BILL NO. 3.0 : MECHANICAL WORKS B) AIR-CONDITIONING AND VENTILATION SYSTEM B.Q Amount (RM) (RM) (A) 1.

0 Air Conditioning System Supply, deliver, install, test, commission and maintain the following complete AirConditioning System Works installation complete with indoor and outdoor units, 1.1 control valves, supports, condensate pipes, switches, thermostat, wireless remote switch, refrigerant pipeworks with insulation, bracket, electrical cable & cabling, starter, control panel and all works to complete the installation :(Approved Make: York, Carrier, LG) a) Single Split Unit - Passenger Hall 2 nos 35,000 Btu/Hr (Ceiling Cassette Type) (FCU 1 & FCU 2, ACU 1 & ACU 2) b) Single Split Unit - Booking Office 1 no 19,500 Btu/Hr (Wall Mounted Type) (FCU 3, ACU 3) c) Single Split Unit - Station Manager's Office 1 no 27,000 Btu/Hr (Wall Mounted Type) (FCU 4, ACU 4) Nos. 2 4,800.00 9,600.00 (B) (C) (D)=(B)x(C)

Unit Qty Item Description

Unit Rate

No.

3,700.00

3,700.00

No.

4,200.00

4,200.00

d) Single Split Unit - VIP Room 1 no 18,000 Btu/Hr (Wall Mounted Type) (FCU 5, ACU 5) e) Single Split Unit - Fibrerail Room 2 nos 18,000 Btu/Hr (Wall Mounted Type) (FCU 6 & FCU 7, ACU 6 & ACU 7) f) Single Split Unit - Driver's Room 1 nos 13,000 Btu/Hr (Wall Mounted Type) (FCU 8 & ACU 8)

No.

3,500.00

3,500.00

Nos.

3,500.00

7,000.00

Nos.

1,850.00

1,850.00

g) Single Split Unit - MUJ Office 1 nos 13,000 Btu/Hr (Wall Mounted Type) (FCU 9 & ACU 9) h) Single Split Unit - Male Surau 1 no 18,000 Btu/Hr (Wall Mounted Type)

Nos.

1,850.00

1,850.00

No

3,500.00

3,500.00

Sub-Total Carried Forward to Next Page

(RM)

Sub-Total Brought Forward

(RM) 35,200.00

i)

Single Split Unit - Female Surau 1 no 18,000 Btu/Hr (Wall Mounted Type) (FCU 11, ACU 11)

No

3,500.00

3,500.00

1.2

Supply, deliver, install, test, commission the complete condensate drain pipe for ACU/FCU unit for : Lot Lot Lot 2 2 2 2,807.00 2,809.00 2,811.00 5,614.00 5,618.00 5,622.00

a) Signal Relay Room b) Communication Room c) Battery Room Supply, deliver, install, test, commission and main of electrical starter panel, 1.3 control cabling, HDG trunking, GI conduit, card interfacing, control wiring and all accessories for air cooled split units for the following area. a) Fibrerail Room b) Signal relay Room c) Communication Room d) Battery Room

Lot Lot Lot Lot

1 1 1 1

Included N/A N/A N/A

Sub-Total Carried Forward to Next Page

(RM)

20,354.00

Sub-Total Brought Forward

(RM)

2.0 Mechanical Ventilation System Supply, deliver, install, test, commission and maintain of the following mechanical ventilation system: 2.1 a) Exhaust fans complete with motors, flexible joint, supports, gravity damper, spring isolators, tag numbers, wiring and all accessories to complete. Battery Room EAF-1 (1000cfm, propellar fan) No. 1 N/A

b) Male Toilet 1 EAF-2 (1250cfm, propellar fan) c) Female Toilet 1 EAF-3 (1250cfm, propellar fan) d) Male Toilet 2 EAF-4 (1250cfm, propellar fan) e) Female Toilet 2 EAF-5 (1250cfm, propellar fan)

No.

1,200.00

1,200.00

No.

1,200.00

1,200.00

No.

1,200.00

1,200.00

No.

1,200.00

1,200.00

Total Carried to Summary - MECHANICAL WORKS

B)

(RM)

4,800.00