TERMINAL BOARD WIRING Suitable for automatic sliding gates & for Rolling shutters

AUTOMATIC DETECTION OF MOTOR TRAVEL LIMITS (TERMINAL SWITCHES)


The board can recognize automatically the mechanical travel switches of the motor. When any travel switch switches off then the operating time is reset and the board is ready for the next command.

AUTOMATIC POWER STOP: The control board is constantly measuring the motor operation current and if a sudden change is detected the motor stops.
Transmitters Code Memorizing AUTO-LEARN The board can be programmed to accept up to 15 remote controls with different code or channel. In order to program the board to accept a remote control we press once the button "AUTO LEARN" on the board. Then the LED L5 is turned ON for about 10''. As long as it is lit, we can s tore any remote control in the board memory by pressing the button of the remote control. If the board accepts the remote control then the LED turns off and the motor starts. If we don't press any remote control, after 10'' the LED turns off and the board comes out of the AUTO LEARN function. When we want to store more than 4 codes, then automatically the oldest code will be cancelled and replaced by the new one. Erase All Programmed Codes To erase all programmed memory remote controls from the board then we press the button continuously (about 10'') until the LED is flashing, Then we release the button. All the programmed codes have been erased.. .
AUTO CLOSE FUNCTION
LED FUNCTIONS L5
LEDL5 apart from the use of memorizing the transmitters codes, also functions the ODS. When the LED is not lit while the motor is in operation, then the Obstactle Detection System is not in use. When the LED is flashing while the motor is in operation then the ODS is in use.

Adjust the automating closing time (in seconds), after which the gate closes 60 automatically.
120 The automating
closing time is off.

Obstacle detection System


LOW-SENSITIVE

ODS FUNCTION

LAMP FUNCTION
ON

ON

HI-SENSITIVE

OUT OF USE

ODS

Lighting operation The light is on continuously as long as the motor is operating & turns off 1 minute after the motor stops. Flashing operation The light is flashing as long as the motor is operating & turns off when the motor stops.

START BUTTON FUNCTIONS


ON

1
ON

OPEN OPEN

STOP STOP

CLOSE CLOSE

STOP OPEN ....

OPEN ....

Power indicator L6

L6

PHOTO-CELL FUNCTIONS
In order to connect photo-cells the board has an auxiliary output ( 24Volt / 200mA
ON

3
ON

The motor stops in case of obstactle detection. The motor stops & opens in case of obstactle detection.

ODS Obstacle Detection System FUNCTIONS (POWER STOP)

L5

ON

4
ON

The motor stops in case of obstactle detection. The motor stops & opens in case of obstactle detection.

L1 L2 L3 L4

Indication of LED Function


L1 Light ON -->terminal switch contact is closed
Light OFF -->terminal switch contact is opened Terminal CLOSE LIMIT switch Terminal OPEN LIMIT switch

open

common

L2 Light ON -->terminal switch contact is closed


close

Light OFF -->terminal switch contact is opened START button LED

230VAC

LAMP 220V
MOTOR 230VAC

L3 Light ON --> button is pressed (closed)


OPEN LIMIT switch Photo Cell contact

Light OFF --> button is not pressed (open)

! The first operation command of the motor after the power interruption is "OPEN"

L4 Light ON --> photo-cell contact is closed


CLOSE LIMIT switch START BUTTON switch (N.O.)

Photo Cell LED

Light OFF --> photo-cell contact is opened

Exclusively skilled technical personnel must install the control unit in compiliance with the regulations concerning the field of automatic opening devices, blinds, rolling shutters. Unqualified personnel or those who do not know the standards applicable to the Automatic gates and doors category must under no circumstances carry out installations and systems. ANTENNA As Antenna serves an insulated wire, which has been specially selected for this purpose. Please, position it as far away from metallic objects as possible. Do not shorten, lengthen, or otherwise modify the wire. Connect a 17 cm piece of rigid wire to the antenna pole binding post. For best results use a tuned antenna connected to the receiver using RG 58 (impedance 50 Ohm) coaxial cable with a maximum length of 15 meters. Exclusively skilled technical personnel according to the rules concerning the field of automatic opening devices, blinds, rolling shutters, must install the control unit. Unqualified personnel or those who do not know the standards applicable to the Automatic gates and doors category must under no circumstances carry out installations