Professional Documents
Culture Documents
DELPHYS MP
High availability
A fault tolerant architecture with redundancy of basic functions, such as the ventilation system. A variety of architectures for parallel operations, to deal with redundancy, management and changes in power output.
User-friendly operation
A control panel with graphic display for more ergonomic operation. An array of com-slot plug-in communication interfaces, for upgrading your operating requirements.
Simplified maintenance
An advanced diagnostic system. A remote access device connected to the remote maintenance centre. Easy access to subassemblies and components, facilitating tests and reducing maintenance time (MTTR).
48
Three-phase UPS
DELPHYS MP
from 60 to 200 kVA
kW
LAGGING
cos 0,9 cos 0,8 cos 0,7 cos 0,6
100% kW cos 1
1 10
k 0%
VA va
kVAr
-1
-0,8
-0,6
-0,4
-0,2
0,2
0,4
0,6
0,8
49
Three-phase UPS
DELPHYS MP
from 60 to 200 kVA
Parallel systems
In order to meet the most demanding availability requirements, and the need for the installation to be flexible and upgradable, up to 6 DELPHYS MP can run in parallel.
DEFYS 065 A
DELPHYS MP a twin channel architecture with Static Transfer Systems: LTM and IT SWITCH [Info. p. 66 and 70].
ACS DELPHYS MPelite
DEFYS 093 A
DEFYS 059 B
Load 1
LTM 2
Load 2
DEFYS 094 A
DEFYS128 A GB
IT-SWITCH
Load 3
Standard equipment
Slots for 7 communication boards. Protection backfeed: detection circuit. Standard interface: - 3 inputs (emergency stop, generating set, battery protection), - 4 outputs (general alarm, back-up, bypass, preventive maintenance needs).
DEFYS 026A
Graphic display
Design adapted to the user: control panel with LEDs and LCD display.
Accessories
BHC battery unit monitoring. EBS (Expert Battery System) [Info. p. 99]. Colour touch screen. ACS function for synchronisation with an external source [Info. p. 68 and 72]. Reinforced IP protection degree. Ventilation filters. Ventilation control.
DEFYS 111 A GB
Remote control panel. ADC (Advanced Dry Contacts) data input and output by dry contacts [Info. p. 98]. RS232, RS422, RS 485 serial port JBUS / MODBUS or PROFIBUS protocol [Info. p. 98]. NET VISION interface for the LAN Ethernet network [ Info. p. 87]. TOP VISION software for supervision with WindowsTM [Info. p. 89].
Remote maintenance
e.SERVICE for continuous monitoring the SOCOMEC SICON UPS maintenance service. [Info. p. 100]
Status bar
50
Three-phase UPS
DELPHYS MP
from 60 to 200 kVA
DELPHYS MP DELPHYS MP elite Weight Weight kg kg 640 680 660 700 790 820 810 840 920 970 950 1000
Battery for back-up time B mm 800 800 800 800 1600 1600 Weight kg 800 1000 1300 1700 1900 2500 B mm 800 800 800 1600 1600 2400 Weight kg 1000 1300 1700 1900 2500 3000
1930
DEFYS 126 A F
10 minutes
15 minutes
B A*
* DELPHYS MP DELPHYS MP elite A = 800 mm A = 1 000 mm
80
Bypass cabinet
The coupling and centralised bypass functions.
Power(1) kVA 60 80 120 200 250 300 400 500 800 1200 W mm 800 800 800 800 800 800 800 800 1000 1300 Weight kg 280 280 280 300 300 320 320 330 420 600
Q4 Rectifier Inverter Q3
DEFYS 124 B GB
Q20
Battery
1930
Technical data
RECTIFIER INPUT Technology DELPHYS MP DELPHYS MP elite Voltage Acceptable tolerance Frequency Power factor: DELPHYS MP elite Distortion rate: DELPHYS MP elite OUTPUT Voltage (configurable) Voltage tolerance Static load Dynamic load conditions from 0 to 100% Voltage distortion rate Acceptable crest factor without de-rating PF acceptable without de-rating Frequency (configurable) Autonomous frequency tolerance Overload Efficiency Global (2) In ECO-MODE configuration ENVIRONMENT Noise level (ISO 3746)(2) Compliance to standards Safety EMC Technical data Classification as per IEC62040-3
DEFYS 125 A GB
80
Bypass transformer
For galvanic isolation.
Power(1) kVA 60 80 120 200 300 400 W mm 600 600 600 800 1000 1200 Weight kg 400 450 550 850 1250 1500
SCR PFC - IGBT three-phase 380 V - 400 V - 415 V (1) 340 to 460 V 50 - 60 Hz (45 to 65 Hz) 0.99 THDI: 2.5% three-phase + N 380 V - 400 V - 415 V (1) < 1% 2% in 5 ms THDU < 2% 3:1 lagging to 0.9 lead. 50 - 60 Hz 0.2% 1 min: 150% 10 min: 125% up to 93.5% 98% 68 dBA IEC62040-1-2/IEC60950 IEC62040-2 IEC62040-3 UPS VFI (3) - SS - 111
DEFYS 087 A GB
80
1930
(1) Three-phase 220-230-240 V on demand. - (2) As per power range. - (3) Voltage Frequency Independent.
51