown are approximate and may vary from one manufacturer to another. Consult lamp manufacturers data for exact lumen and life data.
NOTE: For lamp/ballast information outside of the U.S.A. and Canada, please consult your local Kim representative. WARNING: All fixtures must be grounded in accordance with local codes or the National Electrical Code. Failure to do so may result in serious personal injury. Lamps by others.
72 KIM LIGHTING KIM LIGHTING 73
Lamp Initial Watts Lumens6 250 400 250 400 250 400 30,000 50,000 20,500 36,000 20,500 36,000
I.E.S. Type
Maximum Candlepower
Lamp HIGH PRESSURE SODIUM 250HPS E-18 clear mogul base 400HPS E-18 clear mogul base METAL HALIDE 250MH BT-28 clear mogul base 400MH BT-28 clear mogul base PULSE START METAL HALIDE 250PMH ED-28 clear mogul base 400PMH ED-28 clear mogul base
Lamp Initial Watts Lumens9 250 400 250 400 250 400 30,000 51,000 21,000 36,000 21,000 36,000
I.E.S. Type 6H x 4V 6H x 4V 6H x 5V 6H x 5V 6H x 5V 6H x 5V
Maximum Candlepower 31,714 (0.0H x 1.2V) 53,318 (0.0H x 1.0V) 20,602 (5.0H x 0.5V) 35,158 (0.0H x 0.0V) 20,602 (5.0H x 0.5V) 35,158 (0.0H x 0.0V)
Field Angle (10% of max.) 109.1H x 64.9V 108.9H x 64.5V 112.8H x 75.1V 122.7H x 74.0V 112.8H x 75.1V 122.7H x 74.0V
Beam Angle (50% of max.) 90.1H x 13.1V 88.2H x 13.4V 95.8H x 15.8V 97.4H x 14.9V 95.8H x 15.8V 97.4H x 14.9V
I.T.L. Iso Test No. Pg. 48415 48416 48414 47773 48414 47773 211 211 211 211 211 211
6H x 5V 30,557 (10.4H x -9.4V) 122.3H x 82.0V 7H x 5V 42,560 (11.3H x -11.6V) 132.0H x 101.0V 5H x 4V 23,171 (12.0H x -2.5V) 74.4H x 69.0V
5H x 4V 38,650 (14.9H x -0.1V) 104.0H x 76.0V 5H x 4V 23,171 (12.0H x -2.5V) 74.4H x 69.0V
All Initial Lumen values shown are approximate and may vary from one manufacturer to another. Consult lamp manufacturers data for exact lumen and life data.
All Initial Lumen values shown are approximate and may vary from one manufacturer to another. Consult lamp manufacturers data for exact lumen and life data.
NOTE: For lamp/ballast information outside of the U.S.A. and Canada, please consult your local Kim representative. WARNING: All fixtures must be grounded in accordance with local codes or the National Electrical Code. Failure to do so may result in serious personal injury. Lamps by others. Maximum Candlepower Field Angle (10% of max.) 44.0H x 53.0V 48.2H x 63.0V 41.0H x 45.0V 44.3H x 48.0V 41.0H x 45.0V 44.3H x 48.0V Beam Angle (50% of max.) 20.0H x 27.0V 22.0H x 31.0V 21.0H x 24.0V 22.0H x 25.0V 21.0H x 24.0V 22.0H x 25.0V I.T.L. Iso Test No. Pg. 34537 34540 34545 34549 34545 34549 199 199 199 199 199 199
Lamp Initial Watts Lumens7 250 400 250 400 250 400 30,000 50,000 20,500 36,000 20,500 36,000
I.E.S. Type
3H x 4V 61,460 (0.0H x -7.3V) 4H x 4V 84,570 (0.0H x -8.8V) 3H x 3V 46,920 (0.0H x -1.4V) 3H x 3V 76,220 (0.0H x -1.8V) 3H x 3V 46,920 (0.0H x -1.4V) 3H x 3V 76,220 (0.0H x -1.8V)
All Initial Lumen values shown are approximate and may vary from one manufacturer to another. Consult lamp manufacturers data for exact lumen and life data.
Lamp Initial Watts Lumens8 250 400 250 400 250 400 30,000 51,000 21,000 36,000 21,000 36,000
I.E.S. Type
Maximum Candlepower
Field Angle (10% of max.) 24.5H x 48.2V 24.0H x 52.6V 18.6H x 20.0V 17.9H x 25.0V 18.6H x 20.0V 17.9H x 25.0V
Beam Angle (50% of max.) 13.9H x 20.0V 14.0H x 18.3V 9.0H x 8.3V 7.1H x 10.7V 9.0H x 8.3V 7.1H x 10.7V
I.T.L. Iso Test No. Pg. 46689 46690 46687 46901 46687 46901 205 205 205 205 205 205
2H x 4V 113,120 (4.2H x -1.2V) 2H x 4V 203,760 (3.3H x -1.4V) 2H x 2V 236,087 (0.0H x -0.9V) 1H x 2V 365,237 (0.0H x 0.0V) 2H x 2V 236,087 (0.0H x -0.9V) 1H x 2V 365,237 (0.0H x 0.0V)
All Initial Lumen values shown are approximate and may vary from one manufacturer to another. Consult lamp manufacturers data for exact lumen and life data.
NOTE: For lamp/ballast information outside of the U.S.A. and Canada, please consult your local Kim representative. WARNING: All fixtures must be grounded in accordance with local codes or the National Electrical Code. Failure to do so may result in serious personal injury. Lamps by others.
74 KIM LIGHTING KIM LIGHTING 75
AFL30
ARCHITECTURAL FLOODLIGHTS 750 - 1000 WATT H.I.D.
76
KIM LIGHTING
KIM LIGHTING
77
AFL30
Multi-Function Trunnion
The AFL30 Series includes a J" thick, 3K" wide steel trunnion to provide secure aiming at any angle. Four C" stainless steel set screws and two K" stainless steel mounting bolts lock fixture aiming into place.
AFL31 AFL32
AFL33
Ballast Enclosure
AFL34 AFL35
The AFL30 ballast housing is an independent casting, provided with a unique Gortex sealed ventilation system. Air is allowed to circulate and cool internal components while moisture is rejected. Access is provided through a gasketed cover, without disturbing the main housing/optical system enclosure.
AFL36
AFL37
Optical Control
The AFL30 Series has a variety of optical accessories to control glare and increase the visual effectiveness of the lighting scheme. Shielding devices are carefully engineered to prevent shadows and preserve beam efficiency while reducing undesirable transient brightness. Barn Doors are a familiar accessory that allow for fieldadjustable glare shielding. The Fixed Hood is a moderate shielding device and the Full Shield is a complete shielding device. Both are ideally suited for applications close to walkways, driveways, or roadways. Grid Louvers are engineered to maximize beam efficiency while minimizing glare and shadows from the internal vanes. Two types of louvers are available, one for use with the AFL34, and the other for use with the AFL35 and AFL36. See page 89 for details.
78
KIM LIGHTING
KIM LIGHTING
79
AFL30
Main Beam Main Beam Main Beam Main Beam 50% Main Beam Main Beam 50% 50% 50% 50% 50%
Main Beam
Main Beam
50%
50%
Main Beam 50% 50% Main Beam 50% Main Beam
50%
50%
Main Beam
NOTE: AFL36 beam is rendered at K scale to the other AFL30 Series spreads on these pages.
50%
AFL35 Spot
The AFL35 spot beam pattern is designed to illuminate taller surfaces when grade mounted or deeper areas when wall mounted. In general, AFL35 fixture spacing is less than AFL34, but the beam reaches higher or farther out. Recommended distance from the lighted surface is 40' to 120' depending on lamp and wattage
80
KIM LIGHTING
KIM LIGHTING
81
AFL30
BD2
Barn Doors for all models page 89
FH2
Fixed Hood for all models page 89
FS2
Full Shield for AFL33, 34, 35, and 36 page 89
GL8
Grid Louver for AFL34 only page 89
GL9
Grid Louver for AFL35 and 36 only page 89
AFL35 Spot
STM3
Single Mount Tenon page 90
SPR3
Side Pole Mount for Round Pole page 91
WM3
Wall Mount page 90
SPS3
Side Pole Mount for Square Pole page 91
MM-2B
Twin Mount page 91
MM-3E
Triple Mount page 92
SM2
Stanchion Mount Tenon page 92 Pole with 2" pipe size tenon by Kim or others. Steel tenon required for two or more fixtures.
By others
82
KIM LIGHTING
KIM LIGHTING
83
AFL30
Mogul Base 750 to 1000 Watt
Fixture Options
Mounting Options
Cat. No.:
BD2
BD2/WH-P
5-9
SM2/WH-P
10-17
Extruded aluminum doors with anti-reflection baffles. Each door is hinged to a cast aluminum frame, and locks by set screws. Doors are individually removable. Barn Door assembly mounts to predrilled door frame holes. CAUTION: Not recommended for ground mounted fixtures in vandal prone areas.
1 Fixture:
Cat. No. designates AFL30 fixture and beam pattern. Single fixture EPA: 1.3 (45 tilt) 2.3 (Face on)
Cat. No.:
FH2
Formed A" thick aluminum. Mounts to predrilled door frame holes. Can be mounted along the top or bottom of the fixture to shield the lamp and lens from view. Provides moderate shielding for ground mounted fixtures next to walkways, drive-ways or roadways. Best suited for AFL31 and AFL32.
Cat. No.:
FS2
Formed A" thick x 8" deep aluminum. Mounts to predrilled lens frame holes and provides complete shielding around the perimeter of lens opening. Best suited for AFL33, AFL34, AFL35, and AFL36. CAUTION: Do not use full shield in locations where leaves and trash can collect inside shield.
Spot AFL35
2 Electrical Module:
HPS = High Pressure Sodium MH = Metal Halide PMH = Pulse Start Metal Halide See lamp and electrical data on pages 96-98 for ballast types and characteristics.
Cat. No.:
GL8
Formed A" thick aluminum. Mounts to predrilled door frame holes. Provides glare control for AFL34 while maintaining beam efficiency and uniformity.
3 Finish:
Super TGIC powder coat paint over chromate conversion coating.
Black BL-P
White WH-P
Custom Colors CC-P Consult representative for custom colors. 480V A-34 347V A-35
4 Optional Photocell:
120V A-30
208V A-31
240V A-32
277V A-33
Cat. No.:
GL9
Formed A" thick aluminum. Mounts to predrilled door frame holes. Provides glare control for AFL35 and AFL36 while maintaining beam efficiency and uniformity.
84
KIM LIGHTING
KIM LIGHTING
85
AFL30
Mogul Base 750 to 1000 Watt
Die-cast brass with K" NPSM fixture mount and die-cast cover. Internal set screw provided for locking position. 21 cu in. internal volume.
15 Twin Mount:
Component EPA: 0.5
Cat. No.:
MM-2B
Cat. No.:
STM3
Heavy cast aluminum slipfitter contains four recessed C" stainless steel allen head set point screws for mounting fixture to a 2" pipe-size tenon (2C" O.D. x 4J" min. length). The slipfitter assembles to the fixture trunnion by two concealed stainless steel hex head bolts. The integral cast aluminum splice compartment and gasketed cast aluminum cover house the field-splice and ground connections. The fixture cord (supplied) enters through the splice-compartment side-wall and secures by a strain relief bushing.
Extruded aluminum support continuously welded to a heavy cast aluminum slipfitter hub which cradles the arm for strength. The slipfitter hub contains four recessed C" stainless steel allen head set point screws for mounting to pole with 2" pipe size steel tenon (2C" O.D. x 4J"). Fixture trunnion attaches to a cast aluminum swivel disc with a L" stainless steel hex head bolt (provided). The swivel disc provides 360 fixture rotation and comes equipped with two recessed C" stainless steel set point screws for locking fixture at the desired position. Fixture cords enter into arm through strain relief bushings. A cast aluminum end cap on each end provides access to field splice connections. CAUTION: Approved for mounting to poles with steel tenons only. Extruded aluminum support continuously welded to a heavy cast aluminum slipfitter hub which cradles the arm for strength. The slipfitter hub contains four recessed C" stainless steel allen head set point screws for mounting to pole with 2" pipe size steel tenon (2C" O.D. x 4J"). Cast aluminum end caps and center cap provide access to field splice connections. CAUTION: Approved for mounting to poles with steel tenons only.
16 Triple Mount:
Component EPA: 0.7
Cat. No.:
MM-3E
SM2/BL-P
4" O.D. cast aluminum stanchion with 2" pipe-size tenon (2C" O.D., 1C" I.D.) for mounting a single fixture or multiple top-mounts. CAUTION: Multiple top-mounts must not be used in locations where people can climb on fixtures and mounting arms. To assure a rigid installation, Stanchion must be set in concrete (by others).
Cat. No.:
SPS3
Extruded aluminum arm welded to a heavy cast aluminum plate. Zinc plated steel backing plate is provided for insertion inside the pole for structural support. Two stainless steel C" hex bolts are provided for attachment to pole. Fixture trunnion attaches to a cast aluminum swivel disc with a stainless steel hex head bolt (provided). The swivel disc provides 360Z fixture rotation and comes equipped with two recessed C" stainless steel set point screws for locking fixture at the desired position. Fixture cord enters arm through a strain relief bushing. A cast aluminum end cap provides access to field splice connections. Mounts to 4" minimum square pole.
Cat. No.:
SPR3-X
Side Pole Mount Cat. No. includes pole dia. and finish. For round poles, specify X pole dia. and add finish. Mounts to 3", 3K", 4", 5" or 6" O.D. round poles. Example: SPR3-4/BL-P for 4" Round Pole
Extruded aluminum arm welded to a heavy cast aluminum plate with a rounded back to match the round pole. Zinc plated steel backing plate is provided for insertion inside the pole for structural support. Two stainless steel C" hex bolts are provided for attachment to pole. Fixture trunnion attaches to a cast aluminum swivel disc with a stainless steel hex head bolt (provided). The swivel disc provides 360 fixture rotation and comes equipped with two recessed C" stainless steel set point screws for locking fixture at the desired position. Fixture cord enters arm through a strain relief bushing. A cast aluminum end cap provides access to field splice connections. Mounts to 3", 3K", 4", 5", or 6" round poles.
KIM LIGHTING 87
86
KIM LIGHTING
AFL30
Ordered Separately. See pages 84-87 for complete ordering information.
Housing: One piece die-cast low copper aluminum in a cylindrical shape with integral cooling fins over the entire length and B" minimum wall thickness. One piece extruded and vulcanized silicone gasket between housing and door frame concealed when fixture is closed. Concealed integral cast slip hinges with stainless steel pins. The housing is secured to the electrical compartment by four stainless steel hex head bolts and sealed by a one piece silicone gasket. Door Frame: One piece die-cast low copper aluminum with integral cooling fins, B" minimum wall thickness, mates with housing to create a continuous cylindrical shape. Concealed integral cast slip hinges allow removal without tools. Removable stop-arm provided to limit door frame opening. F" thick clear tempered glass lens is sealed to the lens frame by a one piece molded silicone gasket. Door frame secures to housing by four stainless steel recessed captive allen-head screws. Four tapped and plugged holes provided for attachment of options. Ballast Compartment: Heavy wall cast aluminum body and cover. Access cover secured with four stainless steel hex socket cap screws and provided with hanger wire for support during servicing. Trunnion: High strength formed steel trunnion, J" thick x 3K" wide, with Super TGIC thermoset polyester powder coat (color to match fixture) applied over an electro-zinc plate. The trunnion attaches to the fixture by two K" hex head stainless steel black oxide bolts with lockwashers through two cast aluminum swivel caps. Each swivel cap is equipped with two recessed C" stainless steel set point screws for locking fixture to the selected aiming angle. Fixture can be adjusted 235 front-to-back and is 360 rotatable. Reflector Assemblies: Interchangeable in all seven AFL30 models. Specular Alzak aluminum optical components rigidly mounted in a clear anodized aluminum frame which attaches to housing as a one piece assembly. Sockets are pulse rated 4KV porcelain mogul base for 1000 watt MH, and pulse rated 5KV porcelain mogul base for 750 watt HPS and PMH. Electrical Components: All electrical components are UL and CSA recognized. High power factor ballast rated -40F starting for HPS and -20F for MH lamp modes. Ballast is pre-wired to a six foot long #16-3 cord, rated -58F. to +221F. Cord entry into the access cover is sealed by a concealed waterproof compression cone grommet. See lamp and electrical data on pages 96-98 for ballast types and characteristics. Finish: Super TGIC thermoset polyester powder coat paint, 2.5 mil nominal thickness, applied over a chromate conversion coating; 2500 hour salt spray test endurance rating. Standard colors are Black, Dark Bronze, Light Gray, Platinum Silver or White. Custom colors are available and subject to additional charges, minimum quantities and longer lead times. Consult representative. Certification: UL Listed to U.S. and Canadian safety standards for wet locations. Fixture manufacturer shall employ a quality program that is registered to ISO 9001 standard. CAUTION: Fixtures must be grounded in accordance with local codes or the National Electrical Code. Failure to do so may result in serious personal injury. Optional Photocell (A30 - A35): Ordered assembled with fixture. Factory installed with flush sensor on side of housing. Select photocell with same line volts as fixture. CAUTION: Use only in locations where adjacent lighting will not affect operation of photocell. Barn Doors (BD2): Extruded aluminum doors with anti-reflection baffles. Each door is hinged to a cast aluminum frame, and locks by set screws. Doors are individually removable. Barn Door assembly mounts to predrilled door frame holes. CAUTION: Not recommended for ground mounted fixtures in vandal prone areas. Fixed Hood (FH2): Formed A" thick aluminum. Mounts to predrilled door frame holes. Can be mounted along the top or bottom of the fixture to shield the lamp and lens from view. Provides moderate shielding for ground mounted fixtures next to walkways, drive-ways or roadways. Full Shield (FS2): Formed A" thick x 8" deep aluminum. Mounts to predrilled lens frame holes and provides complete shielding around the perimeter of lens opening. CAUTION: Do not use full shield in locations where leaves and trash can collect inside shield. Grid Louver for AFL34 (GL8): Formed A" thick aluminum. Mounts to predrilled door frame holes. Provides glare control for AFL34 while maintaining beam efficiency and uniformity. NOTE: For use with AFL34 only.
18L"
6" 13L"
KIM LIGHTING
2 4
18L"
8" 13L"
18L"
4" 13L"
12" 7L"
14L" 10"
Grid Louver for AFL35 and AFL36 (GL9): Formed A" thick aluminum. Mounts to predrilled door frame holes. Provides glare control for AFL35 and AFL36 while maintaining beam efficiency and uniformity. NOTE: For use with AFL35 and AFL36 only.
18L"
4" 13L"
R.
DETAIL
3" DIA.
Aiming Ranges
Reference symbol for fixture aiming range when mounted on the option as shown. This range is in the vertical plane and does not necessarily apply to all conditions. See page 88 for full aiming range without mounting options.
0 Vertical 40 185
1 AFL31
lamp position (base up) lamp position 34, 35, 36 lamp position (base down) lamp position
2 AFL32
Trunnion
The standard trunnion mounted on either the SMT3, WM3, SPS3, SPR3-X, MM-2B or MM-3E provides aiming between -40 to 185 off vertical.
3 AFL33,
4 AFL37
AIMING RANGE May be limited by selected mounting option as shown on pages 90-92
88
KIM LIGHTING
KIM LIGHTING
89
AFL30
Ordered Separately. See pages 84-87 for complete ordering information.
Side Pole Mount Tenon for Square Poles (SPS3): Extruded aluminum arm welded to a heavy cast aluminum plate. Zinc plated steel backing plate is provided for insertion inside the pole for structural support. Two stainless steel C" hex bolts are provided for attachment to pole. Fixture trunnion attaches to a cast aluminum swivel disc with a stainless steel hex head bolt (provided). The swivel disc provides 360Z fixture rotation and comes equipped with two recessed C" stainless steel set point screws for locking fixture at the desired position. Fixture cord enters arm through a strain relief bushing. A cast aluminum end cap provides access to field splice connections. Mounts to 4" minimum square pole.
4"
7"
Component EPA: 0.3 Side Pole Mount Tenon for Round Poles (SPR3): Extruded aluminum arm welded to a heavy cast aluminum plate with a rounded back to match the round pole. Zinc plated steel backing plate is provided for insertion inside the pole for structural support. Two stainless steel C" hex bolts are provided for attachment to pole. Fixture trunnion attaches to a cast aluminum swivel disc with a stainless steel hex head bolt (provided). The swivel disc provides 360 fixture rotation and comes equipped with two recessed C" stainless steel set point screws for locking fixture at the desired position. Fixture cord enters arm through a strain relief bushing. A cast aluminum end cap provides access to field splice connections. Mounts to 3", 3K", 4", 5", or 6" round poles.
4"
Single Mount Tenon (STM3): Heavy cast aluminum slipfitter contains four recessed C" stainless steel allen head set point screws for mounting fixture to a 2" pipe-size tenon (2C" O.D. x 4J" min. length). The slipfitter assembles to the fixture trunnion by two concealed stainless steel hex head bolts. The integral cast aluminum splice compartment and gasketed cast aluminum cover house the field-splice and ground connections. The fixture cord (supplied) enters through the splice-compartment side-wall and secures by a strain relief bushing.
7"
13"
4"
Wall Mount (WM3): Extruded aluminum welded to a heavy cast aluminum plate with two K" mounting holes. Fixture trunnion attaches to a cast aluminum swivel disc with a L" stainless steel hex head bolt (provided). The swivel disc provides 360 fixture rotation and comes equipped with two recessed C" stainless steel set point screws for locking fixture at the desired position. Fixture cord enters into arm through a strain relief bushing. A cast aluminum end cap provides access to field splice connections.
4J"
Twin Mount Tenon (MM-2B): Extruded aluminum support continuously welded to a heavy cast aluminum slipfitter hub which cradles the arm for strength. The slipfitter hub contains four recessed C" stainless steel allen head set point screws for mounting to pole with 2" pipe size steel tenon (2C" O.D. x 4J"). Fixture trunnion attaches to a cast aluminum swivel disc with a L" stainless steel hex head bolt (provided). The swivel disc provides 360 fixture rotation and comes equipped with two recessed C" stainless steel set point screws for locking fixture at the desired position. Fixture cords enter into arm through strain relief bushings. A cast aluminum end cap on each end provides access to field splice connections. CAUTION: Approved for mounting to poles with steel tenons only.
33"
25"
8"
The included Wall Embedment Bracket (WEB) provides C-16 bolt receptacles welded in a galvanized re-bar cage for casting into pouredin-place concrete walls. Bolt receptacles receive fixture attachment bolts.
Beam Angle (50% of max.) 139.5H x 96.9V 136.0H x 77.5V 132.0H x 77.6V
I.T.L. Iso Test No. Pg. 44835 45219 44834 217 217 217
7H x 7V 32,817 (54.5H x 36.0V) 149.7H x 144.5V 7H x 7V 26,689 (54.7H x 31.3V) 148.1H x 135.5V 7H x 7V 36,162 (53.1H x 21.1V) 165.3H x 143.0V
2 2
All Initial Lumen values shown are approximate and may vary from one manufacturer to another. Consult lamp manufacturers data for exact lumen and life data. Beam Angle: Horizontal and vertical beam spreads interpolated due to no valid I.E.S. standard.
Lamp Initial Watts Lumens3 750 750 1000 110,000 68,000 110,000
I.E.S. Type
Maximum Candlepower
4
Field Angle (10% of max.) 123.9H x 81.2V 132.5H x 86.2V 133.1H x 80.8V
Beam Angle (50% of max.) 78.2H x 16.9V 78.4H x 17.3V 77.6H x 16.4V
I.T.L. Iso Test No. Pg. 44838 45220 44837 223 223 223
750PMH BT-37 clear mogul base 1000MH BT-37 clear mogul base
4 4
All Initial Lumen values shown are approximate and may vary from one manufacturer to another. Consult lamp manufacturers data for exact lumen and life data. Field Angle: Horizontal and vertical field spreads interpolated due to no valid I.E.S. standard.
25"
8"
Lamp HIGH PRESSURE SODIUM 750HPS BT-37 clear mogul base METAL HALIDE 750PMH BT-37 clear mogul base 1000MH BT-37 clear mogul base
Lamp Initial Watts Lumens5 750 750 1000 110,000 68,000 110,000
I.E.S. Type
Maximum Candlepower
Beam Angle (50% of max.) 104.6H x 67.0V 45.5H x 42.3V 104.0H x 54.7V
I.T.L. Iso Test No. Pg. 44841 45221 44840 229 229 229
7V x 6V 49,020 (38.5H x -24.4V) 140.0H x 122.3V 7H x 6V 41,374 (35.9H x -22.4V) 138.7H x 121.4V 7H x 6V 56,888 (39.6H x -15.1V) 140.3H x 127.1V
All Initial Lumen values shown are approximate and may vary from one manufacturer to another. Consult lamp manufacturers data for exact lumen and life data.
I.E.S. Type
Maximum Candlepower
Beam Angle (50% of max.) 41.4H x 45.7V 44.9H x 38.4V 46.8H x 42.4V
I.T.L. Iso Test No. Pg. 44844 45222 44843 235 235 235
110,000 6H x 6V 86,242 (5.9H x -15.6V) 124.4H x 100.4V 68,000 7H x 6V 61,660 (6.8H x -12.6V) 132.5H x 101.1V
All Initial Lumen values shown are approximate and may vary from one manufacturer to another. Consult lamp manufacturers data for exact lumen and life data.
NOTE: For lamp/ballast information outside of the U.S.A. and Canada, please consult your local Kim representative. WARNING: All fixtures must be grounded in accordance with local codes or the National Electrical Code. Failure to do so may result in serious personal injury. Lamps by others.
92
KIM LIGHTING
KIM LIGHTING
93
Lamp Initial Watts Lumens7 750 750 1000 110,000 68,000 110,000
I.E.S. Type
Maximum Candlepower
Field Angle (10% of max.) 93.4H x 79.0V 49.4H x 55.7V 53.2H x 64.4V
Beam Angle (50% of max.) 22.8H x 37.9V 21.5H x 24.9V 22.7H x 28.2V
I.T.L. Iso Test No. Pg. 44847 45223 44846 241 241 241
All Initial Lumen values shown are approximate and may vary from one manufacturer to another. Consult lamp manufacturers data for exact lumen and life data.
Lamp Initial Watts Lumens8 750 750 1000 110,000 68,000 110,000
I.E.S. Type
Maximum Candlepower
Field Angle (10% of max.) 19.1H x 60.0V 16.8H x 37.1V 16.7H x 49.2V
Beam Angle (50% of max.) 6.3H x 16.7V 8.9H x 16.9V 7.8H x 16.1V
I.T.L. Iso Test No. Pg. 46791 46792 49793 247 247 247
All Initial Lumen values shown are approximate and may vary from one manufacturer to another. Consult lamp manufacturers data for exact lumen and life data.
I.E.S. Type
Maximum Candlepower 72,528 (0.0H x 0.0V) 39,957 (0.0H x 0.0V) 65,650 (3.0H x 1.5V)
Field Angle (10% of max.) 134.1H x 89.6V 140.3H x 90.6V 140.6H x 86.7V
Beam Angle (50% of max.) 91.7H x 21.3V 99.1H x 25.1V 98.5H x 21.7V
I.T.L. Iso Test No. Pg. 50366 50365 50364 253 253 253
110,000 7H x 5V 68,000 7H x 5V
110,000 7H x 5V
All Initial Lumen values shown are approximate and may vary from one manufacturer to another. Consult lamp manufacturers data for exact lumen and life data.
NOTE: For lamp/ballast information outside of the U.S.A. and Canada, please consult your local Kim representative. WARNING: All fixtures must be grounded in accordance with local codes or the National Electrical Code. Failure to do so may result in serious personal injury. Lamps by others.
94
KIM LIGHTING
Asphalt, clean Bluestone, Sandstone Brick, dark buff Brick, light buff Brick, dark red Cement Concrete Earth, average Glass, clear Glass, reflective
Applications Assistance Kim Lighting utilizes the latest computer technology and software to provide specifiers with reliable evaluations of lighting system performance. Kim can analyze a proposed luminaire layout or provide recommendations based on performance criteria. Hard copies of plans can be sent directly to the Kim Applications Department via fax, express or regular mail. Any .dwg or .dxf file can be transmitted via modem or email (kimapps@kimlighting.com), or placed on diskette, CD ROM or Zip disk, and forwarded to Kim Lighting c/o Kim Apps.
Glass, tinted Granolite Pavement Grass, dark green Gravel Macadam Slate, dark clay Snow, new Snow, old Vegetation, average White Marble White Paint, new White Paint, old
Photometric Files Kim photometric files are available free in both electronic and hard copy format. Electronic photometric files include .pdf file format pages for printing and .ies files for use in lighting calculation software. The complete .ies / .pdf library is available on CD ROM and on the internet at www.kimlighting.com.
258
KIM LIGHTING
NATURAL COSINES
KIM LIGHTING 259
ARCHITECTURAL FLOODLIGHTS
CFL AFL10 AFL20 AFL30
Because of a continuing product improvement program, Kim Lighting reserves the right to change specifications without notice.