Low-voltage electrical installation design software
Ecodial V3.38 complies with the latest electrical standards, bringing LV installation design software to a new level of performance.
New standards
Ecodial V3.3 series have been approved by the UTE. It can be used to produce design les complying with: b the CENELEC R 064-003 European calculation guide b IEC 364 installation standards. Any changes or amendments to these standards will be covered by software updates made available through your product support and/or update contract.
You create your project with all the necessary general information: b one window to enter project data (project name, customer name, etc.) b another for the general electrical installation characteristics used for the calculations (earthing arrangement, cascading, etc.) Default values can be modied and saved for future projects. All this information is used in the subsequent steps of the design process and for the printout of the project le. It can be modied at any time.
Higher performance
b Adapts to user practices for maximum effectiveness b Perfect project design les every time b Complete calculations
Operating principles
Build your installation diagram quickly and easily by using standard electrical symbols from the toolbox (e.g. transformer + conductor + protection). You can even customise the toolbox by adding your own group of symbols to the library.
Circuit default value
Power sum
Diagram
Schneider Offer
Association guide
Calculation
Calculation result
Print and Export project
Display curves
b Fupact offer is perfectly integrated into Ecodial In Ecodial V3.38, the complete range of Fupact is integrated: Fupact INF., Fupact ISFL and Fupact ISFT. According to the Fupact offer, users can choose their standards of fuses (BS, Din or NFC). Ecodial V3.38 also takes Fupact discrimination principles into account. Now, Ecodial V3.38 brings to the users a wide choice of fuses: v Range: Fupact, GK1, GS1, LS1, Multi 9, Diazed, aM, gG, gM v Fuse-Combination Unit type: Switch disconnector, disconnector, without FCU v Fuse type (standard): DIN (or NH), NFC, BS v Fuse model: aM, gG, gM, Diazed v New representations:
Disconnector
b Variable speed integrated Ecodial V 3.37 already carried out the new products of the Altivar range: Altivar 11, 21, 31, 38, 61, 71. Ecodial V3.38 now also offers the 08, 28 & 68 Altivar series. These new products enrich the motor starter catalogue. Users are able to choose between direct on-line, start delta, soft starters and variable speed drives. b Among other features v Reminder: A.52-10 to 13 IEC60364 table (current-carrying capacities in amperes) doesnt apply any rated current value for CSA under 25 mm2 for F and G installation methods. Now Ecodial calculates and optimises all CSA if the local installation standard allows it. v The maximum voltage drop authorised by the IEC60364 standard is for information only. In Ecodial V3.38, the users are allowed to enter their own value. However, if the voltage drop in the cable is greater than the value recommended by the standard, a message is displayed. v RCD protection for nal circuits supplying sockets may be present on the circuit with the socket or on an upstream circuit. According IEC 60364 standard, Ecodial does not require additional RCD protection for nal circuits supplying sockets. v LV/LV transformer: Ecodial accepts all primary voltages and gives more information into the calculation result like Transformer R phase, Transformer X phase, Primary ampere rating and Secondary ampere rating.
For further details concerning Ecodial V3.38, ask your Schneider Electric representative for a free demonstration.
b Recommended conguration b PC with Pentium III processor 700 MHz or equivalent b 128 Mb RAM b System: Windows 2000, XP b Screen: 1024x768 pixels (17' screen) or wider b Compatible printer
As standards, specications and designs change from time to time, please ask for conrmation of the information given in this publication.