1. ELSewedyElectric&SWEG 1 EL Sewedy Electric & SWEG 2. WindTurbinescomponentsandgeneratortypes 3. WindTurbinesdrivesystemsadvantagesand 3 Wi d T bi d i d d disadvantages 4. ComparisonsofWindTurbinesdrivesystems 5. Conclusions 6. Appendix 7. References
www.elsewedyelectric.com
2
www.elsewedyelectric.com
ElsewedyElectric
www.elsewedyelectric.com
www.elsewedyelectric.com
www.elsewedyelectric.com
I TOWERS
SIAGCompanyOverview
www.elsewedyelectric.com
II TURBINES
MTorresCompanyOverview
OneofthemostInnovative EngineeringcompaniesinSpain Startedinthepaperindustries& nowoneoftheleadersin supplyingmachinesforthe aerospaceindustry Atotalof500highskilled employees
MTorresWindDivision MT Wi d Di i i
2001thefirstinnovative 1.5MWprototype MTOIengineering, MTOI engineering manufacturing, development,O&M
www.elsewedyelectric.com
IIIBLADES
WindRotorBladesFactoryinEgypt Stateoftheartproduction State of the art production technologytransferfroma leadingGermanmanufacturer. StateoftheartBladesDesign licensedbyleadingDutchand licensed by leading Dutch and GermanDesigners Thefactorywillbeequipped withthemostadvanced Fiberglassmouldsand Fib l ld d equipmenttoproduce200sets ofbladesinstage1expandable to500sets Nearly500employeesand technicianswillbeemployedin thefirststage
www.elsewedyelectric.com
www.elsewedyelectric.com
10
www.elsewedyelectric.com
11
Electrical P El t i l Power
PowerConverter Transformer Generator (Optional) Grid
Types of Generators
(AC Machines)
www.elsewedyelectric.com
Grid
Motor SubSynch(+veslip) veT ve T Generator Supersynch(veslip)
Generator
Motor
OperatingTorque T
WoundRotor
PermanentMagnet Generator
www.elsewedyelectric.com
15
P=4
P=2
%ofSynchSpeed
www.elsewedyelectric.com
17
AdvantagesofGearedSCIG
Cost (SCIG)isaverypopularmachine,ithasLow specificmass(kg/kW)andsmallerouter diameter(lownumberofpoles)hencelower di t (l b f l )h l cost. Mechanical,Maintenance&Reliability h i l i & li bili Mechanicalsimplicity,robuststructure
www.elsewedyelectric.com
18
DisadvantagesofGearedSCIG
Mechanical,Reliability&Maintenance Agearbox inthedrivetrainisrequired: Electrical&PowerQuality Directlyconnectedtothegrid Directly connected to the grid SCIGwoulddisconnectfromthegrid evenduringquitesmalldisturbances. Theydidnothaveanyfaultride Th did t h f lt id throughcapability, Themachinealwaysrequiresreactive power,anditsvaluecannotbe controlled.Thismakesitimpossibleto supportgridvoltagecontroltherefore nogridsupport, Needdifferentgearboxesfordifferent gridfrequencies50Hz/60Hz Control Nopossibilityofspeedcontrol,onlyapole changeablecanbeused,whichleadstwo rotationspeeds. p Theturbinespeedcannotbeadjustedtothe windspeedtooptimizetheaerodynamic efficiency. efficiency.` Windspeedfluctuationsaredirectly translatedintoelectromechanicaltorque variations(nodampingcontrol),Thiscauses variations (no damping control) This causes highmechanicalandfatiguestressesonthe system(P=T.W)
www.elsewedyelectric.com
19
Directlyconnectedtogrid RotorConnectedtogridviapower converter Agearboxisrequiredinthedrivetrain Variablespeed,Speedcanbecontrolled Variable speed, Speed can be controlled withina+/ 30%aroundsynchronous speed(TheconverterisFeedingor Absorbingpowerfrom/tothegrid) Absorbing power from/to the grid)
ve T Operating Torque T
Motor
www.elsewedyelectric.com
20
Cost Lowspecificmass(kg/kW)andsmallerouterdiameter(lownumberof Low specific mass (kg/kW) and smaller outer diameter (low number of poles)hencelowercost. TheconverterforaDFIGissmall(30%ofratedpower).Thereforeitis cheaperthanforadirectdrivegenerator. h th f di t d i t MorecomplexstructurethanSCIG Electrical&PowerQuality Thereactivepower canbecontrolledbycontrollingtherotorcurrentswith theconverter,thisallowsthesupplyofvoltagesupporttowardsthegrid. Howeverreactivepowerislimitedbytheconverter30%rating. However reactive power is limited by the converter 30% rating. Control DFIGsupportsawidespeedrangeoperation,dependingonthesizeofthe frequencyconverter.TypicallyVariablespeedrangeis+30%aroundthe f t T i ll V i bl d i +30% d th synchronousspeed InDFIG,windgustsleadtovariationsinthespeedwithoutlargetorque variations.
www.elsewedyelectric.com
AdvantagesofGearedDFIG
21
DisadvantagesofGearedDFIG
Mechanical,Reliability&Maintenance Agearboxinthedrivetrainisrequiredwhichshowareliability negativerecord. DFIGhavebrushes,whichneedregularinspectionandreplacement. DFIG have brushes which need regular inspection and replacement Theyareapotentialcauseofmachinefailureandlosses. Electrical&PowerQuality Statordirectlyconnectedtogrid d l d d Accordingtogridconnectionrequirementsforwindturbines,incase ofgriddisturbances,aridethroughcapabilityofDFIGisrequired,so thatthecorrespondingcontrolstrategiesmaybecomplicated. Undergridfaultconditions,ontheonehand,largestatorcurrents resultinlargerotorcurrents,sothatthepowerelectronicconverter g , p needstobeprotected Needdifferentgearboxesfordifferentgridfrequencies50Hz/60Hz
22
www.elsewedyelectric.com
NoGearboxisrequired No Gearbox is required Nodirectconnectiontothegrid, Connectedthroughapowerconverter Theamplitudeandfrequencyofthe suppliedvoltagecanbefullycontrolled Thefluxisfullycontrolledtominimize lossesindifferentoperatingranges Operateinawiderangeofspeedeven toaverylowspeed to a very low speed
www.elsewedyelectric.com
23
AdvantagesofGearlessEESG
Mechanical,Maintenance&Reliability NoGearboxsohighreliability,lessnoise, lesscost, DFIGhavebrushes,whichneedregular DFIG have brushes which need regular inspectionandreplacement.Theyarea potentialcauseofmachinefailureand losses. losses Electrical&PowerQuality Theconverterpermitsflexiblefull control ofactiveandreactivepowerincaseof normalanddisturbedgridconditions.this allowsthesupplyofvoltagesupport towardsthegrid. Thesamegeneratorsuitablefordifferent gridfrequencies50Hz/60Hz Thefullpowerconvertertotally The full power converter totally decouplesthegeneratorfromthe grid.Hence,griddisturbanceshave nodirecteffectonthegenerator no direct effect on the generator Control Theconverteroffersawiderangeof d l l d speedcontrolevenatverylowspeed thereforeahigherenergyyield Theamplitudeandfrequencyofthe voltagecanbefullycontrolledbythe converter EESGhastheopportunitiesof pp controllingthefluxforaminimized lossindifferentpowerranges
www.elsewedyelectric.com
24
DisadvantagesofGearlessEESG
Cost Highspecificmass(kg/kW)andLargeouterdiameter(highnumber ofpoles) henceHighercostandmoreweight.Thisweightis partiallybalancedbytheeliminationofthegearbox. partially balanced by the elimination of the gearbox Theconverteris100%ofratedpower.itismoreexpensivethanfor aDFIG.Thisextracostisbalancedbytheeliminationofthegearbox MorecomplexstructurethanSCIG Mechanical,Reliability&Maintenance Mechanical, Reliability & Maintenance EESGhavebrushes,whichneedregularinspectionand replacement.Theyareacauseofmachinefailureandlosses.
www.elsewedyelectric.com
25
NoGearboxisrequired No Gearbox is required Nodirectconnectiontothegrid, Connectedthroughapowerconverter Theamplitudeandfrequencyofthe suppliedvoltagecanbefullycontrolled Nofluxcontrolandnosliprings becauseofpermanentmagnets Operateinawiderangeofspeedeven toaverylowspeed to a very low speed
www.elsewedyelectric.com
26
AdvantagesofGearlessPMSG
Mechanical,Maintenance&Reliability Theconverterpermitsveryflexiblefull NoGearboxandbrushessohigher controloftheactiveandreactivepowerin reliability,lessnoise,lesscost, caseofnormalanddisturbedgrid improvementinthethermal p conditions.thisallowsthesupplyofvoltage characteristicsofthePMmachinedue supporttowardsthegrid. totheabsenceofthefieldlosses, Control Electrical&PowerQuality Electrical & Power Quality Theconverteroffersawiderangeofspeed Thefullpowerconvertertotally controlevenatverylowspeedthereforea decouplesthegeneratorfromthegrid. higherenergyyield higher energy yield Hence,griddisturbanceshavenodirect Hence grid disturbances have no direct Theamplitudeandfrequencyofthevoltage effectonthegenerator canbefullycontrolledbytheconverter Thesamegeneratorsuitablefor PMSGhastheopportunitiesofcontrolling PMSG h th t iti f t lli differentgridfrequencies50Hz/60Hz / thefluxforaminimizedlossindifferent Noadditionalpowersupplyforthe powerranges magnetfieldexcitation,
www.elsewedyelectric.com
27
DisadvantagesofGearlessPMSG
Cost HighcostofPMmaterialandLargeouterdiameter(highnumberof poles),howeverthisisbalancedthroughalowerspecificmass (kg/kW)andtheeliminationofthegearbox. (kg/kW) and the elimination of the gearbox Theconverteris100%ofratedpower.itismoreexpensivethanfor aDFIG.Thisextracostisbalancedbytheeliminationofthegearbox Mechanical,Reliability&Maintenance DemagnetizationofPMathightempduetoseverloadingorshort circuit. Difficultiestohandleinmanufactureandintransportation,
www.elsewedyelectric.com
28
www.elsewedyelectric.com
29
If in the middle of a desert with hot sandy, and dusty weather or if offshore If the point of common connection in the middle of a complex grid
Annual Energy Yield due to control , reliability and less down time Cost of Kwh (Levelized Energy Cost)
(-) (-)
(+) (+)
(++) (++)
(++) (++)
www.elsewedyelectric.com
30
www.elsewedyelectric.com
31
Conclusions
Themultiple stagegeareddriveDFIGsystemsisstill The multiplestage geared drive DFIG systems is still dominatingthecurrentmarket, Themarketshowsinterestinthedirectdrivesystemswitha fullscalepowerconverter.Newcompaniesrecognizedtheir advantagesandalreadystarted, Weight,sizeandinitialcostarehigherindirectdrivesystems. Weight size and initial cost are higher in direct drive systems Overallefficiency,reliabilityandavailabilityarehigherin directdrivesystemsbecauseofomittingthegearbox, Maintenancecostishigheringeareddrivesystemsspeciallyin rulerarea,desert,andoffshorealsoinhotanddustyweather, ThecostofKWhislessindirectdrivesystems, The cost of KWh is less in direct drive systems Intermsofgridsupportdirectdrivewindturbineswithafull scalepowerconvertermaybemoreeffectiveandless complicatedtodealwithgridrelatedproblems,
www.elsewedyelectric.com
32
Nacelle Front
www.elsewedyelectric.com
33
Nacelle Rear
www.elsewedyelectric.com
34
www.elsewedyelectric.com
35
Appendix
www.elsewedyelectric.com
36
www.elsewedyelectric.com
37
www.elsewedyelectric.com
39
www.elsewedyelectric.com
40
www.elsewedyelectric.com
41
References
H.Polinder,,Sjoerd W.H.deHaan,M.R.Dubois,JohannesG.Slootweg,BasicOperationPrinciplesand ElectricalConversionSystemsofWindTurbines, J.Soens,J.Driesen,R.Belmans,InteractionbetweenElectricalGridPhenomenaandtheWindTurbine's Behaviour,PROCEEDINGSOFISMA2004, H.Li*Z.Chen,OverviewofdifferentwindgeneratorsystemsandtheircomparisonsPublishedinIET RenewablePowerGenerationReceivedon24 January2007Revisedon Renewable Power Generation Received on 24th January 2007 Revisedon 23rd August 2007 doi:10 1049/iet August2007doi:10.1049/iet rpg:20070044, GNewman,SPerera,VGosbell andVSmith,VOLTAGESAGRIDETHROUGHIMPROVEMENT,OFMODERN ACDRIVES:REVIEWOFMETHODSANDACASESTUDY,IntegralEnergyPowerQualityCentre, C.Rahmann,H. J.Haubrich,L.VargasandM.B.C.Salles, InvestigationofDFIGwithFaultRide Through C. Rahmann, H.J. Haubrich, L. Vargas and M. B. C. Salles, Investigation of DFIG with Fault RideThrough CapabilityinWeakPowerSystems,InternationalConferenceonPowerSystemsTransients(IPST2009)in Kyoto,JapanJune36,2009, ,K.S.Sandhu,D.K.Jain ,LVRTofGridInterfacedVariableSpeedDrivenPMSGforWECSduringFault Rajveer Mittal,InternationalJournalofComputerandElectricalEngineering,Vol.1,No.4,October,2009 17938163, Anca D.Hansen*,Nicolaos A.Cutululis*,Poul Srensen*,FlorinIov+,Torben J.Larsen,*Simulationofa flexiblewindturbineresponsetoagridfault,Ris NationalLaboratoryincooperationwithAalborg University, MartaMolinas,Bjarne N M t M li Bj Naess,WilliamGullvik,ToreCageInductionGeneratorsforWindTurbineswith Willi G ll ik T C I d ti G t f Wi d T bi ith PowerElectronicsConvertersintheLightoftheNewGridCodes,Undeland NORWEGIANUNIVERSITYOF SCIENCEANDTECHNOLOGY,