You are on page 1of 2

BPL

This document is the private property of BPL Telecom Limited. It must not be reproduced, disclosed to any third parties or used for manufacturing purposes without permission in writing from BPL Telecom Limited, Palakkad - 678 007 (Kerala)

Client Project Specification No LOA No. Contractor : Power Grid Corporation of India Limited : Grid Strengthening for Tamilnadu-I & Kerala-I & II : C-52714-S919A-7 : C-52714-S919A-7/LOA-I /2118 Dt:04.08.2006 : Jyoti Structures, Limited Mumbai

30

18

10

18

50

10

30

2 1 ISSUE C.No
3a LT LT 3b LT LT

OVER UPTO TOL.

COCHIN NEW

LT= LINE TRAP

TOLERANCE UNLESS SPECIFIED MATERIAL

FINISH

CHANGE

CF

CF CF CF

CF

CF

CF

CF

CD

BT

1a HF CABLE 2

CD

BT

1a

CD

BT

1b

CD

BT

1b

NORTH TRICHUR

ANGLE

CKT I

+ 0.1

DEV.VER.

+ 0.25

+ 0.3

+ 0.2

+ 0.15

80

50

DATE

OVER UPTO

500

250

120

LT LT
CVT

LT LT

80

120

500

250

+ 0.7

+ 0.6

+ 0.5

+ 0.4

TOL.

+ 0.35

*
CVT CVT

CVT *

CKT II

HF CABLE 2 9505-HP 4a 4a 4b 9505-HP 9505-HP 9505-HP 9505-HP 4b 6710-C42 6b 5b 9505-HP 9505-HP 4b 6710-C42 6710-C42 6b 6b 9505-HP 4b 6710-C42 6b 5b 9505-HP

9505-HP

9505-HP

9505-HP

4a 4a 9a 9b
6710-C42 6a 6710-C42 6a 5a 6710-C42 6710-C42

APPD

DRAWN

CHECKED
5a 6a 6a

APPD.

4 3 ISSUE

Ckt-II Ckt-I
EPA X 24/8

Ckt-I
8a Direction.

* EPAX

Ckt-II
3
8b

TITLE GENERAL ARRANGEMENT


Sl.no Description Type LMU 75 ohms 9505 HP-S/C 9505 HP-S/C 6710 C42 6710 C42 24/8/4 95 FOREX 5499 9505 HP-S/C 9505 HP-S/C PLC set for sp+Data PLC set for sp+Data Coupling Filter HF coaxial cable PLC set for sp+Protn PLC set for sp+Protn Protection Coupler Protection Coupler EPAX MDX-50 4 Wire PBTs Linetraps 2 wire PBTs 1 a&b 2 4b 4a 6b 6a 7 9 a&b 3 a&b 8 a&b 5b 5a Location Cochin New Cochin New North Trichur Cochin New Norh Trichur Cochin New Cochin New Cochin New Cochin New Cochin New North Trichur Cochin New Cochin new North Trichur North Trichur North Trichur Cochin New North Trichur Cochin New North Trichur * North Trichur North Trichur

C.No DATE

OF EQUIPMENTS FOR COCHIN NEW- NORTH TRICHUR 400 KV D/C LINE

PALAKKAD

NOTES:

CHANGE

678 007

DRAWING No.

QTY/ SCALE SCHEDULE ITEM SET

DIMENSIONS IN MM WHEN IN DOUBT, ASK.

DO NOT SCALE THE DRG.

BPL TELECOM LIMITED

SHEET 1 OF 1 SHTS.

1.For modular layout of equipments, refer the following a. Carrier Terminal Drg. No. 476 009 821 b. Protection Coupler Drg. No. 480 009 801 2. All terminals with Telephone Jack

051 350 476

KERALA

APPD

BPL

This document is the private property of BPL Telecom Limited. It must not be reproduced, disclosed to any third parties or used for manufacturing purposes without permission in writing from BPL Telecom Limited, Palakkad - 678 007 (Kerala)

Client Project Specification No LOA No. Contractor : Power Grid Corporation of India Limited : Grid Strengthening for Tamilnadu-I & Kerala-I & II : C-52714-S919A-7 : C-52714-S919A-7/LOA-I /2118 Dt:04.08.2006 : Jyoti Structures, Limited Mumbai

30

18

10

18

50

10

30

2 1 ISSUE C.No
3a LT * LT 3b LT LT *

OVER UPTO TOL.

COCHIN EXTN

TOLERANCE UNLESS SPECIFIED MATERIAL

ANGLE

CKT I

+ 0.1

DEV.VER.

+ 0.25

TIRUNELVELI

+ 0.3

+ 0.2

+ 0.15

80

50

DATE

OVER UPTO

500

250

120

LT * LT *
CVT

LT LT

80

120

500

250

+ 0.7

+ 0.6

+ 0.5

+ 0.4

TOL.

+ 0.35

*
CVT CVT

CVT *

CKT II

FINISH
LT *
CF CF CF CF CF CF CF CD BT

CHANGE
1a HF CABLE 2 9505-HP 9505-HP 4a 4a 4a 4b 4a 9505-HP 9505-HP 9505-HP 9505-HP 9505-HP 4b 6710-C42 6b 5b 9505-HP
CD BT

CF

1a

CD

BT

1b

CD

BT

1b

GENERAL ARRANGEMENT OF EQUIPMENTS FOR COCHIN (EXTN) TIRUNELVELI 400 KV D/C LINE 9a
6710-C42 6710-C42 6a 6710-C42 6a 6a 5a 6710-C42 6a

TITLE
9b
6710-C42 6b

HF CABLE 2 9505-HP 4b 6710-C42 6b 9505-HP 4b 6710-C42 6b

APPD

DRAWN

CHECKED

APPD.

4 3 ISSUE

Ckt-II Ckt-I
EPA X *

Ckt-I
8a Direction. Tirunelveli Tirunalveli

EPAX *

Ckt-II
7

8b

Sl.no Type LMU 75 ohms 9505 HP-S/C 6710 C42 6710 C42 * 95 FOREX 1 a&b Coupling Filter 2 HF coaxial cable PLC set for sp+Protn PLC set for sp+Protn Protection Coupler Protection Coupler EPAX 4 Wire PBTs 4b 4a 6b 6a 7 9 a&b 3 a&b Linetraps * 8 a&b 5b 5a 2 wire PBTs PLC set for sp+Data PLC set for sp+Data

Description

Location Cocin New Cochin Extn Tirunalveli Tirunalveli Cochin xtn * Cochin Extn Cochin Extn

C.No DATE

Cochin Extn Tirunalveli Cochin Extn Tirunalveli * Tirunalveli Tirunelveli

PALAKKAD

9505 HP-S/C Cochin Eextn

NOTES:

CHANGE

678 007

DRAWING No.

QTY/ SCALE SCHEDULE ITEM SET

DIMENSIONS IN MM WHEN IN DOUBT, ASK.

DO NOT SCALE THE DRG.

1. For modular layout of equipments, refer the following a. Carrier Terminal Drg. No. 476 009 821 b. Protection Coupler Drg. No. 480 009 801 2. All terminals with Telephone Jack

BPL TELECOM LIMITED

051 352 476

SHEET 1 OF 1 SHTS.

KERALA

APPD

9505 HP-S/C 9505 HP-S/C

Tirunalveli Cochin Extn

Cochin extn Tirunelveli

You might also like