H1080 Serial
7.
Power On command will not work for 1 minute after the power off command triggered. CR : Carriage Return.
Company Confidential 47
VIVITEK__________________
Delta________________ 2009/09/30
H1080 Serial
Company Confidential 48
VIVITEK__________________
Delta________________ 2009/09/30
H1080 Serial
Data Range
ITEM Brightness Contrast Color Tint Scaling Color Temperature Projection Mode
Set Data Range 0 ~ 100 0 ~ 100 0 ~ 100 0 ~ 100 0: Auto 1: 16:9 2: 4:3 3:4:Letter Box 5 :Real 3:Cool4:Cooler5:High Cool 0:Front table 1:Front 2:Ceiling3:Rear table4:Rear+ Ceiling
Attention: Data range may be different for different models Example 1. Adjust Brightness value to 100 Send Command : ~sB100CR Example 2. Adjust Color Temperature to Warm Send Command : ~sT2CR
Company Confidential 49
VIVITEK__________________
Delta________________ 2009/09/30
H1080 Serial
ASCII ~ q V CR ~ q P CR ~ q S CR ~ q L CR ~ q B CR ~ q C CR ~ q R CR ~ q N CR ~ q A CR ~ q T CR ~ q J CR
HEX 7Eh 71h 56h 0Dh 7Eh 71h 50h 0Dh 7Eh 71h 53h 0Dh 7Eh 71h 4Ch 0Dh 7Eh 71h 42h 0Dh 7Eh 71h 43h 0Dh 7Eh 71h 52h 0Dh 7Eh 71h 4Eh 0Dh 7Eh 71h 41h 0Dh 7Eh 71h 54h 0Dh 7Eh 71h 4Ah 0Dh
ITEM Software Version Power State Input Select Lamp Hours Brightness Contrast Color (Video) Tint (Video) Scaling Color Temperature Projection Mode
Response Message examples .. On Off RGB HDMI1 HDMI2 Video S-Video Component 2000 100 100 100 100 Auto 16:9 4:3 LetterBox Rear 0:LAMP Native 1:Warm 2:Normal 3:Cool4:Cooler5:High Cool Front table Front Ceiling Rear table Rear+ Ceiling
Example 1.
Example 2.
Get Brightness value Send Command : ~qBCR Response : 100 Get Color Temperature Send Command : ~qTCR Response : Warm
VIVITEK__________________ Delta________________ 2009/09/30
Company Confidential 50
H1080 Serial
7-8.
Company Confidential 51
VIVITEK__________________
Delta________________ 2009/09/30
H1080 Serial
7-9-3 Setting the HyperTerminal parameter Step 1. Type the connection name .
Company Confidential 52
VIVITEK__________________
Delta________________ 2009/09/30
H1080 Serial
Step2. Choose the COM port for your RS232 Cable connected to.
Step3. In Bits per second choose 9600 and in Flow control choose None
Step4.
Company Confidential 53
H1080 Serial
Company Confidential 54
VIVITEK__________________
Delta________________ 2009/09/30
H1080 Serial
Step7. Mark Send Line ends with line feeds and Echo typed characters locally and click OK bottom to complete setting.
Company Confidential 55
VIVITEK__________________
Delta________________ 2009/09/30