You are on page 1of 4

Models:

14/20RES

Multi-Fuel LP Vapor/Natural Gas

Standard Features
D RDC Residential Digital Control d One digital controller manages both the generator set

d d d

and transfer switch functions (with optional Model RRT transfer switch) Designed for todays most sophisticated electronics Electronic speed control responds quickly to varying household demand Digital voltage regulation protects your sensitive electronics from harmonic distortion and unstable power quality LED display shows system status and setup information

D Kohler Command PRO Engine Features

The Kohlerr Advantage


D Best-in-Class Power Quality

d Kohler Command PROr OHV engine with hydraulic

Kohler home generators provide industry-leading voltage and frequency regulation along with ultra-low levels of harmonic distortion for the best generator power quality you can get to protect your prized electronics.
D Extraordinary Reliability

valve lifters for reliable performance without routine valve adjustment or lengthy break-in requirements d Powerful, reliable air-cooled performance d Simple field conversion between natural gas and LP vapor fuels while maintaining emission certification
D Designed for Easy Installation d Polymer base eliminates the need for a concrete

Kohler is known for extraordinary reliability and performance and backs that up with an industry-leading 5-year or 2000 hour warranty.
D Powerful Performance

mounting pad, reducing installation time and cost


d Hinged, locking roof d Fuel and electrical connections through the enclosure

Exclusive Powerboostt technology provides greater starting power. The Kohler 14 kW generator can easily start and run a 5 ton air conditioner without dropping power to other appliances an unheard-of feat in other generators of this size.*
D Exclusive 100% Corrosion-Proof Enclosure

wall eliminate the need for stub-ups through the bottom


d Load connection terminal block allows easy field wiring d Designed for outdoor installation only D Certifications d Meets emission regulations for U.S. Environmental

Unlike aluminum or steel enclosures, the bold new Kohler design is completely corrosion proof, even in harsh seaside environments, and is impact-resistant even at --34_ C (--30_ F).
D Faster Response

Kohler home generators restore power to your home 2-3 times faster than competitive models.
D Quiet Operation

Protection Agency (EPA) phase 2 small off-road engines and CA 2006 and later LSI engines with both LP vapor and natural gas d UL 2200 listed (60 Hz model) d CSA certification available (60 Hz model) d Approved for stationary standby applications in locations served by a reliable utility source

Kohler home generators provide quiet neighborhoodfriendly performance. Now you will experience even quieter operation during the weekly variable-speed exercise with complete system diagnostics.

Generator Ratings
Model 14RES 20RES Voltage 120/240 115/230 120/240 115/230 Phase 1 1 1 1 Hz 60 50 60 50 Alternator 2F5 2F5 2F7 2F7 Standby Ratings Natural Gas LP Gas kW/kVA Amps kW/kVA 12/12 50.0 14/14 10/10 43.5 11/11 18/18 75.0 20/20 13/13 56.5 14/14 Amps 58.3 47.8 83.3 60.8

RATINGS: Standby ratings apply to installations served by a reliable utility source. All single-phase units are rated at 1.0 power factor. The standby rating is applicable to variable loads with an average load factor of 80% for the duration of the power outage. No overload capacity is specified at this rating. Ratings are in accordance with ISO--3046/1, BS5514, AS2789, and DIN 6271. GENERAL GUIDELINES FOR DERATING: ALTITUDE: Derate 4% per 305 m (1000 ft.) elevation above 153 m (500 ft.). TEMPERATURE: Derate 2% per 5.5_C (10_F) temperature increase above 16_C (60_F). Availability is subject to change without notice. The generator set manufacturer reserves the right to change the design or specifications without notice and without any obligation or liability whatsoever. Contact your local Kohler Co. generator distributor for availability. * Check the appliance manufacturers specifications for actual power requirements. Consult a Kohlerr Power Systems professional to calculate your exact residential power system requirements. G4-172 (14/20RES) 1/11d

Application Data
Engine
Engine Specifications Manufacturer Engine: model, type Cylinder arrangement Displacement, cm3 (cu. in.) Bore and stroke, mm (in.) Compression ratio Main bearings: quantity, type Rated RPM 60 Hz 50 Hz Max. engine power at rated rpm, kW (HP) LP vapor, 60 Hz LP vapor, 50 Hz Natural gas, 60 Hz Natural gas, 50 Hz Cylinder head material Valve material Piston type and material Crankshaft material Governor: type Frequency regulation, no load to full load Frequency regulation, steady state Air cleaner type 14RES Kohler CH740 4-Cycle V-2 725 (44) 83 x 67 (3.27 x 2.64) 999 (61) 90 x 78.5 (3.54 x 3.1) CH1000 4-Cycle 20RES

Exhaust
Exhaust System Exhaust temperature exiting the enclosure at rated kW, dry, _C (_F) 14RES 20RES 260 (500)

Lubrication
Lubricating System Type Oil capacity (with filter), L (qt.) Oil filter: quantity, type Oil cooler 14RES 20RES Full Pressure 1.9 (2.0) 2.8 (3.0) 1, Cartridge Integral

9:1 8.8:1 2, Parent Material 3600 3000 17.6 (23.6) 23.0 (30.9) 15.8 (21.2) 20.0 (26.8) 15.3 (20.5) 20.2 (27.1) 13.8 (18.5) 16.8 (22.5) Aluminum Steel/Stelliter Aluminum Alloy Heat Treated, Ductile Iron Electronic Isochronous 0.5% Dry

Fuel Requirements
Fuel System Fuel types Fuel supply inlet Fuel supply pressure, kPa (in. H2O): Natural gas LP Fuel flow rates, Btu/hr. Natural gas LP 193,000 203,000 281,000 340,000 1.2--2.7 (5-11) 1.7--2.7 (7-11) 14RES 20RES Natural Gas or LP Vapor 1/2 NPT

Fuel Pipe Size


Minimum Gas Pipe Size Recommendation, in. NPT 14RES Pipe Length, m (ft.) 8 (25) 15 (50) 30 (100) 46 (150) 61 (200) Natural Gas (193,000 Btu/hr.) 3/4 1 1 1 1/4 1 1/4 LP Vapor (203,000 Btu/hr.) 3/4 3/4 1 1 1 20RES Natural Gas (281,000 Btu/hr.) 1 1 1 1/4 1 1/4 1 1/4 LP Vapor (340,000 Btu/hr.) 3/4 1
1

Engine Electrical
Engine Electrical System Ignition system Starter motor rated voltage (DC) Battery (purchased separately): Ground Volts (DC) Battery quantity Recommended cold cranking amps: (CCA) rating for --18_C (0_F) Group size 14RES 20RES Electronic, Capacitive Discharge 12 Negative 12 1 500 51

1 1/4 1 1/4

Fuel Consumption
Fuel Consumption, m3/hr. (cfh) 14RES Fuel Type % Load 100% 75% 50% 25% 100% LP Vapor 75% 50% 25%
LP vapor conversion factors: 8.58 ft.3 = 1 lb. 0.535 m3 = 1 kg 36.39 ft.3 = 1 gal.

20RES 50 Hz 60 Hz 8.0 6.9 4.6 3.6 3.9 3.1 2.3 1.7 (281) (243) (161) (127) (136) (109) (82) (59) 50 Hz 6.4 5.4 3.9 2.9 2.9 2.4 1.8 1.3 225 189 139 103 102 85 63 47 (175) (148) (108) (84) (74) (68) (53) (40)

60 Hz 5.4 4.7 3.5 2.6 2.3 2.1 1.8 1.2 (193) (163) (124) (93) (81) (75) (60) (45)

4.9 4.2 3.1 2.4 2.1 1.9 1.5 1.1

Natural Gas

Nominal fuel rating: Natural gas: 37 MJ/m3 (1000 Btu/ft.3) LP vapor: 93 MJ/m3 (2500 Btu/ft.3)

G4-172 (14/20RES) 1/11d

Alternator
Alternator Features
D Compliance with NEMA, IEEE, and ANSI standards for

RDC Residential Digital Controller

temperature rise
D Self-ventilated and dripproof construction D Vacuum-impregnated windings with fungus-resistant

epoxy varnish for dependability and long life


D Superior voltage waveform and minimum harmonic

distortion from skewed alternator construction


D Digital voltage regulator with 1.5% no-load to full-load

RMS regulation
D Rotating-field alternator with static exciter for excellent

Controller Features
D Integrated control for the generator set and Kohlerr Model

load response
D Skewed generator construction produces a smooth

RRT transfer switch


D Membrane keypad: d OFF, AUTO, and RUN pushbuttons d Exercise/down arrow pushbutton d Select and arrow buttons for password-protected access

AC waveform

Alternator Specifications
Specifications Manufacturer Output reconnectable Type Leads, quantity Voltage regulator Insulation: Material Temperature rise Bearing: quantity, type Coupling Amortisseur windings Voltage regulation, no-load to full-load RMS One-step load acceptance Peak motor starting kVA @ 240 V: 14RES 20RES 35 40.5 D PowerBoostt Generator 1-Phase Kohler 120/240 2-Pole, Rotating Field 4 Digital NEMA MG1-1.66 Class H Class H 1, Sealed Ball Direct Full 1.5% 100% of Rating D

to system configuration and adjustment menus


d System voltage/frequency selection and engine

configuration
d Voltage, gain, and engine speed adjustment D OFF, AUTO, and RUN LED indicators D LED display: d Scrolling system status display includes engine runtime

Sound Data
Model 14RES 20RES Sound Level at 7 m Low Speed No Load Full Speed No Load 66 dBA 70 dBA 68 dBA 73 dBA D D D D D D D D

hours, battery voltage, generator voltage, engine temperature, and utility voltage * d Crank cycle status d Setup information d Firmware version d Faults d Event history Faults displayed: d Auxiliary fault d Low oil pressure d ATS communication error d Overcrank d High battery voltage d Overfrequency d High engine temperature d Overspeed d Internal faults d Overvoltage d Locked rotor d Speed sensor fault d Loss of generator AC sensing d Underfrequency d Low battery voltage d Underspeed d Low cranking battery voltage d Undervoltage Exercise modes d Unloaded quiet variable-speed exercise with complete system diagnostics d Loaded full-speed exercise (ATS required) Smart engine cooldown senses engine temperature Remote two-wire start/stop capability for optional connection of Model RDT or RSB transfer switches Digital isochronous governor to maintain steady-state speed at all loads Digital voltage regulation: 1.5% RMS no-load to full-load Automatic start with programmed cranking cycle Field-upgradeable firmware [ Front-access mini USB connector for firmware upgrade Front access fuses and mini-breaker

* Model RRT transfer switch required [ Requires Kohlerr SiteTecht software

G4-172 (14/20RES) 1/11d

KOHLER CO., Kohler, Wisconsin 53044 USA Phone 920-457-4441, Fax 920-459-1646 For the nearest sales and service outlet in the US and Canada, phone 1-800-544-2444 KohlerPower.com

Kohler Power Systems Asia Pacific Headquarters 7 Jurong Pier Road Singapore 619159 Phone (65) 6264-6422, Fax (65) 6264-6455

Standard Features
D D D D D D D D D D D D D D 6-amp battery charger (60 Hz models only) Battery cables CARB- and EPA-certified fuel system Corrosion-proof polymer sound enclosure Critical silencer Field-connection terminal block Fuel solenoid valve and secondary regulator Line circuit breaker Multi-fuel system, LP vapor/natural gas, field-convertible Oil drain extension with shutoff valve Premium 5-year limited warranty RDC generator set/ATS controller Rodent-resistant construction Sound-deadening, flame-retardant foam per UL 94, class HF-1

Available Accessories
Communication Accessories - OnCue Homet Generator Management System Electrical System - Battery - Battery heater Fuel System - Gas strainer - Braided stainless steel flexible fuel line Maintenance - Maintenance kit (air and oil filters) - General maintenance literature kit - Overhaul literature kit - Production literature kit Starting Aids - Carburetor heater, 120 VAC (recommended for reliable starting at temperatures below 0_C [32_F ] ) Kohlerr Automatic Transfer Switch - Model RRT, see specification sheet G11-120 - Model RDT, see specification sheet G11-98 - Model RSB, see specification sheet G11-101 - Other Kohlerr ATS Miscellaneous Accessories - __________________________________________ - __________________________________________ - __________________________________________ - __________________________________________
W
NOTE: Dimensions are provided for reference only and should not be used for planning installation. Contact your local distributor for more detailed information.

Generator Set Dimensions and Weights


Overall Size, L x W x H: Weight: 14RES 20RES L 1216 x 665 x 733 mm (48 x 26.2 x 29 in.) 186 kg (410 lb.) 227 kg (500 lb.)

DISTRIBUTED BY:

2010, 2011 by Kohler Co. All rights reserved. G4-172 (14/20RES) 1/11d