32 stations per segment (maximum of 64 on all segments) Unlimited in tree-structured architectures. Limited to 5 cascaded segments (4 cascaded electrical/optical repeaters). The link between 2 network stations can cross up to 4 electrical or optical repeaters (TSX FP ACC6 or TSX FP ACC8M) 1000 m maximum for one electrical segment without repeater 5000 m maximum from end to end (5 segments) 3000 m between 2 optical repeaters From a T-junction, via a double pair tap link cable (TSX FP CC iii) or by two-way connection to the trunk cable (TSX FP CA iii) Possible to connect 127 networks together
Length of network
Tap links
Multinetwork
Services
COM
Distributed database : 128 words maximum (0 or 4 words per station) TSX/PMX model 40 PLCs have 0 or 4 common words for station addresses 0 to 31 Note : TSX 17-20 micro-PLCs have 0 or 4 common words for station addresses 0 to 15, TSX Micro/Premium PLCs have 0 or 4 common words for addresses 0 to 31 Point-to-point requests with confirmation : 128 bytes maximum, can be used by all stations (limited to 32 bytes for the TSX 17-20 micro-PLC)
UNI-TE
Application-to-application Point-to-point messages : 128 bytes maximum between two stations (limited to 32 bytes for the TSX 17-20 micro-PLC) Telegram Point-to-point priority messages : 16 bytes maximum between two TSX/PMX model 40 or TSX Micro/Premium stations (the TSX 17-20 micro-PLC cannot use the telegram service) Control characters in each frame and acknowledgment of point-to-point messages conforming to NF C 46-603 standard
Security
Monitoring
Network diagnostics can be accessed via FTX 417, FTX 517, CCX 7 terminals or PC compatibles, running NETDIAG software
42704/2
Te
Performance
The operating principle of a FIPWAY network gives guaranteed, constant network cycle times whatever the traffic and number of stations (2 to 64). This enables the FIPWAY network to be updated (addition or removal of stations) without changing the performance. Maximum transmission time i Telegrams (TLG) Priority application messages are transmitted in less than 10 ms (one telegram per station). i Common words (COM) The database of common words is updated every 40 ms. i UNI-TE (TXT) message handling UNI-TE or standard application-to-application messages are normally transmitted in less than 80 ms (40 ms for stations with addresses below 32). When there is a large amount of traffic, some messages can wait for several cycles before being transmitted. The network characteristics enable a maximum of 210 messages of 128 bytes per second to be transmitted. With such network characteristics, the response time at application level depends almost exclusively on the processing capacity of the devices which are connected. For example, the remote loading of a 50 K word program takes less than two minutes on a network with normal load.
CT1 = Cycle time of device 1 CTN = Cycle time of FIPWAY network CT2 = Cycle time of device 2
Action
The response time must be evaluated by the designer of each application in relation to the devices connected. The processing time of a device can vary from one to two cycle times as a function of asynchronous operation.
Use in multinetwork configuration The FIPWAY network is integrated in the X-WAY architecture in the same way as TELWAY and ETHWAY networks. The multinetwork architecture ensures transparency. This enables any device to address any other device in the architecture. This inter-network communication includes UNI-TE services and application-to-application exchanges.
ETHWAY
CCX 7
The TSX/PMX model 40 version V5 bridge PLC must have an application program which is as small as possible. It should not be used for sequential processing.
FIPWAY
TSX 17
TSX 17
Te
42704/3
Model 40 PLCs
TSX/PMX PLCs can be connected to the FIPWAY bus in 2 ways : i FIPIO/FIPWAY port integrated as standard in TSX P47 415 and TSX/PMX P47/107 455 processors. The choice of FIPWAY or FIPIO connection is made by software configuration. i TSX FPM 100 module including the FIPWAY connection PCMCIA card (compatible with TSX/PMX model 40 version V5 processors, see below).
TSX P47 415 and TSX/PMX P47/107 455 processors with integral FIPIO/FIPWAY port
The front panel comprises : 1 Indicator lamps : - RUN lamp : program running - CPU lamp : processor fault - MEM lamp : memory fault - I/O lamp : I/O fault - FIP lamp : FIPWAY link fault 2 Slot for the user memory cartridge 4 3 Connector for terminal port (20 mA current loop) 4 Connector for connection to FIPWAY bus : this also connects local I/O extension configurations or a remote I/O module TSX LES 65/75 cable connector to be ordered separately.
1 2 3
TSX FPM 100 module package The FIPWAY TSX FPM 100 module package is compatible with the following version V5 processors :
P47 405/415 0
P47 425/455 1
P67 425/455 2
P87/107 425/455 4
The TSX FPM 100 module is made up of : 1 1 TSX MPM 100 reception module supporting a slot 2 for a type III PCMCIA communication card 3 A FIPWAY TSX FPP 20 PCMCIA card 2 3 Connection equipment provided with the TSX FPM 100 package : - a TSX FP ACC 4 T-junction for connection to the network - a cable (length 1 m) for connecting the PCMCIA card to the subscriber socket connector on the TSX FP ACC 4 T-junction
42704/4
Te
1 2 3 4 5 6 7
1 An earth terminal 2 A male 9-way SUB-D connector for connection to the bus 3 A removable cover for accessing the network/station coding system 4 A COM lamp (yellow) : logical module connection established 5 A DEF lamp (red) : module fault 6 A RUN lamp (green) : module ready 7 A male 9-way SUB-D connector for connection to the preceding module Note : The TSX FPG 10 module should always be the last extension of the TSX 17-20 PLC. Connection equipment to be ordered separately : TSX FP ACC 2 : connector for daisy chain or tap link connection.
Other devices
FTX 417-40, FTX 517, CCX 77 terminals or PC compatibles i The TSX FPP K 200 M package is used to connect the FTX 417-40 notebook or PC compatibles with a slot for a type III PCMCIA card to the FIPWAY network. i The ISA TSX FPC 10 M bus modules are used to connect FTX 517/CCX 77/ CCX 87 terminals or PC compatibles to the FIPWAY network. When connected to the FIPWAY network, these terminals access all the stations on the X-WAY architecture. This transparent access enables complete installation of networks and buses on the X-WAY architecture as well as the stations connected to it.
FTX 417
FTX 517
Te
42704/5
TSX 7 3 3 3
CCX 77 2
TSX 7
5 1
9 4 a 24/48 V
TSX 17-20 8
5 TSX 17-20 4
TSX FP CA i00 : trunk cable, screened twisted pair 150 (8 mm diameter) for standard environments and indoor use. TSX FP CR i00 : trunk cable, screened twisted pair 150 (8 mm diameter) for harsh environments and outdoor use (see page 42704/9). TSX FP CC i00 : tap link cable, double screened twisted pair 150 indoor use. (8 mm diameter) for standard environments and
2 3
TSX FP CG 0i0 : connection cable, for TSX FPP 10 PCMCIA module card for TSX Micro/Premium PLCs, FTX 507/ 517 terminals and PC compatibles. Connection to the bus is via a 9-way SUB-D connector on the TSX FP ACC 4 T-junction. TSX FP ACC 7 : TSX FP ACC 4 : line terminator, to be installed at both ends of a segment.
4 5
T-junction for connecting the trunk cable and 1 device via a TSX FP CC i00 tap link cable. It also has a female 9-way SUB-D connector for connection of any device to the bus via a PCMCIA card. TSX FP ACC 14 : T-junction in polycarbonate : see page 42704/8. TSX LES 65/75 : TSX FP ACC 6 : cable connector for TSX/PMX model 40 PLCs. Used for address coding. electrical repeater for increasing the number of stations (64 max) and the length of the network by creating an additional segment of up to 1000 m (a maximum of 4 cascaded repeaters giving a network length of 5000 m).
6 7
8 9
TSX FP ACC 2 : female 9-way SUB-D conn ector for connection to the FIPIO bus (connector TSX FP ACC 12 : TSX FP ACC 2 for TSX 17-20 micro-PLC for example). Used for daisy chain or tap link connection. TSX FP ACC 8M : optical/electrical repeater for connecting electrical segments together via a fibre optic link (good withstand when crossing difficult zones) or connecting an optical device. optical jumper (length 2 m) for the optical connection of a TSX FP ACC 8M repeater to a patch panel. The maximum length of the optical fibre (62.5/125) between 2 repeaters is 3000 m.
network wiring test tool. This is used for testing the continuity of the segments, the connections of the various devices and the installation of line terminators. TSX DR FPW E : this manual defines the topology of the FIPIO/FIPWAY network. It is required for setting up and installing the FIPIO/FIPWAY network.
42704/6
Te
TSX 47-40
2048 2048
16 32 56
No No No
96 96 96
56
No
Yes
96
256
2.820
+ +
Description
Composition
Weight kg 0.460
TSX 17-20 micro-PLC module TSX/PMX 47-40 to 107-40 PLC module package (5)
1 extension module
1 TSX MPM 100 reception module 1 TSX FPP 20 FIPWAY PCMCIA card 1 TSX FP CG 010 connection cable 1 TSX FP ACC 4 T-junction 1 TSX DM FPM 100E user's manual 1 TSX DR FPW E reference manual 1 ISA bus card (1/2 format) 1 set of 3" 1/2 diskettes (DOS and OS/2 drivers)
2.500
+
TSX FPM 100E
0.140
(1) Memory capacity in K words. RAM integrated in processor, user memory cartridge and cable connector to be ordered separately, see page 42206/7. (2) The letter E at the end of a reference indicates that the product includes documentation in English. The letter M at the end of a reference indicates that the product includes documentation in English and French. (3) See also PLC coprocessor integrated in operator stations, page 42207/4. (4) Memory capacity in K words. (5) The TSX FPM 100E module package enables the connection of processors with no integral FIPWAY/FIPIO link to the FIPWAY network. For processors with an integral FIPWAY/FIPIO link, simultaneous FIPWAY and FIPIO connections are possible. To use the TSX FPM 100 module under X-TEL V52 software workshop, the software workshop must be installed using the TXT R CTG V6E catalogue package, see page 46200/4.
Te
42704/7
PCMCIA cards for TSX Micro/Premium PLC FIPWAY PCMCIA module for FTX 417-40 or PC compatible
1 FIPWAY type III PCMCIA card 1 FIPWAY PCMCIA card TSX FPP 20 1 set of 3" 1/2 diskettes (DOS 6.i and OS/2 2.i drivers) 1 user's manual
TSX FPP 20
TSX FP ACC 12
0.040
TSX FP ACC 4
0.660
TSX FP ACC 12
TBX FP ACC 10
0.660
Insulated T-junction for connection to the bus (black polycarbonate casing) Line terminator (Order in multiples of 2) Electrical repeater
TSX FP ACC 14
0.120
0.020 0.520
TSX FP ACC 4
Electrical/optical repeater
TSX FP ACC 8M
0.620
TSX FP ACC 14
TSX FP ACC 7
Connect the TSX FPP 20 to the subscriber socket on TSX FP ACC 4 T-junction
1m 3m 3m
15 and 9-way 2 screened twisted pairs SUB-D 150 . connectors Connects the TSX FPC 10M module to the subscriber socket on TSX FP ACC 4 or TBX FP ACC 10 T-junction
Double For electrical/ 2m TSX FP JF 020 0.550 optical fibre optical repeater 62.5/125 (1) The letter M at the end of a reference indicates that the product includes documentation in English and French.
Te
8 mm, 1 Standard environments (2) 100 m screened twisted and indoor use 200 m pair 150 500 m 8 mm, 1 Harsh environments screened twisted and outdoor use pair 150 or in garland (3) 9.5 mm, 1 screened twisted pair 150 , and 1 1.5 mm2 supply pair TBX dust and damp proof I/O modules, for outdoor use, harsh environments or in garland (3) 100 m 200 m 500 m 100 m 200 m 500 m
8 mm, 2 Standard environments (2) 100 m screened twisted and indoor use 200 m pairs 150 500 m
Documentation
(English) Description TSX technical documentation X-WAY reference manual FIPWAY/FIPIO reference manual Installation of integral FIPWAY/FIPIO link on TSX/PMX Manual format CD-ROM Included with product To be ordered separately To be ordered separately TSX Pi74i5E TPMX Pi74i5E TSX Pi74i5E TPMX Pi7455E Reference TSX CD D MTE 01E Weight kg 0.120
Installation of A5 bound TSX FPM 100E TSX DM FPM 100E 0.140 FIPWAY module package (1) FIPWAY network characteristics and performances can only be guaranteed if the above TSX FP accessories are used. (2) Standard environments : - no particular environmental restrictions - operating temperature between + 5 C and + 60 C - fixed installations. (3) Harsh environments : - withstand to hydrocarbons, industrial oils, detergents, soldering sparks - up to 100% humidity - saline environment - wide temperature variations - operating temperature between - 10 C and + 70 C - mobile installations. Use in garland : radius of curve = 10 times the cable diameter (either 80 or 95 mm). For other particular restrictions, please consult your Regional Sales Office.
Dimensions
TSX FP ACC 4 TBX FP ACC 10 TSX FP ACC 6 TSX FP ACC 8M TSX FP ACC 14
80 = 50 (1) =
20
175 =
= 20
27
=
160 2x5,5
20
65 80
50 83
RUN DEF
RUN DEF
20
20
20
2x5,5
25
25
50 79
Te
42704/9
68