You are on page 1of 5

P.

101

Floor and ceiling fan coil units


Construction features
Heat exchanger: finned coil with left-hand connections reversible to right Centrifugal fan: 3-speed. Structure: covering cabinet in pre-painted metal sheet complete with renewable filter, grilles in ABS polymer and condensation drain pan with natural drainage.

STANDARD CONTROLS
For wall installation Panel with speed and summer/winter switch. Panel with room thermostat. Panel with room thermostat, summer/winter switch, ON/OFF valve signal and electric heater. Minimum temperature thermostat (for installation on the machine). Electronic panel with automatic summer/winter changeover for 2-pipe-systems. Electronic panel with automatic summer/winter changeover and automatic speed regulation for 2-pipe-systems with electric heater or 4-pipe-systems. For installation on machine (MVP and MVT versions) Panel with speed switch. Panel with room thermostat, summer/winter switch and speed switch. Minimum temperature thermostat. Panel with room thermostat, summer/winter switch, ON/OFF valve signal and electric heater. Electronic panel with automatic summer/winter changeover for 2-pipe systems. Electronic panel with automatic summer/winter changeover and automatic speed regulation for 2-pipe-systems with electric heater or 4-pipe-systems.
Key:
Factory fitted Supplied loose

Versions
MVP - Vertical unit with cabinet equipped with lower air inlet and upper outlet for wall mounting or with feet on ground. MVT - Vertical unit with cabinet equipped with front air inlet and upper outlet for floor installation. MOP - Horizontal unit with cabinet equipped with rear air inlet and front outlet for ceiling installation. MOT - Horizontal unit with cabinet equipped with lower air inlet and front outlet for ceiling installation.

ACCESSORIES
Additional water heating coil. Electric heater. Auxiliary condensation drain pan. Manual damper. Motorized damper. Valve and balancing valve. ON/OFF 3-way valve for 2-pipe-systems. ON/OFF 3-way valves for 4-pipe-systems. Rear panel. Rear closure panel. Rear closure panel with grille and filter. Support feet with pipe cover.

FAN COIL UNITS

Unit-System 1,17,2 kW 2,417,4kW

ADVANCED CONTROLS
Electronic control panel for wall mounting. For installation on machine. Master electronic card with electronic control panel ( only for MVP - MVT versions). Master/slave electronic card. Temperature probe for heat row. Module for management of ON/OFF valves and electric heater. Serial interface for connection to BMS (proprietary protocol, Modbus RTU). Serial converters (RS485/RS232, RS485/USB) in the case of centralised unit management. Serial interface (CAN-bus - Controller Area Network) for the iDRHOSS system.

Key:

Factory fitted

Supplied loose

MODEL YardyEV MOP-MOT-MVP-MVT & PUMP Cooling capacity MAX kW (total heat) MED kW MIN kW Heating capacity (70C) MAX kW MED kW MIN kW Heating capacity (50C) MAX kW Heating capacity MAX kW additional coil MED kW MIN kW Air flow speed MAX m3/h MED m3/h MIN m3/h Sound power MAX dB(A) MED dB(A) MIN dB(A) Sound pressure speed MAX dB(A) MED dB(A) MIN dB(A) Maximum absorbed power W Main supply DIMENSIONS AND WEIGHTS L - Width H - Height Height of feet P - Depth Weight V-ph-Hz mm mm mm mm kg

15 1,02 0,87 0,62 2,40 2,02 1,35 1,41 1,40 1,16 0,98 209 163 100 43 35 26 35 27 18 32

20 1,71 1,32 1,09 3,74 2,81 2,34 2,20 2,16 1,72 1,48 288 207 155 44 35 28 36 27 20 30

22 1,92 1,49 1,14 4,30 3,39 2,64 2,52 2,22 1,97 1,64 339 238 177 48 40 32 40 32 24 38

25 2,42 1,95 1,56 5,66 4,39 3,53 3,31 3,01 2,56 2,07 484 339 252 48 38 30 40 30 22 45

35 2,96 2,49 2,00 6,51 5,45 4,31 3,82 3,24 2,78 2,30 547 434 329 50 43 36 42 35 28 54

40 3,61 2,74 2,38 8,32 6,15 5,26 4,88 3,92 3,41 3,02 676 472 390 52 43 38 44 35 30 72

45 4,12 3,19 2,89 8,88 6,58 6,08 5,26 3,93 3,41 3,04 681 474 431 52 43 41 44 35 33 70

55 5,23 4,27 3,78 11,70 9,32 7,86 6,83 6,11 5,16 4,55 1.077 802 662 61 52 47 51 44 39 115

65 6,34 5,28 4,28 14,23 11,72 10,01 8,36 6,31 5,80 5,58 1.235 948 757 62 56 50 54 48 42 161

75 7,19 5,97 5,51 17,37 14,92 13,42 10,08 6,81 6,20 5,64 1.480 1.171 994 66 61 57 58 53 49 184

230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 15 700 570 100 220 25 20 800 570 100 220 31 22 800 570 100 220 31 25 1.000 570 100 220 38 35 1.000 570 100 220 39 40 1.200 570 100 220 43 45 1.200 570 100 220 44 55 1.500 570 100 220 55 65 1.500 570 100 220 55 75 1.500 570 100 220 57

MOP

MOT

MVP

MVT

P H H L

In the following conditions: Air: 27C D.B.; 19C W.B. - Water: 7/12C. Air: 20C - Water: 70/60C. Air: 20C - Water: 50C, flow rate as in cooling. At 1 m from air outlet with directionality factor of 2.

MVP+feet

P.103

Ductable and recessed fan coil units.


Construction features
Heat exchanger: finned coil with left-hand connections reversible to right. Centrifugal fan: 3-speed for versions IVP, IVF and IOP; 5speed for COP versions. Structure: in galvanized metal sheet complete with renewable filter and condensation drain pan with natural drainage.

STANDARD CONTROLS
For wall installation Panel with speed and summer/winter switch. Panel with room thermostat. Panel with room thermostat, summer/winter switch, ON/OFF valve signal and electric heater. Minimum temperature thermostat (for installation on the machine). Electronic panel with automatic summer/winter changeover for 2-pipe-systems. Electronic panel with automatic summer/winter changeover and automatic speed regulation for 2-pipe-systems with electric heater or 4-pipe-systems.

Versions
IVP - Recessed vertical unit equipped with lower air inlet and upper outlet for wall installation. IVF - Recessed vertical unit equipped with lower air inlet and front outlet for wall installation. IOP - Recessed horizontal unit equipped with rear air inlet and front outlet for ceiling installation. COP - Ductable recessed horizontal unit equipped with rear air inlet and front outlet for ceiling installation.

ADVANCED CONTROLS

ACCESSORIES
Additional water heating coil. Electric heater. Auxiliary condensation drain pan. Motorized damper. Valve and balancing valve. ON/OFF 3-way valve for 2-pipe-systems. ON/OFF 3-way valves for 4-pipe-systems. Straight outlet connection. 90 outlet connection. 90 inlet connection. Telescopic outlet/inlet connection. Inlet grille with filter. Outlet grille. Cover panel with grilles (only IVF and IOP). Inlet plenum with circular nozzles. Outlet plenum with circular nozzles.

Key:

Factory fitted

Supplied loose

FAN COIL UNITS

Electronic control panel for wall mounting. For installation on machine. Master/slave electronic card. Temperature probe for hot row. Module for management of ON/OFF valves and electric heater. Serial interface for connection to BMS (proprietary protocol, Modbus RTU). Serial converters (RS485/RS232, RS485/USB) in the case of centralised unit management. Serial interface (CAN-bus - Controller Area Network) for the iDRHOSS system.

Wall fitted panel

Electronic control panel for wall mounting.

MODEL YardyEV IOP-IVP-IVF Cooling capacity MAX (total heat) MED MIN Heating capacity (70C) MAX MED MIN Heating capacity (50C) MAX Heating capacity MAX additional coil MED MIN Air flow speed MAX MED MIN Sound power level MAX MED MIN Sound pressure speed MAX MED MIN Maximum absorbed power Main supply DIMENSIONS AND WEIGHTS L - Width H - Height P - Depth Weight

kW kW kW kW kW kW kW kW kW kW m3/h m3/h m3/h dB(A) dB(A) dB(A) dB(A) dB(A) dB(A) W V-ph-Hz mm mm mm kg

15 1,02 0,87 0,62 2,40 2,02 1,35 1,41 1,40 1,16 0,98 209 163 100 43 35 26 35 27 18 32

20 1,71 1,32 1,09 3,74 2,81 2,34 2,20 2,16 1,72 1,48 288 207 155 44 35 28 36 27 20 30

22 1,92 1,49 1,14 4,30 3,39 2,64 2,52 2,22 1,97 1,64 339 238 177 48 40 32 40 32 24 38

25 2,42 1,95 1,56 5,66 4,39 3,53 3,31 3,01 2,56 2,07 484 339 252 48 38 30 40 30 22 45

35 2,96 2,49 2,00 6,51 5,45 4,31 3,82 3,24 2,78 2,30 547 434 329 50 43 36 42 35 28 54

40 3,61 2,74 2,38 8,32 6,15 5,26 4,88 3,92 3,41 3,02 676 472 390 52 43 38 44 35 30 72

45 4,12 3,19 2,89 8,88 6,58 6,08 5,26 3,93 3,41 3,04 681 474 431 52 43 41 44 35 33 70

55 5,23 4,27 3,78 11,70 9,32 7,86 6,83 6,11 5,16 4,55 1.077 802 662 61 52 47 51 44 39 115

65 6,34 5,28 4,28 14,23 11,72 10,01 8,36 6,31 5,80 5,58 1.235 948 757 62 56 50 54 48 42 161

75 7,19 5,97 5,51 17,37 14,92 13,42 10,08 6,81 6,20 5,64 1.480 1.171 994 66 61 57 58 53 49 184

230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 15 450 545 212 22 20 550 545 212 28 22 550 545 212 28 25 750 545 212 35 35 750 545 212 36 40 950 545 212 39 45 950 545 212 40 55 1.250 545 212 48 65 1.250 545 212 50 75 1.250 545 212 52

IOP

IVP

IVF

P L

H H

P In the following conditions: Air: 27C D.B.; 19C W.B. - Water: 7/12C. Air: 20C - Water: 70/60C. Air: 20C - Water: 50C, flow rate as in cooling. At 1 m from air outlet with directionality factor of 2.

P.105

Unit-System 1,17,2 kW 2,417,4 kW

Electronic control panel for wall mounting. Wall fitted panel

YardyEV COP with inlet and outlet plenum with circular nozzles

MODEL YardyEV COP Cooling capacity (total heat)

Heating capacity (70C)

Heating capacity (50C)

Heating capacity additional coil

Air flow speed

Sound power level

Sound pressure speed

V IV III II I V IV III II I V IV III II I V IV III II I V IV III II I V IV III II I V IV III II I

Maximum absorbed power Main supply DIMENSIONS AND WEIGHTS L - Width H - Height P - Depth Weight

kW kW kW kW kW kW kW kW kW kW kW kW kW kW kW kW kW kW kW kW m3/h m3/h m3/h m3/h m3/h dB(A) dB(A) dB(A) dB(A) dB(A) dB(A) dB(A) dB(A) dB(A) dB(A) W V-ph-Hz mm mm mm kg

33 3,46 3,28 2,98 2,50 2,32 7,64 7,25 6,58 5,51 5,11 4,48 4,24 3,85 3,23 3,00 3,83 3,64 3,31 2,78 2,58 695 645 560 440 400 60 58 55 49 47 52 50 47 41 39 60 230-1-50 33 750 545 212 35

44 5,38 4,53 4,16 3,83 3,41 11,2 9,44 8,66 7,96 7,10 6,63 5,60 5,13 4,72 4,21 5,57 4,72 4,31 3,97 3,54 970 765 685 615 535 66 62 60 58 55 58 54 52 50 47 80 230-1-50 44 950 545 212 40

66 6,17 5,96 5,61 5,33 4,99 13,6 13,1 12,3 11,7 11,0 7,95 7,66 7,23 6,86 6,44 6,07 5,85 5,50 5,24 4,91 1.195 1.130 1.040 970 890 65 63 61 60 59 57 55 53 52 51 120 230-1-50 66 1.250 545 212 52

In the following conditions: Air: 27C D.B.; 19C W.B. - Water: 7/12C. Available static pressure 0 Pa. Air: 20C - Water: 70/60C. Available static pressure 0 Pa. Air: 20C - Water: 50C, flow rate as in cooling; max. speed Available static pressure 0 Pa. At 1 m from air outlet with directionality factor of 2, non-ducted unit.

COP

P L

FAN COIL UNITS

You might also like